Salim E. Olia
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Salim E. Olia has a total of 96 co-authors. Here are the top co-authors by number of shared publications:
Marina V. Kameneva
Department of Bioengineering, University of Pittsburgh, Pittsburgh, Pa; McGowan Institute for Regenerative Medicine, University of Pittsburgh, Pittsburgh, Pa; Department of Surgery, University of Pittsburgh, Pittsburgh, Pa
8 shared publicationsTimothy M. Maul
Department of Bioengineering, University of Pittsburgh, Pittsburgh, Pa; McGowan Institute for Regenerative Medicine, University of Pittsburgh, Pittsburgh, Pa; Children's Hospital of Pittsburgh, University of Pittsburgh Medical Center, Pittsburgh, Pa; Department of Cardiothoracic Surgery, University of Pittsburgh, Pittsburgh, Pa
5 shared publicationsErgin Kocyildirim
McGowan Institute for Regenerative Medicine, University of Pittsburgh, Pittsburgh, Pa; Children's Hospital of Pittsburgh, University of Pittsburgh Medical Center, Pittsburgh, Pa
4 shared publicationsHarvey S. Borovetz
Department of Bioengineering, University of Pittsburgh, Pittsburgh, Pa; McGowan Institute for Regenerative Medicine, University of Pittsburgh, Pittsburgh, Pa; Department of Surgery, University of Pittsburgh, Pittsburgh, Pa; Department of Chemical and Petroleum Engineering, University of Pittsburgh, Pittsburgh, Pa
4 shared publications- Marina V. Kameneva
Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA
4 shared publications - William R. Wagner
Department of Bioengineering University of Pittsburgh Pittsburgh Pennsylvania USA
4 shared publications
Latest Publications
- 11 September 2026
- Published by Wolters Kluwer Health in ASAIO Journal
Extracorporeal Membrane Oxygenation Combined With Embolectomy May Yield Better Outcomes Than Extracorporeal Membrane Oxygenation Alone or With Thrombolysis for Acute High-Risk Pulmonary Embolism
Veno-arterial extracorporeal membrane oxygenation (ECMO) is used to support patients with high-risk pulmonary embolism (HR-PE) with cardiogenic shock, but data on mid- and long-term outcomes after reperfusion remain limited. We retrospectively compared outcomes after ECMO with embolectomy, ECMO with thrombolysis, or ECMO alone in patients with HR-PE supported at a tertiary-care hospital (2016–2024). Extracorporeal membrane oxygenation was used in 72 patients with HR-PE; 22 received ECMO with embolectomy, 28 received ECMO with thrombolysis, and 22 received ECMO alone. The median duration of ECMO support was 5 days (interquartile range: 4–6 days). In-hospital complications and support time did not differ significantly between groups. Weaning from ECMO was achieved significantly more often with embolectomy (n = 22, 100%) than with thrombolysis (n = 17, 60.7%) or ECMO alone (n = 8, 36.4%) ( p < 0.01). Survival to hospital discharge was highest after ECMO with embolectomy (n = 18, 81.8%), as compared with ECMO with thrombolysis (n = 16, 57.1%) or ECMO alone (n = 4, 18.1%) ( p < 0.01). One and 3 year survival was 81.8% and 72.7% after ECMO with embolectomy, 55.7% and 46.4% after ECMO with thrombolysis, and 18.2% and 18.2% after ECMO alone ( p < 0.001). Extracorporeal membrane oxygenation with early percutaneous or surgical embolectomy may provide a survival benefit over ECMO alone in patients with HR-PE. Further prospective studies are warranted.
