Robert H. Hopper
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Robert H. Hopper has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- C. Anderson Engh
Anderson Orthopaedic Research Institute, Alexandria, Virginia
3 shared publications Henry Ho
Adult Hip and Knee Replacement, Anderson Orthopaedic Research Institute, Alexandria, USA
2 shared publicationsAlexander V. Strait
Adult Hip and Knee Replacement, Anderson Orthopaedic Research Institute, Alexandria, USA
1 shared publicationAnderson C. Engh
1 shared publicationCara C. Powers
Anderson Orthopaedic Research Institute
1 shared publicationCharles A Engh
1 shared publication
Latest Publications
- Open Access
- 27 November 2024
- Published by Springer Nature in Cureus
- Vol. 16 (11)
Early Outcome of a Contemporary Unicondylar Knee System
Introduction: In 2019, a new fixed-bearing implant for unicondylar knee arthroplasty (UKA) was introduced that incorporated a round-on-flat design featuring an Oxinium femoral component coupled with a highly crosslinked polyethylene bearing surface. Compared to prior implants, the design featured smaller size increments coupled with medial and lateral-specific tibial baseplates. The objective of this study is to describe our institution’s early experience with this UKA implant system by evaluating survivorship, reasons for revision, and patient-reported outcome measures (PROMs). Methods: The 944 UKAs that comprise the study population, including 814 medial and 130 lateral joint replacements, were performed by six surgeons from September 2019 through the end of December 2023. All UKA components were cemented, the mean age at surgery was 67.1±10.0 years, 57% (537/944) of the UKAs were performed among women, and the mean body mass index was 30.3±6.2 kg/m2. Outcome measures included Kaplan-Meier survivorship using reoperation for any reason as an endpoint, reasons for reoperation, range of motion, and PROMs that were collected preoperatively and postoperatively at 4 weeks, 4 months, 1 year, and 2 years. Results: Using reoperation for any reason as an endpoint, 1-year survivorship was 99.3% (95% CI, 98.7 to 99.9%) and 2-year survivorship was 98.2% (95% CI, 96.9 to 99.5%). There were nine reoperations among the 944 UKAs, including three for infection, two for tibial loosening, one for femoral loosening, one for progression of arthritis, one for patellar instability, and one for recurrent hemarthrosis. The mean time to reoperation was 0.82±0.68 years and all were performed among medial UKAs. Range of motion increased from 117±8 degrees preoperatively to 122±6 degrees at 1-year follow-up. PROMs, including the Knee Injury and Osteoarthritis Outcome Score for Joint Replacement (KOOS JR) and the Patient-Reported Outcomes Measurement Information System (PROMIS) Global Health Physical score, demonstrated progressive increases from the preoperative assessment through 2-year follow-up. For UKAs with preoperative and 2-year KOOS JR scores, the mean change was 31±17. Conclusion: As new implants and technologies are introduced, documenting the early outcome from high volume centers can offer valuable insights to validate the effectiveness of implant systems before they are adopted by the broader orthopedic community. This study demonstrates encouraging early outcome data associated with a contemporary UKA system based on survivorship and PROMs. At this early stage, there are no implant-related concerns but obtaining additional follow-up will be important to quantify how revisions and PROMs evolve over time.
- 27 November 2024
- Published by Springer Nature in Cureus
- Vol. 16 (11)
Open AccessEarly Outcome of a Contemporary Unicondylar Knee System
Introduction: In 2019, a new fixed-bearing implant for unicondylar knee arthroplasty (UKA) was introduced that incorporated a round-on-flat design featuring an Oxinium femoral component coupled with a highly crosslinked polyethylene bearing surface. Compared to prior implants, the design featured smaller size increments coupled with medial and lateral-specific tibial baseplates. The objective of this study is to describe our institution’s early experience with this UKA implant system by evaluating survivorship, reasons for revision, and patient-reported outcome measures (PROMs). Methods: The 944 UKAs that comprise the study population, including 814 medial and 130 lateral joint replacements, were performed by six surgeons from September 2019 through the end of December 2023. All UKA components were cemented, the mean age at surgery was 67.1±10.0 years, 57% (537/944) of the UKAs were performed among women, and the mean body mass index was 30.3±6.2 kg/m2. Outcome measures included Kaplan-Meier survivorship using reoperation for any reason as an endpoint, reasons for reoperation, range of motion, and PROMs that were collected preoperatively and postoperatively at 4 weeks, 4 months, 1 year, and 2 years. Results: Using reoperation for any reason as an endpoint, 1-year survivorship was 99.3% (95% CI, 98.7 to 99.9%) and 2-year survivorship was 98.2% (95% CI, 96.9 to 99.5%). There were nine reoperations among the 944 UKAs, including three for infection, two for tibial loosening, one for femoral loosening, one for progression of arthritis, one for patellar instability, and one for recurrent hemarthrosis. The mean time to reoperation was 0.82±0.68 years and all were performed among medial UKAs. Range of motion increased from 117±8 degrees preoperatively to 122±6 degrees at 1-year follow-up. PROMs, including the Knee Injury and Osteoarthritis Outcome Score for Joint Replacement (KOOS JR) and the Patient-Reported Outcomes Measurement Information System (PROMIS) Global Health Physical score, demonstrated progressive increases from the preoperative assessment through 2-year follow-up. For UKAs with preoperative and 2-year KOOS JR scores, the mean change was 31±17. Conclusion: As new implants and technologies are introduced, documenting the early outcome from high volume centers can offer valuable insights to validate the effectiveness of implant systems before they are adopted by the broader orthopedic community. This study demonstrates encouraging early outcome data associated with a contemporary UKA system based on survivorship and PROMs. At this early stage, there are no implant-related concerns but obtaining additional follow-up will be important to quantify how revisions and PROMs evolve over time.
