Neil David Broom
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Neil David Broom has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
Peter A. Robertson
Department of Orthopaedic Surgery, Auckland City Hospital, 2 Park Road, 1023 Auckland, New Zealand
13 shared publications- Ashvin Thambyah
Experimental Tissue Mechanics Laboratory, Department of Chemical and Materials Engineering, University of Auckland, Auckland, New Zealand
12 shared publications - Kelly R. Wade
Experimental Tissue Mechanics Laboratory, Department of Chemical and Materials Engineering, University of Auckland, Auckland, New Zealand
6 shared publications - Meredith L. Schollum
Tissue Mechanics Laboratory, Department of Chemical and Materials Engineering, University of Auckland, Auckland, New Zealand.
4 shared publications Elwyn C. Firth
Department of Sport and Exercise Science Faculty of Science University of Auckland Auckland New Zealand
3 shared publicationsSamantha A. Rodrigues
Experimental Tissue Mechanics Laboratory, Department of Chemical and Materials Engineering, The University of Auckland, Auckland, New Zealand
3 shared publications
Latest Publications
- Open Access
- 3 May 2025
- Published by Springer Nature in European Spine Journal
- Vol. 34 (6) , 2117-2126
Endplate fractures with subtle structural damage in impact loaded flexed ovine lumbar segments: a potential initiator of disc degeneration
Purpose: To (a) investigate patterns of structural damage in flexed, healthy ovine lumbar motion segments subjected to controlled impact loading approximating a low energy traumatic fall; and (b) determine the relative risk of herniation, endplate failure and other subtle modes of structural disruption as potential mechanical initiators of disc degeneration. Methods: Twenty-three healthy ovine lumbar motion segments were flexed 7° and then impact loaded by dropping a weight of 4.3 kg from a height of 0.8 m. Each sample was macroscopically assessed externally for herniations and then sagittally bisected to assess internal structural damage. Results: Fifteen segments suffered endplate failure, 7 herniated, and 1 suffered both an endplate fracture and herniation. Thirteen segments had a major fracture of the superior endplate and 8 of these also contained subtle damage in the anterior annulus and/or inferior vertebra. Overall, both herniated and endplate fractured samples indicated an oblique mode of failure tending from posterior-superior to anterior-inferior. Other forms of subtle tissue damage were observed across all visible regions of the disc, these coexisting with the major modes of failure. Conclusion: Flexed ovine lumbar motion segments subjected to impact loading approximating a low energy traumatic fall, are more likely to fail via endplate fracture accompanied by more subtle structural damage in the disc and/or adjacent vertebra. Failure by disc herniation was less common. The subtle, co-occurring, multi-component failure modes add to our recognition of the complexity of these injuries, and the potential role they might play in the initiation and development of the degenerative cascade in the intervertebral disc.
- 3 May 2025
- Published by Springer Nature in European Spine Journal
- Vol. 34 (6) , 2117-2126
Open AccessEndplate fractures with subtle structural damage in impact loaded flexed ovine lumbar segments: a potential initiator of disc degeneration
Purpose: To (a) investigate patterns of structural damage in flexed, healthy ovine lumbar motion segments subjected to controlled impact loading approximating a low energy traumatic fall; and (b) determine the relative risk of herniation, endplate failure and other subtle modes of structural disruption as potential mechanical initiators of disc degeneration. Methods: Twenty-three healthy ovine lumbar motion segments were flexed 7° and then impact loaded by dropping a weight of 4.3 kg from a height of 0.8 m. Each sample was macroscopically assessed externally for herniations and then sagittally bisected to assess internal structural damage. Results: Fifteen segments suffered endplate failure, 7 herniated, and 1 suffered both an endplate fracture and herniation. Thirteen segments had a major fracture of the superior endplate and 8 of these also contained subtle damage in the anterior annulus and/or inferior vertebra. Overall, both herniated and endplate fractured samples indicated an oblique mode of failure tending from posterior-superior to anterior-inferior. Other forms of subtle tissue damage were observed across all visible regions of the disc, these coexisting with the major modes of failure. Conclusion: Flexed ovine lumbar motion segments subjected to impact loading approximating a low energy traumatic fall, are more likely to fail via endplate fracture accompanied by more subtle structural damage in the disc and/or adjacent vertebra. Failure by disc herniation was less common. The subtle, co-occurring, multi-component failure modes add to our recognition of the complexity of these injuries, and the potential role they might play in the initiation and development of the degenerative cascade in the intervertebral disc.
