Tormod Selbekk
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Tormod Selbekk has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Ole Solheim
Norwegian University of Science and Technology Department of Neuromedicine and Movement Science, Faculty of Medicine and Health Sciences Trondheim
5 shared publications - Asgeir Store Jakola
Department of Clinical Neuroscience, Institute of Neuroscience and Physiology, Sahlgrenska Academy, University of Gothenburg , Gothenburg
3 shared publications - Geirmund Unsgård
Department of Neurosurgery, St. Olav University Hospital
3 shared publications - Ingerid Reinertsen
Department of Health Research, SINTEF Digital, NO-7465 Trondheim, Norway
3 shared publications Geirmund Unsgaard
2 shared publications- Arve Jørgensen
Department of Circulation and Medical Imaging, Norwegian University of Science and Technology, Trondheim, Norway; Department of Diagnostic Imaging, St. Olavs University Hospital, Trondheim, Norway
1 shared publication
Latest Publications
- 1 September 2014
- Published by Elsevier in World Neurosurgery
- Vol. 82 (3-4) , 536.e5-536.e9
Three-Dimensional Ultrasound–Guided Placement of Ventricular Catheters
- 1 September 2014
- Published by Elsevier in World Neurosurgery
- Vol. 82 (3-4) , 536.e5-536.e9
Three-Dimensional Ultrasound–Guided Placement of Ventricular Catheters
- Open Access
- 12 July 2014
- Published by Springer Nature
- p. 209-218
Registration of MR to Percutaneous Ultrasound of the Spine for Image-Guided Surgery
- 12 July 2014
- Published by Springer Nature
- p. 209-218
Open AccessRegistration of MR to Percutaneous Ultrasound of the Spine for Image-Guided Surgery
- Open Access
- 25 March 2014
- Published by Springer Nature in BMC Medical Imaging
- Vol. 14 (1) , 11
Animal study assessing safety of an acoustic coupling fluid that holds the potential to avoid surgically induced artifacts in 3D ultrasound guided operations
Use of ultrasound in brain tumor surgery is common. The difference in attenuation between brain and isotonic saline may cause artifacts that degrade the ultrasound images, potentially affecting resection grades and safety. Our research group has developed an acoustic coupling fluid that attenuates ultrasound energy like the normal brain. We aimed to test in animals if the newly developed acoustic coupling fluid may have harmful effects.
- 25 March 2014
- Published by Springer Nature in BMC Medical Imaging
- Vol. 14 (1) , 11
Open AccessAnimal study assessing safety of an acoustic coupling fluid that holds the potential to avoid surgically induced artifacts in 3D ultrasound guided operations
Use of ultrasound in brain tumor surgery is common. The difference in attenuation between brain and isotonic saline may cause artifacts that degrade the ultrasound images, potentially affecting resection grades and safety. Our research group has developed an acoustic coupling fluid that attenuates ultrasound energy like the normal brain. We aimed to test in animals if the newly developed acoustic coupling fluid may have harmful effects.
- Open Access
- 5 March 2013
- Published by Springer Nature in Acta Neurochirurgica
- Vol. 155 (6) , 973-980
Ultrasound imaging in neurosurgery: approaches to minimize surgically induced image artefacts for improved resection control
Background Intraoperative ultrasound imaging is used in brain tumor surgery to identify tumor remnants. The ultrasound images may in some cases be more difficult to interpret in the later stages of the operation than in the beginning of the operation. The aim of this paper is to explain the causes of surgically induced ultrasound artefacts and how they can be recognized and reduced. Methods The theoretical reasons for artefacts are addressed and the impact of surgery is discussed. Different setups for ultrasound acquisition and different acoustic coupling fluids to fill up the resection cavity are evaluated with respect to improved image quality. Results The enhancement artefact caused by differences in attenuation of the resection cavity fluid and the surrounding brain is the most dominating surgically induced ultrasound artefact. The influence of the artefact may be reduced by inserting ultrasound probes with small footprint into the resection cavity for a close-up view of the areas with suspected tumor remnants. A novel acoustic coupling fluid developed for use during ultrasound imaging in brain tumor surgery has the potential to reduce surgically induced ultrasound artefacts to a minimum. Conclusions Surgeons should be aware of artefacts in ultrasound images that may occur during brain tumor surgery. Techniques to identify and reduce image artefacts are useful and should be known to users of ultrasound in brain tumor surgery.
- 5 March 2013
- Published by Springer Nature in Acta Neurochirurgica
- Vol. 155 (6) , 973-980
Open AccessUltrasound imaging in neurosurgery: approaches to minimize surgically induced image artefacts for improved resection control
Background Intraoperative ultrasound imaging is used in brain tumor surgery to identify tumor remnants. The ultrasound images may in some cases be more difficult to interpret in the later stages of the operation than in the beginning of the operation. The aim of this paper is to explain the causes of surgically induced ultrasound artefacts and how they can be recognized and reduced. Methods The theoretical reasons for artefacts are addressed and the impact of surgery is discussed. Different setups for ultrasound acquisition and different acoustic coupling fluids to fill up the resection cavity are evaluated with respect to improved image quality. Results The enhancement artefact caused by differences in attenuation of the resection cavity fluid and the surrounding brain is the most dominating surgically induced ultrasound artefact. The influence of the artefact may be reduced by inserting ultrasound probes with small footprint into the resection cavity for a close-up view of the areas with suspected tumor remnants. A novel acoustic coupling fluid developed for use during ultrasound imaging in brain tumor surgery has the potential to reduce surgically induced ultrasound artefacts to a minimum. Conclusions Surgeons should be aware of artefacts in ultrasound images that may occur during brain tumor surgery. Techniques to identify and reduce image artefacts are useful and should be known to users of ultrasound in brain tumor surgery.
- Open Access
- 23 May 2012
- Published by Springer Nature in BMC Medical Imaging
- Vol. 12 (1) , 11
Comparison of contrast in brightness mode and strain ultrasonography of glial brain tumours
Image contrast between normal tissue and brain tumours may sometimes appear to be low in intraoperative ultrasound. Ultrasound imaging of strain is an image modality that has been recently explored for intraoperative imaging of the brain. This study aims to investigate differences in image contrast between ultrasound brightness mode (B-mode) images and ultrasound strain magnitude images of brain tumours.
- 23 May 2012
- Published by Springer Nature in BMC Medical Imaging
- Vol. 12 (1) , 11
Open AccessComparison of contrast in brightness mode and strain ultrasonography of glial brain tumours
Image contrast between normal tissue and brain tumours may sometimes appear to be low in intraoperative ultrasound. Ultrasound imaging of strain is an image modality that has been recently explored for intraoperative imaging of the brain. This study aims to investigate differences in image contrast between ultrasound brightness mode (B-mode) images and ultrasound strain magnitude images of brain tumours.
- 1 January 2010
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 36 (1) , 2-10
Tissue Motion and Strain in the Human Brain Assessed by Intraoperative Ultrasound in Glioma Patients
- 1 January 2010
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 36 (1) , 2-10
Tissue Motion and Strain in the Human Brain Assessed by Intraoperative Ultrasound in Glioma Patients
- 1 January 2005
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 31 (1) , 45-51
Strain processing of intraoperative ultrasound images of brain tumours: Initial results
- 1 January 2005
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 31 (1) , 45-51
Strain processing of intraoperative ultrasound images of brain tumours: Initial results