Andrew P. Kurmis
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Andrew P. Kurmis has a total of 56 co-authors. Here are the top co-authors by number of shared publications:
John P. Slavotinek
Flinders Medical Centre
7 shared publications- Karen J. Reynolds
Medical Device Research Institute, College of Science and Engineering Flinders University Adelaide South Australia Australia
5 shared publications Christine Barber
Bone and Joint Research Laboratory, Directorate of Surgical Pathology and Hanson Institute, Institute of Medical and Veterinary Science, Adelaide, South Australia, Australia
4 shared publicationsJohn P Slavotinek
4 shared publications- Nicola L. Fazzalari
Bone and Joint Research Laboratory, Directorate of Surgical Pathology, SA Pathology and Hanson Institute, Frome Road, Adelaide, SA 5000, Australia
4 shared publications Timothy P. Kurmis
Department of Medical Imaging, Flinders Medical Centre, Flinders Drive, Bedford Park 5042, South Australia, Australia
4 shared publications
Latest Publications
- 26 March 2026
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 484 (7) , 1312-1314
CORR Insights®: How Is Lumbar Fusion Associated With Compensatory Hip Motion After THA?
- 26 March 2026
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 484 (7) , 1312-1314
CORR Insights®: How Is Lumbar Fusion Associated With Compensatory Hip Motion After THA?
- Open Access
- 23 June 2025
- Published by Wiley in Anz Journal of Surgery
- Vol. 95 (10) , 2171-2177
Establishing the Frequency of the HLA Class II Pseudotumour ‘at Risk’ Genotype: A Pilot Epidemiologic Analysis
Purpose: Immune‐mediated adverse local tissue reactions (ALTRs) to implanted metallic devices are an increasingly recognised orthopaedic concern. Recent research has identified a critical HLA genotype associated with increased risk of ALTR development around in situ arthroplasty implants. Carriage imparts a > 700% increased relative‐risk of high‐grade peri‐prosthetic lesion development, associated with pain and joint dysfunction and likely contributing to an increased burden of complex revision surgery. Despite being first reported in 2017, the ‘at risk’ genotype has only subsequently been described in selected metal‐on‐metal and revision arthroplasty cohorts and no population‐level prevalence data has been reported. This novel epidemiologic pilot investigation aimed to explore allele‐variant carriage frequencies of the previously‐described ‘at risk’ HLA genotype in an undifferentiated orthopaedic population to inform larger screening investigations. Methods: One hundred consecutive patients were prospectively recruited. Targeted HLA class II genotyping was performed using a medium‐resolution Luminex‐based approach, and secondary screening was performed to identify the presence of four specific alleles previously‐associated with immune‐mediated reactions to implanted metal devices. Results: Our findings, in a non‐differentiated orthopaedic cohort, suggest a carrier rate of the previously‐defined ‘at risk’ allele of 38%, with 29% of those sampled carrying the defined ‘at risk’ genotype. Conclusion: Our results show a higher‐than‐anticipated incidence of the ‘at risk’ gene and genotype. As genotype‐associated ALTRs may contribute to patient dissatisfaction following primary joint replacements, the impact of this result may be greater than had previously been considered. While acknowledging the preliminary nature of these data, they may guide future screening applications of the genotyping analysis and will provide a foundation contribution‐to‐knowledge for future endeavours in diverse populations.
