Dick G. Markhorst
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Dick G. Markhorst has a total of 44 co-authors. Here are the top co-authors by number of shared publications:
- Marc van Heerde
Department of Pediatric Intensive Care, VU university medical center, Amsterdam, The Netherlands
5 shared publications - Frans B. Plötz
Department of Pediatric Intensive Care, VU university medical center, Amsterdam, The Netherlands
4 shared publications Adrianus J. van Vught
Pediatric ICU, Department of Pediatrics, Wilhelmina Children’s Hospital, Utrecht, The Netherlands
2 shared publicationsH. R. Van Genderingen
2 shared publicationsHuibert R. van Genderingen
Department of Physics and Medical Technology, Vrije Universiteit Medical Centre, Amsterdam, The Netherlands
2 shared publications- Johannes G. M. Burgerhof
Department of Epidemiology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
2 shared publications
Latest Publications
- Open Access
- 1 January 2019
- Published by Elsevier in Annals of Intensive Care
- Vol. 9 (1) , 9
Feasibility of an alternative, physiologic, individualized open-lung approach to high-frequency oscillatory ventilation in children
- 1 January 2019
- Published by Elsevier in Annals of Intensive Care
- Vol. 9 (1) , 9
Open AccessFeasibility of an alternative, physiologic, individualized open-lung approach to high-frequency oscillatory ventilation in children
- Open Access
- 26 February 2018
- Published by Springer Nature in European Journal of Pediatrics
- Vol. 177 (5) , 633-639
Fitness to fly in the paediatric population, how to assess and advice
The number of children on commercial aircrafts is rising steeply and poses a need for their treating physicians to be aware of the physiologic effects and risks of air travel. The most important risk factors while flying are a decrease in partial oxygen pressure, expansion of trapped air volume, low cabin humidity, immobility, recirculation of air and limited options for medical emergencies. Because on-board medical emergencies mostly concern exacerbations of chronic disease, the medical history, stability of current disease and previous flight experience should be assessed before flight. If necessary, hypoxia altitude simulation testing can be performed to simulate the effects of in-flight hypoxia. Although the literature on paediatric safety of air travel is sparse, recommendations for many different situations can be given. Conclusion: We present an overview of the most up to date recommendations to ensure the safety of children during flight. What is Known: • Around 65% of on-board medical emergencies are complications of underlying disease. • In children, the three most common emergencies during flight concern respiratory, neurological and infectious disease. What is New: • Although studies are scarce, some advices to ensure safe air travel can be given for most underlying medical conditions in children, based on physiology, studies in adults and expert opinions. • In former preterm infants without chronic lung disease, hypoxia altitude simulation testing to rule out in-flight desaturation is not recommended.
- 26 February 2018
- Published by Springer Nature in European Journal of Pediatrics
- Vol. 177 (5) , 633-639
Open AccessFitness to fly in the paediatric population, how to assess and advice
The number of children on commercial aircrafts is rising steeply and poses a need for their treating physicians to be aware of the physiologic effects and risks of air travel. The most important risk factors while flying are a decrease in partial oxygen pressure, expansion of trapped air volume, low cabin humidity, immobility, recirculation of air and limited options for medical emergencies. Because on-board medical emergencies mostly concern exacerbations of chronic disease, the medical history, stability of current disease and previous flight experience should be assessed before flight. If necessary, hypoxia altitude simulation testing can be performed to simulate the effects of in-flight hypoxia. Although the literature on paediatric safety of air travel is sparse, recommendations for many different situations can be given. Conclusion: We present an overview of the most up to date recommendations to ensure the safety of children during flight. What is Known: • Around 65% of on-board medical emergencies are complications of underlying disease. • In children, the three most common emergencies during flight concern respiratory, neurological and infectious disease. What is New: • Although studies are scarce, some advices to ensure safe air travel can be given for most underlying medical conditions in children, based on physiology, studies in adults and expert opinions. • In former preterm infants without chronic lung disease, hypoxia altitude simulation testing to rule out in-flight desaturation is not recommended.
