RBRamya Balachandran

Ramya Balachandran

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ramya Balachandran has a total of 53 co-authors. Here are the top co-authors by number of shared publications:

  • Robert Frederick Labadie

    Department of Otolaryngology-Head and Neck Surgery, Vanderbilt University, Nashville, TN, USA

    11 shared publications
  • J. Michael Fitzpatrick

    Department of Electrical Engineering and Computer Science, Vanderbilt University, Nashville, USA

    8 shared publications
  • Benoit M. Dawant

    Department of Otolaryngology, Vanderbilt University Medical Center, Nashville, Tennessee; †Department of Otorhinolaryngology, The University of Oklahoma Health Sciences Center, Oklahoma City, Oklahoma; and ‡Department of Electrical Engineering and Computer Science, Vanderbilt University, Nashville, Tennessee, U.S.A.

    6 shared publications
  • J. Michael Fitzpatrick

    G Department of Electrical Engineering and Computer Science, Vanderbilt University, Nashville, TN

    6 shared publications
  • Robert F. Labadie

    Department of Otolaryngology, Vanderbilt University Medical Center, Nashville, Tennessee; †Department of Otorhinolaryngology, The University of Oklahoma Health Sciences Center, Oklahoma City, Oklahoma; and ‡Department of Electrical Engineering and Computer Science, Vanderbilt University, Nashville, Tennessee, U.S.A.

    6 shared publications
  • Jason E. Mitchell

    Department of Mechanical Engineering, Vanderbilt University, Nashville, TN

    5 shared publications

Latest Publications

  • A Compact, Bone-Attached Robot for Mastoidectomy

    by Neal P. Dillon, Ramya Balachandran, J. Michael Fitzpatrick, Michael A. Siebold, Robert F. Labadie, George B. Wanna, Thomas J. Withrow, Robert J. Webster

    Otologic surgery often involves a mastoidectomy, which is the removal of a portion of the mastoid region of the temporal bone, to safely access the middle and inner ear. The surgery is challenging because many critical structures are embedded within the bone, making them difficult to see and requiring a high level of accuracy with the surgical dissection instrument, a high-speed drill. We propose to automate the mastoidectomy portion of the surgery using a compact, bone-attached robot. The system described in this paper is a milling robot with four degrees-of-freedom (DOF) that is fixed to the patient during surgery using a rigid positioning frame screwed into the surface of the bone. The target volume to be removed is manually identified by the surgeon pre-operatively in a computed tomography (CT) scan and converted to a milling path for the robot. The surgeon attaches the robot to the patient in the operating room and monitors the procedure. Several design considerations are discussed in the paper as well as the proposed surgical workflow. The mean targeting error of the system in free space was measured to be 0.5 mm or less at vital structures. Four mastoidectomies were then performed in cadaveric temporal bones, and the error at the edges of the target volume was measured by registering a postoperative computed tomography (CT) to the pre-operative CT. The mean error along the border of the milled cavity was 0.38 mm, and all critical anatomical structures were preserved.


  • Minimally Invasive Image-Guided Access for Drainage of Petrous Apex Lesions

    by Ramya Balachandran, Betty S. Tsai, Tara Ramachandra, Jack H. Noble, Benoit M. Dawant, Robert F. Labadie, Marc L. Bennett

    Objective In this case report, we present a novel, minimally invasive image-guided approach to drainage of a petrous apex lesion. Patient(s) A 34-year-old man diagnosed with a petrous apex lesion consistent with cholesterol granuloma. The granuloma was large and caused mild compression of the brainstem with associated neurologic symptoms and seizure-like activity. Interventions Based on the anatomic location of the lesion, it was determined that the treatment plan would be to surgically drain the lesion via 2 linear paths—one after an infralabyrinthine approach and the other a subarcuate approach. Customized microstereotactic frames that mount on bone-implanted markers and constrain the drill along the desired path were used to accurately drill these desired paths and avoid damage to surrounding critical structures. After a simple mastoidectomy, the petrous apex was successfully reached without damage to vital adjacent structures by drilling the 2 linear channels using 2 custom microstereotactic frames. Main Outcome Measures Viscous brown liquid and debris was recovered by irrigating through one of the channels and suctioning through the other. Results Drainage of the petrous apex was successfully performed via 2 linear channels without any complications. Custom microstereotactic frames were used to accurately drill those linear channels. Postoperative CT ensured no complications. Postoperative course of the patient was remarkable with normal hearing and normal facial nerve function. Conclusion We presented a successful implementation of an image-guided approach to drain petrous apex.


  • Clinical testing of an alternate method of inserting bone-implanted fiducial markers

    by Ramya Balachandran, Mark A. Fritz, Mary S. Dietrich, Andrei Danilchenko, Jason E. Mitchell, Veronica L. Oldfield, Wendy W. Lipscomb, J. Michael Fitzpatrick, Joseph S. Neimat, Peter E. Konrad, et al.