- 23 June 2025
- Published by Wiley in Anz Journal of Surgery
- Vol. 95 (10) , 2171-2177
Open AccessEstablishing the Frequency of the HLA Class II Pseudotumour ‘at Risk’ Genotype: A Pilot Epidemiologic Analysis
Purpose: Immune‐mediated adverse local tissue reactions (ALTRs) to implanted metallic devices are an increasingly recognised orthopaedic concern. Recent research has identified a critical HLA genotype associated with increased risk of ALTR development around in situ arthroplasty implants. Carriage imparts a > 700% increased relative‐risk of high‐grade peri‐prosthetic lesion development, associated with pain and joint dysfunction and likely contributing to an increased burden of complex revision surgery. Despite being first reported in 2017, the ‘at risk’ genotype has only subsequently been described in selected metal‐on‐metal and revision arthroplasty cohorts and no population‐level prevalence data has been reported. This novel epidemiologic pilot investigation aimed to explore allele‐variant carriage frequencies of the previously‐described ‘at risk’ HLA genotype in an undifferentiated orthopaedic population to inform larger screening investigations. Methods: One hundred consecutive patients were prospectively recruited. Targeted HLA class II genotyping was performed using a medium‐resolution Luminex‐based approach, and secondary screening was performed to identify the presence of four specific alleles previously‐associated with immune‐mediated reactions to implanted metal devices. Results: Our findings, in a non‐differentiated orthopaedic cohort, suggest a carrier rate of the previously‐defined ‘at risk’ allele of 38%, with 29% of those sampled carrying the defined ‘at risk’ genotype. Conclusion: Our results show a higher‐than‐anticipated incidence of the ‘at risk’ gene and genotype. As genotype‐associated ALTRs may contribute to patient dissatisfaction following primary joint replacements, the impact of this result may be greater than had previously been considered. While acknowledging the preliminary nature of these data, they may guide future screening applications of the genotyping analysis and will provide a foundation contribution‐to‐knowledge for future endeavours in diverse populations.
- Open Access
- 3 April 2025
- Published by Springer Nature in Arthroplasty
- Vol. 7 (1) , 1-7
Editorial: Advances in artificial intelligence and robotics in joint arthroplasty
The recently-completed special edition of Arthroplasty entitled 'Advances in Artificial Intelligence and Robotics in Joint Arthroplasty', brings together novel and innovative research from around the world in this cutting edge topic area. With robotics, artificial intelligence and technology-assistance (inside and out of the operating theatre) all becoming increasingly relevant to contemporary practice, we hope the readership will find this special edition an informative and thought-provoking read. Ultimately twelve individual papers were accepted for the edition, covering a range of exciting and novel applications. There clearly exists an ongoing need to provide further validation of new applications and, in many instances, replication of results away from designer sites is needed to provide robust generalizability of use. While several of the included papers show wide international collaboration, the prospect of future interactive work engaging leaders and think-tanks regionally and globally provides a tantalizing opportunity. With global health settings under increasing pressure and scrutiny to provide greater provision of joint replacement services – with the expectation of even more predictable (better) outcomes in a cost and resource efficacious manner – necessity will continue to drive further work exploring how technology-incorporation into arthroplasty care pathways might help address many of these considerations. There are undoubtedly exciting times ahead.
- 3 April 2025
- Published by Springer Nature in Arthroplasty
- Vol. 7 (1) , 1-7
Open AccessEditorial: Advances in artificial intelligence and robotics in joint arthroplasty
The recently-completed special edition of Arthroplasty entitled 'Advances in Artificial Intelligence and Robotics in Joint Arthroplasty', brings together novel and innovative research from around the world in this cutting edge topic area. With robotics, artificial intelligence and technology-assistance (inside and out of the operating theatre) all becoming increasingly relevant to contemporary practice, we hope the readership will find this special edition an informative and thought-provoking read. Ultimately twelve individual papers were accepted for the edition, covering a range of exciting and novel applications. There clearly exists an ongoing need to provide further validation of new applications and, in many instances, replication of results away from designer sites is needed to provide robust generalizability of use. While several of the included papers show wide international collaboration, the prospect of future interactive work engaging leaders and think-tanks regionally and globally provides a tantalizing opportunity. With global health settings under increasing pressure and scrutiny to provide greater provision of joint replacement services – with the expectation of even more predictable (better) outcomes in a cost and resource efficacious manner – necessity will continue to drive further work exploring how technology-incorporation into arthroplasty care pathways might help address many of these considerations. There are undoubtedly exciting times ahead.