- 1 March 2019
- Published by Elsevier in The Spine Journal
- Vol. 19 (3) , 532-544
New evidence for structural integration across the cartilage-vertebral endplate junction and its relation to herniation
- 1 March 2019
- Published by Elsevier in The Spine Journal
- Vol. 19 (3) , 532-544
New evidence for structural integration across the cartilage-vertebral endplate junction and its relation to herniation
- 8 August 2017
- Published by Springer Nature in European Spine Journal
- Vol. 26 (10) , 2629-2641
A more realistic disc herniation model incorporating compression, flexion and facet-constrained shear: a mechanical and microstructural analysis. Part II: high rate or ‘surprise’ loading
Purpose Part I of this study explored mechanisms of disc failure in a complex posture incorporating physiological amounts of flexion and shear at a loading rate considerably lower than likely to occur in a typical in vivo manual handling situation. Given the strain-rate-dependent mechanical properties of the heavily hydrated disc, loading rate will likely influence the mechanisms of disc failure. Part II investigates the mechanisms of failure in healthy discs subjected to surprise-rate compression while held in the same complex posture. Methods 37 motion segments from 13 healthy mature ovine lumbar spines were compressed in a complex posture intended to simulate the situation arising when bending and twisting while lifting a heavy object at a displacement rate of 400 mm/min. Seven of the 37 samples reached the predetermined displacement prior to a reduction in load and were classified as early stage failures, providing insight to initial areas of disc disruption. Both groups of damaged discs were then analysed microstructurally using light microscopy. Results The average failure load under high rate complex loading was 6.96 kN (STD 1.48 kN), significantly lower statistically than for low rate complex loading [8.42 kN (STD 1.22 kN)]. Also, unlike simple flexion or low rate complex loading, direct radial ruptures and non-continuous mid-wall tearing in the posterior and posterolateral regions were commonly accompanied by disruption extending to the lateral and anterior disc. Conclusion This study has again shown that multiple modes of damage are common when compressing a segment in a complex posture, and the load bearing ability, already less than in a neutral or flexed posture, is further compromised with high rate complex loading.
- 8 August 2017
- Published by Springer Nature in European Spine Journal
- Vol. 26 (10) , 2629-2641
A more realistic disc herniation model incorporating compression, flexion and facet-constrained shear: a mechanical and microstructural analysis. Part II: high rate or ‘surprise’ loading
Purpose Part I of this study explored mechanisms of disc failure in a complex posture incorporating physiological amounts of flexion and shear at a loading rate considerably lower than likely to occur in a typical in vivo manual handling situation. Given the strain-rate-dependent mechanical properties of the heavily hydrated disc, loading rate will likely influence the mechanisms of disc failure. Part II investigates the mechanisms of failure in healthy discs subjected to surprise-rate compression while held in the same complex posture. Methods 37 motion segments from 13 healthy mature ovine lumbar spines were compressed in a complex posture intended to simulate the situation arising when bending and twisting while lifting a heavy object at a displacement rate of 400 mm/min. Seven of the 37 samples reached the predetermined displacement prior to a reduction in load and were classified as early stage failures, providing insight to initial areas of disc disruption. Both groups of damaged discs were then analysed microstructurally using light microscopy. Results The average failure load under high rate complex loading was 6.96 kN (STD 1.48 kN), significantly lower statistically than for low rate complex loading [8.42 kN (STD 1.22 kN)]. Also, unlike simple flexion or low rate complex loading, direct radial ruptures and non-continuous mid-wall tearing in the posterior and posterolateral regions were commonly accompanied by disruption extending to the lateral and anterior disc. Conclusion This study has again shown that multiple modes of damage are common when compressing a segment in a complex posture, and the load bearing ability, already less than in a neutral or flexed posture, is further compromised with high rate complex loading.
