BWBruce R. Whiting

Bruce R. Whiting

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Bruce R. Whiting has a total of 25 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Validation of CT dose‐reduction simulation

    by Parinaz Massoumzadeh, Steven Don, Charles F. Hildebolt, Kyongtae T. Bae, Bruce R. Whiting

    The objective of this research was to develop and validate a custom computed tomography dose‐reduction simulation technique for producing images that have an appearance consistent with the same scan performed at a lower mAs (with fixed kVp, rotation time, and collimation). Synthetic noise is added to projection (sinogram) data, incorporating a stochastic noise model that includes energy‐integrating detectors, tube‐current modulation, bowtie beam filtering, and electronic system noise. Experimental methods were developed to determine the parameters required for each component of the noise model. As a validation, the outputs of the simulations were compared to measurements with cadavers in the image domain and with phantoms in both the sinogram and image domain, using an unbiased root‐mean‐square relative error metric to quantify agreement in noise processes. Four‐alternative forced‐choice (4AFC) observer studies were conducted to confirm the realistic appearance of simulated noise, and the effects of various system model components on visual noise were studied. The “just noticeable difference (JND)” in noise levels was analyzed to determine the sensitivity of observers to changes in noise level. Individual detector measurements were shown to be normally distributed , justifying the use of a Gaussian random noise generator for simulations. Phantom tests showed the ability to match original and simulated noise variance in the sinogram domain to within (standard deviation), which was then propagated into the image domain with errors less than . Cadaver measurements indicated that image noise was matched to within . More importantly, the 4AFC observer studies indicated that the simulated images were realistic, i.e., no detectable difference between simulated and original images was observed. JND studies indicated that observers’ sensitivity to change in noise levels corresponded to a 25% difference in dose, which is far larger than the noise accuracy achieved by simulation. In summary, the dose‐reduction simulation tool demonstrated excellent accuracy in providing realistic images. The methodology promises to be a useful tool for researchers and radiologists to explore dose reduction protocols in an effort to produce diagnostic images with radiation dose “as low as reasonably achievable.”


  • Open Access

    Use of Computed Tomography Scans for Cochlear Implants

    by Bruce R. Whiting, Timothy A. Holden, Barry S. Brunsden, Charles C. Finley, Margaret W. Skinner

    While 3-dimensional (3D) imaging by computed tomography has long been desirable for research and treatment of cochlear-implant patients, technical challenges have limited its wide application. Recent developments in scanner hardware and image processing techniques now allow image quality improvements that make clinical applications feasible. Validation experiments were performed to characterize a new methodology and its imaging performance.


    • 1 April 2007
      • Vol. 197, 2-24

    In vivo estimates of the position of advanced bionics electrode arrays in the human cochlea.

    by Margaret W Skinner, Timothy A Holden, Bruce R Whiting, Arne H Voie, Barry Brunsden, J Gail Neely, Eugene A Saxon, Timothy E Hullar, Charles C Finley

    A new technique for determining the position of each electrode in the cochlea is described and applied to spiral computed tomography data from 15 patients implanted with Advanced Bionics HiFocus I, Ij, or Helix arrays. ANALYZE imaging software was used to register 3-dimensional image volumes from patients' preoperative and postoperative scans and from a single body donor whose unimplanted ears were scanned clinically, with micro computed tomography and with orthogonal-plane fluorescence optical sectioning (OPFOS) microscopy. By use of this registration, we compared the atlas of OPFOS images of soft tissue within the body donor's cochlea with the bone and fluid/ tissue boundary available in patient scan data to choose the midmodiolar axis position and judge the electrode position in the scala tympani or scala vestibuli, including the distance to the medial and lateral scalar walls. The angular rotation 0 degrees start point is a line joining the midmodiolar axis and the middle of the cochlear canal entry from the vestibule. The group mean array insertion depth was 477 degrees (range, 286 degrees to 655 degrees). The word scores were negatively correlated (r = -0.59; p = .028) with the number of electrodes in the scala vestibuli. Although the individual variability in all measures was large, repeated patterns of suboptimal electrode placement were observed across subjects, underscoring the applicability of this technique.


  • Is There a Relation between Speech Recognition and the Position of Cochlear Implant Electrodes in the Inner Ear?

    by Margaret W. Skinner, Darlene R. Ketten, Laura K. Holden, Bruce R. Whiting, Lawrence T. Cohen, Gary W. Harding, Kyongtae Bae, Peter G. Smith, George A. Gates, J. Gail Neely, et al.

    The anatomical position of the Nucleus-22 electrode array in the cochleae of 33 postlinguistically deaf adults has been estimated from spiral CT images.[ 1 ] [ 2 ] For 13 of these adults, the position of individual electrodes also has been derived from 2D radiographs[ 3 ] [ 4 ] with projection of the CT-derived array onto the radiographs.[ 5 ] Array insertion depth of the most apical electrode expressed as percentage of total cochlear canal length was significantly correlated with mean NU-6 word score for the 26 patients who had used the spectral peak (SPEAK) strategy for a year at the time of testing (r=0.452; p=0.020). This correlation is modest because the site of electrical stimulation in the cochlea is only one factor contributing to word recognition. It is well known that age at implantation and duration of deafness have a negative effect and number of years implant use has a positive effect on word recognition in postlinguistically deaf adults.[ 6 ] [ 7 ] Analyses of patients' scores suggest that etiologies that adversely affect the number of remaining auditory neurons (e.g., bacterial labyrinthitis, syphilis) or abnormal electrical current paths within the cochlea (e.g., otosclerosis) are associated with scores below the regression line. A number of patients with less than full insertion (i.e., between 52 and 64% of the total cochlear length) had excellent verbal skills and word scores substantially higher than the regression line. Because there was less than full insertion, the frequency bands of incoming sound assigned to the active electrodes were substantially lower than the estimated characteristic frequency of nearby neurons for these patients. For one patient, the frequency band assigned to the most apical electrode, 22 (paired with electrode 20), was 120 to 280 Hz in the speech processor program; the characteristic frequency estimated at this most apical electrode position was 1485 Hz. It is hypothesized that these patients' high scores were associated with their above average verbal skills, a year or more of implant experience, above average survival of auditory neurons, and sufficient central auditory nervous system plasticity to adapt to the shift in frequency of incoming sound to a higher pitch percept from stimulation with the implant than would normally be perceived acoustically. Documented improvement in these patients' word scores obtained at 3 months, 6 months, and yearly intervals thereafter with the multipeak (MPEAK) and SPEAK strategies lends support for the hypothesized neural plasticity.