- 11 September 2026
- Published by Wolters Kluwer Health in ASAIO Journal
Extracorporeal Membrane Oxygenation Combined With Embolectomy May Yield Better Outcomes Than Extracorporeal Membrane Oxygenation Alone or With Thrombolysis for Acute High-Risk Pulmonary Embolism
Veno-arterial extracorporeal membrane oxygenation (ECMO) is used to support patients with high-risk pulmonary embolism (HR-PE) with cardiogenic shock, but data on mid- and long-term outcomes after reperfusion remain limited. We retrospectively compared outcomes after ECMO with embolectomy, ECMO with thrombolysis, or ECMO alone in patients with HR-PE supported at a tertiary-care hospital (2016–2024). Extracorporeal membrane oxygenation was used in 72 patients with HR-PE; 22 received ECMO with embolectomy, 28 received ECMO with thrombolysis, and 22 received ECMO alone. The median duration of ECMO support was 5 days (interquartile range: 4–6 days). In-hospital complications and support time did not differ significantly between groups. Weaning from ECMO was achieved significantly more often with embolectomy (n = 22, 100%) than with thrombolysis (n = 17, 60.7%) or ECMO alone (n = 8, 36.4%) ( p < 0.01). Survival to hospital discharge was highest after ECMO with embolectomy (n = 18, 81.8%), as compared with ECMO with thrombolysis (n = 16, 57.1%) or ECMO alone (n = 4, 18.1%) ( p < 0.01). One and 3 year survival was 81.8% and 72.7% after ECMO with embolectomy, 55.7% and 46.4% after ECMO with thrombolysis, and 18.2% and 18.2% after ECMO alone ( p < 0.001). Extracorporeal membrane oxygenation with early percutaneous or surgical embolectomy may provide a survival benefit over ECMO alone in patients with HR-PE. Further prospective studies are warranted.
- 24 July 2026
- Published by Wolters Kluwer Health in ASAIO Journal
Outcomes of Temporary Right Ventricular Assist Device at the Time of Durable Left Ventricular Assist Device Implantation
Patients requiring a right ventricular assist device (RVAD) after durable left ventricular assist device (LVAD) surgery have historically worse outcomes than those with isolated LVADs. Preoperative mechanical circulatory support (MCS) with venoarterial extracorporeal membrane oxygenation (ECMO) or micro-axial pumps complicates right heart assessment by altering loading conditions. We examined 1 year outcomes of patients receiving temporary RVADs at the time of durable LVAD. From February 2017 to August 2025, 102 patients were reviewed. Right ventricular assist device decannulation, ventilator liberation, and intensive care unit (ICU) discharge were assessed using Fine–Gray subdistribution analysis with death as a competing risk; 1 year survival was evaluated by Kaplan–Meier analysis. Analysis included 59 planned, 28 unplanned, and 15 delayed RVADs (45 percutaneous, 57 surgical). One year survival was 64.0 ± 6.5% for planned, 50.2 ± 10.3% for unplanned, and 50.3 ± 13.6% for delayed RVAD. Percutaneous and surgical RVAD survival were 60.1 ± 7.5% and 55.1 ± 7.1%. Preoperative MCS was independently associated with improved survival (hazard ratio [HR]: 0.36, confidence interval [CI]: 0.17–0.83), with micro-axial pump showing the strongest association. Preoperative micro-axial support and planned RVAD were associated with improved 1 year survival after durable LVAD surgery; whether this reflects a causal relationship where the preconditioning of the right ventricle improves postoperative outcomes cannot be determined from this retrospective design.
- 24 July 2026
- Published by Wolters Kluwer Health in ASAIO Journal
Outcomes of Temporary Right Ventricular Assist Device at the Time of Durable Left Ventricular Assist Device Implantation
Patients requiring a right ventricular assist device (RVAD) after durable left ventricular assist device (LVAD) surgery have historically worse outcomes than those with isolated LVADs. Preoperative mechanical circulatory support (MCS) with venoarterial extracorporeal membrane oxygenation (ECMO) or micro-axial pumps complicates right heart assessment by altering loading conditions. We examined 1 year outcomes of patients receiving temporary RVADs at the time of durable LVAD. From February 2017 to August 2025, 102 patients were reviewed. Right ventricular assist device decannulation, ventilator liberation, and intensive care unit (ICU) discharge were assessed using Fine–Gray subdistribution analysis with death as a competing risk; 1 year survival was evaluated by Kaplan–Meier analysis. Analysis included 59 planned, 28 unplanned, and 15 delayed RVADs (45 percutaneous, 57 surgical). One year survival was 64.0 ± 6.5% for planned, 50.2 ± 10.3% for unplanned, and 50.3 ± 13.6% for delayed RVAD. Percutaneous and surgical RVAD survival were 60.1 ± 7.5% and 55.1 ± 7.1%. Preoperative MCS was independently associated with improved survival (hazard ratio [HR]: 0.36, confidence interval [CI]: 0.17–0.83), with micro-axial pump showing the strongest association. Preoperative micro-axial support and planned RVAD were associated with improved 1 year survival after durable LVAD surgery; whether this reflects a causal relationship where the preconditioning of the right ventricle improves postoperative outcomes cannot be determined from this retrospective design.
