Geirmund Unsgård
Research Subjects
Geirmund Unsgård has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
- Ole Solheim
Norwegian University of Science and Technology Department of Neuromedicine and Movement Science, Faculty of Medicine and Health Sciences Trondheim
7 shared publications - Asgeir Store Jakola
Department of Clinical Neuroscience, Institute of Neuroscience and Physiology, Sahlgrenska Academy, University of Gothenburg , Gothenburg
4 shared publications Frank Lindseth
Department of Neuromedicine and Movement Science, Norwegian University of Science and Technology; and
3 shared publicationsTormod Selbekk
Norwegian National Advisory Unit for Ultrasound and Image guided therapy, Trondheim, Norway
3 shared publications- Tormod Selbekk
National Competence Centre for Ultrasound and Image-Guided Therapy, St. Olavs University Hospital, Trondheim; Department of Medical Technology, SINTEF, Trondheim, Norway
3 shared publications - Lisa Millgård Sagberg
Department of Public Health and Nursing, Norwegian University of Science and Technology, Trondheim, Norway
2 shared publications
Latest Publications
- 1 December 2019
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Neurosurgical Focus
- Vol. 47 (6) , E9
3D ultrasound–guided resection of low-grade gliomas: principles and clinical examples
3D ultrasound (US) is a convenient tool for guiding the resection of low-grade gliomas, seemingly without deterioration in patients’ quality of life. This article offers an update of the intraoperative workflow and the general principles behind the 3D US acquisition of high-quality images. The authors also provide case examples illustrating the technique in two small mesial temporal lobe lesions and in one insular glioma. Due to the ease of acquiring new images for navigation, the operations can be guided by updated image volumes throughout the entire course of surgery. The high accuracy offered by 3D US systems, based on nearly real-time images, allows for precise and safe resections. This is especially useful when an operation is performed through very narrow transcortical corridors.
- 1 December 2019
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Neurosurgical Focus
- Vol. 47 (6) , E9
3D ultrasound–guided resection of low-grade gliomas: principles and clinical examples
3D ultrasound (US) is a convenient tool for guiding the resection of low-grade gliomas, seemingly without deterioration in patients’ quality of life. This article offers an update of the intraoperative workflow and the general principles behind the 3D US acquisition of high-quality images. The authors also provide case examples illustrating the technique in two small mesial temporal lobe lesions and in one insular glioma. Due to the ease of acquiring new images for navigation, the operations can be guided by updated image volumes throughout the entire course of surgery. The high accuracy offered by 3D US systems, based on nearly real-time images, allows for precise and safe resections. This is especially useful when an operation is performed through very narrow transcortical corridors.
- Open Access
- 18 May 2019
- Published by Springer Nature in Acta Neurochirurgica
- Vol. 161 (7) , 1475-1486
A new acoustic coupling fluid with ability to reduce ultrasound imaging artefacts in brain tumour surgery—a phase I study
Background A novel acoustic coupling fluid (ACF), with the potential to reduce surgically induced image artefacts during intraoperative ultrasound imaging in brain tumour surgery, has been evaluated with respect to image quality and safety in a clinical phase 1 study. Methods Fifteen patients with glioblastoma (WHO grade IV) were included. All adverse events were registered in a 6-month study period. During acquisition of 3D ultrasound image volumes, three different concentrations of the ACF and Ringer’s solution were filled into the resection cavity. The effect of ACF on the ultrasound images was rated by the operating surgeon, and by five independent neurosurgeons evaluating a pair of blinded images from all patients. Images from all patients were analysed by comparing pixel brightness in a noise-affected region and a reference region. Results The operating surgeon deemed the ACF images to have less noise than images obtained with Ringers’s solution. The blinded evaluations by the independent neurosurgeons were significantly in favour of ACF (p < 0.0001). The analyses of pixel intensities showed that the ACF images had lower amount of noise than images obtained with Ringer’s solution. No radiological sign of inflammation nor circulatory changes was found in the early postoperative MR images. Of the nine complications registered as serious events in the study period, none was deemed to be caused by the ACF. Conclusion The ultrasound (US) images obtained using ACF have significantly less noise than US images obtained with Ringer’s solution. The rate of adverse events was comparable to what has been reported for similar groups of patients.