- Open Access
- 25 July 2024
- Published by Wiley in Anz Journal of Surgery
- Vol. 94 (11) , 1925-1934
Understanding immune‐mediated titanium allergy to in situ orthopaedic implants: a narrative review of the current literature
Introduction: Clinical recognition of potential immune‐mediated allergic responses to implanted metal devices is increasing. For orthopaedic implants, while ‘pure’ compounds are used in specific circumstances, the majority of components are alloys – a combination of two or more distinct metals. Titanium is found commonly in many orthopaedic devices and is often championed as a ‘hypoallergenic’ option or inclusion. In the absence of a relevant previously published summary on the topic, this paper explores the current state‐of‐understanding of titanium allergy and proposes a patient management algorithm whereby such immune reactions are clinically‐suggested.Methods: A structured, systematic literature review was performed following PRISMA search principles to provide a contemporary summary‐of‐understanding in this area and to highlight clinical and knowledge deficiencies.Results: Thirty‐five topic‐related articles were identified, the majority reflecting small case series' or proof‐of‐concept studies. The general standard of scientific evidence available was poor. Justification for arthroplasty utilization of titanium as a ‘hypoallergenic’ option is largely extrapolated from non‐orthopaedic domains.Conclusions: Both ionic and conjugated titanium particles released from implant surfaces have the potential to trigger innate immune responses and true allergy. There exists no simple, high‐sensitivity, screening test for titanium allergy. Conventional skin‐patch testing is unreliable due to poor dermal penetration. Given established lymphocyte and macrophage activation pathways for allergy responses, in vitro methods using both cell‐types show diagnostic promise. Surgical biopsy analysis from host‐implant interfaces remains the contemporary ‘gold‐standard’, however this represents an invasive, costly and highly‐specialized approach not readily available in most settings. Further research to establish reliable/accessible diagnostic methods are indicated.
- 25 July 2024
- Published by Wiley in Anz Journal of Surgery
- Vol. 94 (11) , 1925-1934
Open AccessUnderstanding immune‐mediated titanium allergy to in situ orthopaedic implants: a narrative review of the current literature
Introduction: Clinical recognition of potential immune‐mediated allergic responses to implanted metal devices is increasing. For orthopaedic implants, while ‘pure’ compounds are used in specific circumstances, the majority of components are alloys – a combination of two or more distinct metals. Titanium is found commonly in many orthopaedic devices and is often championed as a ‘hypoallergenic’ option or inclusion. In the absence of a relevant previously published summary on the topic, this paper explores the current state‐of‐understanding of titanium allergy and proposes a patient management algorithm whereby such immune reactions are clinically‐suggested.Methods: A structured, systematic literature review was performed following PRISMA search principles to provide a contemporary summary‐of‐understanding in this area and to highlight clinical and knowledge deficiencies.Results: Thirty‐five topic‐related articles were identified, the majority reflecting small case series' or proof‐of‐concept studies. The general standard of scientific evidence available was poor. Justification for arthroplasty utilization of titanium as a ‘hypoallergenic’ option is largely extrapolated from non‐orthopaedic domains.Conclusions: Both ionic and conjugated titanium particles released from implant surfaces have the potential to trigger innate immune responses and true allergy. There exists no simple, high‐sensitivity, screening test for titanium allergy. Conventional skin‐patch testing is unreliable due to poor dermal penetration. Given established lymphocyte and macrophage activation pathways for allergy responses, in vitro methods using both cell‐types show diagnostic promise. Surgical biopsy analysis from host‐implant interfaces remains the contemporary ‘gold‐standard’, however this represents an invasive, costly and highly‐specialized approach not readily available in most settings. Further research to establish reliable/accessible diagnostic methods are indicated.
- Open Access
- 20 July 2024
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 19 (1) , 1-5
Gender differences in unintended anterior pelvic roll during primary THA in the lateral position
Background: Fundamental morphologic differences between male and female pelvises are historically recognised. Despite this, little consideration has been given as to whether or not conventional positioning supports used for primary total hip arthroplasties (THAs) performed in the lateral position do an equally effective job of maintaining the intended set up position when comparing genders. Given that recent research has highlighted that unintended pelvic roll occurs commonly during hip surgery, and that such movement may have a mechanically-deleterious consequence upon final construct performance and complication rates, this study was undertaken to explore the differences in pelvic roll between genders. Methods: The output of a high-precision, commercially-available, imageless intra-operative navigation system was prospectively-collected for 85 consecutive patients undergoing unilateral, primary THAs. These data were separated by gender and were utilised to determine differences in pelvic movement around a central sagittal axis. Results: Demographic data were similar between genders, with no between-group differences in mean BMI (p = 0.09) or indication for surgery (p = 0.66), however participating males (mean 68.04) were slightly younger than females (mean 73.31). The mean anterior pelvic roll for females was 9.50°, and for males 8.68°. There were no statistically significant independent correlations observed between gender (p = 0.21) and pelvic roll. Conclusion: The findings of this novel study do not suggest gender differences in the magnitude of unintended, intra-operative, anterior roll, even when corrected for BMI and surgical indication. Average roll of ~ 9° was demonstrated across both groups. An awareness of such positional change during THA surgery may reduce potentially-avoidable post-operative complications.
