Latest Publications
- 1 April 2007
- Vol. 197, 2-24
In vivo estimates of the position of advanced bionics electrode arrays in the human cochlea.
A new technique for determining the position of each electrode in the cochlea is described and applied to spiral computed tomography data from 15 patients implanted with Advanced Bionics HiFocus I, Ij, or Helix arrays. ANALYZE imaging software was used to register 3-dimensional image volumes from patients' preoperative and postoperative scans and from a single body donor whose unimplanted ears were scanned clinically, with micro computed tomography and with orthogonal-plane fluorescence optical sectioning (OPFOS) microscopy. By use of this registration, we compared the atlas of OPFOS images of soft tissue within the body donor's cochlea with the bone and fluid/ tissue boundary available in patient scan data to choose the midmodiolar axis position and judge the electrode position in the scala tympani or scala vestibuli, including the distance to the medial and lateral scalar walls. The angular rotation 0 degrees start point is a line joining the midmodiolar axis and the middle of the cochlear canal entry from the vestibule. The group mean array insertion depth was 477 degrees (range, 286 degrees to 655 degrees). The word scores were negatively correlated (r = -0.59; p = .028) with the number of electrodes in the scala vestibuli. Although the individual variability in all measures was large, repeated patterns of suboptimal electrode placement were observed across subjects, underscoring the applicability of this technique.
- 1 April 2007
- Vol. 197, 2-24
In vivo estimates of the position of advanced bionics electrode arrays in the human cochlea.
A new technique for determining the position of each electrode in the cochlea is described and applied to spiral computed tomography data from 15 patients implanted with Advanced Bionics HiFocus I, Ij, or Helix arrays. ANALYZE imaging software was used to register 3-dimensional image volumes from patients' preoperative and postoperative scans and from a single body donor whose unimplanted ears were scanned clinically, with micro computed tomography and with orthogonal-plane fluorescence optical sectioning (OPFOS) microscopy. By use of this registration, we compared the atlas of OPFOS images of soft tissue within the body donor's cochlea with the bone and fluid/ tissue boundary available in patient scan data to choose the midmodiolar axis position and judge the electrode position in the scala tympani or scala vestibuli, including the distance to the medial and lateral scalar walls. The angular rotation 0 degrees start point is a line joining the midmodiolar axis and the middle of the cochlear canal entry from the vestibule. The group mean array insertion depth was 477 degrees (range, 286 degrees to 655 degrees). The word scores were negatively correlated (r = -0.59; p = .028) with the number of electrodes in the scala vestibuli. Although the individual variability in all measures was large, repeated patterns of suboptimal electrode placement were observed across subjects, underscoring the applicability of this technique.
- 11 April 2002
- Published by Georg Thieme Verlag KG in Seminars in Hearing
- Vol. 23 (1) , 097-098
Is There a Relation between Speech Recognition and the Position of Cochlear Implant Electrodes in the Inner Ear?
The anatomical position of the Nucleus-22 electrode array in the cochleae of 33 postlinguistically deaf adults has been estimated from spiral CT images.[ 1 ] [ 2 ] For 13 of these adults, the position of individual electrodes also has been derived from 2D radiographs[ 3 ] [ 4 ] with projection of the CT-derived array onto the radiographs.[ 5 ] Array insertion depth of the most apical electrode expressed as percentage of total cochlear canal length was significantly correlated with mean NU-6 word score for the 26 patients who had used the spectral peak (SPEAK) strategy for a year at the time of testing (r=0.452; p=0.020). This correlation is modest because the site of electrical stimulation in the cochlea is only one factor contributing to word recognition. It is well known that age at implantation and duration of deafness have a negative effect and number of years implant use has a positive effect on word recognition in postlinguistically deaf adults.[ 6 ] [ 7 ] Analyses of patients' scores suggest that etiologies that adversely affect the number of remaining auditory neurons (e.g., bacterial labyrinthitis, syphilis) or abnormal electrical current paths within the cochlea (e.g., otosclerosis) are associated with scores below the regression line. A number of patients with less than full insertion (i.e., between 52 and 64% of the total cochlear length) had excellent verbal skills and word scores substantially higher than the regression line. Because there was less than full insertion, the frequency bands of incoming sound assigned to the active electrodes were substantially lower than the estimated characteristic frequency of nearby neurons for these patients. For one patient, the frequency band assigned to the most apical electrode, 22 (paired with electrode 20), was 120 to 280 Hz in the speech processor program; the characteristic frequency estimated at this most apical electrode position was 1485 Hz. It is hypothesized that these patients' high scores were associated with their above average verbal skills, a year or more of implant experience, above average survival of auditory neurons, and sufficient central auditory nervous system plasticity to adapt to the shift in frequency of incoming sound to a higher pitch percept from stimulation with the implant than would normally be perceived acoustically. Documented improvement in these patients' word scores obtained at 3 months, 6 months, and yearly intervals thereafter with the multipeak (MPEAK) and SPEAK strategies lends support for the hypothesized neural plasticity.
