TCTimothy B. Curry

Timothy B. Curry

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Timothy B. Curry has a total of 81 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Physiologic validation of the Compensatory Reserve Metric obtained from pulse oximetry: A step toward advanced medical monitoring on the battlefield

    by Richard T. Bs Roden, Kevin L. Bs Webb, Wyatt W. Bs Pruter, Ellen K. Bs Gorman, David R. Iii Holmes, Clifton R. Haider, Michael J. Joyner, Timothy B. Curry, Chad C. Wiggins, Victor A. Convertino

    BACKGROUND: The Compensatory Reserve Metric (CRM) provides a time sensitive indicator of hemodynamic decompensation. However, its in-field utility is limited because of the size and cost-intensive nature of standard vital sign monitors or photoplethysmographic volume-clamp (PPGVC) devices used to measure arterial waveforms. In this regard, photoplethysmographic measurements obtained from pulse oximetry may serve as a useful, portable alternative. This study aimed to validate CRM values obtained using pulse oximeter (PPGPO). METHODS: Forty-nine healthy adults (25 females) underwent a graded lower body negative pressure (LBNP) protocol to simulate hemorrhage. Arterial waveforms were sampled using PPGPO and PPGVC. The CRM was calculated using a one-dimensional convolutional neural network. Cardiac output and stroke volume were measured using PPGVC. A brachial artery catheter was used to measure intra-arterial pressure. A three-lead electrocardiogram was used to measure heart rate. Fixed-effect linear mixed models with repeated measures were used to examine the association between CRM values and physiologic variables. Log-rank analyses were used to examine differences in shock determination during LBNP between monitored hemodynamic parameters. RESULTS: The median LBNP stage reached was 70 mm Hg (range, 45–100 mm Hg). Relative to baseline, at tolerance, there was a 47% ± 12% reduction in stroke volume, 64% ± 27% increase in heart rate, and 21% ± 7% reduction in systolic blood pressure (p < 0.001 for all). Compensatory Reserve Metric values obtained with both PPGPO and PPGVC were associated with changes in heart rate (p < 0.001), stroke volume (p < 0.001), and pulse pressure (p < 0.001). Furthermore, they provided an earlier detection of hemodynamic shock relative to the traditional metrics of shock index (p < 0.001 for both), systolic blood pressure (p < 0.001 for both), and heart rate (p = 0.001 for both). CONCLUSION: The CRM obtained from PPGPO provides a valid, time-sensitized prediction of hemodynamic decompensation, opening the door to provide military medical personnel noninvasive in-field advanced capability for early detection of hemorrhage and imminent onset of shock. LEVEL OF EVIDENCE: Diagnostic Tests or Criteria; Level III.


  • Comparing the compensatory reserve metric obtained from invasive arterial measurements and photoplethysmographic volume-clamp during simulated hemorrhage

    by Kevin L. Webb, Wyatt W. Pruter, Ruth J. Poole, Robert W. Techentin, Christopher P. Johnson, Riley J. Regimbal, Kaylah J. Berndt, David R. Holmes, Clifton R. Haider, Michael J. Joyner, et al.

    Purpose The compensatory reserve metric (CRM) is a novel tool to predict cardiovascular decompensation during hemorrhage. The CRM is traditionally computed using waveforms obtained from photoplethysmographic volume-clamp (PPGVC), yet invasive arterial pressures may be uniquely available. We aimed to examine the level of agreement of CRM values computed from invasive arterial-derived waveforms and values computed from PPGVC-derived waveforms. Methods Sixty-nine participants underwent graded lower body negative pressure to simulate hemorrhage. Waveform measurements from a brachial arterial catheter and PPGVC finger-cuff were collected. A PPGVC brachial waveform was reconstructed from the PPGVC finger waveform. Thereafter, CRM values were computed using a deep one-dimensional convolutional neural network for each of the following source waveforms; (1) invasive arterial, (2) PPGVC brachial, and (3) PPGVC finger. Bland-Altman analyses were used to determine the level of agreement between invasive arterial CRM values and PPGVC CRM values, with results presented as the Mean Bias [95% Limits of Agreement]. Results The mean bias between invasive arterial- and PPGVC brachial CRM values at rest, an applied pressure of -45mmHg, and at tolerance was 6% [-17%, 29%], 1% [-28%, 30%], and 0% [-25%, 25%], respectively. Additionally, the mean bias between invasive arterial- and PPGVC finger CRM values at rest, applied pressure of -45mmHg, and tolerance was 2% [-22%, 26%], 8% [-19%, 35%], and 5% [-15%, 25%], respectively. Conclusion There is generally good agreement between CRM values obtained from invasive arterial waveforms and values obtained from PPGVC waveforms. Invasive arterial waveforms may serve as an alternative for computation of the CRM.


