Geoffrey D. Hugo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Geoffrey D. Hugo has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
Elisabeth Weiss
Department of Radiation Oncology, Virginia Commonwealth University, Richmond, Virginia
10 shared publications- Ahmed M. Badawi
Cairo Univ. (Egypt)
3 shared publications - Nuzhat Jan
Department of Radiation Oncology, Virginia Commonwealth University, Richmond, Virginia
3 shared publications - Scott P. Robertson
Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Baltimore, Maryland
3 shared publications William C. Sleeman
Department of Radiation Oncology, Virginia Commonwealth University, Richmond, VA, 23298, USA
3 shared publicationsDi Yan
William Beaumont Hosp, Dept Radiat Oncol, Royal Oak, MI USA
2 shared publications
Latest Publications
- Open Access
- 1 January 2017
- Published by Elsevier in Advances in Radiation Oncology
- Vol. 2 (1) , 19-26
Effect of variations in atelectasis on tumor displacement during radiation therapy for locally advanced lung cancer
- 1 January 2017
- Published by Elsevier in Advances in Radiation Oncology
- Vol. 2 (1) , 19-26
Open AccessEffect of variations in atelectasis on tumor displacement during radiation therapy for locally advanced lung cancer
- 19 December 2016
- Published by Wiley in Medical Physics
- Vol. 44 (2) , 762-771
A longitudinal four‐dimensional computed tomography and cone beam computed tomography dataset for image‐guided radiation therapy research in lung cancer
Purpose: To describe in detail a dataset consisting of serial four‐dimensional computed tomography (4DCT) and 4D cone beam CT (4DCBCT) images acquired during chemoradiotherapy of 20 locally advanced, nonsmall cell lung cancer patients we have collected at our institution and shared publicly with the research community.Acquisition and validation methods: As part of an NCI‐sponsored research study 82 4DCT and 507 4DCBCT images were acquired in a population of 20 locally advanced nonsmall cell lung cancer patients undergoing radiation therapy. All subjects underwent concurrent radiochemotherapy to a total dose of 59.4–70.2 Gy using daily 1.8 or 2 Gy fractions. Audio‐visual biofeedback was used to minimize breathing irregularity during all fractions, including acquisition of all 4DCT and 4DCBCT acquisitions in all subjects. Target, organs at risk, and implanted fiducial markers were delineated by a physician in the 4DCT images. Image coordinate system origins between 4DCT and 4DCBCT were manipulated in such a way that the images can be used to simulate initial patient setup in the treatment position. 4DCT images were acquired on a 16‐slice helical CT simulator with 10 breathing phases and 3 mm slice thickness during simulation. In 13 of the 20 subjects, 4DCTs were also acquired on the same scanner weekly during therapy. Every day, 4DCBCT images were acquired on a commercial onboard CBCT scanner. An optically tracked external surrogate was synchronized with CBCT acquisition so that each CBCT projection was time stamped with the surrogate respiratory signal through in‐house software and hardware tools. Approximately 2500 projections were acquired over a period of 8–10 minutes in half‐fan mode with the half bow‐tie filter. Using the external surrogate, the CBCT projections were sorted into 10 breathing phases and reconstructed with an in‐house FDK reconstruction algorithm. Errors in respiration sorting, reconstruction, and acquisition were carefully identified and corrected.Data format and usage notes: 4DCT and 4DCBCT images are available in DICOM format and structures through DICOM‐RT RTSTRUCT format. All data are stored in the Cancer Imaging Archive (TCIA, http://www.cancerimagingarchive.net/) as collection 4D‐Lung and are publicly available.Discussion: Due to high temporal frequency sampling, redundant (4DCT and 4DCBCT) data at similar timepoints, oversampled 4DCBCT, and fiducial markers, this dataset can support studies in image‐guided and image‐guided adaptive radiotherapy, assessment of 4D voxel trajectory variability, and development and validation of new tools for image registration and motion management.
- 19 December 2016
- Published by Wiley in Medical Physics
- Vol. 44 (2) , 762-771
A longitudinal four‐dimensional computed tomography and cone beam computed tomography dataset for image‐guided radiation therapy research in lung cancer
Purpose: To describe in detail a dataset consisting of serial four‐dimensional computed tomography (4DCT) and 4D cone beam CT (4DCBCT) images acquired during chemoradiotherapy of 20 locally advanced, nonsmall cell lung cancer patients we have collected at our institution and shared publicly with the research community.Acquisition and validation methods: As part of an NCI‐sponsored research study 82 4DCT and 507 4DCBCT images were acquired in a population of 20 locally advanced nonsmall cell lung cancer patients undergoing radiation therapy. All subjects underwent concurrent radiochemotherapy to a total dose of 59.4–70.2 Gy using daily 1.8 or 2 Gy fractions. Audio‐visual biofeedback was used to minimize breathing irregularity during all fractions, including acquisition of all 4DCT and 4DCBCT acquisitions in all subjects. Target, organs at risk, and implanted fiducial markers were delineated by a physician in the 4DCT images. Image coordinate system origins between 4DCT and 4DCBCT were manipulated in such a way that the images can be used to simulate initial patient setup in the treatment position. 4DCT images were acquired on a 16‐slice helical CT simulator with 10 breathing phases and 3 mm slice thickness during simulation. In 13 of the 20 subjects, 4DCTs were also acquired on the same scanner weekly during therapy. Every day, 4DCBCT images were acquired on a commercial onboard CBCT scanner. An optically tracked external surrogate was synchronized with CBCT acquisition so that each CBCT projection was time stamped with the surrogate respiratory signal through in‐house software and hardware tools. Approximately 2500 projections were acquired over a period of 8–10 minutes in half‐fan mode with the half bow‐tie filter. Using the external surrogate, the CBCT projections were sorted into 10 breathing phases and reconstructed with an in‐house FDK reconstruction algorithm. Errors in respiration sorting, reconstruction, and acquisition were carefully identified and corrected.Data format and usage notes: 4DCT and 4DCBCT images are available in DICOM format and structures through DICOM‐RT RTSTRUCT format. All data are stored in the Cancer Imaging Archive (TCIA, http://www.cancerimagingarchive.net/) as collection 4D‐Lung and are publicly available.Discussion: Due to high temporal frequency sampling, redundant (4DCT and 4DCBCT) data at similar timepoints, oversampled 4DCBCT, and fiducial markers, this dataset can support studies in image‐guided and image‐guided adaptive radiotherapy, assessment of 4D voxel trajectory variability, and development and validation of new tools for image registration and motion management.
