RGRobert Chapman Gilkeson

Robert Chapman Gilkeson

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Robert Chapman Gilkeson has a total of 183 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Real-world impact of high-pitch helical CT on radiation exposure and image quality in infants being evaluated for cardiothoracic pathologies

    by Joshua G. Hunter, Kaustav Bera, Leslie Ciancibello, Syed Muhammad Awais Bukhari, Jennifer Sposato, Kianoush Ansari Gilani, Robert Gilkeson, Amit Gupta

    Background Evaluation of cardiothoracic pathologies is a common indication for computed tomography (CT) in infants. However, CT is fraught with challenges specific to the patient population, such as increased sensitivity to radiation and inability to remain stationary during imaging. Objective This study investigates potential advantages of a high-pitch helical CT protocol for infants with cardiothoracic pathologies. Namely, we evaluate whether a high-pitch helical CT protocol can minimize radiation exposure without compromising image quality. Materials and methods This retrospective study included 98 consecutive cardiac protocol CT examinations of infants (56 males, 42 females; mean age 3.3 ± 2.8 months) performed at a tube voltage of 80 kV between 2016 and 2022. Forty-seven examinations were acquired with a non-gated conventional helical protocol on a multi-detector CT scanner (control group) and 51 were acquired with a non-gated high-pitch helical protocol on a dual-source CT scanner (high-pitch (HP) group). Patient characteristics, radiation exposure parameters, and imaging datasets were extracted from the picture archiving and communication system (PACS). Image quality was assessed subjectively by two radiologists who independently assigned ratings, and objectively through attenuation measurements. Results Radiation exposure was approximately 75% lower in the HP group (0.54 mSv vs. 2.46 mSv, P < .001). HP examinations demonstrated comparable, or better, image quality across all metrics in both subjective and objective analyses. In the subjective analysis, the HP group achieved superior ratings for visualization of the aorta (P = .04). In the objective analysis, the HP group achieved superior signal-to-noise ratio (SNR) in the left atrium (P < .001), left ventricle (P = .04), and aorta (P = .003), and superior contrast-to-noise ratio (CNR) in the left atrium (P = .003) and aorta (P = .009). Conclusion Our findings suggest that employing high-pitch helical CT protocols for evaluation of cardiothoracic pathologies in infants decreases radiation exposure while achieving similar to slightly better image quality compared to conventional helical CT protocols. Graphical Abstract


  • Clinical and imaging aspects of pulmonary embolism: a primer for radiologists

    by Syed Muhammad Awais Bukhari, Joshua G. Hunter, Kaustav Bera, Charit Tippareddy, Cody Reid Johnson, Shweta Ravi, Shashwat Chakraborti, Robert Chapman Gilkeson, Amit Gupta


  • Pre-procedural Planning for Left Atrial Appendage Closure with Cardiac Computed Tomography Angiography

    by Luis Augusto Palma Dallan, Amit Gupta, Robert Gilkeson, Steven J. Filby

  • Open Access

    Incidental Finding of Secondary Tumoral Calcinosis Following Cardiothoracic Surgery: The Role of Multimodality Imaging Including Spectral Detector Computed Tomography

    by Mihnea-Alexandru Găman, Mohamed M. Gad, Najdat Bazarbashi, Robert Gilkeson, Amit Gupta

    Tumoral calcinosis is a rare syndrome that affects mostly soft tissues. It is characterized by calcium salt deposition in the periarticular soft tissue surrounding bony structures forming slow-growing, seldom asymptomatic masses. This case report describes a 41-year-old male with end-stage renal disease on home hemodialysis, who presented with an unusual rapidly progressive mass overlying the manubrium and suprasternal notch, following recent cardiothoracic surgery, which was initially felt to be a hematoma. The case highlights the role of spectral detector computed tomography (SDCT) in reaching the correct diagnosis of tumoral calcinosis as well as demonstrating additional changes of ectopic parathyroid hyperplasia in the anterior mediastinum.


  • COVID-19 pandemic revisited: lessons the radiology community has learned a year later

    by Soheil Kooraki, Melina Hosseiny, Erik M. Velez, Amit Gupta, Robert Gilkeson, Steven S. Raman, Ali Gholamrezanezhad

    For more than 1 year, COVID-19 pandemic has impacted every aspect of our lives. This paper reviews the major challenges that the radiology community faced over the past year and the impact the pandemic had on the radiology practice, radiologist-in-training education, and radiology research. The lessons learned from COVID-19 pandemic can help the radiology community to be prepared for future outbreaks and new pandemics, preserve good habits, enhance cancer screening programs, and adapt to the changes in radiology education and scientific meetings.