- 11 April 2002
- Published by Georg Thieme Verlag KG in Seminars in Hearing
- Vol. 23 (1) , 097-098
Is There a Relation between Speech Recognition and the Position of Cochlear Implant Electrodes in the Inner Ear?
The anatomical position of the Nucleus-22 electrode array in the cochleae of 33 postlinguistically deaf adults has been estimated from spiral CT images.[ 1 ] [ 2 ] For 13 of these adults, the position of individual electrodes also has been derived from 2D radiographs[ 3 ] [ 4 ] with projection of the CT-derived array onto the radiographs.[ 5 ] Array insertion depth of the most apical electrode expressed as percentage of total cochlear canal length was significantly correlated with mean NU-6 word score for the 26 patients who had used the spectral peak (SPEAK) strategy for a year at the time of testing (r=0.452; p=0.020). This correlation is modest because the site of electrical stimulation in the cochlea is only one factor contributing to word recognition. It is well known that age at implantation and duration of deafness have a negative effect and number of years implant use has a positive effect on word recognition in postlinguistically deaf adults.[ 6 ] [ 7 ] Analyses of patients' scores suggest that etiologies that adversely affect the number of remaining auditory neurons (e.g., bacterial labyrinthitis, syphilis) or abnormal electrical current paths within the cochlea (e.g., otosclerosis) are associated with scores below the regression line. A number of patients with less than full insertion (i.e., between 52 and 64% of the total cochlear length) had excellent verbal skills and word scores substantially higher than the regression line. Because there was less than full insertion, the frequency bands of incoming sound assigned to the active electrodes were substantially lower than the estimated characteristic frequency of nearby neurons for these patients. For one patient, the frequency band assigned to the most apical electrode, 22 (paired with electrode 20), was 120 to 280 Hz in the speech processor program; the characteristic frequency estimated at this most apical electrode position was 1485 Hz. It is hypothesized that these patients' high scores were associated with their above average verbal skills, a year or more of implant experience, above average survival of auditory neurons, and sufficient central auditory nervous system plasticity to adapt to the shift in frequency of incoming sound to a higher pitch percept from stimulation with the implant than would normally be perceived acoustically. Documented improvement in these patients' word scores obtained at 3 months, 6 months, and yearly intervals thereafter with the multipeak (MPEAK) and SPEAK strategies lends support for the hypothesized neural plasticity.
- 27 February 2002
- Published by Springer Nature in Journal of the Association for Research in Otolaryngology
- Vol. 3 (3) , 332-350
CT-Derived Estimation of Cochlear Morphology and Electrode Array Position in Relation to Word Recognition in Nucleus-22 Recipients
This study extended the findings of Ketten et al. [Ann. Otol. Rhinol. Laryngol. Suppl. 175:1–16 (1998)] by estimating the three-dimensional (3D) cochlear lengths, electrode array intracochlear insertion depths, and characteristic frequency ranges for 13 more Nucleus-22 implant recipients based on in vivo computed tomography (CT) scans. Array insertion depths were correlated with NU-6 word scores (obtained one year after SPEAK strategy use) by these patients and the 13 who used the SPEAK strategy from the Ketten et al. study. For these 26 patients, the range of cochlear lengths was 29.1–37.4 mm. Array insertion depth range was 11.9–25.9 mm, and array insertion depth estimated from the surgeon's report was 1.14 mm longer than CT-based estimates. Given the assumption that the human hearing range is fixed (20–20,000 Hz) regardless of cochlear length, characteristic frequencies at the most apical electrode (estimated with Greenwood's equation [Greenwood DD (1990) A cochlear frequency–position function of several species–29 years later. J Acoust. Soc. Am. 33: 1344–1356] and a patient-specific constant as) ranged from 308 to 3674 Hz. Patients' NU-6 word scores were significantly correlated with insertion depth as a percentage of total cochlear length (R = 0.452; r2 = 0.204; p = 0.020), suggesting that part of the variability in word recognition across implant recipients can be accounted for by the position of the electrode array in the cochlea. However, NU-6 scores ranged from 4% to 81% correct for patients with array insertion depths between 47% and 68% of total cochlear length. Lower scores appeared related to low spiral ganglion cell survival (e.g., lues), aberrant current paths that produced facial nerve stimulation by apical electrodes (i.e., otosclerosis), central auditory processing difficulty, below-average verbal abilities, and early Alzheimer's disease. Higher scores appeared related to patients' high-average to above-average verbal abilities. Because most patients' scores increased with SPEAK use, it is hypothesized that they accommodated to the shift in frequency of incoming sound to a higher pitch percept with the implant than would normally be perceived acoustically.