- 20 July 2024
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 19 (1) , 1-5
Open AccessGender differences in unintended anterior pelvic roll during primary THA in the lateral position
Background: Fundamental morphologic differences between male and female pelvises are historically recognised. Despite this, little consideration has been given as to whether or not conventional positioning supports used for primary total hip arthroplasties (THAs) performed in the lateral position do an equally effective job of maintaining the intended set up position when comparing genders. Given that recent research has highlighted that unintended pelvic roll occurs commonly during hip surgery, and that such movement may have a mechanically-deleterious consequence upon final construct performance and complication rates, this study was undertaken to explore the differences in pelvic roll between genders. Methods: The output of a high-precision, commercially-available, imageless intra-operative navigation system was prospectively-collected for 85 consecutive patients undergoing unilateral, primary THAs. These data were separated by gender and were utilised to determine differences in pelvic movement around a central sagittal axis. Results: Demographic data were similar between genders, with no between-group differences in mean BMI (p = 0.09) or indication for surgery (p = 0.66), however participating males (mean 68.04) were slightly younger than females (mean 73.31). The mean anterior pelvic roll for females was 9.50°, and for males 8.68°. There were no statistically significant independent correlations observed between gender (p = 0.21) and pelvic roll. Conclusion: The findings of this novel study do not suggest gender differences in the magnitude of unintended, intra-operative, anterior roll, even when corrected for BMI and surgical indication. Average roll of ~ 9° was demonstrated across both groups. An awareness of such positional change during THA surgery may reduce potentially-avoidable post-operative complications.
- Open Access
- 2 February 2024
- Published by Springer Nature in Arthroplasty
- Vol. 6 (1) , 1-11
Understanding immune-mediated cobalt/chromium allergy to orthopaedic implants: a meta-synthetic review
Background: The frequency of primary joint replacement surgery continues to increase worldwide. While largely considered biologically inert entities, an increasing body of evidence continues to validate a not insignificant incidence of allergic reactions to such implants. Little previous work has explored genuinely immune-mediated reactivity in this context. In the absence of a contemporary published summary on the topic, this paper explored the current state of understanding of cobalt/chromium allergy and proposes a patient management algorithm whereby such immune reactions are clinically suggested. Methods: A structured, systematic literature review was performed by following PRISMA search principles to provide an updated review of this area. Results: Thirty-six topic-related articles were identified, the majority reflecting lower tiers of scientific evidence with a lack of homogeneous quantitative data to facilitate valid cohort comparisons. Largely, the available literature represented small case series’ or expert opinions. Conclusions: Despite increasing clinical awareness and acknowledgement of true allergy to joint replacement components, this review highlighted that the evidence base underpinning the diagnosis and management of such patients is limited. Both patient-reported metal allergy or skin patch testing are grossly unreliable methods and show almost no correlation with true immune reactivity. Recent studies suggested a potential role for patient-specific in vitro cellular activation testing and/or targeted genetic testing when cobalt/chromium allergy is clinically suspected. However, while likely representing the contemporary “best available” approaches both can be costly undertakings, are not yet universally available, and still require broader validation in non-research settings before wider uptake can be championed.