  • Open Access

    AI-Enabled Advanced Development for Assessing Low Circulating Blood Volume for Emergency Medical Care: Comparison of Compensatory Reserve Machine-Learning Algorithms

    by Victor A. Convertino, Robert W. Techentin, Ruth J. Poole, Ashley C. Dacy, Ashli N. Carlson, Sylvain Cardin, Clifton R. Haider, David R. Holmes Iii, Chad C. Wiggins, Michael J. Joyner, et al.

    The application of artificial intelligence (AI) has provided new capabilities to develop advanced medical monitoring sensors for detection of clinical conditions of low circulating blood volume such as hemorrhage. The purpose of this study was to compare for the first time the discriminative ability of two machine learning (ML) algorithms based on real-time feature analysis of arterial waveforms obtained from a non-invasive continuous blood pressure system (Finometer®) signal to predict the onset of decompensated shock: the compensatory reserve index (CRI) and the compensatory reserve metric (CRM). One hundred ninety-one healthy volunteers underwent progressive simulated hemorrhage using lower body negative pressure (LBNP). The least squares means and standard deviations for each measure were assessed by LBNP level and stratified by tolerance status (high vs. low tolerance to central hypovolemia). Generalized Linear Mixed Models were used to perform repeated measures logistic regression analysis by regressing the onset of decompensated shock on CRI and CRM. Sensitivity and specificity were assessed by calculation of receiver-operating characteristic (ROC) area under the curve (AUC) for CRI and CRM. Values for CRI and CRM were not distinguishable across levels of LBNP independent of LBNP tolerance classification, with CRM ROC AUC (0.9268) being statistically similar (p = 0.134) to CRI ROC AUC (0.9164). Both CRI and CRM ML algorithms displayed discriminative ability to predict decompensated shock to include individual subjects with varying levels of tolerance to central hypovolemia. Arterial waveform feature analysis provides a highly sensitive and specific monitoring approach for the detection of ongoing hemorrhage, particularly for those patients at greatest risk for early onset of decompensated shock and requirement for implementation of life-saving interventions.


  • Open Access

    In Reply

    by Brad S. Karon, Leslie J. Donato, Chelsie M. (Larsen) Mogensen, Lindsay K. Siebenaler, Amy E. Wells, Christina M. Wood-Wentz, Mary E. Marienau, Timothy B. Curry

  • Phosphodiesterase-5 inhibition preserves exercise-onset vasodilator kinetics when NOS activity is reduced

    by J. Mikhail Kellawan, Jacqueline K. Limberg, Zachariah M. Scruggs, Wayne T. Nicholson, William G. Schrage, Michael J. Joyner, Timothy B. Curry

    Nitric oxide (NO)-mediated vasodilation contributes to the rapid rise in muscle blood flow at exercise onset. This occurs via increased cyclic guanosine monophosphate (cGMP), which is catabolized by phosphodiesterase-5 (PDE-5). Whether PDE-5 limits exercise vasodilation onset kinetics is unknown. We hypothesized the time course of exercise vasodilation would be 1) accelerated during PDE-5 inhibition (sildenafil citrate, SDF) and 2) decelerated during NO synthase inhibition ( NG-monomethyl-l-arginine, l-NMMA), and 3) the effect of SDF on vasodilation onset kinetics would be attenuated with concurrent l-NMMA. Data from 29 healthy adults were analyzed. Individuals completed 5 min of moderate-intensity forearm exercise under control conditions and during 1) oral SDF ( n = 8), 2) intra-arterial l-NMMA ( n = 15), or 3) combined SDF + l-NMMA ( n = 6). Forearm blood flow (FBF; Doppler ultrasound of the brachial artery) and mean brachial artery blood pressure (MAP) were measured continuously. Forearm vascular conductance (FVC, FBF ÷ MAP) was curve-fit with a monoexponential model, and vasodilation onset kinetics were assessed by mean response time (MRT, time to achieve 63% of steady state). SDF had no effect on MRT ( P = 0.90). NOS inhibition increased MRT ( P = 0.01). MRT during SDF+l-NMMA was not different from control exercise ( P = 0.76). PDE-5 inhibition alone has no effect on rapid-onset vasodilation. Whereas NOS inhibition decelerates vasodilator kinetics, when combined with SDF, vasodilator kinetics do not differ from control. These data suggest NO-independent activation of cGMP occurs at exercise onset; thus PDE-5 inhibition may improve vasodilation in pathologies where NO bioavailability is impaired. NEW & NOTEWORTHY We show that when NO bioavailability is reduced, PDE-5 inhibition can restore vasodilation onset kinetics of exercise-mediated vasodilation via NO-independent cGMP pathways. These data suggest PDE-5 inhibition may improve exercise vasodilation onset kinetics in pathologies where NO bioavailability is impaired.