- 7 August 2017
- Published by Springer Nature in European Spine Journal
- Vol. 26 (10) , 2616-2628
A more realistic disc herniation model incorporating compression, flexion and facet-constrained shear: a mechanical and microstructural analysis. Part I: Low rate loading
Purpose To date, the mechanisms of disc failure have been explored at a microstructural level in relatively simple postures. However, in vivo the disc is known to be subjected to complex loading in compression, bending and shear, and the influence of these factors on the mechanisms of disc failure is yet to be described at a microstructural level. The purpose of this study was to provide a microstructural analysis of the mechanisms of failure in healthy discs subjected to compression while held in a complex posture incorporating physiological amounts of flexion and facet-constrained shear. Methods 30 motion segments from 10 healthy mature ovine lumbar spines were compressed in a complex posture intended to simulate the situation arising when bending and twisting while lifting a heavy object, and at a displacement rate of 40 mm/min. Nine of the 30 samples reached the predetermined displacement prior to a reduction in load and were classified as early-stage failures, providing insight into initial areas of disc disruption. Both groups of damaged discs were then analysed microstructurally using light microscopy. Results Complex postures significantly reduced the load required to cause disc failure than earlier described for flexed postures [8.42 kN (STD 1.22 kN) compared to 9.69 kN (STD 2.56 kN)] and resulted in a very different failure morphology to that observed in either simple flexion or direct compression, involving infiltration of nucleus material in a circuitous path to the annular periphery. Conclusion The complex posture as used in this study significantly reduced the load required to cause disc failure, providing further evidence that asymmetric postures while lifting should be avoided if possible.
- 7 August 2017
- Published by Springer Nature in European Spine Journal
- Vol. 26 (10) , 2616-2628
A more realistic disc herniation model incorporating compression, flexion and facet-constrained shear: a mechanical and microstructural analysis. Part I: Low rate loading
Purpose To date, the mechanisms of disc failure have been explored at a microstructural level in relatively simple postures. However, in vivo the disc is known to be subjected to complex loading in compression, bending and shear, and the influence of these factors on the mechanisms of disc failure is yet to be described at a microstructural level. The purpose of this study was to provide a microstructural analysis of the mechanisms of failure in healthy discs subjected to compression while held in a complex posture incorporating physiological amounts of flexion and facet-constrained shear. Methods 30 motion segments from 10 healthy mature ovine lumbar spines were compressed in a complex posture intended to simulate the situation arising when bending and twisting while lifting a heavy object, and at a displacement rate of 40 mm/min. Nine of the 30 samples reached the predetermined displacement prior to a reduction in load and were classified as early-stage failures, providing insight into initial areas of disc disruption. Both groups of damaged discs were then analysed microstructurally using light microscopy. Results Complex postures significantly reduced the load required to cause disc failure than earlier described for flexed postures [8.42 kN (STD 1.22 kN) compared to 9.69 kN (STD 2.56 kN)] and resulted in a very different failure morphology to that observed in either simple flexion or direct compression, involving infiltration of nucleus material in a circuitous path to the annular periphery. Conclusion The complex posture as used in this study significantly reduced the load required to cause disc failure, providing further evidence that asymmetric postures while lifting should be avoided if possible.
- 18 August 2016
- Published by Wiley in Journal of Anatomy
- Vol. 230 (1) , 152-164
How maturity influences annulus‐endplate integration in the ovine intervertebral disc: a micro‐ and ultra‐structural study
The annulus-endplate anchorage system plays a vital role in structurally linking the compliant disc to its adjacent much more rigid vertebrae. Past literature has identified the endplate as a region of weakness, not just in the mature spine but also in the immature spine. The aim of this structural study was to investigate in detail the morphological changes associated with annulus-endplate integration through different stages of maturity. Ovine lumbar motion segments were collected from two immature age groups: (i) newborn and (ii) spring lamb (roughly 3 months old); these were compared with a third group of previously analysed mature ewe samples (3–5 years). Sections from the posterior region of each motion segment were obtained for microstructural analysis and imaged in their fully hydrated state via differential interference contrast (DIC) optical microscopy. Selected slices were further prepared and imaged via scanning electron microscopy (SEM) to analyse fibril-level modes of integration. Despite significant changes in endplate morphology, the annular fibre bundles in all three age groups displayed a similar branching mechanism, with the main bundle splitting into several sub-bundles on entering the cartilaginous endplate. This morphology, previously described in the mature ovine disc, is thought to strengthen significantly annulus-endplate integration. Its prevalence from an age as young as birth emphasizes the critical role that it plays in the anchorage system. The structure of the branched sub-bundles and their integration with the surrounding matrix were found to vary with age due to changes in the cartilaginous and vertebral components of the endplate. Microscopically, the sub-bundles in both immature age groups appeared to fade into the surrounding tissue due to their fibril-level integration with the cartilaginous endplate tissue, this mechanism being particularly complex in the spring lamb disc. However, in the fully mature disc, the sub-bundles remained as separate entities throughout the full depth of their anchorage into the cartilaginous endplate. Cell morphology was also found to vary with maturity within the cartilaginous matrix and it is proposed that this relates to endplate development and ossification.
