Nicola L. Fazzalari
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Nicola L. Fazzalari has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Andrew P. Kurmis
College of Medicine & Public Health Flinders University Bedford Park South Australia Australia
4 shared publications Christine Barber
Bone and Joint Research Laboratory, Directorate of Surgical Pathology and Hanson Institute, Institute of Medical and Veterinary Science, Adelaide, South Australia, Australia
3 shared publicationsJohn P Slavotinek
2 shared publicationsJohn P. Slavotinek
Flinders Medical Centre
2 shared publications- Egon Perilli
Medical Device Research Institute, College of Science and Engineering Flinders University Adelaide South Australia Australia
1 shared publication - Geetha Mohan
Center for Musculoskeletal Health, University of California at Davis School of Medicine, Sacramento, California, USA
1 shared publication
Latest Publications
- Open Access
- 21 December 2011
- Published by Springer Nature in Arthritis Research & Therapy
- Vol. 13 (6) , R210
Application of in vivo micro-computed tomography in the temporal characterisation of subchondral bone architecture in a rat model of low-dose monosodium iodoacetate-induced osteoarthritis
Introduction: Osteoarthritis (OA) is a complex, multifactorial joint disease affecting both the cartilage and the subchondral bone. Animal models of OA aid in the understanding of the pathogenesis of OA and testing suitable drugs for OA treatment. In this study we characterized the temporal changes in the tibial subchondral bone architecture in a rat model of low-dose monosodium iodoacetate (MIA)-induced OA using in vivo micro-computed tomography (CT). Methods: Male Wistar rats received a single intra-articular injection of low-dose MIA (0.2 mg) in the right knee joint and sterile saline in the left knee joint. The animals were scanned in vivo by micro-CT at two, six, and ten weeks post-injection, analogous to early, intermediate, and advanced stages of OA, to assess architectural changes in the tibial subchondral bone. The articular cartilage changes in the tibiae were assessed macroscopically and histologically at ten weeks post-injection. Results: Interestingly, tibiae of the MIA-injected knees showed significant bone loss at two weeks, followed by increased trabecular thickness and separation at six and ten weeks. The trabecular number was decreased at all time points compared to control tibiae. The tibial subchondral plate thickness of the MIA-injected knee was increased at two and six weeks and the plate porosity was increased at all time points compared to control. At ten weeks, histology revealed loss of proteoglycans, chondrocyte necrosis, chondrocyte clusters, cartilage fibrillation, and delamination in the MIA-injected tibiae, whereas the control tibiae showed no changes. Micro-CT images and histology showed the presence of subchondral bone sclerosis, cysts, and osteophytes. Conclusions: These findings demonstrate that the low-dose MIA rat model closely mimics the pathological features of progressive human OA. The low-dose MIA rat model is therefore suitable to study the effect of therapeutic drugs on cartilage and bone in a non-trauma model of OA. In vivo micro-CT is a non-destructive imaging technique that can track structural changes in the tibial subchondral bone in this animal model, and could also be used to track changes in bone in preclinical drug intervention studies for OA treatments.
- 21 December 2011
- Published by Springer Nature in Arthritis Research & Therapy
- Vol. 13 (6) , R210
Open AccessApplication of in vivo micro-computed tomography in the temporal characterisation of subchondral bone architecture in a rat model of low-dose monosodium iodoacetate-induced osteoarthritis
Introduction: Osteoarthritis (OA) is a complex, multifactorial joint disease affecting both the cartilage and the subchondral bone. Animal models of OA aid in the understanding of the pathogenesis of OA and testing suitable drugs for OA treatment. In this study we characterized the temporal changes in the tibial subchondral bone architecture in a rat model of low-dose monosodium iodoacetate (MIA)-induced OA using in vivo micro-computed tomography (CT). Methods: Male Wistar rats received a single intra-articular injection of low-dose MIA (0.2 mg) in the right knee joint and sterile saline in the left knee joint. The animals were scanned in vivo by micro-CT at two, six, and ten weeks post-injection, analogous to early, intermediate, and advanced stages of OA, to assess architectural changes in the tibial subchondral bone. The articular cartilage changes in the tibiae were assessed macroscopically and histologically at ten weeks post-injection. Results: Interestingly, tibiae of the MIA-injected knees showed significant bone loss at two weeks, followed by increased trabecular thickness and separation at six and ten weeks. The trabecular number was decreased at all time points compared to control tibiae. The tibial subchondral plate thickness of the MIA-injected knee was increased at two and six weeks and the plate porosity was increased at all time points compared to control. At ten weeks, histology revealed loss of proteoglycans, chondrocyte necrosis, chondrocyte clusters, cartilage fibrillation, and delamination in the MIA-injected tibiae, whereas the control tibiae showed no changes. Micro-CT images and histology showed the presence of subchondral bone sclerosis, cysts, and osteophytes. Conclusions: These findings demonstrate that the low-dose MIA rat model closely mimics the pathological features of progressive human OA. The low-dose MIA rat model is therefore suitable to study the effect of therapeutic drugs on cartilage and bone in a non-trauma model of OA. In vivo micro-CT is a non-destructive imaging technique that can track structural changes in the tibial subchondral bone in this animal model, and could also be used to track changes in bone in preclinical drug intervention studies for OA treatments.