- Open Access
- 1 January 2016
- Published by Elsevier in Annals of Intensive Care
- Vol. 6 (1) , 103-11
Short-term effects of neuromuscular blockade on global and regional lung mechanics, oxygenation and ventilation in pediatric acute hypoxemic respiratory failure
- 1 January 2016
- Published by Elsevier in Annals of Intensive Care
- Vol. 6 (1) , 103-11
Open AccessShort-term effects of neuromuscular blockade on global and regional lung mechanics, oxygenation and ventilation in pediatric acute hypoxemic respiratory failure
- 23 August 2013
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 28 (1) , 63-66
Bench test assessment of mainstream capnography during high frequency oscillatory ventilation
To assess the feasibility, stability and predictability of pCO2 measurement (PetCO2) using a main stream capnograph in a high frequency oscillatory ventilation circuit. A commercially available capnograph was mounted into a high frequency oscillatory ventilator patient circuit, adjustable CO2 flow was introduced into an artificial lung and the output of the CO2 sensor assessed under varying ventilator settings. Influence of oxygen content, pressures, heat and moisture were recorded. A linear relationship between CO2 flow rate and PetCO2 was found. Varying ventilator settings influenced the measurements, but the results for PetCO2 remained within a range of 1.5 mmHg above or under then mean measurement value. Measurements remained stable despite humidification, heat, pressure amplitudes or mean airway pressure changes. From this bench test, we conclude it is feasible to measure PetCO2 using a main stream capnograph during high frequency oscillatory conditions, these measurements were stable during the experiment. Changes in CO2 production or output can be detected. The system may prove to be of clinical value, but further in vivo measurements are warranted.
- 23 August 2013
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 28 (1) , 63-66
Bench test assessment of mainstream capnography during high frequency oscillatory ventilation
To assess the feasibility, stability and predictability of pCO2 measurement (PetCO2) using a main stream capnograph in a high frequency oscillatory ventilation circuit. A commercially available capnograph was mounted into a high frequency oscillatory ventilator patient circuit, adjustable CO2 flow was introduced into an artificial lung and the output of the CO2 sensor assessed under varying ventilator settings. Influence of oxygen content, pressures, heat and moisture were recorded. A linear relationship between CO2 flow rate and PetCO2 was found. Varying ventilator settings influenced the measurements, but the results for PetCO2 remained within a range of 1.5 mmHg above or under then mean measurement value. Measurements remained stable despite humidification, heat, pressure amplitudes or mean airway pressure changes. From this bench test, we conclude it is feasible to measure PetCO2 using a main stream capnograph during high frequency oscillatory conditions, these measurements were stable during the experiment. Changes in CO2 production or output can be detected. The system may prove to be of clinical value, but further in vivo measurements are warranted.
- Open Access
- 15 May 2009
- Published by Springer Nature in Critical Care
- Vol. 13 (3) , R71
Heliox reduces respiratory system resistance in respiratory syncytial virus induced respiratory failure
Introduction: Respiratory syncytial virus (RSV) lower respiratory tract disease is characterised by narrowing of the airways resulting in increased airway resistance, air-trapping and respiratory acidosis. These problems might be overcome using helium-oxygen gas mixture. However, the effect of mechanical ventilation with heliox in these patients is unclear. The objective of this prospective cross-over study was to determine the effects of mechanical ventilation with heliox 60/40 versus conventional gas on respiratory system resistance, air-trapping and CO2 removal. Methods: Mechanically ventilated, sedated and paralyzed infants with proven RSV were enrolled within 24 hours after paediatric intensive care unit (PICU)admission. At T = 0, respiratory system mechanics including respiratory system compliance and resistance, and peak expiratory flow rate were measured with the AVEA ventilator. The measurements were repeated at each interval (after 30 minutes of ventilation with heliox, after 30 minutes of ventilation with nitrox and again after 30 minutes of ventilation with heliox). Indices of gas exchange (ventilation and oxygenation index) were calculated at each interval. Air-trapping (defined by relative change in end-expiratory lung volume) was determined by electrical impedance tomography (EIT) at each interval. Results: Thirteen infants were enrolled. In nine, EIT measurements were performed. Mechanical ventilation with heliox significantly decreased respiratory system resistance. This was not accompanied by an improved CO2 elimination, decreased peak expiratory flow rate or decreased end-expiratory lung volume. Importantly, oxygenation remained unaltered throughout the experimental protocol. Conclusions: Respiratory system resistance is significantly decreased by mechanical ventilation with heliox (ISCRTN98152468).