  • Early blood pressure response to isometric exercise is attenuated in obese individuals who have undergone bariatric surgery

    by Jacqueline K. Limberg, Winston Guo, Michael J. Joyner, Nisha Charkoudian, Timothy B. Curry

    Blood pressure (BP) reactivity is predictive of the development of cardiovascular disease. We hypothesized that the BP response at the onset of isometric handgrip exercise would occur earlier and to a lesser degree in individuals who underwent bariatric surgery compared with obese adults and that the reliance on total peripheral resistance (TPR) would be attenuated. Twenty-six individuals (7 nonobese, 11 obese, 8 postbariatric surgery) completed isometric handgrip exercise (40% maximum voluntary contraction) to exhaustion. Heart rate (HR, ECG) and arterial BP (brachial catheter) were measured continuously. Stroke volume was estimated from the pressure waveform, and cardiac output (CO) and TPR were calculated. Peak change, time to peak, and rate of rise in BP were assessed during the first 30 s of exercise. Obese adults exhibited a slower rise in BP and higher peak BP at exercise onset compared with nonobese controls ( P < 0.05). Peak BP and the rate of rise were not different between individuals who underwent bariatric surgery and nonobese controls ( P > 0.05). Nonobese controls exhibited an exercise-mediated increase in CO, whereas obese adults increased TPR ( P < 0.05). The increases in CO and TPR were less apparent in individuals who underwent bariatric surgery ( P > 0.05). In contrast to obese adults, individuals who underwent bariatric surgery exhibit a rapid rise in BP at exercise onset. This rapid increase in BP is associated with a fall in TPR and results in lower peak BP at the onset of isometric exercise. These data suggest that bariatric surgery improves BP reactivity via changes in the time course of hemodynamic responses. NEW & NOTEWORTHY Bariatric surgery has been shown to reduce the blood pressure (BP) response to isometric handgrip exercise. By examining the time course of the BP response to exercise, we found, in contrast to obese adults, individuals who underwent bariatric surgery exhibit a rapid rise in BP at exercise onset, which is associated with a fall in total peripheral resistance and results in lower peak BP at the onset of isometric exercise. These data suggest that bariatric surgery improves BP reactivity via reflex autonomic adjustments.


  • Open Access

    Accuracy of Capillary and Arterial Whole Blood Glucose Measurements Using a Glucose Meter in Patients under General Anesthesia in the Operating Room

    by Brad S. Karon, Leslie J. Donato, Chelsie M. Larsen, Lindsay K. Siebenaler, Amy E. Wells, Christina M. Wood-Wentz, Mary E. Shirk-Marienau, Timothy B. Curry

    Background: The aim of this study was to evaluate the use of a glucose meter with surgical patients under general anesthesia in the operating room. Methods: Glucose measurements were performed intraoperatively on 368 paired capillary and arterial whole blood samples using a Nova StatStrip (Nova Biomedical, USA) glucose meter and compared with 368 reference arterial whole blood glucose measurements by blood gas analyzer in 196 patients. Primary outcomes were median bias (meter minus reference), percentage of glucose meter samples meeting accuracy criteria for subcutaneous insulin dosing as defined by Parkes error grid analysis for type 1 diabetes mellitus, and accuracy criteria for intravenous insulin infusion as defined by Clinical and Laboratory Standards Institute guidelines. Time under anesthesia, patient position, diabetes status, and other variables were studied to determine whether any affected glucose meter bias. Results: Median bias (interquartile range) was −4 mg/dl (−9 to 0 mg/dl), which did not differ from median arterial meter bias of −5 mg/dl (−9 to −1 mg/dl; P = 0.32). All of the capillary and arterial glucose meter values met acceptability criteria for subcutaneous insulin dosing, whereas only 89% (327 of 368) of capillary and 93% (344 of 368) arterial glucose meter values met accuracy criteria for intravenous insulin infusion. Time, patient position, and diabetes status were not associated with meter bias. Conclusions: Capillary and arterial blood glucose measured using the glucose meter are acceptable for intraoperative subcutaneous insulin dosing. Whole blood glucose on the meter did not meet accuracy guidelines established specifically for more intensive (e.g., intravenous insulin) glycemic control in the acute care environment.