- 30 August 2018
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 477 (1) , 91-94
CORR Insights®: Radiostereometric Analysis Permits In Vivo Measurement of Very Small Levels of Wear in TKA
- 30 August 2018
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 477 (1) , 91-94
CORR Insights®: Radiostereometric Analysis Permits In Vivo Measurement of Very Small Levels of Wear in TKA
- 10 August 2012
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 471 (1) , 86-93
Can Microcomputed Tomography Measure Retrieved Polyethylene Wear? Comparing Fixed-bearing and Rotating-platform Knees
Wear of total knee polyethylene has been quantified gravimetrically with thickness measurements and evaluation of surface wear modes. However, these techniques do not localize volumetric wear.
- 10 August 2012
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 471 (1) , 86-93
Can Microcomputed Tomography Measure Retrieved Polyethylene Wear? Comparing Fixed-bearing and Rotating-platform Knees
Wear of total knee polyethylene has been quantified gravimetrically with thickness measurements and evaluation of surface wear modes. However, these techniques do not localize volumetric wear.
- Open Access
- 1 February 2012
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 470 (2) , 462-470
The Effect of Poly Sterilization on Wear, Osteolysis and Survivorship of a Press-fit Cup at 10-Year Followup
During the mid-1990s when our institution was using a press-fit porous-coated cup without supplemental initial fixation for primary THA, the manufacturer transitioned from gamma irradiation to gas plasma for the terminal sterilization of their polyethylene liners. At minimum 10-year followup, we asked whether the fixation achieved by solely relying on a press-fit would be durable and how different liner sterilization methods affected radiographic wear, osteolysis, and survivorship. We retrospectively reviewed 373 patients who underwent 398 primary THAs with a press-fit porous-coated cup between March 1995 and December 1996. Mean age at time of surgery was 61.5 ± 13.3 years and mean followup was 10.4 ± 3.7 years. We determined reasons for revision, survivorship, femoral head penetration, osteolysis, and wear-related complications. Among 20 revisions involving any component, seven were associated with wear and osteolysis. Kaplan-Meier survivorship, using component revision for any reason as an end point, was 95.7% (95% confidence interval, 93.6%–97.9%) at 10 years. Noncrosslinked liners sterilized with gas plasma demonstrated a mean head penetration rate of 0.20 ± 0.09 mm/year compared with 0.13 ± 0.07 mm/year for liners sterilized with gamma irradiation in air and 0.09 ± 0.04 mm/year for liners sterilized with gamma-irradiation with barrier packaging without oxygen. THAs with increased volumetric wear tended to demonstrate larger osteolytic lesions (r = 0.40) and there tended to be less osteolysis among the liners sterilized with gamma-irradiation with barrier packaging without oxygen. However, there was no difference in survivorship among the sterilization groups and there has been no cup or stem loosening associated with osteolysis. Durable biologic fixation through 10-year followup can be achieved by solely relying on an initial press-fit. Noncrosslinking gas plasma for terminal sterilization of the polyethylene liners was associated with greater head penetration rate than gamma irradiation. Level IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.
