    Image-Guided Systems in Temporal Bone and Skull Base Surgery

    by Robert F. Labadie, J. Michael Fitzpatrick

    Image guidance is a part of the cutting edge of otologic and neurotologic surgery. The critical structures within the temporal bone generally have conserved and measurable relationships with the surrounding bone, which allows imaging to create accurate anatomical estimates that can be followed by a surgeon, human, or robot. As a relatively new area of temporal bone and skull base surgery, this field is filled with concepts and companies seeking adaptation, creating multiple, critical considerations for surgeons and scientists, which are discussed in this chapter.

  • A Compact, Bone-Attached Robot for Mastoidectomy

    by Neal P. Dillon, Ramya Balachandran, J. Michael Fitzpatrick, Michael A. Siebold, Robert F. Labadie, George B. Wanna, Thomas J. Withrow, Robert J. Webster

    Otologic surgery often involves a mastoidectomy, which is the removal of a portion of the mastoid region of the temporal bone, to safely access the middle and inner ear. The surgery is challenging because many critical structures are embedded within the bone, making them difficult to see and requiring a high level of accuracy with the surgical dissection instrument, a high-speed drill. We propose to automate the mastoidectomy portion of the surgery using a compact, bone-attached robot. The system described in this paper is a milling robot with four degrees-of-freedom (DOF) that is fixed to the patient during surgery using a rigid positioning frame screwed into the surface of the bone. The target volume to be removed is manually identified by the surgeon pre-operatively in a computed tomography (CT) scan and converted to a milling path for the robot. The surgeon attaches the robot to the patient in the operating room and monitors the procedure. Several design considerations are discussed in the paper as well as the proposed surgical workflow. The mean targeting error of the system in free space was measured to be 0.5 mm or less at vital structures. Four mastoidectomies were then performed in cadaveric temporal bones, and the error at the edges of the target volume was measured by registering a postoperative computed tomography (CT) to the pre-operative CT. The mean error along the border of the milled cavity was 0.38 mm, and all critical anatomical structures were preserved.


  • Evaluation of portable CT scanners for otologic image-guided surgery

    by Ramya Balachandran, Daniel Schurzig, J. Michael Fitzpatrick, Robert F. Labadie

    Purpose Portable CT scanners are beneficial for diagnosis in the intensive care unit, emergency room, and operating room. Portable fixed-base versus translating-base CT systems were evaluated for otologic image-guided surgical (IGS) applications based on geometric accuracy and utility for percutaneous cochlear implantation. Methods Five cadaveric skulls were fitted with fiducial markers and scanned using both a translating-base, 8-slice CT scanner (CereTom®) and a fixed-base, flat-panel, volume CT (fpVCT) scanner (Xoran xCAT®). Images were analyzed for: (a) subjective quality (i.e., noise), (b) consistency of attenuation measurements (Hounsfield units) across similar tissue, and (c) geometric accuracy of fiducial marker positions. The utility of these scanners in clinical IGS cases was tested. Results Five cadaveric specimens were scanned using each of the scanners. The translating-base, 8-slice CT scanner had spatially consistent Hounsfield units, and the image quality was subjectively good. However, because of movement variations during scanning, the geometric accuracy of fiducial marker positions was low. The fixed-base, fpVCT system had high spatial resolution, but the images were noisy and had spatially inconsistent attenuation measurements, while the geometric representation of the fiducial markers was highly accurate. Conclusion Two types of portable CT scanners were evaluated for otologic IGS. The translating-base, 8-slice CT scanner provided better image quality than a fixed-base, fpVCT scanner. However, the inherent error in three-dimensional spatial relationships by the translating-based system makes it suboptimal for otologic IGS use.