    Deep brain stimulation (DBS) surgery utilizes image guidance via bone-implanted fiducial markers to achieve the desired submillimetric accuracy and to provide means for attaching microstereotactic frames. For maximal benefit, the markers must be inserted to the correct depth since over-insertion leads to stripping and under-insertion leads to instability.


  • Minimally Invasive Image‐Guided Cochlear Implantation for Pediatric Patients: Clinical Feasibility Study

    by Ramya Balachandran, Fitsum A. Reda, Jack H. Noble, Grégoire S. Blachon, Benoit M. Dawant, J. Michael Fitzpatrick, Robert F. Labadie

    Objective: Minimally invasive image‐guided cochlear implantation (CI) involves accessing the cochlea via a linear path from the lateral skull to the cochlea avoiding vital structures including the facial nerve. Herein, we describe and demonstrate the feasibility of the technique for pediatric patients.Study Design: Prospective.Setting: Children's Hospital.Subjects and Methods: Thirteen pediatric patients (1.5 to 8 years) undergoing traditional CI participated in this Institutional Review Board–approved study. Three fiducial markers were bone‐implanted surrounding the ear, and a CT scan was acquired. The CT scan was processed to identify the marker locations and critical structures of the temporal bone. A safe linear path was determined to target the cochlea avoiding damage to vital structures. A custom microstereotactic frame was fabricated that would mount on the fiducial markers and constrain a tool to the desired trajectory. After traditional mastoidectomy and prior to cochleostomy, the custom microstereotactic frame was mounted on the bone‐implanted markers to confirm that the achieved trajectory was safe and accurately accessed the cochlea.Results: For all the 13 patients, it was possible to determine a safe trajectory to the cochlea. Custom microstereotactic frames were validated successfully on 9 patients. Two of these patients had inner ear malformations, and this technique helped the surgeon confirm ideal location for cochleostomy. For patients with normal anatomy, the mean and standard deviation of the closest distance of the trajectory to facial nerve and chorda tympani were 1.1 ± 0.3 mm and 1.2 ± 0.5 mm, respectively.Conclusion: Minimally invasive image‐guided CI is feasible for pediatric patients.


  • Validation of minimally invasive, image-guided cochlear implantation using Advanced Bionics, Cochlear, and Medel electrodes in a cadaver model

    by Theodore R. McRackan, Ramya Balachandran, Grégoire S. Blachon, Jason E. Mitchell, Jack H. Noble, Charles G. Wright, J. Michael Fitzpatrick, Benoit M. Dawant, Robert F. Labadie

    Validation of a novel minimally invasive, image-guided approach to implant electrodes from three FDA-approved manufacturers—Medel, Cochlear, and Advanced Bionics—in the cochlea via a linear tunnel from the lateral cranium through the facial recess to the cochlea.


  • A Manually Operated, Advance Off-Stylet Insertion Tool for Minimally Invasive Cochlear Implantation Surgery

    by L. B. Kratchman, D. Schurzig, T. R. McRackan, R. Balachandran, J. H. Noble, R. J. Webster, R. F. Labadie

    The current technique for cochlear implantation (CI) surgery requires a mastoidectomy to gain access to the cochlea for electrode array insertion. It has been shown that microstereotactic frames can enable an image-guided, minimally invasive approach to CI surgery called percutaneous cochlear implantation (PCI) that uses a single drill hole for electrode array insertion, avoiding a more invasive mastoidectomy. Current clinical methods for electrode array insertion are not compatible with PCI surgery because they require a mastoidectomy to access the cochlea; thus, we have developed a manually operated electrode array insertion tool that can be deployed through a PCI drill hole. The tool can be adjusted using a preoperative CT scan for accurate execution of the advance off-stylet (AOS) insertion technique and requires less skill to operate than is currently required to implant electrode arrays. We performed three cadaver insertion experiments using the AOS technique and determined that all insertions were successful using CT and microdissection.


  • Design of a Bone-Attached Parallel Robot for Percutaneous Cochlear Implantation

    by Louis B. Kratchman, Grégoire S. Blachon, Thomas J. Withrow, Ramya Balachandran, Robert F. Labadie, Robert J. Webster

    Access to the cochlea requires drilling in close proximity to bone-embedded nerves, blood vessels, and other structures, the violation of which can result in complications for the patient. It has recently been shown that microstereotactic frames can enable an image-guided percutaneous approach, removing reliance on human experience and hand-eye coordination, and reducing trauma. However, constructing current microstereotactic frames disrupts the clinical workflow, requiring multiday intrasurgical manufacturing delays, or an on-call machine shop in or near the hospital. In this paper, we describe a new kind of microsterotactic frame that obviates these delay and infrastructure issues by being repositionable. Inspired by the prior success of bone-attached parallel robots in knee and spinal procedures, we present an automated image-guided microstereotactic frame. Experiments demonstrate a mean accuracy at the cochlea of 0.20 ± 0.07 mm in phantom testing with trajectories taken from a human clinical dataset. We also describe a cadaver experiment evaluating the entire image-guided surgery pipeline, where we achieved an accuracy of 0.38 mm at the cochlea.