- 27 February 2002
- Published by Springer Nature in Journal of the Association for Research in Otolaryngology
- Vol. 3 (3) , 332-350
CT-Derived Estimation of Cochlear Morphology and Electrode Array Position in Relation to Word Recognition in Nucleus-22 Recipients
This study extended the findings of Ketten et al. [Ann. Otol. Rhinol. Laryngol. Suppl. 175:1–16 (1998)] by estimating the three-dimensional (3D) cochlear lengths, electrode array intracochlear insertion depths, and characteristic frequency ranges for 13 more Nucleus-22 implant recipients based on in vivo computed tomography (CT) scans. Array insertion depths were correlated with NU-6 word scores (obtained one year after SPEAK strategy use) by these patients and the 13 who used the SPEAK strategy from the Ketten et al. study. For these 26 patients, the range of cochlear lengths was 29.1–37.4 mm. Array insertion depth range was 11.9–25.9 mm, and array insertion depth estimated from the surgeon's report was 1.14 mm longer than CT-based estimates. Given the assumption that the human hearing range is fixed (20–20,000 Hz) regardless of cochlear length, characteristic frequencies at the most apical electrode (estimated with Greenwood's equation [Greenwood DD (1990) A cochlear frequency–position function of several species–29 years later. J Acoust. Soc. Am. 33: 1344–1356] and a patient-specific constant as) ranged from 308 to 3674 Hz. Patients' NU-6 word scores were significantly correlated with insertion depth as a percentage of total cochlear length (R = 0.452; r2 = 0.204; p = 0.020), suggesting that part of the variability in word recognition across implant recipients can be accounted for by the position of the electrode array in the cochlea. However, NU-6 scores ranged from 4% to 81% correct for patients with array insertion depths between 47% and 68% of total cochlear length. Lower scores appeared related to low spiral ganglion cell survival (e.g., lues), aberrant current paths that produced facial nerve stimulation by apical electrodes (i.e., otosclerosis), central auditory processing difficulty, below-average verbal abilities, and early Alzheimer's disease. Higher scores appeared related to patients' high-average to above-average verbal abilities. Because most patients' scores increased with SPEAK use, it is hypothesized that they accommodated to the shift in frequency of incoming sound to a higher pitch percept with the implant than would normally be perceived acoustically.
- 1 August 1999
- Published by American Speech Language Hearing Association in Journal of Speech, Language, and Hearing Research
- Vol. 42 (4) , 814-828
Comparison of Two Methods for Selecting Minimum Stimulation Levels Used in Programming the Nucleus 22 Cochlear Implant
Minimum stimulation levels for active electrodes in a Nucleus 22 cochlear implant were set at threshold (clinical default value) and raised levels ( M =+2.04 dB) to determine if raised levels would improve recipients' understanding of soft speech sounds with the SPEAK speech coding strategy. Eight postlinguistically deaf adults participated in a 4-phase A 1 B 1 A 2 B 2 , test design. Speech recognition was evaluated with consonant-vowel nucleus-consonant (CNC) words in quiet and sentences in noise, both presented at 50, 60, and 70 dB SPL during 2 weekly sessions at the end of each phase. Group mean scores were significantly higher with the raised level program for words and phonemes at 50 and 60 dB SPL and for sentences at 50 and 70 dB SPL. All participants chose to use the raised level program in everyday life at the end of the study. The results suggest that clinical use of a raised level program for Nucleus 22 recipients has the potential to make soft sounds louder and, therefore, more salient in everyday life. Further research is needed to determine if this approach is appropriate for other cochlear implant devices.
- 1 August 1999
- Published by American Speech Language Hearing Association in Journal of Speech, Language, and Hearing Research
- Vol. 42 (4) , 814-828
Comparison of Two Methods for Selecting Minimum Stimulation Levels Used in Programming the Nucleus 22 Cochlear Implant
Minimum stimulation levels for active electrodes in a Nucleus 22 cochlear implant were set at threshold (clinical default value) and raised levels ( M =+2.04 dB) to determine if raised levels would improve recipients' understanding of soft speech sounds with the SPEAK speech coding strategy. Eight postlinguistically deaf adults participated in a 4-phase A 1 B 1 A 2 B 2 , test design. Speech recognition was evaluated with consonant-vowel nucleus-consonant (CNC) words in quiet and sentences in noise, both presented at 50, 60, and 70 dB SPL during 2 weekly sessions at the end of each phase. Group mean scores were significantly higher with the raised level program for words and phonemes at 50 and 60 dB SPL and for sentences at 50 and 70 dB SPL. All participants chose to use the raised level program in everyday life at the end of the study. The results suggest that clinical use of a raised level program for Nucleus 22 recipients has the potential to make soft sounds louder and, therefore, more salient in everyday life. Further research is needed to determine if this approach is appropriate for other cochlear implant devices.