  • Insertion of electrode array using percutaneous cochlear implantation technique: a cadaveric study

    by Ramya Balachandran, Jason E. Mitchell, Jack Noble, Daniel Schurzig, Grégoire Blachon, Theodore R. McRackan, Robert J. Webster, Benoit M. Dawant, J. Michael Fitzpatrick, Robert F. Labadie

    Cochlear implantation is a surgical procedure for treating patients with hearing loss in which an electrode array is inserted into the cochlea. The traditional surgical approach requires drilling away a large portion of the bone behind the ear to provide anatomical reference and access to the cochlea. A minimally-invasive technique, called percutaneous cochlear implantation (PCI), has been proposed that involves drilling a linear path from the lateral skull to the cochlea avoiding vital structures and inserting the implant using that drilled path. The steps required to achieve PCI safely include: placing three bone-implanted markers surrounding the ear, obtaining a CT scan, planning a surgical path to the cochlea avoiding vital anatomy, designing and constructing a microstereotactic frame that mounts on the markers and constrains the drill to the planned path, affixing the frame on the markers, using it to drill to the cochlea, and inserting the electrode through the drilled path. We present in this paper a cadaveric study demonstrating the PCI technique on three temporal bone cadaveric specimens for inserting electrode array into the cochlea. A custom fixture, called a Microtable, which is a type of microstereotactic frame that can be constructed in less than five minutes, was fabricated for each specimen and used to reach the cochlea. The insertion was successfully performed on all three specimens. Postinsertion CT scans confirm the correct placement of the electrodes inside the cochlea without any damage to the facial nerve.


  • General Approach to First-Order Error Prediction in Rigid Point Registration

    by Andrei Danilchenko, J. Michael Fitzpatrick

    A general approach to the first-order analysis of error in rigid point registration is presented that accommodates fiducial localization error (FLE) that may be inhomogeneous (varying from point to point) and anisotropic (varying with direction) and also accommodates arbitrary weighting that may also be inhomogeneous and anisotropic. Covariances are derived for target registration error (TRE) and for weighted fiducial registration error (FRE) in terms of covariances of FLE, culminating in a simple implementation that encompasses all combinations of weightings and anisotropy. Furthermore, it is shown that for ideal weighting, in which the weighting matrix for each fiducial equals the inverse of the square root of the cross covariance of its two-space FLE, fluctuations of FRE and TRE are mutually independent. These results are validated by comparison with previously published expressions and by simulation. Furthermore, simulations for randomly generated fiducial positions and FLEs are presented that show that correlation is negligible in the exact case for both ideal and uniform weighting (i.e., no weighting), the latter of which is employed in commercial surgical guidance systems. From these results we conclude that for these weighting schemes, while valid expressions exist relating the covariance of FRE to the covariance of TRE, there are no measures of the goodness of fit of the fiducials for a given registration that give to first order any information about the fluctuation of TRE from its expected value and none that give useful information in the exact case. Therefore, as estimators of registration accuracy, such measures should be approached with extreme caution both by the purveyors of guidance systems and by the practitioners who use them.


  • Clinical Validation Study of Percutaneous Cochlear Access Using Patient-Customized Microstereotactic Frames

    by Robert F. Labadie, Ramya Balachandran, Jason E. Mitchell, Jack H. Noble, Omid Majdani, David S. Haynes, Marc L. Bennett, Benoit M. Dawant, J. Michael Fitzpatrick

    Objective: Percutaneous cochlear implant (PCI) surgery consists of drilling a single trough from the lateral cranium to the cochlea avoiding vital anatomy. To accomplish PCI, we use a patient-customized microstereotactic frame, which we call a "microtable" because it consists of a small tabletop sitting on legs. The orientation of the legs controls the alignment of the tabletop such that it is perpendicular to a specified trajectory. Study Design: Prospective. Setting: Tertiary referral center. Patients: Thirteen patients (18 ears) undergoing traditional cochlear implant surgery. Interventions: With institutional review board approval, each patient had 3 fiducial markers implanted in bone surrounding the ear. Temporal bone computed tomographic scans were obtained, and the markers were localized, as was vital anatomy. A linear trajectory from the lateral cranium through the facial recess to the cochlea was planned. A microtable was fabricated to follow the specified trajectory. Main Outcome Measures: After mastoidectomy and posterior tympanotomy, accuracy of trajectories was validated by mounting the microtables on the bone-implanted markers and then passing sham drill bits across the facial recess to the cochlea. The distance from the drill to vital anatomy was measured. Results: Microtables were constructed on a computer-numeric-control milling machine in less than 5 minutes each. Successful access across the facial recess to the cochlea was achieved in all 18 cases. The mean ± SD distance was 1.20 ± 0.36 mm from midportion of the drill to the facial nerve and 1.25 ± 0.33 mm from the chorda tympani. Conclusion: These results demonstrate the feasibility of PCI access using customized microstereotactic frames.