- 15 May 2009
- Published by Springer Nature in Critical Care
- Vol. 13 (3) , R71
Open AccessHeliox reduces respiratory system resistance in respiratory syncytial virus induced respiratory failure
Introduction: Respiratory syncytial virus (RSV) lower respiratory tract disease is characterised by narrowing of the airways resulting in increased airway resistance, air-trapping and respiratory acidosis. These problems might be overcome using helium-oxygen gas mixture. However, the effect of mechanical ventilation with heliox in these patients is unclear. The objective of this prospective cross-over study was to determine the effects of mechanical ventilation with heliox 60/40 versus conventional gas on respiratory system resistance, air-trapping and CO2 removal. Methods: Mechanically ventilated, sedated and paralyzed infants with proven RSV were enrolled within 24 hours after paediatric intensive care unit (PICU)admission. At T = 0, respiratory system mechanics including respiratory system compliance and resistance, and peak expiratory flow rate were measured with the AVEA ventilator. The measurements were repeated at each interval (after 30 minutes of ventilation with heliox, after 30 minutes of ventilation with nitrox and again after 30 minutes of ventilation with heliox). Indices of gas exchange (ventilation and oxygenation index) were calculated at each interval. Air-trapping (defined by relative change in end-expiratory lung volume) was determined by electrical impedance tomography (EIT) at each interval. Results: Thirteen infants were enrolled. In nine, EIT measurements were performed. Mechanical ventilation with heliox significantly decreased respiratory system resistance. This was not accompanied by an improved CO2 elimination, decreased peak expiratory flow rate or decreased end-expiratory lung volume. Importantly, oxygenation remained unaltered throughout the experimental protocol. Conclusions: Respiratory system resistance is significantly decreased by mechanical ventilation with heliox (ISCRTN98152468).
- 1 January 2009
- Published by Taylor & Francis in Journal of Medical Engineering & Technology
- Vol. 33 (4) , 281-287
Assessing effects of PEEP and global expiratory lung volume on regional electrical impedance tomography
This study was performed to assess the value of electrical impedance tomography (EIT) as an indicator of tidal (V(T)) and end expiratory lung volume (EELV). EIT measurements were performed in seven healthy piglets during constant tidal volume ventilation at incremental and decremental positive end-expiratory pressure (PEEP) levels. Tidal impedance changes were calibrated to volume using V(T) calculated from flow at the airway opening. Simultaneously, calibrated respiratory inductive plethysmography was used to measure EELV changes, and used as a reference standard. EIT systematically underestimated both V(T) and EELV changes when EELV deviated from the level at which it was calibrated. Calculated over the entire pressure-volume curve, EIT systematically underestimated V(T) by 28 ml, with a precision from -16 to 72 ml. EELV was systemically underestimated by 406 ml, with a precision of -38 to 849 ml. Nonlinear recruitment in the ventral regions of the lungs was the main cause of this underestimation. Tidal and end-expiratory changes in pulmonary impedance reflect corresponding changes in lung volume, but the increasing underestimation with increasing lung volume should be taken into account in the analysis of EIT data.
- 1 January 2009
- Published by Taylor & Francis in Journal of Medical Engineering & Technology
- Vol. 33 (4) , 281-287
Assessing effects of PEEP and global expiratory lung volume on regional electrical impedance tomography
This study was performed to assess the value of electrical impedance tomography (EIT) as an indicator of tidal (V(T)) and end expiratory lung volume (EELV). EIT measurements were performed in seven healthy piglets during constant tidal volume ventilation at incremental and decremental positive end-expiratory pressure (PEEP) levels. Tidal impedance changes were calibrated to volume using V(T) calculated from flow at the airway opening. Simultaneously, calibrated respiratory inductive plethysmography was used to measure EELV changes, and used as a reference standard. EIT systematically underestimated both V(T) and EELV changes when EELV deviated from the level at which it was calibrated. Calculated over the entire pressure-volume curve, EIT systematically underestimated V(T) by 28 ml, with a precision from -16 to 72 ml. EELV was systemically underestimated by 406 ml, with a precision of -38 to 849 ml. Nonlinear recruitment in the ventral regions of the lungs was the main cause of this underestimation. Tidal and end-expiratory changes in pulmonary impedance reflect corresponding changes in lung volume, but the increasing underestimation with increasing lung volume should be taken into account in the analysis of EIT data.
- Open Access
- 19 March 2008
- Published by Springer Nature in Intensive Care Medicine
- Vol. 34 (8) , 1548-1550
Should strict normoglycaemia be maintained in critically ill children?
