Gerald B. Matson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Gerald B. Matson has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
Hui Liu
Department of Veterans Affairs Medical Center, Center for Imaging of Neurodegenerative Diseases (114M), University of California, San Francisco, California, USA
1 shared publication- Hui Liu
Center for Imaging of Neurodegenerative Diseases, Veterans Affairs Medical Center, San Francisco, CA 94121, USA
1 shared publication Karl Young
Center for Imaging of Neurodegenerative Diseases (114M), Department of Veterans Affairs Medical Center, University of California, 4150 Clement Street, San Francisco, CA 94121, USA
1 shared publicationLana G. Kaiser
Center for Imaging of Neurodegenerative Diseases (114M), Department of Veterans Affairs Medical Center, University of California, 4150 Clement Street, San Francisco, CA 94121, USA
1 shared publication
Latest Publications
- 1 December 2017
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 44, 146-156
Design strategies for improved velocity-selective pulse sequences
- 1 December 2017
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 44, 146-156
Design strategies for improved velocity-selective pulse sequences
- Open Access
Accurate Measurement of Magnetic Resonance Imaging Gradient Characteristics
Recently, gradient performance and fidelity has become of increasing interest, as the fidelity of the magnetic resonance (MR) image is somewhat dependent on the fidelity of the gradient system. In particular, for high fidelity non-Cartesian imaging, due to non-fidelity of the gradient system, it becomes necessary to know the actual k-space trajectory as opposed to the requested trajectory. In this work we show that, by considering the gradient system as a linear time-invariant system, the gradient impulse response function (GIRF) can be reliably measured to a relatively high degree of accuracy with a simple setup, using a small phantom and a series of simple experiments. It is shown experimentally that the resulting GIRF is able to predict actual gradient performance with a high degree of accuracy. The method captures not only the frequency response but also gradient timing errors and artifacts due to mechanical vibrations of the gradient system. Some discussion is provided comparing the method presented here with other analogous methods, along with limitations of these methods.
Open AccessAccurate Measurement of Magnetic Resonance Imaging Gradient Characteristics
Recently, gradient performance and fidelity has become of increasing interest, as the fidelity of the magnetic resonance (MR) image is somewhat dependent on the fidelity of the gradient system. In particular, for high fidelity non-Cartesian imaging, due to non-fidelity of the gradient system, it becomes necessary to know the actual k-space trajectory as opposed to the requested trajectory. In this work we show that, by considering the gradient system as a linear time-invariant system, the gradient impulse response function (GIRF) can be reliably measured to a relatively high degree of accuracy with a simple setup, using a small phantom and a series of simple experiments. It is shown experimentally that the resulting GIRF is able to predict actual gradient performance with a high degree of accuracy. The method captures not only the frequency response but also gradient timing errors and artifacts due to mechanical vibrations of the gradient system. Some discussion is provided comparing the method presented here with other analogous methods, along with limitations of these methods.
- Open Access
- 26 April 2011
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 66 (5) , 1254-1266
Radiofrequency pulse designs for three‐dimensional MRI providing uniform tipping in inhomogeneous B1 fields
Although high‐field MRI offers increased signal‐to‐noise, the nonuniform tipping produced by conventional radiofrequency (RF) pulses leads to spatially dependent contrast and suboptimal signal‐to‐noise, thus complicating the interpretation of the MR images. For structural imaging, three‐dimensional sequences that do not make use of frequency‐selective RF pulses have become popular. Therefore, the aim of this research was to develop non‐slice‐selective (NSS) RF pulses with immunity to both amplitude of (excitation) RF field (B1) inhomogeneity and resonance offset. To accomplish this, an optimization routine based on optimal control theory was used to design new NSS pulses with desired ranges of immunity to B1 inhomogeneity and resonance offset. The design allows the phase of transverse magnetization produced by the pulses to vary. Although the emphasis is on shallow tip designs, new designs for 30°, 60°, 90°, and 180° NSS RF pulses are also provided. These larger tip angle pulses are compared with recently published NSS pulses. Evidence is presented that the pulses presented in this article have equivalent performance but are shorter than the recently published pulses. Although the NSS pulses generate higher specific absorption rates and larger magnetization transfer effects than the rectangular pulses they replace, they nevertheless show promise for three‐dimensional MRI experiments at high field. Magn Reson Med, 2011.
- 26 April 2011
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 66 (5) , 1254-1266
Open AccessRadiofrequency pulse designs for three‐dimensional MRI providing uniform tipping in inhomogeneous B1 fields
Although high‐field MRI offers increased signal‐to‐noise, the nonuniform tipping produced by conventional radiofrequency (RF) pulses leads to spatially dependent contrast and suboptimal signal‐to‐noise, thus complicating the interpretation of the MR images. For structural imaging, three‐dimensional sequences that do not make use of frequency‐selective RF pulses have become popular. Therefore, the aim of this research was to develop non‐slice‐selective (NSS) RF pulses with immunity to both amplitude of (excitation) RF field (B1) inhomogeneity and resonance offset. To accomplish this, an optimization routine based on optimal control theory was used to design new NSS pulses with desired ranges of immunity to B1 inhomogeneity and resonance offset. The design allows the phase of transverse magnetization produced by the pulses to vary. Although the emphasis is on shallow tip designs, new designs for 30°, 60°, 90°, and 180° NSS RF pulses are also provided. These larger tip angle pulses are compared with recently published NSS pulses. Evidence is presented that the pulses presented in this article have equivalent performance but are shorter than the recently published pulses. Although the NSS pulses generate higher specific absorption rates and larger magnetization transfer effects than the rectangular pulses they replace, they nevertheless show promise for three‐dimensional MRI experiments at high field. Magn Reson Med, 2011.
- 31 July 2009
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 199 (1) , 30-40
RF pulses for in vivo spectroscopy at high field designed under conditions of limited power using optimal control
- 31 July 2009
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 199 (1) , 30-40
RF pulses for in vivo spectroscopy at high field designed under conditions of limited power using optimal control