- 1 February 2012
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 470 (2) , 462-470
Open AccessThe Effect of Poly Sterilization on Wear, Osteolysis and Survivorship of a Press-fit Cup at 10-Year Followup
During the mid-1990s when our institution was using a press-fit porous-coated cup without supplemental initial fixation for primary THA, the manufacturer transitioned from gamma irradiation to gas plasma for the terminal sterilization of their polyethylene liners. At minimum 10-year followup, we asked whether the fixation achieved by solely relying on a press-fit would be durable and how different liner sterilization methods affected radiographic wear, osteolysis, and survivorship. We retrospectively reviewed 373 patients who underwent 398 primary THAs with a press-fit porous-coated cup between March 1995 and December 1996. Mean age at time of surgery was 61.5 ± 13.3 years and mean followup was 10.4 ± 3.7 years. We determined reasons for revision, survivorship, femoral head penetration, osteolysis, and wear-related complications. Among 20 revisions involving any component, seven were associated with wear and osteolysis. Kaplan-Meier survivorship, using component revision for any reason as an end point, was 95.7% (95% confidence interval, 93.6%–97.9%) at 10 years. Noncrosslinked liners sterilized with gas plasma demonstrated a mean head penetration rate of 0.20 ± 0.09 mm/year compared with 0.13 ± 0.07 mm/year for liners sterilized with gamma irradiation in air and 0.09 ± 0.04 mm/year for liners sterilized with gamma-irradiation with barrier packaging without oxygen. THAs with increased volumetric wear tended to demonstrate larger osteolytic lesions (r = 0.40) and there tended to be less osteolysis among the liners sterilized with gamma-irradiation with barrier packaging without oxygen. However, there was no difference in survivorship among the sterilization groups and there has been no cup or stem loosening associated with osteolysis. Durable biologic fixation through 10-year followup can be achieved by solely relying on an initial press-fit. Noncrosslinking gas plasma for terminal sterilization of the polyethylene liners was associated with greater head penetration rate than gamma irradiation. Level IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.
- 1 December 2004
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 429 (429) , 54-62
The Pros and Cons of Polyethylene Sterilization with Gamma Irradiation
This retrospective study evaluated the implant, patient and surgical factors associated with polyethylene wear for one type of porous-coated hemispheric total hip arthroplasty cup. Radiographic wear measurements among 567 Duraloc cups (512 patients) revealed that liners sterilized by gamma-irradiation wore 0.085 mm/year less than those that were sterilized by gas-plasma, a noncross-linking chemical surface treatment. The substantially decreased wear rate associated with gamma-irradiation was attributed to sterilization-induced polyethylene cross-linking. Shelf-aging adversely affected liners that were gamma irradiated in air. On average, highly crystalline Hylamer liners showed a 0.064 mm/year increase in wear rates for each year of shelf storage after terminal sterilization with gamma-irradiation in air. Among conventional Enduron liners, the effect of shelf aging after gamma-irradiation in air was more modest, increasing wear rates by 0.014 mm/year for each year of shelf storage. Because Hylamer’s wear performance degraded at about five times the rate of Enduron’s, the improved wear resistance associated with gamma-irradiation in air would be lost after 1.3 years of shelf aging for Hylamer compared with 6.1 years for Enduron. For every additional year of age at the time of surgery, the wear rate decreased by 0.003 mm/year. Increased body mass index, a preoperative diagnosis of inflammatory arthritis, and a ceramic femoral head also were associated with decreased wear rates.
- 1 December 2004
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 429 (429) , 54-62
The Pros and Cons of Polyethylene Sterilization with Gamma Irradiation
This retrospective study evaluated the implant, patient and surgical factors associated with polyethylene wear for one type of porous-coated hemispheric total hip arthroplasty cup. Radiographic wear measurements among 567 Duraloc cups (512 patients) revealed that liners sterilized by gamma-irradiation wore 0.085 mm/year less than those that were sterilized by gas-plasma, a noncross-linking chemical surface treatment. The substantially decreased wear rate associated with gamma-irradiation was attributed to sterilization-induced polyethylene cross-linking. Shelf-aging adversely affected liners that were gamma irradiated in air. On average, highly crystalline Hylamer liners showed a 0.064 mm/year increase in wear rates for each year of shelf storage after terminal sterilization with gamma-irradiation in air. Among conventional Enduron liners, the effect of shelf aging after gamma-irradiation in air was more modest, increasing wear rates by 0.014 mm/year for each year of shelf storage. Because Hylamer’s wear performance degraded at about five times the rate of Enduron’s, the improved wear resistance associated with gamma-irradiation in air would be lost after 1.3 years of shelf aging for Hylamer compared with 6.1 years for Enduron. For every additional year of age at the time of surgery, the wear rate decreased by 0.003 mm/year. Increased body mass index, a preoperative diagnosis of inflammatory arthritis, and a ceramic femoral head also were associated with decreased wear rates.
- 1 June 2002
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 17 (4) , 102-107
The odyssey of porous-coated fixation
- 1 June 2002
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 17 (4) , 102-107
The odyssey of porous-coated fixation