Michael Rieger
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Michael Rieger has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
Benedikt Czermak
From the Departments of Radiology (M.R., B.C., W.J., M.F.), Trauma Surgery (R.E.A.), and Anesthesiology and Critical Care Medicine (G.S.), Innsbruck Medical University, Innsbruck, Austria
2 shared publications- Marius C. Wick
Department of Radiology, Innsbruck Medical University, Innsbruck, Austria
2 shared publications - Werner Jaschke
Department of Radiology, Medical University Innsbruck, Anichstrasse 35, 6020 Innsbruck, Austria
2 shared publications - Ammar Mallouhi
Department of Radiology, Innsbruck University Hospital, Innsbruck, Austria
1 shared publication Günther Sumann
From the Departments of Radiology (M.R., B.C., W.J., M.F.), Trauma Surgery (R.E.A.), and Anesthesiology and Critical Care Medicine (G.S.), Innsbruck Medical University, Innsbruck, Austria
1 shared publication- Martin C. Freund
Department of Radiology, Leopold-Franzens University, Anichstrasse 35, Innsbruck A-6020, Austria
1 shared publication
Latest Publications
- 1 March 2009
- Published by Wolters Kluwer Health in Journal of Trauma: Injury, Infection & Critical Care
- Vol. 66 (3) , 648-657
Initial Clinical Experience With a 64-MDCT Whole-Body Scanner in an Emergency Department: Better Time Management and Diagnostic Quality?
Background: The objective of this study was to assess time management and diagnostic quality when using a 64-multidetector-row computed tomography (MDCT) whole-body scanner to evaluate polytraumatized patients in an emergency department. Methods: Eighty-eight consecutive polytraumatized patients with injury severity score (ISS) ≥ 18 (mean ISS = 29) were included in this study. Documented and evaluated data were crash history, trauma mechanism, number and pattern of injuries, injury severity, diagnostics, time flow, and missed diagnoses. Data were stored in our hospital information system. Seven time intervals were evaluated. In particular, attention was paid to the “acquisition interval,” the “reformatting and evaluation time” as well as the “CT time” (time from CT start to preliminary diagnosis). A standardized whole-body CT was performed. The acquired CT data together with automatically generated multiplanar reformatted images (“direct MPR”) were transferred to a 3D rendering workstation. Diagnostic quality was determined on the basis of missed diagnoses. Head-to-toe scout images were possible because volume coverage was up to 2 m. Experienced radiologists at an affiliated workstation performed radiologic evaluation of the acquired datasets immediately after acquisition. Results: The “acquisition interval” was 12 minutes ± 4.9 minutes, the “reformatting and evaluation interval” 7.0 minutes ± 2.1 minutes, and the “CT time” 19 minutes ± 6.1 minutes. Altogether, 7 of 486 lesions were recognized but not communicated in the “reformatting and evaluation interval”, and 10 injuries were initially missed and detected during follow-up. Conclusion: This study indicates that 64-MDCT saves time, especially in the “reformatting and evaluation interval.” Diagnostic quality is high, as reflected by the small number of missed diagnoses.
- 1 March 2009
- Published by Wolters Kluwer Health in Journal of Trauma: Injury, Infection & Critical Care
- Vol. 66 (3) , 648-657
Initial Clinical Experience With a 64-MDCT Whole-Body Scanner in an Emergency Department: Better Time Management and Diagnostic Quality?