- 18 August 2016
- Published by Wiley in Journal of Anatomy
- Vol. 230 (1) , 152-164
How maturity influences annulus‐endplate integration in the ovine intervertebral disc: a micro‐ and ultra‐structural study
The annulus-endplate anchorage system plays a vital role in structurally linking the compliant disc to its adjacent much more rigid vertebrae. Past literature has identified the endplate as a region of weakness, not just in the mature spine but also in the immature spine. The aim of this structural study was to investigate in detail the morphological changes associated with annulus-endplate integration through different stages of maturity. Ovine lumbar motion segments were collected from two immature age groups: (i) newborn and (ii) spring lamb (roughly 3 months old); these were compared with a third group of previously analysed mature ewe samples (3–5 years). Sections from the posterior region of each motion segment were obtained for microstructural analysis and imaged in their fully hydrated state via differential interference contrast (DIC) optical microscopy. Selected slices were further prepared and imaged via scanning electron microscopy (SEM) to analyse fibril-level modes of integration. Despite significant changes in endplate morphology, the annular fibre bundles in all three age groups displayed a similar branching mechanism, with the main bundle splitting into several sub-bundles on entering the cartilaginous endplate. This morphology, previously described in the mature ovine disc, is thought to strengthen significantly annulus-endplate integration. Its prevalence from an age as young as birth emphasizes the critical role that it plays in the anchorage system. The structure of the branched sub-bundles and their integration with the surrounding matrix were found to vary with age due to changes in the cartilaginous and vertebral components of the endplate. Microscopically, the sub-bundles in both immature age groups appeared to fade into the surrounding tissue due to their fibril-level integration with the cartilaginous endplate tissue, this mechanism being particularly complex in the spring lamb disc. However, in the fully mature disc, the sub-bundles remained as separate entities throughout the full depth of their anchorage into the cartilaginous endplate. Cell morphology was also found to vary with maturity within the cartilaginous matrix and it is proposed that this relates to endplate development and ossification.
- 21 July 2015
- Published by Wiley in Journal of Anatomy
- Vol. 227 (3) , 315-324
How a radial focal incision influences the internal shear distribution in articular cartilage with respect to its zonally differentiated microanatomy
Articular surface fibrillation and the loss of both transverse interconnectivity and zonal differentiation are indicators of articular cartilage (AC) degeneration. However, exactly how these structural features affect the load-redistributing properties of cartilage is still poorly understood. This study investigated how a single radial incision made to varying depths with respect to the primary zones of AC influenced its deformation response to compression. Three depths of incision were applied to cartilage-on-bone tissue blocks: one not exceeding the transition zone; one into the mid-radial zone; and one down to the calcified cartilage. Also included were non-incised controls. All samples were compressed to a near-equilibrium strain using a flat-faced indenter that incorporated a central relief channel within which the incision could be positioned lengthwise along the channel axis. Employing fixation under load followed by decalcification, the structural responses of the cartilage-on-bone samples were investigated. The study provides an analysis of the micro-morphological response that is characteristic of a completely normal cartilage-on-bone system but which contains a defined degree of disruption induced by the focal radial incision. The resulting loss of transverse continuity of the cartilage with respect to its zonally differentiated structure is shown to lead to an altered pattern of internal matrix shear whose intensity varies with incision depth.