- 6 March 2024
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 70 (9) , 758-766
Percutaneous Venopulmonary Extracorporeal Membrane Oxygenation as Bridge to Lung Transplantation
Mechanical circulatory support (MCS) as a bridge to lung transplant is an infrequent but accepted pathway in patients who have refractory end-stage pulmonary failure. The American Association of Thoracic Surgeons Expert Consensus Guidelines, published in 2023, recommends venovenous (VV) extracorporeal membrane oxygenation (ECMO) as the initial configuration for those patients who have failed conventional medical therapy, including mechanical ventilation, while waiting for lung transplantation and needing MCS. Alternatively, venoarterial (VA) ECMO can be used in patients with acute right ventricular failure, hemodynamic instability, or refractory respiratory failure. With the advancement in percutaneous venopulmonary (VP) ECMO cannulation techniques, this option is becoming an attractive configuration as bridge to lung transplantation. This configuration enhances stability of the right ventricle, prevents recirculation with direct introduction of pulmonary artery oxygenation, and promotes hemodynamic stability during mobility, rehabilitation, and sedation-weaning trials before lung transplantation. Here, we present a case series of eight percutaneous VP ECMO as bridge to lung transplant with all patients mobilized, awake, and successfully transplanted with survival to hospital discharge.
- 6 March 2024
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 70 (9) , 758-766
Percutaneous Venopulmonary Extracorporeal Membrane Oxygenation as Bridge to Lung Transplantation
Mechanical circulatory support (MCS) as a bridge to lung transplant is an infrequent but accepted pathway in patients who have refractory end-stage pulmonary failure. The American Association of Thoracic Surgeons Expert Consensus Guidelines, published in 2023, recommends venovenous (VV) extracorporeal membrane oxygenation (ECMO) as the initial configuration for those patients who have failed conventional medical therapy, including mechanical ventilation, while waiting for lung transplantation and needing MCS. Alternatively, venoarterial (VA) ECMO can be used in patients with acute right ventricular failure, hemodynamic instability, or refractory respiratory failure. With the advancement in percutaneous venopulmonary (VP) ECMO cannulation techniques, this option is becoming an attractive configuration as bridge to lung transplantation. This configuration enhances stability of the right ventricle, prevents recirculation with direct introduction of pulmonary artery oxygenation, and promotes hemodynamic stability during mobility, rehabilitation, and sedation-weaning trials before lung transplantation. Here, we present a case series of eight percutaneous VP ECMO as bridge to lung transplant with all patients mobilized, awake, and successfully transplanted with survival to hospital discharge.
- Open Access
- 23 July 2022
- Published by Wiley in Journal of Cardiac Surgery
- Vol. 37 (10) , 3403-3407
First‐in‐man successful use of the SPECTRUM percutaneous dual‐stage right ventricle and right atrium to pulmonary artery ventricular assist device
- 23 July 2022
- Published by Wiley in Journal of Cardiac Surgery
- Vol. 37 (10) , 3403-3407
Open AccessFirst‐in‐man successful use of the SPECTRUM percutaneous dual‐stage right ventricle and right atrium to pulmonary artery ventricular assist device
- 1 October 2020
- Published by Elsevier in Journal of Cardiac Failure
- Vol. 26 (10) , 870-875
Treatment With Impella Increases the Risk of De Novo Aortic Insufficiency Post Left Ventricular Assist Device Implant
- 1 October 2020
- Published by Elsevier in Journal of Cardiac Failure
- Vol. 26 (10) , 870-875
Treatment With Impella Increases the Risk of De Novo Aortic Insufficiency Post Left Ventricular Assist Device Implant
- 1 October 2018
- Published by Elsevier in The Journal of Thoracic and Cardiovascular Surgery