- 27 April 2011
- Published by Springer Nature in Osteoporosis International
- Vol. 22 (6) , 2003-2006
Bone fracture and bone fracture repair
Fracture healing is a multistage repair process that involves complex, well-orchestrated steps initiated in response to tissue injury. The early upregulation of IL-6, osteoprotegerin (OPG), VEGF, and BMPs indicates a central role for these factors in the initiation of cartilage and periosteal woven bone formation. In both callus fracture repair and stress fracture repair, the RANKL/OPG ratio is initially reduced, but peaks earlier in stress fracture healing than callus fracture healing. Though the understanding of the biological processes and molecular signals that coordinate fracture repair has advanced, the cause of variability observed in fracture repair is poorly understood.
- 27 April 2011
- Published by Springer Nature in Osteoporosis International
- Vol. 22 (6) , 2003-2006
Bone fracture and bone fracture repair
Fracture healing is a multistage repair process that involves complex, well-orchestrated steps initiated in response to tissue injury. The early upregulation of IL-6, osteoprotegerin (OPG), VEGF, and BMPs indicates a central role for these factors in the initiation of cartilage and periosteal woven bone formation. In both callus fracture repair and stress fracture repair, the RANKL/OPG ratio is initially reduced, but peaks earlier in stress fracture healing than callus fracture healing. Though the understanding of the biological processes and molecular signals that coordinate fracture repair has advanced, the cause of variability observed in fracture repair is poorly understood.
- Open Access
- 24 December 2010
- Published by Springer Nature in European Spine Journal
- Vol. 20 (3) , 434-439
In vitro evaluation of a manganese chloride phantom-based MRI technique for quantitative determination of lumbar intervertebral disc composition and condition
The application of MRI as a non-invasive, quantitative tool for diagnosing lumbar intervertebral disc degeneration is currently an area of active research. The objective of this study was to examine, in vitro, the efficacy of a manganese chloride phantom-based MRI technique for quantitatively assessing lumbar disc composition and degenerative condition. Sixteen human lumbar discs were imaged ex vivo using T2-weighted MRI, and assigned a quantitative grade based on the relative signal intensities of nine phantoms containing serial concentrations of manganese chloride. Discs were then graded macroscopically for degenerative condition, and water and uronic acid (glycosaminoglycan) contents were determined. MRI ranking exhibited significant and strong negative correlation with nucleus pulposus uronic acid content (r = −0.78). MRI grades were significantly higher for degenerate discs. The technique described presents immediate potential for in vitro studies requiring robust, minimally invasive and quantitative determination of lumbar disc composition and condition. Additionally, the technique may have potential as a clinical tool for diagnosing lumbar disc degeneration as it provides a standardised series of reference phantoms facilitating cross-platform consistency, requires short scan times and simple T2-weighted signal intensity measurements.
- 24 December 2010
- Published by Springer Nature in European Spine Journal
- Vol. 20 (3) , 434-439
Open AccessIn vitro evaluation of a manganese chloride phantom-based MRI technique for quantitative determination of lumbar intervertebral disc composition and condition
The application of MRI as a non-invasive, quantitative tool for diagnosing lumbar intervertebral disc degeneration is currently an area of active research. The objective of this study was to examine, in vitro, the efficacy of a manganese chloride phantom-based MRI technique for quantitatively assessing lumbar disc composition and degenerative condition. Sixteen human lumbar discs were imaged ex vivo using T2-weighted MRI, and assigned a quantitative grade based on the relative signal intensities of nine phantoms containing serial concentrations of manganese chloride. Discs were then graded macroscopically for degenerative condition, and water and uronic acid (glycosaminoglycan) contents were determined. MRI ranking exhibited significant and strong negative correlation with nucleus pulposus uronic acid content (r = −0.78). MRI grades were significantly higher for degenerate discs. The technique described presents immediate potential for in vitro studies requiring robust, minimally invasive and quantitative determination of lumbar disc composition and condition. Additionally, the technique may have potential as a clinical tool for diagnosing lumbar disc degeneration as it provides a standardised series of reference phantoms facilitating cross-platform consistency, requires short scan times and simple T2-weighted signal intensity measurements.
- 1 December 2009
- Published by Elsevier in European Journal of Radiography
- Vol. 1 (4) , 173-179
A MnCl2-based phantom for IVD hydration status determination using MRI: Pre-clinical reliability analyses
- 1 December 2009
- Published by Elsevier in European Journal of Radiography
- Vol. 1 (4) , 173-179
A MnCl2-based phantom for IVD hydration status determination using MRI: Pre-clinical reliability analyses
- 25 July 2008
- Vol. 79 (6) , 507-13
Determining disk hydration status with a MnCl2-based MR model.