- 18 May 2019
- Published by Springer Nature in Acta Neurochirurgica
- Vol. 161 (7) , 1475-1486
Open AccessA new acoustic coupling fluid with ability to reduce ultrasound imaging artefacts in brain tumour surgery—a phase I study
Background A novel acoustic coupling fluid (ACF), with the potential to reduce surgically induced image artefacts during intraoperative ultrasound imaging in brain tumour surgery, has been evaluated with respect to image quality and safety in a clinical phase 1 study. Methods Fifteen patients with glioblastoma (WHO grade IV) were included. All adverse events were registered in a 6-month study period. During acquisition of 3D ultrasound image volumes, three different concentrations of the ACF and Ringer’s solution were filled into the resection cavity. The effect of ACF on the ultrasound images was rated by the operating surgeon, and by five independent neurosurgeons evaluating a pair of blinded images from all patients. Images from all patients were analysed by comparing pixel brightness in a noise-affected region and a reference region. Results The operating surgeon deemed the ACF images to have less noise than images obtained with Ringers’s solution. The blinded evaluations by the independent neurosurgeons were significantly in favour of ACF (p < 0.0001). The analyses of pixel intensities showed that the ACF images had lower amount of noise than images obtained with Ringer’s solution. No radiological sign of inflammation nor circulatory changes was found in the early postoperative MR images. Of the nine complications registered as serious events in the study period, none was deemed to be caused by the ACF. Conclusion The ultrasound (US) images obtained using ACF have significantly less noise than US images obtained with Ringer’s solution. The rate of adverse events was comparable to what has been reported for similar groups of patients.
- 4 June 2016
- Published by Springer Nature in Acta Neurochirurgica
- Vol. 158 (9) , 1775-1781
Standardized reporting of adverse events after microvascular decompression of cranial nerves; a population-based single-institution consecutive series
We provide a standardized report of postoperative complications in a consecutive patient series undergoing MVD. Due to the heterogeneous and non-standardized reporting of complications in the literature, it is difficult to know if our 20 % complication rate is low or high. Standardized reporting is a necessity for meaningful and more valid comparisons across studies. The safety of MVD, a fairly standardized neurosurgical procedure, is well suited for comparisons across centers provided that complications are reported in a standardized manner.
- 4 June 2016
- Published by Springer Nature in Acta Neurochirurgica
- Vol. 158 (9) , 1775-1781
Standardized reporting of adverse events after microvascular decompression of cranial nerves; a population-based single-institution consecutive series
We provide a standardized report of postoperative complications in a consecutive patient series undergoing MVD. Due to the heterogeneous and non-standardized reporting of complications in the literature, it is difficult to know if our 20 % complication rate is low or high. Standardized reporting is a necessity for meaningful and more valid comparisons across studies. The safety of MVD, a fairly standardized neurosurgical procedure, is well suited for comparisons across centers provided that complications are reported in a standardized manner.
