Latest Publications

  • Hemorheological Approach to Improve Perfusion of Red Blood Cells with Reduced Deformability Using Drag-Reducing Polymer (In Vitro Study)

    by Dan Crompton, Shushma Gudla, Jonathan H. Waters, Prithu Sundd, Marina V. Kameneva

    Drag-reducing polymers (DRPs) are nontoxic water-soluble blood additives that have been shown to beneficially alter hemodynamics when delivered intravenously in nanomolar concentrations. This study examines the ability of DRPs to alter the traffic of mixtures of normal and less-deformable red blood cells (RBCs) through branched microchannels and is intended to support and expand upon previous experiments within straight capillary tubes to promote DRPs for future clinical use. Branched polydimethylsiloxane microchannels were perfused with a mixture of normal bovine RBCs also containing heat-treated less-deformable RBCs at a hematocrit of 30% with 10 ppm of the DRP poly(ethylene oxide) (MW 4M Da). Suspensions were driven by syringe pump, collected at outlets, and RBC dimensions measured while subject to shear stress to determine the proportion of healthy RBCs in each sample. DRPs eliminated evidence of the plasma skimming phenomena and significantly increased the pressure drop across microchannels. Further, DRPs were found to cause an increase in the proportion of healthy RBCs exiting the branch outlet from –8.5 ± 2.5% (control groups) to +12.1 ± 5.4% (n = 6, p = 0.02). These results suggest DRP additives may be used to improve the perfusion of less-deformable RBCs in vivo and indicates their potential for future clinical use.


  • Open Access

    Drag-reducing polymers improve hepatic vaso-occlusion in SCD mice

    by Dan Crompton, Ravi Vats, Tirthadipa Pradhan-Sundd, Prithu Sundd, Marina V. Kameneva

    Key Points: Nanomolar concentrations of drag-reducing polymer (DRP) reduce vaso-occlusion in the liver of sickle cell disease (SCD) mice. The potential for DRP as a rheology-based treatment/therapy for SCD warrants further study.


  • Open Access

    A Quasi-Mechanistic Mathematical Representation for Blood Viscosity

    by Samuel J. Hund, Marina V. Kameneva, James F. Antaki

    Blood viscosity is a crucial element for any computation of flow fields in the vasculature or blood-wetted devices. Although blood is comprised of multiple elements, and its viscosity can vary widely depending on several factors, in practical applications, it is commonly assumed to be a homogeneous, Newtonian fluid with a nominal viscosity typically of 3.5 cP. Two quasi-mechanistic models for viscosity are presented here, built on the foundation of the Krieger model of suspensions, in which dependencies on shear rate, hematocrit, and plasma protein concentrations are explicitly represented. A 3-parameter Asymptotic Krieger model (AKM) exhibited excellent agreement with published Couette experiments over four decades of shear rate (0–1000 s-1, root mean square (RMS) error = 0.21 cP). A 5-parameter Modified Krieger Model (MKM5) also demonstrated a very good fit to the data (RMS error = 1.74 cP). These models avoid discontinuities exhibited by previous models with respect to hematocrit and shear rate. In summary, the quasi-mechanistic, Modified-Krieger Model presented here offers a reasonable compromise in complexity to provide flexibility to account for several factors that affect viscosity in practical applications, while assuring accuracy and stability.


  • Red Blood Cell Mechanical Fragility Test for Clinical Research Applications

    by Luke A. Ziegler, Salim E. Olia, Marina V. Kameneva

    Red blood cell (RBC) susceptibility to mechanically induced hemolysis, or RBC mechanical fragility (MF), is an important parameter in the characterization of erythrocyte membrane health. The rocker bead test (RBT) and associated calculated mechanical fragility index (MFI) is a simple method for the assessment of RBC MF. Requiring a minimum of 15.5 mL of blood and necessitating adjustment of hematocrit (Ht) to a “standard” value (40%), the current RBT is not suitable for use in most studies involving human subjects. To address these limitations, we propose a 6.5 mL reduced volume RBT and corresponding modified MFI (MMFI) that does not require prior Ht adjustment. This new method was assessed for i) correlation to the existing text, ii) to quantify the effect of Ht on MFI, and iii) validation by reexamining the protective effect of plasma proteins on RBC MF. The reduced volume RBT strongly correlated (r = 0.941) with the established large volume RBT at matched Hts, and an equation was developed to calculate MMFI: a numerical estimation (R2 = 0.923) of MFI if performed with the reduced volume RBT at “standard” (40%) Ht. An inversely proportional relationship was found between plasma protein concentration and RBC MF using the MMFI‐reduced volume method, supporting previous literature findings. The new reduced volume RBT and modified MFI will allow for the measurement of RBC MF in clinical and preclinical studies involving humans or small animals.


  • Open Access

    Natural Drag-Reducing Polymers: Discovery, Characterization and Potential Clinical Applications

    by Joie N. Marhefka, Marina V. Kameneva

    About seven decades ago, it was discovered that special long-chain soluble polymers added to fluid at nanomolar concentrations significantly reduce resistance to turbulent flow (Toms effect). These so-called drag-reducing polymers (DRPs) do not affect resistance to laminar flow. While the flow parameters associated with the Toms effect do not occur in the cardiovascular system, many later studies demonstrated that intravenous injections of DRPs given to experimental animals produced significant hemodynamic effects, such as increasing tissue perfusion, suggesting potential clinical use of these polymers. Moreover, it was found that the specific viscoelastic properties of these polymers make them capable of modifying traffic of blood cells in microvessels and beneficially redistributing them in the blood capillary system—a phenomenon related to rheological properties of DRPs and not related to their specific chemistry. The domain of drag reducing polymers includes many organic and water-soluble, synthetic and natural long-chain molecules. The study presented here employed chemical and rheological methods, as well as macro and microfluidic tests, to characterize the DRP that we discovered in the Aloe vera plant, which was found to be a more powerful drag reducer and less fragile than many synthetic DRPs. The drag-reducing component of aloe gel was purified and chemically identified, which helped to standardize preparation and made this polymer a strong candidate for clinical use. Examples of successful testing of the aloe-derived DRP in animal models are described.