An extensive body of literature demonstrates a strong correlation between intervertebral disk (IVD) hydration status (HS) and functional spinal integrity. However, to date, in vivo IVD HS assessment has relied largely on subjective and nonrepeatable measures. The aim of this study was to establish the consistency of signal homogeneity of a novel semisolid-state manganese chloride (MnCl2)-based phantom for HS correlation using conventional magnetic resonance (MR) imaging. Sixteen MnCl2 phantoms, of increasing relative molar concentration (range 0.01 to 2.9 mM), underwent axial MR imaging. Phantom signal-to-noise ratio measures were recorded for each concentration on several sequence types. Coefficient of variance data were calculated to determine the degree of MR signal variation at each concentration. Analysis of variance testing suggested no significant difference in coefficient of variance data derived from phantom signal intensities using either T1- (P = .13) or T2-weighted sequence types (P = .96), suggesting a high degree of relative signal homogeneity. The findings of this study suggest that a MnCl2 phantom combined with a nonfield reactive, semirigid, gelatin suspension media can produce a predictable, concentration-related, homogeneous MR signal response. This may be an appropriate base material for a noninvasive model to allow accurate quantification of the hydration status of the in vivo human IVD.
- 25 July 2008
- Vol. 79 (6) , 507-13
Determining disk hydration status with a MnCl2-based MR model.
An extensive body of literature demonstrates a strong correlation between intervertebral disk (IVD) hydration status (HS) and functional spinal integrity. However, to date, in vivo IVD HS assessment has relied largely on subjective and nonrepeatable measures. The aim of this study was to establish the consistency of signal homogeneity of a novel semisolid-state manganese chloride (MnCl2)-based phantom for HS correlation using conventional magnetic resonance (MR) imaging. Sixteen MnCl2 phantoms, of increasing relative molar concentration (range 0.01 to 2.9 mM), underwent axial MR imaging. Phantom signal-to-noise ratio measures were recorded for each concentration on several sequence types. Coefficient of variance data were calculated to determine the degree of MR signal variation at each concentration. Analysis of variance testing suggested no significant difference in coefficient of variance data derived from phantom signal intensities using either T1- (P = .13) or T2-weighted sequence types (P = .96), suggesting a high degree of relative signal homogeneity. The findings of this study suggest that a MnCl2 phantom combined with a nonfield reactive, semirigid, gelatin suspension media can produce a predictable, concentration-related, homogeneous MR signal response. This may be an appropriate base material for a noninvasive model to allow accurate quantification of the hydration status of the in vivo human IVD.
- 23 November 2007
- Vol. 79 (2) , 119-25
A MnCl2-based MR signal intensity linear response phantom.
This study aimed to develop a manganese chloride (MnCl2)-based phantom model that would allow progressive quantitative assessment of tissue hydration based on observed magnetic resonance (MR) imaging signal intensity (SI) linearity characteristics. The study was performed using a progressive signal refinement technique that allowed development of an imaging tool for semiquantitative sequential discrimination of MR signal responses. A series of 82 phantoms comprising a gelatin-set MnCl2 composite were imaged under basic T1- and T2-weighted conditions. MR SI measurements were taken using region-of-interest selection, and MnCl2 concentrations were adjusted to allow development of a pair of 8-tube phantoms. These phantoms permitted progressive incremental assessment of hydration based on fundamental MR SI response. Statistical analysis showed that phantom MR signal response linearity can be achieved using the phantoms described under both T1 and T2 imaging conditions, yielding R2 values of 0.97 and 0.94, respectively. This novel MnCl2-based phantom can be used as a noninvasive reference standard for quantitative classification of in vivo tissue hydration based on routine clinical MR imaging sequences. Progressive correlation testing using a human cartilage sample should be performed to further refine the model for clinical application.
- 23 November 2007
- Vol. 79 (2) , 119-25
A MnCl2-based MR signal intensity linear response phantom.
This study aimed to develop a manganese chloride (MnCl2)-based phantom model that would allow progressive quantitative assessment of tissue hydration based on observed magnetic resonance (MR) imaging signal intensity (SI) linearity characteristics. The study was performed using a progressive signal refinement technique that allowed development of an imaging tool for semiquantitative sequential discrimination of MR signal responses. A series of 82 phantoms comprising a gelatin-set MnCl2 composite were imaged under basic T1- and T2-weighted conditions. MR SI measurements were taken using region-of-interest selection, and MnCl2 concentrations were adjusted to allow development of a pair of 8-tube phantoms. These phantoms permitted progressive incremental assessment of hydration based on fundamental MR SI response. Statistical analysis showed that phantom MR signal response linearity can be achieved using the phantoms described under both T1 and T2 imaging conditions, yielding R2 values of 0.97 and 0.94, respectively. This novel MnCl2-based phantom can be used as a noninvasive reference standard for quantitative classification of in vivo tissue hydration based on routine clinical MR imaging sequences. Progressive correlation testing using a human cartilage sample should be performed to further refine the model for clinical application.