Tomoyuki Yambe
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Tomoyuki Yambe has a total of 243 co-authors. Here are the top co-authors by number of shared publications:
Akira Tanaka
Tohoku University, Sendai 980-8575, Japan
22 shared publicationsMakoto Yoshizawa
Tohoku University, Sendai
21 shared publicationsKouichi Tabayashi
14 shared publicationsShin-Ichi Nitta
Department of Medical Engineering and Cardiology, Institute of Development, Aging and Cancer, Tohoku University, Sendai
13 shared publicationsS. Nitta
Tohoku University
10 shared publications- Yasuyuki Shiraishi
Tohoku University
10 shared publications
Latest Publications
- Open Access
The Pilot Study of Evaluating Fluctuation in the Blood Flow Volume of the Radial Artery, a Site for Traditional Pulse Diagnosis
Background: Radial artery (RA) pulse diagnosis has been used in traditional Asian medicine. Blood pressure (BP) and pulse rate related to heart rate variability (HRV) can be monitored via the RA. The fluctuation in these parameters has been assessed using fast Fourier transform (FFT) analytical methods that calculate power spectra. Methods: We measured blood flow volume (Volume) in the RA and evaluated its fluctuations. Normal participants (n = 34) were enrolled. We measured the hemodynamics of the right RA for approximately 50 s using ultrasonography. Results: The parameters showed the center frequency (CF) of the power spectrum at low frequency (LF) and high frequency (HF). More than one spectral component indicated that there were fluctuations. The CF at LF for Volume was significantly different from that for vessel diameter (VD); however, it was significantly correlated with blood flow velocity (Velocity). On the other hand, the CF at HF for Volume was significantly different from that for Velocity; however, it was significantly correlated with VD. Conclusion: It is suggested that fluctuation in the Volume at LF of RA is influenced by the fluctuation in Velocity; on the other hand, fluctuation in the Volume at HF is influenced by the fluctuation in VD.
Open AccessThe Pilot Study of Evaluating Fluctuation in the Blood Flow Volume of the Radial Artery, a Site for Traditional Pulse Diagnosis
Background: Radial artery (RA) pulse diagnosis has been used in traditional Asian medicine. Blood pressure (BP) and pulse rate related to heart rate variability (HRV) can be monitored via the RA. The fluctuation in these parameters has been assessed using fast Fourier transform (FFT) analytical methods that calculate power spectra. Methods: We measured blood flow volume (Volume) in the RA and evaluated its fluctuations. Normal participants (n = 34) were enrolled. We measured the hemodynamics of the right RA for approximately 50 s using ultrasonography. Results: The parameters showed the center frequency (CF) of the power spectrum at low frequency (LF) and high frequency (HF). More than one spectral component indicated that there were fluctuations. The CF at LF for Volume was significantly different from that for vessel diameter (VD); however, it was significantly correlated with blood flow velocity (Velocity). On the other hand, the CF at HF for Volume was significantly different from that for Velocity; however, it was significantly correlated with VD. Conclusion: It is suggested that fluctuation in the Volume at LF of RA is influenced by the fluctuation in Velocity; on the other hand, fluctuation in the Volume at HF is influenced by the fluctuation in VD.
- 1 January 2016
- Published by Japan Society of Mechanical Engineers in Journal of Biomechanical Science and Engineering
- Vol. 11 (3) , 15-00356
Effect of right atrial contraction on prosthetic valve function in a mechanical pulmonary circulatory system
- 1 January 2016
- Published by Japan Society of Mechanical Engineers in Journal of Biomechanical Science and Engineering
- Vol. 11 (3) , 15-00356
Effect of right atrial contraction on prosthetic valve function in a mechanical pulmonary circulatory system
- 18 April 2015
- Published by Springer Nature in Journal of Artificial Organs
- Vol. 18 (3) , 199-205
Development of a thermodynamic control system for the Fontan circulation pulsation device using shape memory alloy fibers
The Fontan procedure is one of the common surgical treatments for circulatory reconstruction in pediatric patients with congenital heart disease. In Fontan circulation, low pulsatility may induce localized lung ischemia and may impair the development of pulmonary peripheral endothelial cells. To promote pulmonary circulation in Fontan circulation, we have been developing a pediatric pulmonary circulatory pulsation device using shape memory alloy fibers attached from the outside of total cavopulmonary connection. In this study, we developed a new thermal control system for the device and examined its functions. We mounted on the device 16 fibers connected in parallel around an ePTFE graft circumferentially. To provide optimized contraction, we designed the new thermal control system. The system consisted of a thermistor, a pressure sensor, and a regulator that was controlled by the adaptive thermodynamic transfer functions. We monitored the parameters and calculated heat transfer function as well as pressure distribution on the graft surface. Then we examined and compared the dynamic contractile pressure and changes in surface temperature. As a result, by the application of the control based on the new feedback system analysis, the circumferential contractile pressure increased by 35 %. The adaptive thermodynamic regulation was useful for the selection of alternative thresholds of the surface temperature of the graft. The system could achieve effective contraction for the pulsatile flow generation by the device.