- Vol. 156 (4) , 1643-1651.e7
Preclinical performance of a pediatric mechanical circulatory support device: The PediaFlow ventricular assist device
- 1 October 2018
- Published by Elsevier in The Journal of Thoracic and Cardiovascular Surgery
- Vol. 156 (4) , 1643-1651.e7
Preclinical performance of a pediatric mechanical circulatory support device: The PediaFlow ventricular assist device
- 1 January 2018
- Published by Elsevier in Biomaterials
- Vol. 150, 25-37
Heart valve scaffold fabrication: Bioinspired control of macro-scale morphology, mechanics and micro-structure
- 1 January 2018
- Published by Elsevier in Biomaterials
- Vol. 150, 25-37
Heart valve scaffold fabrication: Bioinspired control of macro-scale morphology, mechanics and micro-structure
- 7 December 2016
- Published by Wiley in Artificial Organs
- Vol. 41 (7) , 678-682
Red Blood Cell Mechanical Fragility Test for Clinical Research Applications
Red blood cell (RBC) susceptibility to mechanically induced hemolysis, or RBC mechanical fragility (MF), is an important parameter in the characterization of erythrocyte membrane health. The rocker bead test (RBT) and associated calculated mechanical fragility index (MFI) is a simple method for the assessment of RBC MF. Requiring a minimum of 15.5 mL of blood and necessitating adjustment of hematocrit (Ht) to a “standard” value (40%), the current RBT is not suitable for use in most studies involving human subjects. To address these limitations, we propose a 6.5 mL reduced volume RBT and corresponding modified MFI (MMFI) that does not require prior Ht adjustment. This new method was assessed for i) correlation to the existing text, ii) to quantify the effect of Ht on MFI, and iii) validation by reexamining the protective effect of plasma proteins on RBC MF. The reduced volume RBT strongly correlated (r = 0.941) with the established large volume RBT at matched Hts, and an equation was developed to calculate MMFI: a numerical estimation (R2 = 0.923) of MFI if performed with the reduced volume RBT at “standard” (40%) Ht. An inversely proportional relationship was found between plasma protein concentration and RBC MF using the MMFI‐reduced volume method, supporting previous literature findings. The new reduced volume RBT and modified MFI will allow for the measurement of RBC MF in clinical and preclinical studies involving humans or small animals.
- 7 December 2016
- Published by Wiley in Artificial Organs
- Vol. 41 (7) , 678-682
Red Blood Cell Mechanical Fragility Test for Clinical Research Applications
Red blood cell (RBC) susceptibility to mechanically induced hemolysis, or RBC mechanical fragility (MF), is an important parameter in the characterization of erythrocyte membrane health. The rocker bead test (RBT) and associated calculated mechanical fragility index (MFI) is a simple method for the assessment of RBC MF. Requiring a minimum of 15.5 mL of blood and necessitating adjustment of hematocrit (Ht) to a “standard” value (40%), the current RBT is not suitable for use in most studies involving human subjects. To address these limitations, we propose a 6.5 mL reduced volume RBT and corresponding modified MFI (MMFI) that does not require prior Ht adjustment. This new method was assessed for i) correlation to the existing text, ii) to quantify the effect of Ht on MFI, and iii) validation by reexamining the protective effect of plasma proteins on RBC MF. The reduced volume RBT strongly correlated (r = 0.941) with the established large volume RBT at matched Hts, and an equation was developed to calculate MMFI: a numerical estimation (R2 = 0.923) of MFI if performed with the reduced volume RBT at “standard” (40%) Ht. An inversely proportional relationship was found between plasma protein concentration and RBC MF using the MMFI‐reduced volume method, supporting previous literature findings. The new reduced volume RBT and modified MFI will allow for the measurement of RBC MF in clinical and preclinical studies involving humans or small animals.
