Martijn G. Schouten
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Martijn G. Schouten has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
Dennis Bosboom
Department of Radiology, Radboud University Nijmegen Medical Centre, Nijmegen, Netherlands
2 shared publicationsJurgen J. Fütterer
Department of Radiology, Radboud University Nijmegen Medical Centre, Nijmegen, Netherlands
2 shared publicationsTom W. J. Scheenen
Department of Radiology, Radboud University Nijmegen Medical Centre, Nijmegen, Netherlands
2 shared publications- Derya Yakar
Department of Radiology, Netherlands Cancer Institute, Amsterdam, The Netherlands
1 shared publication Eva Rothgang
Pattern Recognition Lab, Friedrich-Alexander-University of Erlangen-Nuremberg, Erlangen, Germany
1 shared publication- Henkjan Huisman
Diagnostic Image Analysis Group, Department of Medical Imaging, Radboud University Medical Center, Geert Grooteplein Zuid 10, 6525 GA Nijmegen, the Netherlands
1 shared publication
Latest Publications
- Open Access
- 29 September 2011
- Published by Springer Nature in European Radiology
- Vol. 22 (2) , 476-483
Evaluation of a robotic technique for transrectal MRI-guided prostate biopsies
Objectives To evaluate the accuracy and speed of a novel robotic technique as an aid to perform magnetic resonance image (MRI)-guided prostate biopsies on patients with cancer suspicious regions. Methods A pneumatic controlled MR-compatible manipulator with 5 degrees of freedom was developed in-house to guide biopsies under real-time imaging. From 13 consecutive biopsy procedures, the targeting error, biopsy error and target displacement were calculated to evaluate the accuracy. The time was recorded to evaluate manipulation and procedure time. Results The robotic and manual techniques demonstrated comparable results regarding mean targeting error (5.7 vs 5.8 mm, respectively) and mean target displacement (6.6 vs 6.0 mm, respectively). The mean biopsy error was larger (6.5 vs 4.4 mm) when using the robotic technique, although not significant. Mean procedure and manipulation time were 76 min and 6 min, respectively using the robotic technique and 61 and 8 min with the manual technique. Conclusions Although comparable results regarding accuracy and speed were found, the extended technical effort of the robotic technique make the manual technique – currently – more suitable to perform MRI-guided biopsies. Furthermore, this study provided a better insight in displacement of the target during in vivo biopsy procedures.
- 29 September 2011
- Published by Springer Nature in European Radiology
- Vol. 22 (2) , 476-483
Open AccessEvaluation of a robotic technique for transrectal MRI-guided prostate biopsies
Objectives To evaluate the accuracy and speed of a novel robotic technique as an aid to perform magnetic resonance image (MRI)-guided prostate biopsies on patients with cancer suspicious regions. Methods A pneumatic controlled MR-compatible manipulator with 5 degrees of freedom was developed in-house to guide biopsies under real-time imaging. From 13 consecutive biopsy procedures, the targeting error, biopsy error and target displacement were calculated to evaluate the accuracy. The time was recorded to evaluate manipulation and procedure time. Results The robotic and manual techniques demonstrated comparable results regarding mean targeting error (5.7 vs 5.8 mm, respectively) and mean target displacement (6.6 vs 6.0 mm, respectively). The mean biopsy error was larger (6.5 vs 4.4 mm) when using the robotic technique, although not significant. Mean procedure and manipulation time were 76 min and 6 min, respectively using the robotic technique and 61 and 8 min with the manual technique. Conclusions Although comparable results regarding accuracy and speed were found, the extended technical effort of the robotic technique make the manual technique – currently – more suitable to perform MRI-guided biopsies. Furthermore, this study provided a better insight in displacement of the target during in vivo biopsy procedures.
- 17 August 2010
- Published by Wiley in Medical Physics
- Vol. 37 (9) , 4744-4750
The accuracy and safety aspects of a novel robotic needle guide manipulator to perform transrectal prostate biopsies
Purpose: To introduce a new in‐house developed pneumatically controlled magnetic field compatible manipulator as an aid to perform magnetic resonance (MR)‐guided biopsies of the prostate.Methods: A pneumatic controlled manipulator with five degrees of freedom constructed of plastic to achieve magnetic field compatibility was developed to guide biopsies. A risk analysis, mechanical tests, and RF safety tests with respect to needle tip heating were performed to assure future patient safety and to meet standard safety requirements for the use in a medical environment. The accuracy of needle positioning with the needle guide manipulator to sample a predefined target was measured in agar phantoms on a 3 T whole body MR system. The in‐plane error was used to evaluate the accuracy, which is defined as the orthogonal distance between target and biopsy needle. The time for each step in the biopsy procedure was recorded to evaluate the procedure time. The influence of the insertion angle with respect to the static field of the MR scanner on the needle artifact was investigated.Results: The risk analyses met patient safety requirements. No RF induced local heating around the needle tip was observed. The average in‐plane error in 19 measurements was 3.0 mm (range 0–5.6 mm). The average time needed for manipulation to place the needle guide in the desired position was 5 min (range 3–8 min). Total procedure time was 30 min. The needle artifact size increases with the insertion angle with respect to the static field of the MR scanner.Conclusions: The new MR compatible manipulator can be used safely for patient care. It showed a high accuracy and short total procedure time, demonstrating great potential to improve the transrectal prostate biopsy procedure.
- 17 August 2010
- Published by Wiley in Medical Physics
- Vol. 37 (9) , 4744-4750
The accuracy and safety aspects of a novel robotic needle guide manipulator to perform transrectal prostate biopsies
Purpose: To introduce a new in‐house developed pneumatically controlled magnetic field compatible manipulator as an aid to perform magnetic resonance (MR)‐guided biopsies of the prostate.Methods: A pneumatic controlled manipulator with five degrees of freedom constructed of plastic to achieve magnetic field compatibility was developed to guide biopsies. A risk analysis, mechanical tests, and RF safety tests with respect to needle tip heating were performed to assure future patient safety and to meet standard safety requirements for the use in a medical environment. The accuracy of needle positioning with the needle guide manipulator to sample a predefined target was measured in agar phantoms on a 3 T whole body MR system. The in‐plane error was used to evaluate the accuracy, which is defined as the orthogonal distance between target and biopsy needle. The time for each step in the biopsy procedure was recorded to evaluate the procedure time. The influence of the insertion angle with respect to the static field of the MR scanner on the needle artifact was investigated.Results: The risk analyses met patient safety requirements. No RF induced local heating around the needle tip was observed. The average in‐plane error in 19 measurements was 3.0 mm (range 0–5.6 mm). The average time needed for manipulation to place the needle guide in the desired position was 5 min (range 3–8 min). Total procedure time was 30 min. The needle artifact size increases with the insertion angle with respect to the static field of the MR scanner.Conclusions: The new MR compatible manipulator can be used safely for patient care. It showed a high accuracy and short total procedure time, demonstrating great potential to improve the transrectal prostate biopsy procedure.