- Open Access
- 19 March 2016
- Published by Springer Nature in Acta Neurochirurgica
- Vol. 158 (5) , 875-883
Clinical experience with navigated 3D ultrasound angiography (power Doppler) in microsurgical treatment of brain arteriovenous malformations
Introduction We have previously described a method that has the potential to improve surgery of arteriovenous malformations (AVMs). In the present paper, we present our clinical results. Materials and methods Of 78 patients referred for AVMs to our University Hospital from our geographical catchment region from 2005 through 2013, 31 patients were operated on with microsurgical technique. 3D MR angiography (MRA) with neuronavigation was used for planning. Navigated 3D ultrasound angiography (USA) was used to identify and clip feeders in the initial phase of the operation. None of our patients was embolized preoperatively as part of the surgical procedure. The niduses were extirpated based on the 3D USA. After extirpation, controls were done with 3D USA to verify that the AVMs were completely removed. The Spetzler three-tier classification of the patients was: A: 21, B: 6, C: 4. Results Sixty-eight feeders were identified on preoperative MRA and DSA and 67 feeders were identified and clipped by guidance of intraoperative 3D USA. Six feeders identified preoperatively were missed by 3D USA, while five preoperatively unknown feeders were found and clipped. The overall average bleeding was 440 ml. There was a significant reduction in average bleeding in the last 15 operations compared to the first 16 (340 vs. 559 ml, p = 0.019). We had no serious morbidity (GOS 3 or less). New deficits due to surgery were two patients with quadrantanopia (one class B and one class C), the latter (C) also acquired epilepsy. One patient (class A) acquired a hardly noticeable paresis in two fingers. One hundred percent angiographic cure was achieved in all patients, as evaluated by postoperative DSA. Conclusions Navigated intraoperative 3D USA is a useful tool to identify and clip AVM feeders. Microsurgical extirpation assisted by navigated 3D USA is an effective and safe method for removing AVMs.
- 19 March 2016
- Published by Springer Nature in Acta Neurochirurgica
- Vol. 158 (5) , 875-883
Open AccessClinical experience with navigated 3D ultrasound angiography (power Doppler) in microsurgical treatment of brain arteriovenous malformations
Introduction We have previously described a method that has the potential to improve surgery of arteriovenous malformations (AVMs). In the present paper, we present our clinical results. Materials and methods Of 78 patients referred for AVMs to our University Hospital from our geographical catchment region from 2005 through 2013, 31 patients were operated on with microsurgical technique. 3D MR angiography (MRA) with neuronavigation was used for planning. Navigated 3D ultrasound angiography (USA) was used to identify and clip feeders in the initial phase of the operation. None of our patients was embolized preoperatively as part of the surgical procedure. The niduses were extirpated based on the 3D USA. After extirpation, controls were done with 3D USA to verify that the AVMs were completely removed. The Spetzler three-tier classification of the patients was: A: 21, B: 6, C: 4. Results Sixty-eight feeders were identified on preoperative MRA and DSA and 67 feeders were identified and clipped by guidance of intraoperative 3D USA. Six feeders identified preoperatively were missed by 3D USA, while five preoperatively unknown feeders were found and clipped. The overall average bleeding was 440 ml. There was a significant reduction in average bleeding in the last 15 operations compared to the first 16 (340 vs. 559 ml, p = 0.019). We had no serious morbidity (GOS 3 or less). New deficits due to surgery were two patients with quadrantanopia (one class B and one class C), the latter (C) also acquired epilepsy. One patient (class A) acquired a hardly noticeable paresis in two fingers. One hundred percent angiographic cure was achieved in all patients, as evaluated by postoperative DSA. Conclusions Navigated intraoperative 3D USA is a useful tool to identify and clip AVM feeders. Microsurgical extirpation assisted by navigated 3D USA is an effective and safe method for removing AVMs.
- 1 September 2014
- Published by Elsevier in World Neurosurgery
- Vol. 82 (3-4) , 536.e5-536.e9
Three-Dimensional Ultrasound–Guided Placement of Ventricular Catheters
- 1 September 2014
- Published by Elsevier in World Neurosurgery
- Vol. 82 (3-4) , 536.e5-536.e9
Three-Dimensional Ultrasound–Guided Placement of Ventricular Catheters
- Open Access
- 25 March 2014
- Published by Springer Nature in BMC Medical Imaging
- Vol. 14 (1) , 11
Animal study assessing safety of an acoustic coupling fluid that holds the potential to avoid surgically induced artifacts in 3D ultrasound guided operations
Use of ultrasound in brain tumor surgery is common. The difference in attenuation between brain and isotonic saline may cause artifacts that degrade the ultrasound images, potentially affecting resection grades and safety. Our research group has developed an acoustic coupling fluid that attenuates ultrasound energy like the normal brain. We aimed to test in animals if the newly developed acoustic coupling fluid may have harmful effects.