- 2 February 2024
- Published by Springer Nature in Arthroplasty
- Vol. 6 (1) , 1-11
Open AccessUnderstanding immune-mediated cobalt/chromium allergy to orthopaedic implants: a meta-synthetic review
Background: The frequency of primary joint replacement surgery continues to increase worldwide. While largely considered biologically inert entities, an increasing body of evidence continues to validate a not insignificant incidence of allergic reactions to such implants. Little previous work has explored genuinely immune-mediated reactivity in this context. In the absence of a contemporary published summary on the topic, this paper explored the current state of understanding of cobalt/chromium allergy and proposes a patient management algorithm whereby such immune reactions are clinically suggested. Methods: A structured, systematic literature review was performed by following PRISMA search principles to provide an updated review of this area. Results: Thirty-six topic-related articles were identified, the majority reflecting lower tiers of scientific evidence with a lack of homogeneous quantitative data to facilitate valid cohort comparisons. Largely, the available literature represented small case series’ or expert opinions. Conclusions: Despite increasing clinical awareness and acknowledgement of true allergy to joint replacement components, this review highlighted that the evidence base underpinning the diagnosis and management of such patients is limited. Both patient-reported metal allergy or skin patch testing are grossly unreliable methods and show almost no correlation with true immune reactivity. Recent studies suggested a potential role for patient-specific in vitro cellular activation testing and/or targeted genetic testing when cobalt/chromium allergy is clinically suspected. However, while likely representing the contemporary “best available” approaches both can be costly undertakings, are not yet universally available, and still require broader validation in non-research settings before wider uptake can be championed.
- Open Access
- 14 November 2023
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 18 (1) , 1-7
Quantifying anterior pelvic roll during total hip arthroplasty in the lateral decubitus position
Background: Unintended pelvic positional change is an acknowledged intra-operative problem for hip arthroplasty, seen commonly with procedures performed in the lateral position. If unrecognised, such changes can dramatically alter final acetabular component anteversion potentially resulting in suboptimal construct performance. It has previously been suggested that pelvic roll of just 13° may be enough to place an otherwise perfectly orientated cup outside of conventional ± 10° safe zones. Using the real-time tracking capacity of a commercially available optical navigation system, we aimed to accurately quantify pelvic roll occurring during total hip arthroplasties (THAs) performed in the decubitus position. Methods: Prospectively collected data for 107 consecutive, unilateral, THAs were interrogated to determine the magnitude of pelvic movement around a central longitudinal axis (i.e. AP roll). Correlation statistics with patient age and body mass index (BMI) were also calculated. Results: A mean pelvic roll of 9.5° was observed, being anterior in 96% of cases. Of these, 18.3% of hips had a magnitude of roll greater than 13°. There were no statistically significant independent correlations observed between age (p = 0.87) or BMI (p = 0.59) and mean roll. Conclusions: Errors in achieving acetabular target version may result in numerous post-operative concerns including instability/dislocation, bearing wear, squeaking, range-of-movement limitation and increased revision rate. In a general cohort, our findings suggest a mean anterior pelvic roll during THA of nearly 10°. Without purposeful correction, this may cause substantial deviation from intended target positions. Future work is indicated to map changing pelvic roll during THA which is likely to follow a nonlinear trajectory. Level of evidence: IV. .
- 14 November 2023
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 18 (1) , 1-7
Open AccessQuantifying anterior pelvic roll during total hip arthroplasty in the lateral decubitus position
Background: Unintended pelvic positional change is an acknowledged intra-operative problem for hip arthroplasty, seen commonly with procedures performed in the lateral position. If unrecognised, such changes can dramatically alter final acetabular component anteversion potentially resulting in suboptimal construct performance. It has previously been suggested that pelvic roll of just 13° may be enough to place an otherwise perfectly orientated cup outside of conventional ± 10° safe zones. Using the real-time tracking capacity of a commercially available optical navigation system, we aimed to accurately quantify pelvic roll occurring during total hip arthroplasties (THAs) performed in the decubitus position. Methods: Prospectively collected data for 107 consecutive, unilateral, THAs were interrogated to determine the magnitude of pelvic movement around a central longitudinal axis (i.e. AP roll). Correlation statistics with patient age and body mass index (BMI) were also calculated. Results: A mean pelvic roll of 9.5° was observed, being anterior in 96% of cases. Of these, 18.3% of hips had a magnitude of roll greater than 13°. There were no statistically significant independent correlations observed between age (p = 0.87) or BMI (p = 0.59) and mean roll. Conclusions: Errors in achieving acetabular target version may result in numerous post-operative concerns including instability/dislocation, bearing wear, squeaking, range-of-movement limitation and increased revision rate. In a general cohort, our findings suggest a mean anterior pelvic roll during THA of nearly 10°. Without purposeful correction, this may cause substantial deviation from intended target positions. Future work is indicated to map changing pelvic roll during THA which is likely to follow a nonlinear trajectory. Level of evidence: IV. .