  • Open Access

    A Novel Nodule Edge Sharpness Radiomic Biomarker Improves Performance of Lung-RADS for Distinguishing Adenocarcinomas from Granulomas on Non-Contrast CT Scans

    by Mehdi Alilou, Prateek Prasanna, Kaustav Bera, Amit Gupta, Prabhakar Rajiah, Michael Yang, Frank Jacono, Vamsidhar Velcheti, Robert Gilkeson, Philip Linden, et al.

    The aim of this study is to evaluate whether NIS radiomics can distinguish lung adenocarcinomas from granulomas on non-contrast CT scans, and also to improve the performance of Lung-RADS by reclassifying benign nodules that were initially assessed as suspicious. The screening or standard diagnostic non-contrast CT scans of 362 patients was divided into training (St, N = 145), validation (Sv, N = 145), and independent validation (Siv, N = 62) sets from different institutions. Nodules were identified and manually segmented on CT images by a radiologist. A series of 264 features relating to the edge sharpness transition from the inside to the outside of the nodule were extracted. The top 10 features were used to train a linear discriminant analysis (LDA) machine learning classifier on St. In conjunction with the LDA classifier, NIS radiomics classified nodules with an AUC of 0.82 ± 0.04, 0.77, and 0.71 respectively on St, Sv, and Siv. We evaluated the ability of the NIS classifier to determine the proportion of the patients in Sv that were identified initially as suspicious by Lung-RADS but were reclassified as benign by applying the NIS scores. The NIS classifier was able to correctly reclassify 46% of those lesions that were actually benign but deemed suspicious by Lung-RADS alone on Sv.


  • COVID-19 pneumonia versus EVALI, distinguishing the overlapping CT features in the COVID-19 era

    by Kianoush Ansari-Gilani, Andrew M Petraszko, Robert C Gilkeson


  • E-cigarette use related lung disease, review of clinical and imaging findings in 3 cases

    by Kianoush Ansari-Gilani, Andrew M. Petraszko, Catalina V. Teba, Allen R. Reeves, Amit Gupta, Aekta Gupta, Nikhil H. Ramaiya, Robert C. Gilkeson


  • Evaluation of the liver with virtual non-contrast: single institution study in 149 patients undergoing TAVR planning

    by Kai Roman Laukamp, Simon Lennartz, Vivian Ho, Nils Große Hokamp, David Zopfs, Amit Gupta, Frank Philipp Graner, Jan Borggrefe, Robert Gilkeson, Nikhil Ramaiya

    Objective: To evaluate accuracy of virtual-non-contrast images (VNC) compared to true-unenhanced-images (TNC) for evaluation of liver attenuation acquired using spectral-detector CT (SDCT). Methods: 149 patients who underwent multiphase transcatheter-aortic-valve-replacement (TAVR) SDCT-examinations [unenhanced-chest (TNC), CT-angiography chest (CTA-chest, early arterial-phase) and abdomen (CTA-abdomen, additional early arterial-phase after a second injection of contrast media)] were retrospectively included. VNC of CTA-chest (VNC-chest) and CTA-abdomen (VNC-abdomen) were reconstructed and compared to TNC. Region of interest-based measurement of mean attenuation (Hounsfield unit, HU) was applied in the following regions: liver, spleen, abdominal aorta and paraspinal muscle. Results: VNC accuracy was high in the liver, spleen, abdominal aorta and muscle for abdomen-scanning. For the liver, average attenuation was 59.0 ± 9.1 HU for TNC and 72.6 ± 9.5 HU for CTA-abdomen. Liver attenuation in VNC-abdomen (59.1 ± 6.4 HU) was not significantly different from attenuation in TNC (p > 0.05). In contrast, VNC was less accurate for chest-scanning: Due to the protocol, in CTA-chest no contrast media was present in the liver parenchyma as indicated by the same attenuation in TNC (59.0 ± 9.1 HU) and CTA-chest (58.8 ± 8.9 HU, p > 0.05). Liver attenuation in VNC-chest (56.2 ± 6.4 HU, p < 0.05) was, however, significantly lower than in TNC and CTA-chest implying an artificial reduction of attenuation. Conclusion: VNC performed well in a large cohort of TAVR-examinations yielding equivalent mean attenuations to TNC; however, application of this technique might be limited when no or very little contrast media is present in parenchyma, more precisely in an early arterial-phase of the liver. Advances in knowledge: This study showed that VNC can be reliably applied in cardiac protocols when certain limitations are considered


    • 1 January 2015
      • Vol. 7  (4) , 327
    Open Access

    Improved detection of an intravascular catheter using dual energy subtraction radiography.

    by Yukun Gao, Rosetta G Rowbottom, Luis A Landeras, Robert C Gilkeson