  • Open Access

    Resting sympathetic activity is associated with the sympathetically mediated component of energy expenditure following a meal

    by Jacqueline K. Limberg, Katherine R. Malterer, Luke J. Matzek, James A. Levine, Nisha Charkoudian, John M. Miles, Michael J. Joyner, Timothy B. Curry

    Individuals with high plasma norepinephrine (NE) levels at rest have a smaller reduction in resting energy expenditure (REE) following β‐adrenergic blockade. If this finding extends to the response to a meal, it could have important implications for the role of the sympathetic nervous system in energy balance and weight gain. We hypothesized high muscle sympathetic nerve activity (MSNA) would be associated with a low sympathetically mediated component of energy expenditure following a meal. Fourteen young, healthy adults completed two visits randomized to continuous saline (control) or intravenous propranolol to achieve systemic β‐adrenergic blockade. Muscle sympathetic nerve activity and REE were measured (indirect calorimetry) followed by a liquid mixed meal (Ensure). Measures of energy expenditure continued every 30 min for 5 h after the meal and are reported as an area under the curve (AUC). Sympathetic support of energy expenditure was calculated as the difference between the AUC during saline and β‐blockade (AUCPropranolol–AUCSaline, β‐REE) and as a percent (%) of control (AUCPropranolol÷AUCSaline × 100). β‐REE was associated with baseline sympathetic activity, such that individuals with high resting MSNA (bursts/100 heart beats) and plasma NE had the greatest sympathetically mediated component of energy expenditure following a meal (MSNA: β‐REE R = −0.58, P = 0.03; %REE R = −0.56, P = 0.04; NE: β‐REE R = −0.55, P = 0.0535; %REE R = −0.54, P = 0.0552). Contrary to our hypothesis, high resting sympathetic activity is associated with a greater sympathetically mediated component of energy expenditure following a liquid meal. These findings may have implications for weight maintenance in individuals with varying resting sympathetic activity.


  • Open Access

    Intact blood pressure, but not sympathetic, responsiveness to sympathoexcitatory stimuli in a patient with unilateral carotid body resection

    by Kathryn F. Larson, Jacqueline K. Limberg, Sarah E. Baker, Michael J. Joyner, Timothy B. Curry

    Despite rapidly growing interest in the therapeutic resection of the carotid body (CB) chemoreceptors, few physiologic studies exist on the consequences of unilateral CB resection. We present a case of an otherwise healthy postmenopausal female who underwent unilateral CB resection for a paraganglioma. Approximately 4 years postoperatively, she underwent analysis of her sympathetic and hemodynamic responses to hypoxia, lower body negative pressure, cold pressor test (CPT), and ischemic hand grip exercise and postexercise ischemia (IHE/PEI). Hypoxic ventilatory response and baroreflex sensitivity were relatively normal. Hemodynamic responses to IHE/PEI and CPT showed characteristic increases in cardiac output (from 3.9 L/min to 5.2 L/min [IHE/PEI] and 4.9 L/min [CPT]) and blood pressure (from 126/72 mmHg to 161/87 mmHg [IHE/PEI] and 171/93 mmHg [CPT]). However, muscle sympathetic nerve activity (microneurography of the peroneal nerve) decreased from baseline during IHE/PEI and CPT (burst incidence nadir of 45% and 40% of baseline, respectively) and there was no observable change in total peripheral resistance (from 24 mmHg*min/L to 22 mmHg*min/L [IHE/PEI] and 25 mmHg*min/L [CPT]). These findings illustrate intact blood pressure responsiveness despite attenuated sympathoexcitation, possibly due to an increase in cardiac output and/or adaptive inhibitory effect of the baroreflex on peripheral sympathetic activity.


  • Impact of sleep disordered breathing on carotid body size

    by Brian T. Welch, Humphrey G. Petersen-Jones, Andy R. Eugene, Waleed Brinjikji, David F. Kallmes, Timothy B. Curry, Michael J. Joyner, Jacqueline K. Limberg