  • A Reusable, Compliant, Small Volume Blood Reservoir for In Vitro Hemolysis Testing

    by Salim E. Olia, Luke H. Herbertson, Richard A. Malinauskas, Marina V. Kameneva

    Bench‐top in vitro hemolysis testing is a fundamental tool during the design and regulatory safety evaluation of blood‐contacting medical devices. While multiple published experimental protocols exist, descriptions of the test loop reservoir remain ambiguous. A critical fixture within the circuit, there is no readily available blood reservoir that ensures thorough mixing and complete air evacuation: two major factors which can affect results. As part of the Food and Drug Administration (FDA) Critical Path Initiative, we developed a three‐piece reservoir consisting of a 3D‐printed base, a plastic clamp set, and a medical‐grade blood bag. This simple, reusable, and cost‐effective design was used successfully in the hemolysis assessment of FDA benchmark nozzles and prototype rotary blood pumps, and may be useful as an integral component to any in vitro blood circulation loop.


  • Open Access

    Mechanical Blood Trauma in Assisted Circulation: Sublethal RBC Damage Preceding Hemolysis

    by Salim E. Olia, Timothy M. Maul, James F. Antaki, Marina V. Kameneva

    After many decades of improvements in mechanical circulatory assist devices (CADs), blood damage remains a serious problem during support contributing to variety of adverse events, and consequently affecting patient survival and quality of life. The mechanisms of cumulative cell damage in continuous-flow blood pumps are still not fully understood despite numerous in vitro, in vivo , and in silico studies of blood trauma. Previous investigations have almost exclusively focused on lethal blood damage, namely hemolysis, which is typically negligible during normal operation of current generation CADs. The measurement of plasma free hemoglobin (plfHb) concentration to characterize hemolysis is straightforward, however sublethal trauma is more difficult to detect and quantify since no simple direct test exists. Similarly, while multiple studies have focused on thrombosis within blood pumps and accessories, sublethal blood trauma and its sequelae have yet to be adequately documented or characterized. This review summarizes the current understanding of sublethal trauma to red blood cells (RBCs) produced by exposure of blood to flow parameters and conditions similar to those within CADs. It also suggests potential strategies to reduce and/or prevent RBC sublethal damage in a clinically-relevant context, and encourages new research into this relatively uncharted territory.


  • Effect of blood bank storage on the rheological properties of male and female donor red blood cells

    by Amanda Daly, Jay S. Raval, Jonathan H. Waters, Mark H. Yazer, Marina V. Kameneva

    It was previously demonstrated that red blood cell (RBC) deformability progressively decreases during storage along with other changes in RBC mechanical properties. Recently, we reported that the magnitude of changes in RBC mechanical fragility assoc


  • PediaFlow™ Maglev Ventricular Assist Device: A Prescriptive Design Approach

    by James F. Antaki, Michael R. Ricci, Josiah E. Verkaik, Shaun T. Snyder, Timothy M. Maul, Jeongho Kim, Dave B. Paden, Marina V. Kameneva, Bradley E. Paden, Peter D. Wearden, et al.

    This report describes a multi-disciplinary program to develop a pediatric blood pump, motivated by the critical need to treat infants and young children with congenital and acquired heart diseases. The unique challenges of this patient population require a device with exceptional biocompatibility, miniaturized for implantation up to 6 months. This program implemented a collaborative, prescriptive design process, whereby mathematical models of the governing physics were coupled with numerical optimization to achieve a favorable compromise among several competing design objectives. Computational simulations of fluid dynamics, electromagnetics, and rotordynamics were performed in two stages: first using reduced-order formulations to permit rapid optimization of the key design parameters; followed by rigorous CFD and FEA simulations for calibration, validation, and detailed optimization. Over 20 design configurations were initially considered, leading to three pump topologies, judged on the basis of a multi-component analysis including criteria for anatomic fit, performance, biocompatibility, reliability, and manufacturability. This led to fabrication of a mixed-flow magnetically levitated pump, the PF3, having a displaced volume of 16.6 cc, approximating the size of a AA battery and producing a flow capacity of 0.3–1.5 L/min. Initial in vivo evaluation demonstrated excellent hemocompatibility after 72 days of implantation in an ovine. In summary, combination of prescriptive and heuristic design principles have proven effective in developing a miniature magnetically levitated blood pump with excellent performance and biocompatibility, suitable for integration into chronic circulatory support system for infants and young children; aiming for a clinical trial within 3 years.


  • Drag-reducing polymers diminish near-wall concentration of platelets in microchannel blood flow

    by R. Zhao, J.N. Marhefka, J.F. Antaki, M.V. Kameneva

    The accumulation of platelets near the blood vessel wall or artificial surface is an important factor in the cascade of events responsible for coagulation and/or thrombosis. In small blood vessels and flow channels this phenomenon has been attributed