- Open Access
- 4 July 2023
- Published by Springer Nature in Arthroplasty
- Vol. 5 (1) , 1-9
A role for artificial intelligence applications inside and outside of the operating theatre: a review of contemporary use associated with total knee arthroplasty
Background: Artificial intelligence (AI) has become involved in many aspects of everyday life, from voice-activated virtual assistants built into smartphones to global online search engines. Similarly, many areas of modern medicine have found ways to incorporate such technologies into mainstream practice. Despite the enthusiasm, robust evidence to support the utility of AI in contemporary total knee arthroplasty (TKA) remains limited. The purpose of this review was to provide an up-to-date summary of the use of AI in TKA and to explore its current and future value.Methods: Initially, a structured systematic review of the literature was carried out, following PRISMA search principles, with the aim of summarising the understanding of the field and identifying clinical and knowledge gaps.Results: A limited body of published work exists in this area. Much of the available literature is of poor methodological quality and many published studies could be best described as “demonstration of concepts” rather than “proof of concepts”. There exists almost no independent validation of reported findings away from designer/host sites, and the extrapolation of key results to general orthopaedic sites is limited.Conclusion: While AI has certainly shown value in a small number of specific TKA-associated applications, the majority to date have focused on risk, cost and outcome prediction, rather than surgical care, per se. Extensive future work is needed to demonstrate external validity and reliability in non-designer settings. Well-performed studies are warranted to ensure that the scientific evidence base supporting the use of AI in knee arthroplasty matches the global hype.
- 4 July 2023
- Published by Springer Nature in Arthroplasty
- Vol. 5 (1) , 1-9
Open AccessA role for artificial intelligence applications inside and outside of the operating theatre: a review of contemporary use associated with total knee arthroplasty
Background: Artificial intelligence (AI) has become involved in many aspects of everyday life, from voice-activated virtual assistants built into smartphones to global online search engines. Similarly, many areas of modern medicine have found ways to incorporate such technologies into mainstream practice. Despite the enthusiasm, robust evidence to support the utility of AI in contemporary total knee arthroplasty (TKA) remains limited. The purpose of this review was to provide an up-to-date summary of the use of AI in TKA and to explore its current and future value.Methods: Initially, a structured systematic review of the literature was carried out, following PRISMA search principles, with the aim of summarising the understanding of the field and identifying clinical and knowledge gaps.Results: A limited body of published work exists in this area. Much of the available literature is of poor methodological quality and many published studies could be best described as “demonstration of concepts” rather than “proof of concepts”. There exists almost no independent validation of reported findings away from designer/host sites, and the extrapolation of key results to general orthopaedic sites is limited.Conclusion: While AI has certainly shown value in a small number of specific TKA-associated applications, the majority to date have focused on risk, cost and outcome prediction, rather than surgical care, per se. Extensive future work is needed to demonstrate external validity and reliability in non-designer settings. Well-performed studies are warranted to ensure that the scientific evidence base supporting the use of AI in knee arthroplasty matches the global hype.
- 20 March 2023
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 481 (8) , 1607-1609
CORR Insights®: What is the Safe Distance Between Hip and Knee Implants to Reduce the Risk of Ipsilateral Metachronous Periprosthetic Joint Infection?
- 20 March 2023
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 481 (8) , 1607-1609
CORR Insights®: What is the Safe Distance Between Hip and Knee Implants to Reduce the Risk of Ipsilateral Metachronous Periprosthetic Joint Infection?
- Open Access
- 8 March 2023
- Published by IntechOpen
Advanced, Imageless Navigation in Contemporary THA: Optimising Acetabular Component Placement
- 8 March 2023
- Published by IntechOpen
Open AccessAdvanced, Imageless Navigation in Contemporary THA: Optimising Acetabular Component Placement