ULUrban Lindgren

Urban Lindgren

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Urban Lindgren has a total of 7 co-authors. Here are the top co-authors by number of shared publications:

  • A. C. Wikstrom

    Karolinska University Hospital, Clinical Immunology and Transfusion Medicine F79, Huddinge, SE-14186 Stockholm, Sweden

    1 shared publication
  • B. H. Brismar

    Karolinska University Hospital, Department of Orthopaedics K54, Huddinge, S14186 Stockholm, Sweden

    1 shared publication
  • Harald Brismar

    Department for Clinical Science, Intervention and Technology (CLINTEC), Division of Orthopedics, Karolinska Institutet, Stockholm, Sweden

    1 shared publication
  • Irene Jensen

    Karolinska Institutet

    1 shared publication
  • Jouko Kivioja

    Division of Orthopaedics, Department of Clinical Intervention and Technology (Huddinge), Karolinska Institute, K54, 141 86, Stockholm, Sweden

    1 shared publication
  • Ola Hallert

    Department for Clinical Science, Division of Orthopedics, Karolinska Institutet, Stockholm, Sweden

    1 shared publication

Latest Publications

  • Open Access

    The direct anterior approach: initial experience of a minimally invasive technique for total hip arthroplasty

    by Ola Hallert, Yan Li, Harald Brismar, Urban Lindgren

    Background: Less invasive approaches for hip arthroplasty have been developed in order to decrease traumatisation of soft tissue and shorten hospital stay. However, the benefits with a new technique can be at the expense of a new panorama of problems. This manuscript describes, with emphasis on postoperative complications, our experience from the first 200 cases of unilateral hip replacement using the direct anterior minimally invasive (MIS) approach. Methods: A straight incision in front of the greater trochanter was used and the tensor muscle was approached subfascially and retracted laterally. The joint was opened and the femoral head was removed. Usually excellent acetabular exposure was obtained. In order to get access to the proximal femur, the hip capsule was released posterolaterally so that the femur could be lifted using a special retractor behind the tip of the trochanter. After insertion of the prostheses, the wound was closed using running sutures in the fascia overlying the tensor, sub- and intracutaneously. Results: There was a small influence of BMI on the duration of surgery, and obese patients tended to have the cup positioned at a higher degree of deviation. There were in total 17 complications of which 5 necessitated revision surgery; 3 peroperative femoral fractures and 2 dislocations. Another 4 dislocations were treated with closed reduction and did not recur. 3 cases of nerve injury were noted, all resolved within 12 months. Three cases of DVT were diagnosed as well as 2 cases of postoperative infection; none of these led to chronic disability. Conclusions: The technique is perhaps more technically demanding than the lateral approaches used today due to the somewhat limited surgical exposure. Morbidly obese or very muscular patients as well as patients with a short femoral neck or acetabular protrusion can represent particular problems. Our results indicate that there are certain risks when adopting this procedure but the complications noted are avoidable.


  • Adverse reaction to metal release from a modular metal-on-polyethylene hip prosthesis

    by J. U. Lindgren, B. H. Brismar, A. C. Wikstrom

    A 70-year-old man with an uncemented metal-on-polyethylene total hip prosthesis underwent revision arthroplasty 33 months later because of pain, swelling and recurrent dislocation. There appeared to be corrosion and metal release from the prosthetic head, resulting in pseudotumour formation and severe local soft-tissue destruction. The corrosion occurred at the junction between the titanium-molybdenum-zirconium-iron taper and the cobalt-chrome-molybdenum head, but the mechanism was unproven.


  • Open Access

    Neither the WAD-classification nor the Quebec Task Force follow-up regimen seems to be important for the outcome after a whiplash injury. A prospective study on 186 consecutive patients

    by Jouko Kivioja, Irene Jensen, Urban Lindgren

    A classification of injury and a follow-up schedule were proposed by the Quebec Task Force (QTF) in 1995. No general agreement about the clinical usefulness of the WAD-classification or of the suggested follow-up regimen exists. A series of 186 consecutive cases seen in the emergency room during the acute phase after a whiplash injury was prospectively studied for 1 year. All findings including history and physical findings were recorded using standardized QTF protocols. In one group follow-up visits were done according to the QTF regimen: at 1, 3, 6, 12 weeks and 1 year after the accident; in a control group no visit was scheduled. The outcome variable was neck pain at 1 year after the accident. After 1 year, 18% of the total number of patients had significant neck pain. Risk factors for chronic neck pain at 1 year after whiplash injury were: neck pain before the accident and a high degree of emotional distress at the time of the accident; both factors independently associated with a tenfold increased risk of developing chronic neck pain. Neither the WAD classification nor the QTF follow-up regimen could be linked to a better outcome. In this study the outcome was associated with patient-specific characteristics and not with physical signs of injury, the depth of the initial evaluation or the follow-up regimen.