Yoshifumi Saijo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Yoshifumi Saijo has a total of 135 co-authors. Here are the top co-authors by number of shared publications:
Motonao Tanaka
Cardiovascular Center, Tohoku Welfare Pension Hospital, Sendai, Japan
12 shared publicationsHidehiko Sasaki
11 shared publicationsShin-Ichi Nitta
8 shared publications- Tomoyuki Yambe
Tohoku University
8 shared publications Tomoyuki Yambe
7 shared publicationsKazuto Kobayashi
6 shared publications
Latest Publications
- Open Access
- 1 January 2017
- Published by Acoustical Society of America (ASA) in Proceedings of Meetings on Acoustics
- Vol. 32 (1) , 020018
Carbon nanotubes as potential candidate for photoacoustic imaging contrast agent
Photoacoustic (PA) imaging can visualize the biological objects with high contrast and high spatial resolution. The biological objects in PA imaging are not always good light-absorber. Moreover, the biological objects sometimes only absorb light with a specific wavelength. Correspondingly, the contrast agents are relatively needed in PA imaging. We present the application of carbon nanotube (CNT) for PA imaging contrast agent. We also provide the mathematical model to describe the temperature profile at CNT during laser irradiation. Theoretically, we showed that the maximum temperature during laser irradiation is proportional to the diameter of CNT. Additionally, our experimental results showed that the CNT has broad optical absorption in the visible-infrared regions. Furthermore, CNT gives high PA signal in compared with red ink even in the low-intensity of laser irradiation. These results extend our understanding of CNT for PA imaging contrast agent and provide the foundation for future PA imaging technology.
- 1 January 2017
- Published by Acoustical Society of America (ASA) in Proceedings of Meetings on Acoustics
- Vol. 32 (1) , 020018
Open AccessCarbon nanotubes as potential candidate for photoacoustic imaging contrast agent
Photoacoustic (PA) imaging can visualize the biological objects with high contrast and high spatial resolution. The biological objects in PA imaging are not always good light-absorber. Moreover, the biological objects sometimes only absorb light with a specific wavelength. Correspondingly, the contrast agents are relatively needed in PA imaging. We present the application of carbon nanotube (CNT) for PA imaging contrast agent. We also provide the mathematical model to describe the temperature profile at CNT during laser irradiation. Theoretically, we showed that the maximum temperature during laser irradiation is proportional to the diameter of CNT. Additionally, our experimental results showed that the CNT has broad optical absorption in the visible-infrared regions. Furthermore, CNT gives high PA signal in compared with red ink even in the low-intensity of laser irradiation. These results extend our understanding of CNT for PA imaging contrast agent and provide the foundation for future PA imaging technology.
- 1 October 2016
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 140 (4_Suppleme) , 3244
History of biomedical ultrasound microscope in Japan
Floyd Dunn greatly contributed to the history of biomedical ultrasound microscope (USM) in Japan. Ten years after the concept of ultrasound microscope was proposed by Sokolov of Soviet Union, he realized the ultrasound absorption microscope in 1959. During the time he directed the Bioacoustics Research Laboratory at the University of Illinois, many Japanese researches stayed in his laboratory. Especially, the researchers from Tohoku University learned both technology and philosophy of USM and they started development of scanning acoustic microscopy for medicine and biology in 1982. The USM system had been used for nearly 30 years until the Great East Japan Earthquake destroyed the system. Not only USM, other high frequency ultrasound imaging was also developed in 1990s. Especially, clinical application of intravascular ultrasound filled a gap between several MHz ultrasound used in conventional B-mode and 100 MHz used in USM. High frequency technology and computer science helped developing new generation USM such as ultrasound impedance microscope and 3D ultrasound microscope. Now the application area is spread and Biomedical Ultrasound Microscope Conference is biannually held in Japan. Now, we thank Floyd again for the fruitful activity of USM in Japan.
- 1 October 2016
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 140 (4_Suppleme) , 3244
History of biomedical ultrasound microscope in Japan
Floyd Dunn greatly contributed to the history of biomedical ultrasound microscope (USM) in Japan. Ten years after the concept of ultrasound microscope was proposed by Sokolov of Soviet Union, he realized the ultrasound absorption microscope in 1959. During the time he directed the Bioacoustics Research Laboratory at the University of Illinois, many Japanese researches stayed in his laboratory. Especially, the researchers from Tohoku University learned both technology and philosophy of USM and they started development of scanning acoustic microscopy for medicine and biology in 1982. The USM system had been used for nearly 30 years until the Great East Japan Earthquake destroyed the system. Not only USM, other high frequency ultrasound imaging was also developed in 1990s. Especially, clinical application of intravascular ultrasound filled a gap between several MHz ultrasound used in conventional B-mode and 100 MHz used in USM. High frequency technology and computer science helped developing new generation USM such as ultrasound impedance microscope and 3D ultrasound microscope. Now the application area is spread and Biomedical Ultrasound Microscope Conference is biannually held in Japan. Now, we thank Floyd again for the fruitful activity of USM in Japan.