- 18 April 2015
- Published by Springer Nature in Journal of Artificial Organs
- Vol. 18 (3) , 199-205
Development of a thermodynamic control system for the Fontan circulation pulsation device using shape memory alloy fibers
The Fontan procedure is one of the common surgical treatments for circulatory reconstruction in pediatric patients with congenital heart disease. In Fontan circulation, low pulsatility may induce localized lung ischemia and may impair the development of pulmonary peripheral endothelial cells. To promote pulmonary circulation in Fontan circulation, we have been developing a pediatric pulmonary circulatory pulsation device using shape memory alloy fibers attached from the outside of total cavopulmonary connection. In this study, we developed a new thermal control system for the device and examined its functions. We mounted on the device 16 fibers connected in parallel around an ePTFE graft circumferentially. To provide optimized contraction, we designed the new thermal control system. The system consisted of a thermistor, a pressure sensor, and a regulator that was controlled by the adaptive thermodynamic transfer functions. We monitored the parameters and calculated heat transfer function as well as pressure distribution on the graft surface. Then we examined and compared the dynamic contractile pressure and changes in surface temperature. As a result, by the application of the control based on the new feedback system analysis, the circumferential contractile pressure increased by 35 %. The adaptive thermodynamic regulation was useful for the selection of alternative thresholds of the surface temperature of the graft. The system could achieve effective contraction for the pulsatile flow generation by the device.
- 1 January 2015
- Published by Japan Society of Mechanical Engineers in The Proceedings of the Asian Pacific Conference on Biomechanics : emerging science and technology in biomechanics
- Vol. 2015.8
PS1-4 Evaluation of frozen vascular grafts by using MRE : how to keep the characteristics of bioprostheses?(PS1: Poster Short Presentation I,Poster Session)
- 1 January 2015
- Published by Japan Society of Mechanical Engineers in The Proceedings of the Asian Pacific Conference on Biomechanics : emerging science and technology in biomechanics
- Vol. 2015.8
PS1-4 Evaluation of frozen vascular grafts by using MRE : how to keep the characteristics of bioprostheses?(PS1: Poster Short Presentation I,Poster Session)
- 6 March 2013
- Published by IntechOpen
High-Tech Equipment for Moxibustion in Modern Medicine
- 14 January 2013
- Published by Springer Nature in MRS Proceedings
- Vol. 1498, 103-108
Investigation of biocompatibility on nitrogen-doped a-C:H film coating scaffold surface in in-vivo and in-vitro tests
- 14 January 2013
- Published by Springer Nature in MRS Proceedings
- Vol. 1498, 103-108
Investigation of biocompatibility on nitrogen-doped a-C:H film coating scaffold surface in in-vivo and in-vitro tests
- 6 August 2012
- Published by Wiley in Artificial Organs
- Vol. 36 (8) , 760-763
Medical Responses Following the Sendai Quake (East Japan Earthquake, March 11, 2011)
- 6 August 2012
- Published by Wiley in Artificial Organs
- Vol. 36 (8) , 760-763
Medical Responses Following the Sendai Quake (East Japan Earthquake, March 11, 2011)
- 1 August 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2012 (1094687X) , 5741-5744
New implantable therapeutic device for the control of an atrial fibrillation attack using the Peltier element
For the development of the new therapeutic device for the atrial fibrillation, implantable cooling device using Peltier element was developed in this study. An implantable cooling device had been consisted from Peltier element with transcutaneous energy transmission system (TETS). 1st coil can be contacted from outside of the body, when the patients will feel palpitation. Electrical current will be induced to the implanted 2nd coil. Peltier element will able to cool the surface of the atrium. For the confirmation of the effect of the cooling device, trial manufacture model was developed. Animal experiments using six healthy adult goats after animal ethical committee allowance was carried out. Fourth intercostals space had been opened after anesthesia inhalation, and various sensors had been inserted. AF was induced by the electrical current with battery. As the results, AF had been recovered to the normal sinus rhythm after cooling in all six goats. So, this cooling system for the control of AF showed evident effect in these experiments. Smaller size cooling device has been under development aiming at totally implantable type. Catheter type cooling device for the insertion by the use of fiber-scope type is now under planning for the clinical application. This new type device may be able to become good news for the patients with uncontrollable AF.
