Joseph M. Calo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Joseph M. Calo has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Euan J. Bain
School of Engineering, University of Aberdeen, Aberdeen AB24 3UE, Scotland, United Kingdom
3 shared publications George Hradil
3 shared publicationsPengpeng Grimshaw
Brown University, School of Engineering, Providence, RI 02912, USA
3 shared publicationsJohannes Kirchner
School of Engineering, Brown University, Providence, RI 02912, United States
2 shared publicationsElizabeth DiCocco
1 shared publicationJenny Axén
Division of Engineering, Box D, Brown University, Providence, Rhode Island 02912
1 shared publication
Latest Publications
- 4 March 2014
- Published by American Chemical Society (ACS) in Energy & Fuels
- Vol. 28 (3) , 2272-2279
Wetting of Carbonaceous Fuel Particles by Molten Alkali Metal Hydroxide and Carbonate Electrolytes
- 4 March 2014
- Published by American Chemical Society (ACS) in Energy & Fuels
- Vol. 28 (3) , 2272-2279
Wetting of Carbonaceous Fuel Particles by Molten Alkali Metal Hydroxide and Carbonate Electrolytes
- 8 March 2013
- Published by American Chemical Society (ACS) in Energy & Fuels
- Vol. 27 (3) , 1712-1719
Development of a Low Temperature, Molten Hydroxide Direct Carbon Fuel Cell
- 8 March 2013
- Published by American Chemical Society (ACS) in Energy & Fuels
- Vol. 27 (3) , 1712-1719
Development of a Low Temperature, Molten Hydroxide Direct Carbon Fuel Cell
- 1 May 2012
- Published by Elsevier in Chemical Engineering Journal
- Vol. 189-190, 237-243
Arsenic removal via ZVI in a hybrid spouted vessel/fixed bed filter system
- 1 May 2012
- Published by Elsevier in Chemical Engineering Journal
- Vol. 189-190, 237-243
Arsenic removal via ZVI in a hybrid spouted vessel/fixed bed filter system
- 1 November 2011
- Published by Elsevier in Chemical Engineering Journal
- Vol. 175, 103-109
Cyclic electrowinning/precipitation (CEP) system for the removal of heavy metal mixtures from aqueous solutions
- 1 November 2011
- Published by Elsevier in Chemical Engineering Journal
- Vol. 175, 103-109
Cyclic electrowinning/precipitation (CEP) system for the removal of heavy metal mixtures from aqueous solutions
- 11 July 2011
- Published by American Chemical Society (ACS) in Industrial & Engineering Chemistry Research
- Vol. 50 (16) , 9532-9538
III. Co-electrodeposition/Removal of Copper and Nickel in a Spouted Electrochemical Reactor
Results are presented of an investigation of the co-electrodeposition of copper and nickel from acidic solution mixtures in a cylindrical spouted electrochemical reactor. The effects of solution pH, temperature, and applied current on the metal removal/recovery rate, current efficiency, and corrosion of the deposited metals from the cathodic particles were examined under galvanostatic operation. The quantitative and qualitative behavior of co-electrodeposition of the two metals from their mixtures differs significantly from that of the individual single-metal solutions. This is primarily attributed to the metal displacement reaction between Ni0 and Cu2+. This reaction effectively reduces the corrosion of copper and amplifies that of nickel (at least at high concentrations). It also amplifies the separation of the deposition regimes of the two metals in time, which indicates that the recovery of each metal as a relatively pure deposit from the mixture is possible. It was also shown that nitrogen sparging considerably increases the observed net electrodeposition rates for both metals, considerably more so than from solutions with just the single metals alone. A numerical model of co-electrodeposition, corrosion, metal displacement, and mass transfer in the cylindrical spouted electrochemical reactor is presented that describes the behavior of the experimental copper and nickel removal data quite well.
- 11 July 2011
- Published by American Chemical Society (ACS) in Industrial & Engineering Chemistry Research
- Vol. 50 (16) , 9532-9538
III. Co-electrodeposition/Removal of Copper and Nickel in a Spouted Electrochemical Reactor
Results are presented of an investigation of the co-electrodeposition of copper and nickel from acidic solution mixtures in a cylindrical spouted electrochemical reactor. The effects of solution pH, temperature, and applied current on the metal removal/recovery rate, current efficiency, and corrosion of the deposited metals from the cathodic particles were examined under galvanostatic operation. The quantitative and qualitative behavior of co-electrodeposition of the two metals from their mixtures differs significantly from that of the individual single-metal solutions. This is primarily attributed to the metal displacement reaction between Ni0 and Cu2+. This reaction effectively reduces the corrosion of copper and amplifies that of nickel (at least at high concentrations). It also amplifies the separation of the deposition regimes of the two metals in time, which indicates that the recovery of each metal as a relatively pure deposit from the mixture is possible. It was also shown that nitrogen sparging considerably increases the observed net electrodeposition rates for both metals, considerably more so than from solutions with just the single metals alone. A numerical model of co-electrodeposition, corrosion, metal displacement, and mass transfer in the cylindrical spouted electrochemical reactor is presented that describes the behavior of the experimental copper and nickel removal data quite well.