- 1 October 2016
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 140 (4_Suppleme) , 3027-3028
Two-dimensional blood flow vector obtained with high frame rate acquisition of dual-angle Doppler signal
Quantitative measurement of flow in blood vessels is important to assess cardiovascular dynamics. The objective of the present study is to obtain two-dimensional (2D) blood flow vector in some carotid artery models and to validate the method in comparison with particle image velocimetry (PIV). Plane wave ultrasound with the repetition rate of 14 kHz was transmitted and received by a 7.5 MHz linear array transducer and a programmable ultrasound data acquisition system. Compound B-mode images and dual-angle Doppler data with the transmission angle of -10° and + 10° were obtained. 2D flow vector at arbitrary point was calculated by two velocity components along with each angle. Steady and pulsatile flow in normal and stenosed carotid artery models were simultaneously observed by the proposed method and PIV. 2D velocity vectors were successfully obtained in each flow states and the average error was approximately 5% in comparison with PIV in the carotid artery model. Steady flow in the distal stenosis model showed that the blood flow was influenced by vascular resistance while pulsatile flow seemed to push the blood to the high resistance portion. 2D blood flow obtained with dual-angle Doppler signal may provide important information in understanding cardiovascular dynamics.
- 1 October 2016
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 140 (4_Suppleme) , 3027-3028
Two-dimensional blood flow vector obtained with high frame rate acquisition of dual-angle Doppler signal
Quantitative measurement of flow in blood vessels is important to assess cardiovascular dynamics. The objective of the present study is to obtain two-dimensional (2D) blood flow vector in some carotid artery models and to validate the method in comparison with particle image velocimetry (PIV). Plane wave ultrasound with the repetition rate of 14 kHz was transmitted and received by a 7.5 MHz linear array transducer and a programmable ultrasound data acquisition system. Compound B-mode images and dual-angle Doppler data with the transmission angle of -10° and + 10° were obtained. 2D flow vector at arbitrary point was calculated by two velocity components along with each angle. Steady and pulsatile flow in normal and stenosed carotid artery models were simultaneously observed by the proposed method and PIV. 2D velocity vectors were successfully obtained in each flow states and the average error was approximately 5% in comparison with PIV in the carotid artery model. Steady flow in the distal stenosis model showed that the blood flow was influenced by vascular resistance while pulsatile flow seemed to push the blood to the high resistance portion. 2D blood flow obtained with dual-angle Doppler signal may provide important information in understanding cardiovascular dynamics.
- 1 October 2016
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 140 (4_Suppleme) , 2979
Skin vasculature imaging by acoustical resolution photoacoustic microscope with parabolic array transducer
Photoacoustic (PA) signal is highly dependent on the structure of the target. In the present study, PA imaging system with parabolic array transducer for multi-angle detection is developed and the skin vasculature is observed. The transducer was consisted of 256 ch 1-3-composite elements with the center frequency of 10 MHz. The diameter was 42.4 mm and the opening angle was 90 degree. A hole was made in the center of the transducer for transmission of the laser. PA signal was acquired by a programmable ultrasound data acquisition system with the sampling frequency of 60 MHz. A diode laser with the wavelength of 532 nm, pulse width of 8 ns, pulse energy of 5 mJ, and repetition frequency of 10 Hz was equipped for generation of PA signal. Three dimensional image was reconstructed by delay-and-sum beamforming of PA signals received by all channels. The frame rate for displaying x-y, y-z, and x-z images was 10 Hz, and the full width at half maximum (FWHM) of the x-z image was 70 μm. 3D structure of the skin capillary network of a human hand was successfully observed by the system. The system may contribute to the peripheral blood circulation.
- 1 October 2016
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 140 (4_Suppleme) , 2979
Skin vasculature imaging by acoustical resolution photoacoustic microscope with parabolic array transducer
Photoacoustic (PA) signal is highly dependent on the structure of the target. In the present study, PA imaging system with parabolic array transducer for multi-angle detection is developed and the skin vasculature is observed. The transducer was consisted of 256 ch 1-3-composite elements with the center frequency of 10 MHz. The diameter was 42.4 mm and the opening angle was 90 degree. A hole was made in the center of the transducer for transmission of the laser. PA signal was acquired by a programmable ultrasound data acquisition system with the sampling frequency of 60 MHz. A diode laser with the wavelength of 532 nm, pulse width of 8 ns, pulse energy of 5 mJ, and repetition frequency of 10 Hz was equipped for generation of PA signal. Three dimensional image was reconstructed by delay-and-sum beamforming of PA signals received by all channels. The frame rate for displaying x-y, y-z, and x-z images was 10 Hz, and the full width at half maximum (FWHM) of the x-z image was 70 μm. 3D structure of the skin capillary network of a human hand was successfully observed by the system. The system may contribute to the peripheral blood circulation.