- 21 July 2015
- Published by Wiley in Journal of Anatomy
- Vol. 227 (3) , 315-324
How a radial focal incision influences the internal shear distribution in articular cartilage with respect to its zonally differentiated microanatomy
Articular surface fibrillation and the loss of both transverse interconnectivity and zonal differentiation are indicators of articular cartilage (AC) degeneration. However, exactly how these structural features affect the load-redistributing properties of cartilage is still poorly understood. This study investigated how a single radial incision made to varying depths with respect to the primary zones of AC influenced its deformation response to compression. Three depths of incision were applied to cartilage-on-bone tissue blocks: one not exceeding the transition zone; one into the mid-radial zone; and one down to the calcified cartilage. Also included were non-incised controls. All samples were compressed to a near-equilibrium strain using a flat-faced indenter that incorporated a central relief channel within which the incision could be positioned lengthwise along the channel axis. Employing fixation under load followed by decalcification, the structural responses of the cartilage-on-bone samples were investigated. The study provides an analysis of the micro-morphological response that is characteristic of a completely normal cartilage-on-bone system but which contains a defined degree of disruption induced by the focal radial incision. The resulting loss of transverse continuity of the cartilage with respect to its zonally differentiated structure is shown to lead to an altered pattern of internal matrix shear whose intensity varies with incision depth.
- 15 June 2015
- Published by Wolters Kluwer Health in Spine
- Vol. 40 (12) , 891-901
“Surprise” Loading in Flexion Increases the Risk of Disc Herniation Due to Annulus-Endplate Junction Failure
Study Design. Microstructural investigation of compression-induced herniation of the flexed lumbar disc. Objective. To provide a microstructural analysis of the mechanisms of annular wall failure in healthy discs subjected to flexion and a rate of compression comparable with the maximum rate at which the muscles of the spinal column can generate a force. Summary of Background Data. Clinical evidence indicates the involvement of the endplate in herniation. It is known that both an elevated rate of compression and a flexed posture are necessary to cause disc failure either within the midspan of the annulus or at the annular-endplate interface. However, the question of what effect a sudden or “surprise” loading might have on the mode of failure is, as yet, unanswered. Methods. Twenty-four healthy mature ovine lumbar motion segments were compressed to failure in high physiological flexion (10º). This occurred over approximately 5 mm of crosshead displacement in 0.75 seconds that resulted in a displacement rate of 400 mm/min (defined as a “surprise” rate) and was intended to simulate the maximum rate at which the muscles of the spinal column can generate a force. The damaged discs were then analyzed microstructurally. Results. Fifty-eight percent of discs suffered annular-endplate junction rupture, 25% suffered midspan annular rupture, and the balance of 17% endplate fracture. Microstructural analysis indicated that annular rupture initiated at the endplate apical ridge in the mid-to-outer region of the annulus in both annular-endplate and midspan annulus rupture. Conclusion. Motion segments subjected to a “surprise” loading rate are likely to fail via some form of annular rupture. Failure under such sudden loading occurs mostly via rupture of the annular-endplate junction and is thought to arise from a rate-induced mechanostructural imbalance between the annulus and the endplate. Level of Evidence: N/A
- 15 June 2015
- Published by Wolters Kluwer Health in Spine
- Vol. 40 (12) , 891-901
“Surprise” Loading in Flexion Increases the Risk of Disc Herniation Due to Annulus-Endplate Junction Failure
Study Design. Microstructural investigation of compression-induced herniation of the flexed lumbar disc. Objective. To provide a microstructural analysis of the mechanisms of annular wall failure in healthy discs subjected to flexion and a rate of compression comparable with the maximum rate at which the muscles of the spinal column can generate a force. Summary of Background Data. Clinical evidence indicates the involvement of the endplate in herniation. It is known that both an elevated rate of compression and a flexed posture are necessary to cause disc failure either within the midspan of the annulus or at the annular-endplate interface. However, the question of what effect a sudden or “surprise” loading might have on the mode of failure is, as yet, unanswered. Methods. Twenty-four healthy mature ovine lumbar motion segments were compressed to failure in high physiological flexion (10º). This occurred over approximately 5 mm of crosshead displacement in 0.75 