Willyan Hasenkamp
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Willyan Hasenkamp has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Arnaud Bertsch
Microsystems Laboratory, Ecole Polytechnique Federale de Lausanne (EPFL), 1015 Lausanne, Switzerland
3 shared publications - Philippe Renaud
Microsystems Laboratory 4, Institute of Electrical and Micro Engineering, Ecole Polytechnique Fédérale de Lausanne (EPFL) , Lausanne
3 shared publications - Arash Arami
Department of Mechanical and Mechatronics Engineering, University of Waterloo, Waterloo, ON, Canada
2 shared publications - Kamiar Aminian
Laboratory of Movement Analysis and Measurement, Ecole Polytechnique Fédérale de Lausanne, 1015 Lausanne, Switzerland
2 shared publications A. Terrier
École Polytechnique Fédérale de Lausanne—EPFL, Lausanne, Switzerland
1 shared publicationB.M. Jolles
Centre Hospitalier Universitaire Vaudois and University of Lausanne, Lausanne, Switzerland
1 shared publication
Latest Publications
- 1 June 2014
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 36 (6) , 721-725
Smart instrumentation for determination of ligament stiffness and ligament balance in total knee arthroplasty
Ligament balance is an important and subjective task performed during total knee arthroplasty (TKA) procedure. For this reason, it is desirable to develop instruments to quantitatively assess the soft-tissue balance since excessive imbalance can accelerate prosthesis wear and lead to early surgical revision. The instrumented distractor proposed in this study can assist surgeons on performing ligament balance by measuring the distraction gap and applied load. Also the device allows the determination of the ligament stiffness which can contribute a better understanding of the intrinsic mechanical behavior of the knee joint. Instrumentation of the device involved the use of hall-sensors for measuring the distractor displacement and strain gauges to transduce the force. The sensors were calibrated and tested to demonstrate their suitability for surgical use. Results show the distraction gap can be measured reliably with 0.1mm accuracy and the distractive loads could be assessed with an accuracy in the range of 4N. These characteristics are consistent with those have been proposed, in this work, for a device that could assist on performing ligament balance while permitting surgeons evaluation based on his experience. Preliminary results from in vitro tests were in accordance with expected stiffness values for medial collateral ligament (MCL) and lateral collateral ligament (LCL).
- 1 June 2014
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 36 (6) , 721-725
Smart instrumentation for determination of ligament stiffness and ligament balance in total knee arthroplasty
Ligament balance is an important and subjective task performed during total knee arthroplasty (TKA) procedure. For this reason, it is desirable to develop instruments to quantitatively assess the soft-tissue balance since excessive imbalance can accelerate prosthesis wear and lead to early surgical revision. The instrumented distractor proposed in this study can assist surgeons on performing ligament balance by measuring the distraction gap and applied load. Also the device allows the determination of the ligament stiffness which can contribute a better understanding of the intrinsic mechanical behavior of the knee joint. Instrumentation of the device involved the use of hall-sensors for measuring the distractor displacement and strain gauges to transduce the force. The sensors were calibrated and tested to demonstrate their suitability for surgical use. Results show the distraction gap can be measured reliably with 0.1mm accuracy and the distractive loads could be assessed with an accuracy in the range of 4N. These characteristics are consistent with those have been proposed, in this work, for a device that could assist on performing ligament balance while permitting surgeons evaluation based on his experience. Preliminary results from in vitro tests were in accordance with expected stiffness values for medial collateral ligament (MCL) and lateral collateral ligament (LCL).
- Open Access
- 11 May 2013
- Published by Springer Nature in Biomedical Microdevices
- Vol. 15 (5) , 831-839
Design and test of a MEMS strain-sensing device for monitoring artificial knee implants
This paper describes the development of a polyimide-based MEMS strain-sensing device. Finite element analysis was used to investigate an artificial knee implant and assist on device design and to optimize sensing characteristics. The sensing element of the device was fabricated using polyimide micromachining with embedded thin-metallic wires and placed into a knee prosthesis. The device was evaluated experimentally in a mechanical knee simulator using static and dynamic axial load conditions similar to those encountered in vivo. Results indicates the sensor is capable of measuring the strain associated to the total axial forces in the range of approximately 4 times body weight with a good sensitivity and accuracy for events happening within 1 s time window.
- 11 May 2013
- Published by Springer Nature in Biomedical Microdevices
- Vol. 15 (5) , 831-839
Open AccessDesign and test of a MEMS strain-sensing device for monitoring artificial knee implants
This paper describes the development of a polyimide-based MEMS strain-sensing device. Finite element analysis was used to investigate an artificial knee implant and assist on device design and to optimize sensing characteristics. The sensing element of the device was fabricated using polyimide micromachining with embedded thin-metallic wires and placed into a knee prosthesis. The device was evaluated experimentally in a mechanical knee simulator using static and dynamic axial load conditions similar to those encountered in vivo. Results indicates the sensor is capable of measuring the strain associated to the total axial forces in the range of approximately 4 times body weight with a good sensitivity and accuracy for events happening within 1 s time window.
- Open Access
- 26 May 2012
- Published by Springer Nature in Biomedical Microdevices
- Vol. 14 (5) , 819-828
Polyimide/SU-8 catheter-tip MEMS gauge pressure sensor
This paper describes the development of a polyimide/SU-8 catheter-tip MEMS gauge pressure sensor. Finite element analysis was used to investigate critical parameters, impacting on the device design and sensing characteristics. The sensing element of the device was fabricated by polyimide-based micromachining on a flexible membrane, using embedded thin-film metallic wires as piezoresistive elements. A chamber containing this flexible membrane was sealed using an adapted SU-8 bonding technique. The device was evaluated experimentally and its overall performance compared with a commercial silicon-based pressure sensor. Furthermore, the device use was demonstrated by measuring blood pressure and heart rate in vivo.
- 26 May 2012
- Published by Springer Nature in Biomedical Microdevices
- Vol. 14 (5) , 819-828
Open AccessPolyimide/SU-8 catheter-tip MEMS gauge pressure sensor
This paper describes the development of a polyimide/SU-8 catheter-tip MEMS gauge pressure sensor. Finite element analysis was used to investigate critical parameters, impacting on the device design and sensing characteristics. The sensing element of the device was fabricated by polyimide-based micromachining on a flexible membrane, using embedded thin-film metallic wires as piezoresistive elements. A chamber containing this flexible membrane was sealed using an adapted SU-8 bonding technique. The device was evaluated experimentally and its overall performance compared with a commercial silicon-based pressure sensor. Furthermore, the device use was demonstrated by measuring blood pressure and heart rate in vivo.