JHJoshua G. Hunter

Joshua G. Hunter

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Joshua G. Hunter has a total of 45 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Real-world impact of high-pitch helical CT on radiation exposure and image quality in infants being evaluated for cardiothoracic pathologies

    by Joshua G. Hunter, Kaustav Bera, Leslie Ciancibello, Syed Muhammad Awais Bukhari, Jennifer Sposato, Kianoush Ansari Gilani, Robert Gilkeson, Amit Gupta

    Background Evaluation of cardiothoracic pathologies is a common indication for computed tomography (CT) in infants. However, CT is fraught with challenges specific to the patient population, such as increased sensitivity to radiation and inability to remain stationary during imaging. Objective This study investigates potential advantages of a high-pitch helical CT protocol for infants with cardiothoracic pathologies. Namely, we evaluate whether a high-pitch helical CT protocol can minimize radiation exposure without compromising image quality. Materials and methods This retrospective study included 98 consecutive cardiac protocol CT examinations of infants (56 males, 42 females; mean age 3.3 ± 2.8 months) performed at a tube voltage of 80 kV between 2016 and 2022. Forty-seven examinations were acquired with a non-gated conventional helical protocol on a multi-detector CT scanner (control group) and 51 were acquired with a non-gated high-pitch helical protocol on a dual-source CT scanner (high-pitch (HP) group). Patient characteristics, radiation exposure parameters, and imaging datasets were extracted from the picture archiving and communication system (PACS). Image quality was assessed subjectively by two radiologists who independently assigned ratings, and objectively through attenuation measurements. Results Radiation exposure was approximately 75% lower in the HP group (0.54 mSv vs. 2.46 mSv, P < .001). HP examinations demonstrated comparable, or better, image quality across all metrics in both subjective and objective analyses. In the subjective analysis, the HP group achieved superior ratings for visualization of the aorta (P = .04). In the objective analysis, the HP group achieved superior signal-to-noise ratio (SNR) in the left atrium (P < .001), left ventricle (P = .04), and aorta (P = .003), and superior contrast-to-noise ratio (CNR) in the left atrium (P = .003) and aorta (P = .009). Conclusion Our findings suggest that employing high-pitch helical CT protocols for evaluation of cardiothoracic pathologies in infants decreases radiation exposure while achieving similar to slightly better image quality compared to conventional helical CT protocols. Graphical Abstract


  • Open Access

    Artificial Intelligence–Based Feature Analysis of Pulmonary Vein Morphology on Computed Tomography Scans and Risk of Atrial Fibrillation Recurrence After Catheter Ablation: A Multi-Site Study

    by Golnoush Asaeikheybari, Majd El-Harasis, Amit Gupta, M. Benjamin Shoemaker, John Barnard, Joshua Hunter, Rod S. Passman, Han Sun, Hyun Su Kim, Taylor Schilling, et al.

    BACKGROUND: Atrial fibrillation (AF) recurrence is common after catheter ablation. Pulmonary vein (PV) isolation is the cornerstone of AF ablation, but PV remodeling has been associated with the risk of AF recurrence. We aimed to evaluate whether artificial intelligence–based morphological features of primary and secondary PV branches on computed tomography images are associated with AF recurrence post-ablation. METHODS: Two artificial intelligence models were trained for the segmentation of computed tomography images, enabling the isolation of PV branches. Patients from Cleveland Clinic (N=135) and Vanderbilt University (N=594) were combined and divided into 2 sets for training and cross-validation (D 1 , n=218) and internal testing (D 2 , n=511). An independent validation set (D 3 , N=80) was obtained from University Hospitals of Cleveland. We extracted 48 fractal-based and 12 shape-based radiomic features from primary and secondary PV branches of patients with AF recurrence (AF+) and without recurrence after catheter ablation of AF (AF-). To predict AFrecurrence, 3 Gradient Boosting classification models based on significant features from primary (M p ), secondary (M s ), and combined (M c ) PV branches were built. RESULTS: Features relating to primary PVs were found to be associated with AF recurrence. The M p classifier achieved area under the curve values of 0.73, 0.71, and 0.70 across the 3 datasets. AF+ cases exhibited greater surface complexity in their primary PV area, as evidenced by higher fractal dimension values compared with AF- cases. The M s classifier results revealed a weaker association with AF+, suggesting higher relevance to AF recurrence post-ablation from primary PV branch morphology. CONCLUSIONS: This largest multi-institutional study to date revealed associations between artificial intelligence–extracted morphological features of the primary PV branches with AF recurrence in 809 patients from 3 sites. Future work will focus on enhancing the predictive ability of the classifier by integrating clinical, structural, and morphological features, including left atrial appendage and left atrium–related characteristics.


  • Real-World Performance of Pneumothorax-Detecting Artificial Intelligence Algorithm and its Impact on Radiologist Reporting Times

    by Joshua G. Hunter, Kaustav Bera, Neal Shah, Syed Muhammad Awais Bukhari, Colin Marshall, Danielle Caovan, Beverly Rosipko, Amit Gupta


  • Clinical and imaging aspects of pulmonary embolism: a primer for radiologists

    by Syed Muhammad Awais Bukhari, Joshua G. Hunter, Kaustav Bera, Charit Tippareddy, Cody Reid Johnson, Shweta Ravi, Shashwat Chakraborti, Robert Chapman Gilkeson, Amit Gupta


  • Open Access

    Clinical Implementation of an Artificial Intelligence Tool in the Detection and Management of Pneumothoraces in Patients With COVID-19

    by Joshua G. Hunter, Jonathan D. Pierce, Robert C. Gilkeson, Kaustav Bera, Amit Gupta

    In this report, we present a series involving critically ill patients with known coronavirus disease (COVID-19) infection where a portable X-ray machine equipped with artificial intelligence (AI) software aided in the urgent radiographic diagnosis of pneumothorax. These cases demonstrate how real-world clinical employment of AI tools capable of analyzing and prioritizing studies in the radiologist’s worklist can potentially lead to earlier detection of emergent findings like pneumothorax. The use of AI tools in this manner has the potential to both improve radiology workflow and add significant clinical value in managing critically ill patient populations, such as those with severe COVID-19 infection.


  • Open Access

    Imaging Depiction of Hypoxic Pulmonary Vasoconstriction Using Dual-Energy CT

    by Joshua G. Hunter, Priyanka Prajapati, Kaustav Bera, Aekta Gupta, Amit Gupta

    In this article, we aim to highlight the utility of dual-energy computed tomography (DECT) in demonstrating imaging changes due to hypoxic pulmonary vasoconstriction (HPV). DECT allows detailed image reconstructions that have been shown to better characterize cardiothoracic pathologies, as compared to conventional CT techniques. DECT simultaneously detects two different X-ray energies, which enables generation of iodine density maps, virtual monoenergetic images, and effective atomic number maps (Zeff), among others. DECT has been shown to have utility in the assessment of benign versus malignant pulmonary nodules, pulmonary embolism, myocardial perfusion defects, and other conditions. Herein, we describe four cases of indeterminate pulmonary pathology when imaged with conventional CT in which subsequent use of DECT-derived image reconstructions demonstrated HPV as the underlying pathophysiological mechanism. The goal of this article is to understand the imaging appearance of HPV on DECT and discuss how HPV may mimic other causes of perfusion defects.