- 11 July 2011
- Published by American Chemical Society (ACS) in Industrial & Engineering Chemistry Research
- Vol. 50 (16) , 9525-9531
II. Electrodeposition/Removal of Nickel in a Spouted Electrochemical Reactor
An investigation is presented of nickel electrodeposition from acidic solutions in a cylindrical spouted electrochemical reactor. The effects of solution pH, temperature, and applied current on nickel removal/recovery rate, current efficiency, and corrosion rate of deposited nickel on the cathodic particles were explored under galvanostatic operation. Nitrogen sparging was used to decrease the dissolved oxygen concentration in the electrolyte in order to reduce the nickel corrosion rate, thereby increasing the nickel electrowinning rate and current efficiency. A numerical model of electrodeposition, including corrosion and mass transfer in the particulate cathode moving bed, is presented that describes the behavior of the experimental net nickel electrodeposition data quite well.
- 11 July 2011
- Published by American Chemical Society (ACS) in Industrial & Engineering Chemistry Research
- Vol. 50 (16) , 9525-9531
II. Electrodeposition/Removal of Nickel in a Spouted Electrochemical Reactor
An investigation is presented of nickel electrodeposition from acidic solutions in a cylindrical spouted electrochemical reactor. The effects of solution pH, temperature, and applied current on nickel removal/recovery rate, current efficiency, and corrosion rate of deposited nickel on the cathodic particles were explored under galvanostatic operation. Nitrogen sparging was used to decrease the dissolved oxygen concentration in the electrolyte in order to reduce the nickel corrosion rate, thereby increasing the nickel electrowinning rate and current efficiency. A numerical model of electrodeposition, including corrosion and mass transfer in the particulate cathode moving bed, is presented that describes the behavior of the experimental net nickel electrodeposition data quite well.
- 15 March 2010
- Published by American Chemical Society (ACS) in Energy & Fuels
- Vol. 24 (6) , 3415-3421
Electrosorption/Electrodesorption of Arsenic on a Granular Activated Carbon in the Presence of Other Heavy Metals
The adsorption, electrosorption, and electrodesorption of aqueous, inorganic arsenic on the granular activated carbon (GAC), DARCO 12 × 20 (Darco 1220) GAC, were investigated in solutions containing arsenic as the only contaminant, as well as with chromium, nickel, and iron. Darco 1220 was selected for these investigations primarily because it is relatively ineffective as a normal (unassisted) arsenic adsorbent in the chosen electrolytes at the low loadings used. It is shown that the application of anodic potentials in the 1.0−1.5 V range, however, result in enhanced uptake, most likely because of charging of the electrochemical double layer at the electrode surface. Regeneration (100%) of electrosorbed arsenic was achieved via electrodesorption at a cathodic potential of 1.50 V. The presence of metal ad ions was observed to have a significant and complex effect on arsenic adsorption, electrosorption, and electrodesorption. In particular, the Cr/As ratio was shown to have complex effects, decreasing adsorption uptake when present as 3:2 but enhancing adsorption when present as 5:1. Nickel was found to have less of an effect than chromium, except at the highest anodic potential used of 1.50 V, where it exhibited better performance than chromium. The presence of iron significantly enhanced uptake. With a 1.50 V anodic potential, the bulk arsenic concentration was reduced to less than detectable limits, well below the United States Environmental Protection Agency (U.S. EPA) maximum contaminant level (MCL) for drinking water. Regeneration efficiency by electrodesorption for the As−Fe system was greater than about 90%.
- 15 March 2010
- Published by American Chemical Society (ACS) in Energy & Fuels
- Vol. 24 (6) , 3415-3421
Electrosorption/Electrodesorption of Arsenic on a Granular Activated Carbon in the Presence of Other Heavy Metals
The adsorption, electrosorption, and electrodesorption of aqueous, inorganic arsenic on the granular activated carbon (GAC), DARCO 12 × 20 (Darco 1220) GAC, were investigated in solutions containing arsenic as the only contaminant, as well as with chromium, nickel, and iron. Darco 1220 was selected for these investigations primarily because it is relatively ineffective as a normal (unassisted) arsenic adsorbent in the chosen electrolytes at the low loadings used. It is shown that the application of anodic potentials in the 1.0−1.5 V range, however, result in enhanced uptake, most likely because of charging of the electrochemical double layer at the electrode surface. Regeneration (100%) of electrosorbed arsenic was achieved via electrodesorption at a cathodic potential of 1.50 V. The presence of metal ad ions was observed to have a significant and complex effect on arsenic adsorption, electrosorption, and electrodesorption. In particular, the Cr/As ratio was shown to have complex effects, decreasing adsorption uptake when present as 3:2 but enhancing adsorption when present as 5:1. Nickel was found to have less of an effect than chromium, except at the highest anodic potential used of 1.50 V, where it exhibited better performance than chromium. The presence of iron significantly enhanced uptake. With a 1.50 V anodic potential, the bulk arsenic concentration was reduced to less than detectable limits, well below the United States Environmental Protection Agency (U.S. EPA) maximum contaminant level (MCL) for drinking water. Regeneration efficiency by electrodesorption for the As−Fe system was greater than about 90%.