Background: The objective of this study was to assess time management and diagnostic quality when using a 64-multidetector-row computed tomography (MDCT) whole-body scanner to evaluate polytraumatized patients in an emergency department. Methods: Eighty-eight consecutive polytraumatized patients with injury severity score (ISS) ≥ 18 (mean ISS = 29) were included in this study. Documented and evaluated data were crash history, trauma mechanism, number and pattern of injuries, injury severity, diagnostics, time flow, and missed diagnoses. Data were stored in our hospital information system. Seven time intervals were evaluated. In particular, attention was paid to the “acquisition interval,” the “reformatting and evaluation time” as well as the “CT time” (time from CT start to preliminary diagnosis). A standardized whole-body CT was performed. The acquired CT data together with automatically generated multiplanar reformatted images (“direct MPR”) were transferred to a 3D rendering workstation. Diagnostic quality was determined on the basis of missed diagnoses. Head-to-toe scout images were possible because volume coverage was up to 2 m. Experienced radiologists at an affiliated workstation performed radiologic evaluation of the acquired datasets immediately after acquisition. Results: The “acquisition interval” was 12 minutes ± 4.9 minutes, the “reformatting and evaluation interval” 7.0 minutes ± 2.1 minutes, and the “CT time” 19 minutes ± 6.1 minutes. Altogether, 7 of 486 lesions were recognized but not communicated in the “reformatting and evaluation interval”, and 10 injuries were initially missed and detected during follow-up. Conclusion: This study indicates that 64-MDCT saves time, especially in the “reformatting and evaluation interval.” Diagnostic quality is high, as reflected by the small number of missed diagnoses.
- 12 June 2008
- Published by Massachusetts Medical Society in New England Journal of Medicine
- Vol. 358 (24) , 2618
Rupture of a Calcified Achilles' Tendon
Images in Clinical Medicine from The New England Journal of Medicine — Rupture of a Calcified Achilles' Tendon
- 12 June 2008
- Published by Massachusetts Medical Society in New England Journal of Medicine
- Vol. 358 (24) , 2618
Rupture of a Calcified Achilles' Tendon
Images in Clinical Medicine from The New England Journal of Medicine — Rupture of a Calcified Achilles' Tendon
- Open Access
- 14 August 2007
- Published by Springer Nature in European Spine Journal
- Vol. 16 (3) , 278-282
Initially overseen vertebral body luxation: diagnosed by dynamic fluoroscopy due to delayed dysphagia
This study relates to the case report of a neurologically intact 13-year-old boy with unrecognized traumatic bipedicular vertebral fracture. He was diagnosed complete vertebral body luxation 1 day later by dynamic fluoroscopy, then successfully treated with surgery that resulted in total recovery. The delayed diagnosis highlights the importance of detailed initial clinical and radiology examinations, even when overt symptoms as diagnostic indicators of severe neurological sequelae expected in similar traumatic vertebral fractures are lacking. A 13-year-old boy, who met with a minor bicycle accident, was presented with two small forehead lacerations but without pain or clinical neurological symptoms for radiological examination, which showed no abnormalities. The following day, however, the patient complained about dysphagia and underwent dynamic fluoroscopy for the assessment of deglutition that revealed a total block of contrast medium. Computer tomography (CT) of the cervicothoracic junction showed a bipedicular thoracic vertebral fracture and a hooked vertebral body luxation causing mechanical dysphagia but, surprisingly, without compression of the spinal cord. The patient fully recovered after carefully carried out protracted distension and orthopaedic surgery with vertebral fusion.. One year after surgery, the patient had clinically resumed normal function, and CT showed a sufficient vertebral bony consolidation with anatomical alignment. This case exemplifies the importance of careful initial clinical examination and spinal CT after accidents encompassing an increased risk of spinal fractures, even if neurologically unapparent.
- 14 August 2007
- Published by Springer Nature in European Spine Journal
- Vol. 16 (3) , 278-282
Open AccessInitially overseen vertebral body luxation: diagnosed by dynamic fluoroscopy due to delayed dysphagia
This study relates to the case report of a neurologically intact 13-year-old boy with unrecognized traumatic bipedicular vertebral fracture. He was diagnosed complete vertebral body luxation 1 day later by dynamic fluoroscopy, then successfully treated with surgery that resulted in total recovery. The delayed diagnosis highlights the importance of detailed initial clinical and radiology examinations, even when overt symptoms as diagnostic indicators of severe neurological sequelae expected in similar traumatic vertebral fractures are lacking. A 13-year-old boy, who met with a minor bicycle accident, was presented with two small forehead lacerations but without pain or clinical neurological symptoms for radiological examination, which showed no abnormalities. The following day, however, the patient complained about dysphagia and underwent dynamic fluoroscopy for the assessment of deglutition that revealed a total block of contrast medium. Computer tomography (CT) of the cervicothoracic junction showed a bipedicular thoracic vertebral fracture and a hooked vertebral body luxation causing mechanical dysphagia but, surprisingly, without compression of the spinal cord. The patient fully recovered after carefully carried out protracted distension and orthopaedic surgery with vertebral fusion.. One year after surgery, the patient had clinically resumed normal function, and CT showed a sufficient vertebral bony consolidation with anatomical alignment. This case exemplifies the importance of careful initial clinical examination and spinal CT after accidents encompassing an increased risk of spinal fractures, even if neurologically unapparent.