  • Evaluation of portable CT scanners for otologic image-guided surgery

    by Ramya Balachandran, Daniel Schurzig, J. Michael Fitzpatrick, Robert F. Labadie

    Purpose Portable CT scanners are beneficial for diagnosis in the intensive care unit, emergency room, and operating room. Portable fixed-base versus translating-base CT systems were evaluated for otologic image-guided surgical (IGS) applications based on geometric accuracy and utility for percutaneous cochlear implantation. Methods Five cadaveric skulls were fitted with fiducial markers and scanned using both a translating-base, 8-slice CT scanner (CereTom®) and a fixed-base, flat-panel, volume CT (fpVCT) scanner (Xoran xCAT®). Images were analyzed for: (a) subjective quality (i.e., noise), (b) consistency of attenuation measurements (Hounsfield units) across similar tissue, and (c) geometric accuracy of fiducial marker positions. The utility of these scanners in clinical IGS cases was tested. Results Five cadaveric specimens were scanned using each of the scanners. The translating-base, 8-slice CT scanner had spatially consistent Hounsfield units, and the image quality was subjectively good. However, because of movement variations during scanning, the geometric accuracy of fiducial marker positions was low. The fixed-base, fpVCT system had high spatial resolution, but the images were noisy and had spatially inconsistent attenuation measurements, while the geometric representation of the fiducial markers was highly accurate. Conclusion Two types of portable CT scanners were evaluated for otologic IGS. The translating-base, 8-slice CT scanner provided better image quality than a fixed-base, fpVCT scanner. However, the inherent error in three-dimensional spatial relationships by the translating-based system makes it suboptimal for otologic IGS use.


  • Insertion of electrode array using percutaneous cochlear implantation technique: a cadaveric study

    by Ramya Balachandran, Jason E. Mitchell, Jack Noble, Daniel Schurzig, Grégoire Blachon, Theodore R. McRackan, Robert J. Webster, Benoit M. Dawant, J. Michael Fitzpatrick, Robert F. Labadie

    Cochlear implantation is a surgical procedure for treating patients with hearing loss in which an electrode array is inserted into the cochlea. The traditional surgical approach requires drilling away a large portion of the bone behind the ear to provide anatomical reference and access to the cochlea. A minimally-invasive technique, called percutaneous cochlear implantation (PCI), has been proposed that involves drilling a linear path from the lateral skull to the cochlea avoiding vital structures and inserting the implant using that drilled path. The steps required to achieve PCI safely include: placing three bone-implanted markers surrounding the ear, obtaining a CT scan, planning a surgical path to the cochlea avoiding vital anatomy, designing and constructing a microstereotactic frame that mounts on the markers and constrains the drill to the planned path, affixing the frame on the markers, using it to drill to the cochlea, and inserting the electrode through the drilled path. We present in this paper a cadaveric study demonstrating the PCI technique on three temporal bone cadaveric specimens for inserting electrode array into the cochlea. A custom fixture, called a Microtable, which is a type of microstereotactic frame that can be constructed in less than five minutes, was fabricated for each specimen and used to reach the cochlea. The insertion was successfully performed on all three specimens. Postinsertion CT scans confirm the correct placement of the electrodes inside the cochlea without any damage to the facial nerve.


  • Robotic Mastoidectomy

    by Andrei Danilchenko, Ramya Balachandran, Jenna L. Toennies, Stephan Baron, Benjamin Munske, J. Michael Fitzpatrick, Thomas J. Withrow, Robert J. Iii Webster, Robert F. Labadie

    Hypothesis: Using image-guided surgical techniques, we propose that an industrial robot can be programmed to safely, effectively, and efficiently perform a mastoidectomy. Background: Whereas robotics is a mature field in many surgical applications, robots have yet to be clinically used in otologic surgery despite significant advantages including reliability and precision. Methods: We designed a robotic system that incorporates custom software with an industrial robot to manipulate a surgical drill through a complex milling profile. The software controls the movements of the robot based on real-time feedback from a commercially available optical tracking system. The desired path of the drill to remove the desired volume of mastoid bone was planned using computed tomographic scans of cadaveric specimens and then implemented using the robotic system. Bone-implanted fiducial markers were used to provide accurate registration between computed tomographic and physical space. Results: A mastoid cavity was milled on 3 cadaveric specimens with a 5-mm fluted ball bit. Postmilling computed tomographic scans showed that, for the 3 specimens, 97.70%, 99.99%, and 96.05% of the target region was ablated without violation of any critical feature. Conclusion: To the best of our knowledge, this is the first time that a robot has been used to perform a mastoidectomy. Although significant hurdles remain to translate this technology to clinical use, we have shown that it is feasible. The prospect of reducing surgical time and enhancing patient safety by replacing human hand-eye coordination with machine precision motivates future work toward translating this technique to clinical use.