- 25 March 2014
- Published by Springer Nature in BMC Medical Imaging
- Vol. 14 (1) , 11
Open AccessAnimal study assessing safety of an acoustic coupling fluid that holds the potential to avoid surgically induced artifacts in 3D ultrasound guided operations
Use of ultrasound in brain tumor surgery is common. The difference in attenuation between brain and isotonic saline may cause artifacts that degrade the ultrasound images, potentially affecting resection grades and safety. Our research group has developed an acoustic coupling fluid that attenuates ultrasound energy like the normal brain. We aimed to test in animals if the newly developed acoustic coupling fluid may have harmful effects.
- 17 September 2013
- Published by Springer Nature in Acta Neurochirurgica
- Vol. 155 (12) , 2227-2235
Surgical strategy in grade II astrocytoma: a population-based analysis of survival and morbidity with a strategy of early resection as compared to watchful waiting
Background We recently demonstrated a survival benefit of early resection in unselected diffuse low-grade gliomas (LGG). However, heterogeneity within the LGG entity warrants investigation in a homogenous subgroup. Astrocytoma represents the largest subgroup of LGG, and is characterized by diffuse growth and inferior prognosis. We aimed to study the effects of early resection compared to biopsy and watchful waiting in this subgroup. Methods Patient data was retrospectively reviewed in two neurosurgical departments with regional referral practice. In one hospital, initial diagnostic biopsies and watchful waiting was favored, while early resections guided with three-dimensional (3D) ultrasound were advocated in the other hospital. This created a natural experiment with patient management heavy influenced by residential address. In the hospitals’ histopathology databases, all adult patients diagnosed with supratentorial LGG from 1998 through 2009 were screened (n = 169) and underwent blinded histopathological review. Histopathological review concluded with 117 patients with grade II astrocytomas that were included in the present study. The primary end-point was overall survival assessed by a regional comparison. Results Early resections were performed in 51 (82 %) versus 12 (22 %) patients in the respective hospitals (p < 0.001). The two patient populations were otherwise similar. Median survival was 9.7 years (95 % CI 7.5–11.9) if treated in the hospital favoring early resections compared to 5.6 years (95 % CI 3.5–7.6) if treated at the hospital favoring biopsy and watchful waiting (p = 0.047). No difference in surgical-related neurological morbidity was seen (p = 0.843). Conclusions Early 3D ultrasound guided resections improve survival, apparently without increased morbidity, compared to biopsy and watchful waiting in patients with diffuse World Health Organization (WHO) grade II astrocytomas.
- 17 September 2013
- Published by Springer Nature in Acta Neurochirurgica
- Vol. 155 (12) , 2227-2235
Surgical strategy in grade II astrocytoma: a population-based analysis of survival and morbidity with a strategy of early resection as compared to watchful waiting
Background We recently demonstrated a survival benefit of early resection in unselected diffuse low-grade gliomas (LGG). However, heterogeneity within the LGG entity warrants investigation in a homogenous subgroup. Astrocytoma represents the largest subgroup of LGG, and is characterized by diffuse growth and inferior prognosis. We aimed to study the effects of early resection compared to biopsy and watchful waiting in this subgroup. Methods Patient data was retrospectively reviewed in two neurosurgical departments with regional referral practice. In one hospital, initial diagnostic biopsies and watchful waiting was favored, while early resections guided with three-dimensional (3D) ultrasound were advocated in the other hospital. This created a natural experiment with patient management heavy influenced by residential address. In the hospitals’ histopathology databases, all adult patients diagnosed with supratentorial LGG from 1998 through 2009 were screened (n = 169) and underwent blinded histopathological review. Histopathological review concluded with 117 patients with grade II astrocytomas that were included in the present study. The primary end-point was overall survival assessed by a regional comparison. Results Early resections were performed in 51 (82 %) versus 12 (22 %) patients in the respective hospitals (p < 0.001). The two patient populations were otherwise similar. Median survival was 9.7 years (95 % CI 7.5–11.9) if treated in the hospital favoring early resections compared to 5.6 years (95 % CI 3.5–7.6) if treated at the hospital favoring biopsy and watchful waiting (p = 0.047). No difference in surgical-related neurological morbidity was seen (p = 0.843). Conclusions Early 3D ultrasound guided resections improve survival, apparently without increased morbidity, compared to biopsy and watchful waiting in patients with diffuse World Health Organization (WHO) grade II astrocytomas.