- 1 January 2003
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 180 (1) , 233-239
Volume-Rendered Multidetector CT Angiography: Noninvasive Follow-Up of Patients Treated with Renal Artery Stents
OBJECTIVE. The purpose of our study was to evaluate the role of multidetector CT (MDCT) angiography with volume rendering for estimating the patency of renal artery stents. SUBJECTS AND METHODS. In 16 patients, 16 renal artery stents were evaluated with MDCT renal angiography and digital subtraction angiography (DSA). CT data were evaluated using multiplanar volume reformations and the volume-rendering algorithm with three different volume-rendered parameter settings (low-to-high, high-to-low, and high—low—high opacity transfer functions: VRLH, VRHL, and VRVE, respectively). Targeted images of each stent were rendered in paraaxial and paracoronal planes and were interactively interpreted. The overall restenosis severity was measured on postprocessed paraaxial and paracoronal images and compared with that obtained on DSA using linear regression analysis. Image quality and lumen delineation on rendered images were also compared using Wilcoxon's signed rank test. RESULTS. Eight restenoses were identified on DSA. Correlations between restenosis severity measured with DSA and those measured with MDCT were significant (p < 0.001). Volume rendering with VRHL allowed the best correlation with DSA (reviewer 1, r2 = 0.86; reviewer 2, r2 = 0.94) and was significantly better than multiplanar volume reformations (p = 0.028). Overall image quality was high with all rendering techniques and with no significant differences (p > 0.59, for all comparisons). Stent lumen was well delineated with volume-rendering modalities; however, VRHL was significantly better than VRLH (p = 0.033). CONCLUSION. Volume-rendered MDCT angiography enabled high-quality three-dimensional reproducible evaluation of the patency of implanted renal artery stents. Volume rendering with VRHL achieved the best performance.
- 1 January 2003
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 180 (1) , 233-239
Volume-Rendered Multidetector CT Angiography: Noninvasive Follow-Up of Patients Treated with Renal Artery Stents
OBJECTIVE. The purpose of our study was to evaluate the role of multidetector CT (MDCT) angiography with volume rendering for estimating the patency of renal artery stents. SUBJECTS AND METHODS. In 16 patients, 16 renal artery stents were evaluated with MDCT renal angiography and digital subtraction angiography (DSA). CT data were evaluated using multiplanar volume reformations and the volume-rendering algorithm with three different volume-rendered parameter settings (low-to-high, high-to-low, and high—low—high opacity transfer functions: VRLH, VRHL, and VRVE, respectively). Targeted images of each stent were rendered in paraaxial and paracoronal planes and were interactively interpreted. The overall restenosis severity was measured on postprocessed paraaxial and paracoronal images and compared with that obtained on DSA using linear regression analysis. Image quality and lumen delineation on rendered images were also compared using Wilcoxon's signed rank test. RESULTS. Eight restenoses were identified on DSA. Correlations between restenosis severity measured with DSA and those measured with MDCT were significant (p < 0.001). Volume rendering with VRHL allowed the best correlation with DSA (reviewer 1, r2 = 0.86; reviewer 2, r2 = 0.94) and was significantly better than multiplanar volume reformations (p = 0.028). Overall image quality was high with all rendering techniques and with no significant differences (p > 0.59, for all comparisons). Stent lumen was well delineated with volume-rendering modalities; however, VRHL was significantly better than VRLH (p = 0.033). CONCLUSION. Volume-rendered MDCT angiography enabled high-quality three-dimensional reproducible evaluation of the patency of implanted renal artery stents. Volume rendering with VRHL achieved the best performance.