- 1 September 2016
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 62 (5) , 600-606
Ex Vivo Assessment of a Parabolic-Tip Inflow Cannula for Pediatric Continuous-Flow VADs
To address the challenge of unloading the left ventricle during pediatric mechanical circulatory support using next-generation rotary blood pumps, a novel inflow cannula was developed. This unique inflow cannula for pediatric, continuous-flow, left ventricular assist devices (VADs) with a parabolic-shaped inlet entrance was evaluated alongside a bevel-tip and fenestrated-tip cannula via an ex vivo, isolated-heart experimental setup. Performance was characterized using two clinical scenarios of over-pumping and hypovolemia, created by varying pump speed and filling preload pressure, respectively, at ideal and off-axis cannula placement to assess ventricular unloading and positional sensitivity. Quantitative and qualitative assessments were performed on the resultant hemodynamics and intra-ventricular boroscopic images to classify conditions of nonsuction, partial, gradual or severe entrainment, and ventricular collapse. The parabolic-tip cannula was found to be significantly less sensitive to placement position (p < 0.001) than the bevel-tip cannula under all conditions, while not statistically different from the fenestrated cannula. Visual analysis of the parabolic-tip cannula showed complete resistance to entrainment, whereas the fenestrated-tip had partial entrainment in 90% and 87% of the over-pumping and hypovolemic studies, respectively. We conclude that future pediatric VAD designs may benefit from incorporating the parabolic-tip inflow cannula design to maximize unloading of the left ventricle in ideal and nonoptimal conditions.
- 1 September 2016
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 62 (5) , 600-606
Ex Vivo Assessment of a Parabolic-Tip Inflow Cannula for Pediatric Continuous-Flow VADs
To address the challenge of unloading the left ventricle during pediatric mechanical circulatory support using next-generation rotary blood pumps, a novel inflow cannula was developed. This unique inflow cannula for pediatric, continuous-flow, left ventricular assist devices (VADs) with a parabolic-shaped inlet entrance was evaluated alongside a bevel-tip and fenestrated-tip cannula via an ex vivo, isolated-heart experimental setup. Performance was characterized using two clinical scenarios of over-pumping and hypovolemia, created by varying pump speed and filling preload pressure, respectively, at ideal and off-axis cannula placement to assess ventricular unloading and positional sensitivity. Quantitative and qualitative assessments were performed on the resultant hemodynamics and intra-ventricular boroscopic images to classify conditions of nonsuction, partial, gradual or severe entrainment, and ventricular collapse. The parabolic-tip cannula was found to be significantly less sensitive to placement position (p < 0.001) than the bevel-tip cannula under all conditions, while not statistically different from the fenestrated cannula. Visual analysis of the parabolic-tip cannula showed complete resistance to entrainment, whereas the fenestrated-tip had partial entrainment in 90% and 87% of the over-pumping and hypovolemic studies, respectively. We conclude that future pediatric VAD designs may benefit from incorporating the parabolic-tip inflow cannula design to maximize unloading of the left ventricle in ideal and nonoptimal conditions.
- 18 April 2016
- Published by Wiley in Artificial Organs
- Vol. 41 (2) , 175-178
A Reusable, Compliant, Small Volume Blood Reservoir for In Vitro Hemolysis Testing
Bench‐top in vitro hemolysis testing is a fundamental tool during the design and regulatory safety evaluation of blood‐contacting medical devices. While multiple published experimental protocols exist, descriptions of the test loop reservoir remain ambiguous. A critical fixture within the circuit, there is no readily available blood reservoir that ensures thorough mixing and complete air evacuation: two major factors which can affect results. As part of the Food and Drug Administration (FDA) Critical Path Initiative, we developed a three‐piece reservoir consisting of a 3D‐printed base, a plastic clamp set, and a medical‐grade blood bag. This simple, reusable, and cost‐effective design was used successfully in the hemolysis assessment of FDA benchmark nozzles and prototype rotary blood pumps, and may be useful as an integral component to any in vitro blood circulation loop.
- 18 April 2016
- Published by Wiley in Artificial Organs
- Vol. 41 (2) , 175-178
A Reusable, Compliant, Small Volume Blood Reservoir for In Vitro Hemolysis Testing
Bench‐top in vitro hemolysis testing is a fundamental tool during the design and regulatory safety evaluation of blood‐contacting medical devices. While multiple published experimental protocols exist, descriptions of the test loop reservoir remain ambiguous. A critical fixture within the circuit, there is no readily available blood reservoir that ensures thorough mixing and complete air evacuation: two major factors which can affect results. As part of the Food and Drug Administration (FDA) Critical Path Initiative, we developed a three‐piece reservoir consisting of a 3D‐printed base, a plastic clamp set, and a medical‐grade blood bag. This simple, reusable, and cost‐effective design was used successfully in the hemolysis assessment of FDA benchmark nozzles and prototype rotary blood pumps, and may be useful as an integral component to any in vitro blood circulation loop.