  • The role of registration in accurate surgical guidance

    by J M Fitzpatrick

    Registration is presented as the central issue of surgical guidance. The focus is on the accuracy of approaches employed today, all of which use pre-operative images to guide surgery on rigid anatomy. The three most well-established approaches to guidance, namely the stereotactic frame, point fiducials, and surface matching, are examined in detail, together with two new approaches based on microstereotactic frames. It is shown that each method relies on the registration of points in the image to corresponding points in the operating room, and therefore that the error patterns associated with point registration are similar for all of them. Three types of registration error, namely fiducial localization error (FLE), fiducial registration error (FRE), and target registration error (TRE), are highlighted, as well as two additional guidance errors, namely target localization error and total targeting error, the latter of which is the overall error of the guidance system. Statistical relationships between TRE and FLE, between FRE and FLE, and between TRE, TLE, and TTE are given. Finally some myths concerning fiducial registration are highlighted.


  • Percutaneous cochlear implant drilling via customized frames

    by Ramya Balachandran, Omid Majdani, Jack Noble, Jason Mitchell, Benoit M. Dawant, J. Michael Fitzpatrick, Robert Labadie


  • Customized, rapid-production microstereotactic table for surgical targeting: description of concept and in vitro validation

    by Robert F. Labadie, Jason Mitchell, Ramya Balachandran, J. Michael Fitzpatrick

    Purpose To introduce a novel microstereotactic frame, called the Microtable, consisting of a tabletop that mounts on bone-implanted spherical markers. The microtable is customized for individual patient anatomy to guide a surgical instrument to a specified target. Methods Fiducial markers are bone-implanted, and CT scanning is performed. A microtable is custom-designed for the location of the markers and the desired surgical trajectory and is constructed using a computer-numerical-control machine. Validation studies were performed on phantoms with geometry similar to that for cochlear implant surgery. Two designs were tested with two different types of fiducial markers. Results Mean targeting error of the microtables for the two designs were 0.37 ± 0.18 and 0.60 ± 0.21 mm (n = 5). Construction of each microtable required approximately 6 min. Conclusions The new frame achieves both high accuracy and rapid fabrication. We are currently using the microtable for clinical testing of the concept of percutaneous cochlear implant surgery.


  • Accuracy of Image-Guided Surgical Systems at the Lateral Skull Base as Clinically Assessed Using Bone-Anchored Hearing Aid Posts as Surgical Targets

    by Ramya Balachandran, J. Michael Fitzpatrick, Robert F. Labadie

    Objective: Image-guided surgical (IGS) technology has been clinically available for more than a decade. To date, no acceptable standard exists for reporting the accuracy of IGS systems, especially for lateral skull base applications. We present a validation method that uses the post from bone-anchored hearing aid (BAHA) patients as a target. We then compare the accuracy of 2 IGS systems-one using laser skin-surface scanning (LSSS) and another using a noninvasive fiducial frame (FF) attached to patient via dental bite-block (DBB) for registration. Study Design: Prospective. Setting: Tertiary referral center. Patients: Six BAHA patients who had adequate dentition for creation of a DBB. Intervention(s): For each patient, a dental impression was obtained, and a customized DBB was made to hold an FF. Temporal bone computed tomographic (CT) scans were obtained with the patient wearing the DBB, FF, and a customized marker on the BAHA post. In a mock operating room, CT scans were registered to operative anatomy using 2 methods: 1) LSSS and 2) FF. Main Outcome Measure(s): For each patient and each system, the position of the BAHA marker in the CT scan and in the mock operating room (using optical measurement technology) was compared, and the distances between them are reported to demonstrate accuracy. Results: Accuracy (mean ± standard deviation) was 1.54 ± 0.63 mm for DBB registration and 3.21 ± 1.02 mm for LSSS registration. Conclusion: An IGS system using FF registration is more accurate than one using LSSS (p = 0.03, 2-sided Student's t test). BAHA patients provide a unique patient population upon which IGS systems may be validated.