- 1 August 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2012 (1094687X) , 5741-5744
New implantable therapeutic device for the control of an atrial fibrillation attack using the Peltier element
For the development of the new therapeutic device for the atrial fibrillation, implantable cooling device using Peltier element was developed in this study. An implantable cooling device had been consisted from Peltier element with transcutaneous energy transmission system (TETS). 1st coil can be contacted from outside of the body, when the patients will feel palpitation. Electrical current will be induced to the implanted 2nd coil. Peltier element will able to cool the surface of the atrium. For the confirmation of the effect of the cooling device, trial manufacture model was developed. Animal experiments using six healthy adult goats after animal ethical committee allowance was carried out. Fourth intercostals space had been opened after anesthesia inhalation, and various sensors had been inserted. AF was induced by the electrical current with battery. As the results, AF had been recovered to the normal sinus rhythm after cooling in all six goats. So, this cooling system for the control of AF showed evident effect in these experiments. Smaller size cooling device has been under development aiming at totally implantable type. Catheter type cooling device for the insertion by the use of fiber-scope type is now under planning for the clinical application. This new type device may be able to become good news for the patients with uncontrollable AF.
- 29 September 2011
- Published by American Society of Hematology in Blood
- Vol. 118 (13) , e93-e100
In vivo imaging of the molecular distribution of the VEGF receptor during angiogenesis in a mouse model of ischemia
Vascular endothelial growth factor (VEGF) plays a critical role in angiogenesis and has been applied to medical therapy. However, because vascular imaging at the molecular level is impossible, the detailed in vivo dynamics of VEGF and its receptor (VEGFR) remain unknown. In this study, to understand the molecular distribution of VEGF and the VEGFR, we prepared ischemic mice with a new surgical method and induced angiogenesis in the gastrocnemius muscle. Then, we made a VEGF-conjugated fluorescence nanoparticle and performed staining of VEGFR-expressing cells with the fluorescent probe, demonstrating the high affinity of the probe for VEGFR. To observe the physiologic molecular distribution of VEGFR, we performed in vivo single-particle imaging of gastrocnemius in the ischemic leg with the fluorescent probe. The results suggested that only a 3-fold difference of VEGFR distribution is involved in the formation of branched vasculature in angiogenesis, although previous ex vivo data showed a 13-fold difference in its distribution, indicating that a method inducing a several-fold local increase of VEGFR concentration may be effective in generating site-specific angiogenesis in ischemic disease. This new in vivo imaging of ischemic mice could make useful contributions to understanding the mechanisms of angiogenesis and to developing a VEGFR-related drug.
- 29 September 2011
- Published by American Society of Hematology in Blood
- Vol. 118 (13) , e93-e100
In vivo imaging of the molecular distribution of the VEGF receptor during angiogenesis in a mouse model of ischemia
Vascular endothelial growth factor (VEGF) plays a critical role in angiogenesis and has been applied to medical therapy. However, because vascular imaging at the molecular level is impossible, the detailed in vivo dynamics of VEGF and its receptor (VEGFR) remain unknown. In this study, to understand the molecular distribution of VEGF and the VEGFR, we prepared ischemic mice with a new surgical method and induced angiogenesis in the gastrocnemius muscle. Then, we made a VEGF-conjugated fluorescence nanoparticle and performed staining of VEGFR-expressing cells with the fluorescent probe, demonstrating the high affinity of the probe for VEGFR. To observe the physiologic molecular distribution of VEGFR, we performed in vivo single-particle imaging of gastrocnemius in the ischemic leg with the fluorescent probe. The results suggested that only a 3-fold difference of VEGFR distribution is involved in the formation of branched vasculature in angiogenesis, although previous ex vivo data showed a 13-fold difference in its distribution, indicating that a method inducing a several-fold local increase of VEGFR concentration may be effective in generating site-specific angiogenesis in ischemic disease. This new in vivo imaging of ischemic mice could make useful contributions to understanding the mechanisms of angiogenesis and to developing a VEGFR-related drug.
- 3 January 2011
- Published by Wiley in Heat Transfer
- Vol. 40 (2) , 114-124
Thermal therapy and evaluation by a precise temperature control device
- 3 January 2011
- Published by Wiley in Heat Transfer
- Vol. 40 (2) , 114-124
Thermal therapy and evaluation by a precise temperature control device