seconds that resulted in a displacement rate of 400 mm/min (defined as a “surprise” rate) and was intended to simulate the maximum rate at which the muscles of the spinal column can generate a force. The damaged discs were then analyzed microstructurally. Results. Fifty-eight percent of discs suffered annular-endplate junction rupture, 25% suffered midspan annular rupture, and the balance of 17% endplate fracture. Microstructural analysis indicated that annular rupture initiated at the endplate apical ridge in the mid-to-outer region of the annulus in both annular-endplate and midspan annulus rupture. Conclusion. Motion segments subjected to a “surprise” loading rate are likely to fail via some form of annular rupture. Failure under such sudden loading occurs mostly via rupture of the annular-endplate junction and is thought to arise from a rate-induced mechanostructural imbalance between the annulus and the endplate. Level of Evidence: N/A
- 1 March 2015
- Published by Elsevier in The Spine Journal
- Vol. 15 (3) , 405-416
A multiscale structural investigation of the annulus-endplate anchorage system and its mechanisms of failure
- 1 March 2015
- Published by Elsevier in The Spine Journal
- Vol. 15 (3) , 405-416
A multiscale structural investigation of the annulus-endplate anchorage system and its mechanisms of failure
- 1 November 2014
- Published by Elsevier in The Spine Journal
- Vol. 14 (11) , S39-S40
A Multiscale Structural Investigation of the Annulus-Endplate Anchorage System and its Mechanisms of Failure
- 1 November 2014
- Published by Elsevier in The Spine Journal
- Vol. 14 (11) , S39-S40
A Multiscale Structural Investigation of the Annulus-Endplate Anchorage System and its Mechanisms of Failure
- 1 April 2014
- Published by Wiley in Journal of Anatomy
- Vol. 224 (6) , 647-658
Microstructural changes in cartilage and bone related to repetitive overloading in an equine athlete model
The palmar aspect of the third metacarpal (MC3) condyle of equine athletes is known to be subjected to repetitive overloading that can lead to the accumulation of joint tissue damage, degeneration, and stress fractures, some of which result in catastrophic failure. However, there is still a need to understand at a detailed microstructural level how this damage progresses in the context of the wider joint tissue complex, i.e. the articular surface, the hyaline and calcified cartilage, and the subchondral bone.MC3 bones from non‐fractured joints were obtained from the right forelimbs of 16 Thoroughbred racehorses varying in age between 3 and 8 years, with documented histories of active race training. Detailed microstructural analysis of two clinically important sites, the parasagittal grooves and the mid‐condylar regions, identified extensive levels of microdamage in the calcified cartilage and subchondral bone concealed beneath outwardly intact hyaline cartilage. The study shows a progression in microdamage severity, commencing with mild hard‐tissue microcracking in younger animals and escalating to severe subchondral bone collapse and lesion formation in the hyaline cartilage with increasing age and thus athletic activity. The presence of a clearly distinguishable fibrous tissue layer at the articular surface immediately above sites of severe subchondral collapse suggested a limited reparative response in the hyaline cartilage.
- 1 April 2014
- Published by Wiley in Journal of Anatomy
- Vol. 224 (6) , 647-658
Microstructural changes in cartilage and bone related to repetitive overloading in an equine athlete model
The palmar aspect of the third metacarpal (MC3) condyle of equine athletes is known to be subjected to repetitive overloading that can lead to the accumulation of joint tissue damage, degeneration, and stress fractures, some of which result in catastrophic failure. However, there is still a need to understand at a detailed microstructural level how this damage progresses in the context of the wider joint tissue complex, i.e. the articular surface, the hyaline and calcified cartilage, and the subchondral bone.MC3 bones from non‐fractured joints were obtained from the right forelimbs of 16 Thoroughbred racehorses varying in age between 3 and 8 years, with documented histories of active race training. Detailed microstructural analysis of two clinically important sites, the parasagittal grooves and the mid‐condylar regions, identified extensive levels of microdamage in the calcified cartilage and subchondral bone concealed beneath outwardly intact hyaline cartilage. The study shows a progression in microdamage severity, commencing with mild hard‐tissue microcracking in younger animals and escalating to severe subchondral bone collapse and lesion formation in the hyaline cartilage with increasing age and thus athletic activity. The presence of a clearly distinguishable fibrous tissue layer at the articular surface immediately above sites of severe subchondral collapse suggested a limited reparative response in the hyaline cartilage.