- Open Access
- 23 May 2012
- Published by Springer Nature in BMC Medical Imaging
- Vol. 12 (1) , 11
Comparison of contrast in brightness mode and strain ultrasonography of glial brain tumours
Image contrast between normal tissue and brain tumours may sometimes appear to be low in intraoperative ultrasound. Ultrasound imaging of strain is an image modality that has been recently explored for intraoperative imaging of the brain. This study aims to investigate differences in image contrast between ultrasound brightness mode (B-mode) images and ultrasound strain magnitude images of brain tumours.
- 23 May 2012
- Published by Springer Nature in BMC Medical Imaging
- Vol. 12 (1) , 11
Open AccessComparison of contrast in brightness mode and strain ultrasonography of glial brain tumours
Image contrast between normal tissue and brain tumours may sometimes appear to be low in intraoperative ultrasound. Ultrasound imaging of strain is an image modality that has been recently explored for intraoperative imaging of the brain. This study aims to investigate differences in image contrast between ultrasound brightness mode (B-mode) images and ultrasound strain magnitude images of brain tumours.
- 26 August 2010
- Published by Springer Nature
- Vol. 109, 181-186
Intra-operative Imaging with 3D Ultrasound in Neurosurgery
In recent years the quality of ultrasound (US) imaging has improved considerably. The integration of three dimensional (3D) US with neuronavigation technology has created an efficient and inexpensive tool for intra-operative imaging in neurosurgery. Our experience is based on more than 900 operations with the intra-operative 3D ultrasound equipment SonoWand® and some operations with the research equipment Custux X. The technology has been applied to improve surgery of intraparencymal brain tumours, but has also been found to be useful in a vide range of other procedures, such as operations for cavernomas, skull base tumours, medulla lesions, arteriovenous malformations (AVMs) and for endoscopy guidance. Compared to intraoperative magnetic resonance imaging (ioMRI), 3D US technology is advantageous in different ways: It is flexible and can be used in any operation theatre. There is no need for special instruments, and no need for radiologists or technicians. It adds very little extra time to the operation, and the investment-costs are considerably lower than for ioMRI.
- 26 August 2010
- Published by Springer Nature
- Vol. 109, 181-186
Intra-operative Imaging with 3D Ultrasound in Neurosurgery
In recent years the quality of ultrasound (US) imaging has improved considerably. The integration of three dimensional (3D) US with neuronavigation technology has created an efficient and inexpensive tool for intra-operative imaging in neurosurgery. Our experience is based on more than 900 operations with the intra-operative 3D ultrasound equipment SonoWand® and some operations with the research equipment Custux X. The technology has been applied to improve surgery of intraparencymal brain tumours, but has also been found to be useful in a vide range of other procedures, such as operations for cavernomas, skull base tumours, medulla lesions, arteriovenous malformations (AVMs) and for endoscopy guidance. Compared to intraoperative magnetic resonance imaging (ioMRI), 3D US technology is advantageous in different ways: It is flexible and can be used in any operation theatre. There is no need for special instruments, and no need for radiologists or technicians. It adds very little extra time to the operation, and the investment-costs are considerably lower than for ioMRI.