- 19 March 2008
- Published by Springer Nature in Intensive Care Medicine
- Vol. 34 (8) , 1548-1550
Open AccessShould strict normoglycaemia be maintained in critically ill children?
- 22 March 2007
- Published by BMJ in Archives of Disease in Childhood
- Vol. 92 (11) , 1038-1039
Should critically ill patients be routinely transfused to a normal haemoglobin level?
- 22 March 2007
- Published by BMJ in Archives of Disease in Childhood
- Vol. 92 (11) , 1038-1039
Should critically ill patients be routinely transfused to a normal haemoglobin level?
- Open Access
- 1 January 2007
- Published by Springer Nature in Critical Care
- Vol. 12 (1) , 408
The quest for optimal positive end-expiratory pressure continues
- 1 January 2007
- Published by Springer Nature in Critical Care
- Vol. 12 (1) , 408
Open AccessThe quest for optimal positive end-expiratory pressure continues
- Open Access
- 18 July 2006
- Published by Springer Nature in Critical Care
- Vol. 10 (4) , R103
Unloading work of breathing during high-frequency oscillatory ventilation: a bench study
Introduction: With the 3100B high-frequency oscillatory ventilator (SensorMedics, Yorba Linda, CA, USA), patients' spontaneous breathing efforts result in a high level of imposed work of breathing (WOB). Therefore, spontaneous breathing often has to be suppressed during high-frequency oscillatory ventilation (HFOV). A demand-flow system was designed to reduce imposed WOB. Methods: An external gas flow controller (demand-flow system) accommodates the ventilator fresh gas flow during spontaneous breathing simulation. A control algorithm detects breathing effort and regulates the demand-flow valve. The effectiveness of this system has been evaluated in a bench test. The Campbell diagram and pressure time product (PTP) are used to quantify the imposed workload. Results: Using the demand-flow system, imposed WOB is considerably reduced. The demand-flow system reduces inspiratory imposed WOB by 30% to 56% and inspiratory imposed PTP by 38% to 59% compared to continuous fresh gas flow. Expiratory imposed WOB was decreased as well by 12% to 49%. In simulations of shallow to normal breathing for an adult, imposed WOB is 0.5 J l-1 at maximum. Fluctuations in mean airway pressure on account of spontaneous breathing are markedly reduced. Conclusion: The use of the demand-flow system during HFOV results in a reduction of both imposed WOB and fluctuation in mean airway pressure. The level of imposed WOB was reduced to the physiological range of WOB. Potentially, this makes maintenance of spontaneous breathing during HFOV possible and easier in a clinical setting. Early initiation of HFOV seems more possible with this system and the possibility of weaning of patients directly on a high-frequency oscillatory ventilator is not excluded either.
- 18 July 2006
- Published by Springer Nature in Critical Care
- Vol. 10 (4) , R103
Open AccessUnloading work of breathing during high-frequency oscillatory ventilation: a bench study
Introduction: With the 3100B high-frequency oscillatory ventilator (SensorMedics, Yorba Linda, CA, USA), patients' spontaneous breathing efforts result in a high level of imposed work of breathing (WOB). Therefore, spontaneous breathing often has to be suppressed during high-frequency oscillatory ventilation (HFOV). A demand-flow system was designed to reduce imposed WOB. Methods: An external gas flow controller (demand-flow system) accommodates the ventilator fresh gas flow during spontaneous breathing simulation. A control algorithm detects breathing effort and regulates the demand-flow valve. The effectiveness of this system has been evaluated in a bench test. The Campbell diagram and pressure time product (PTP) are used to quantify the imposed workload. Results: Using the demand-flow system, imposed WOB is considerably reduced. The demand-flow system reduces inspiratory imposed WOB by 30% to 56% and inspiratory imposed PTP by 38% to 59% compared to continuous fresh gas flow. Expiratory imposed WOB was decreased as well by 12% to 49%. In simulations of shallow to normal breathing for an adult, imposed WOB is 0.5 J l-1 at maximum. Fluctuations in mean airway pressure on account of spontaneous breathing are markedly reduced. Conclusion: The use of the demand-flow system during HFOV results in a reduction of both imposed WOB and fluctuation in mean airway pressure. The level of imposed WOB was reduced to the physiological range of WOB. Potentially, this makes maintenance of spontaneous breathing during HFOV possible and easier in a clinical setting. Early initiation of HFOV seems more possible with this system and the possibility of weaning of patients directly on a high-frequency oscillatory ventilator is not excluded either.