- Open Access
- 19 September 2015
- Published by Elsevier in Physics Procedia
- Vol. 70, 1161-1164
Adaptive Spatial Filtering with Principal Component Analysis for Biomedical Photoacoustic Imaging
- 19 September 2015
- Published by Elsevier in Physics Procedia
- Vol. 70, 1161-1164
Open AccessAdaptive Spatial Filtering with Principal Component Analysis for Biomedical Photoacoustic Imaging
- 20 August 2015
- Published by Springer Nature in Journal of Medical Ultrasonics
- Vol. 42 (4) , 605
In memory: Floyd Dunn
- 20 August 2015
- Published by Springer Nature in Journal of Medical Ultrasonics
- Vol. 42 (4) , 605
In memory: Floyd Dunn
- Open Access
- 25 January 2015
- Published by Institute of Industrial Applications Engineers in Journal of the Institute of Industrial Applications Engineers
- Vol. 3 (1) , 1-5
Detection of Abnormal Blood Vessels on Optic Disc for Diagnosis of Proliferative Diabetic Retinopathy
- 25 January 2015
- Published by Institute of Industrial Applications Engineers in Journal of the Institute of Industrial Applications Engineers
- Vol. 3 (1) , 1-5
Open AccessDetection of Abnormal Blood Vessels on Optic Disc for Diagnosis of Proliferative Diabetic Retinopathy
- 26 September 2013
- Published by Springer Nature
- p. 291-313
Recent Applications of Acoustic Microscopy for Quantitative Measurement of Acoustic Properties of Soft Tissues
- 26 September 2013
- Published by Springer Nature
- p. 291-313
Recent Applications of Acoustic Microscopy for Quantitative Measurement of Acoustic Properties of Soft Tissues
- 1 May 2013
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 133 (5) , 3260
Speed of sound of fatty and fibrosis liver measured by 80-MHz and 250-MHz scanning acoustic microscopy
Early detection of hepatitis is critical for proper patient management and improving disease prognosis. Ultrasound imaging is ideally suited for early-stage assessments, but conventional ultrasound images based on backscatter do not display quantitative tissue information because conventional ultrasound lacks essential modeling of the complex interaction between ultrasound and liver tissue in normal and diseased states. Therefore, speed-of-sound (SOS) measurements were obtained from three types of rat livers (normal, fatty, and fibrosis). Livers were harvested, fixed, and embedded in paraffin; a single 10-µm thin section was obtained using a microtome and placed on a microscope slide. A scanning acoustic microscope incorporating transducers operating at 80- and 250-MHz center frequencies was used to scan the 10-µm section. An adjacent 4-µm thin section was stained with H&E (normal and fatty livers) or Azan (fibrosis livers). The SOS measured with both transducers displayed the same trend: SOS in fatty liver was lower than in normal liver and SOS in fibrosis liver was higher than in normal liver. SOS differences were greater at 250 MHz because of the improved spatial resolution, which allowed choosing region-of-interests containing only fat or fibrosis tissue. These initial results also were used to correlate the pathologic state with the SOS.
- 1 May 2013
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 133 (5) , 3260
Speed of sound of fatty and fibrosis liver measured by 80-MHz and 250-MHz scanning acoustic microscopy
Early detection of hepatitis is critical for proper patient management and improving disease prognosis. Ultrasound imaging is ideally suited for early-stage assessments, but conventional ultrasound images based on backscatter do not display quantitative tissue information because conventional ultrasound lacks essential modeling of the complex interaction between ultrasound and liver tissue in normal and diseased states. Therefore, speed-of-sound (SOS) measurements were obtained from three types of rat livers (normal, fatty, and fibrosis). Livers were harvested, fixed, and embedded in paraffin; a single 10-µm thin section was obtained using a microtome and placed on a microscope slide. A scanning acoustic microscope incorporating transducers operating at 80- and 250-MHz center frequencies was used to scan the 10-µm section. An adjacent 4-µm thin section was stained with H&E (normal and fatty livers) or Azan (fibrosis livers). The SOS measured with both transducers displayed the same trend: SOS in fatty liver was lower than in normal liver and SOS in fibrosis liver was higher than in normal liver. SOS differences were greater at 250 MHz because of the improved spatial resolution, which allowed choosing region-of-interests containing only fat or fibrosis tissue. These initial results also were used to correlate the pathologic state with the SOS.
- 28 February 2013
- Published by Elsevier in Journal of Dermatological Science
- Vol. 69 (2) , e50-e51
Facial sebaceous gland size determined by three-dimensional ultrasound tomography correlates with skin elasticity
- 28 February 2013
- Published by Elsevier in Journal of Dermatological Science
- Vol. 69 (2) , e50-e51
Facial sebaceous gland size determined by three-dimensional ultrasound tomography correlates with skin elasticity