- 22 March 2016
- Published by Wiley in Medical Physics
- Vol. 43 (4) , 1787-1794
Benefits of adaptive radiation therapy in lung cancer as a function of replanning frequency
Purpose: To quantify the potential benefit associated with daily replanning in lung cancer in terms of normal tissue dose sparing and to characterize the tradeoff between adaptive benefit and replanning frequency.Methods: A set of synthetic images and contours, derived from weekly active breathing control images of 12 patients who underwent radiation therapy treatment for nonsmall cell lung cancer, is generated for each fraction of treatment using principal component analysis in a way that preserves temporal anatomical trends (e.g., tumor regression). Daily synthetic images and contours are used to simulate four different treatment scenarios: (1) a “no‐adapt” scenario that simulates delivery of an initial plan throughout treatment, (2) a “midadapt” scenario that implements a single replan for fraction 18, (3) a “weekly adapt” scenario that simulates weekly adaptations, and (4) a “full‐adapt” scenario that simulates daily replanning. An initial intensity modulated radiation therapy plan is created for each patient and replanning is carried out in an automated fashion by reoptimizing beam apertures and weights. Dose is calculated on each image and accumulated to the first in the series using deformable mappings utilized in synthetic image creation for comparison between simulated treatments.Results: Target coverage was maintained and cord tolerance was not exceeded for any of the adaptive simulations. Average reductions in mean lung dose (MLD) and volume of lung receiving 20 Gy or more (V20lung) were 65 ± 49 cGy (p = 0.000 01) and 1.1% ± 1.2% (p = 0.0006), respectively, for all patients. The largest reduction in MLD for a single patient was 162 cGy, which allowed an isotoxic escalation of the target dose of 1668 cGy. Average reductions in cord max dose, mean esophageal dose (MED), dose received by 66% of the heart (D66heart), and dose received by 33% of the heart (D33heart), were 158 ± 280, 117 ± 121, 37 ± 77, and 99 ± 120 cGy, respectively. Average incremental reductions in MLD for the midadapt, weekly adapt, and full‐adapt treatments were 38, 18, and 8 cGy, respectively. Incremental reductions in MED for the same treatments were 57, 37, and 23 cGy. Reductions in MLD and MED for the full‐adapt treatment were correlated with the absolute decrease in the planning target volume (r = 0.34 and r = 0.26).Conclusions: Adaptive radiation therapy for lung cancer yields clinically relevant reductions in normal tissue doses for frequencies of adaptation ranging from a single replan up to daily replanning. Increased frequencies of adaptation result in additional benefit while magnitude of benefit decreases.
- 22 March 2016
- Published by Wiley in Medical Physics
- Vol. 43 (4) , 1787-1794
Benefits of adaptive radiation therapy in lung cancer as a function of replanning frequency
Purpose: To quantify the potential benefit associated with daily replanning in lung cancer in terms of normal tissue dose sparing and to characterize the tradeoff between adaptive benefit and replanning frequency.Methods: A set of synthetic images and contours, derived from weekly active breathing control images of 12 patients who underwent radiation therapy treatment for nonsmall cell lung cancer, is generated for each fraction of treatment using principal component analysis in a way that preserves temporal anatomical trends (e.g., tumor regression). Daily synthetic images and contours are used to simulate four different treatment scenarios: (1) a “no‐adapt” scenario that simulates delivery of an initial plan throughout treatment, (2) a “midadapt” scenario that implements a single replan for fraction 18, (3) a “weekly adapt” scenario that simulates weekly adaptations, and (4) a “full‐adapt” scenario that simulates daily replanning. An initial intensity modulated radiation therapy plan is created for each patient and replanning is carried out in an automated fashion by reoptimizing beam apertures and weights. Dose is calculated on each image and accumulated to the first in the series using deformable mappings utilized in synthetic image creation for comparison between simulated treatments.Results: Target coverage was maintained and cord tolerance was not exceeded for any of the adaptive simulations. Average reductions in mean lung dose (MLD) and volume of lung receiving 20 Gy or more (V20lung) were 65 ± 49 cGy (p = 0.000 01) and 1.1% ± 1.2% (p = 0.0006), respectively, for all patients. The largest reduction in MLD for a single patient was 162 cGy, which allowed an isotoxic escalation of the target dose of 1668 cGy. Average reductions in cord max dose, mean esophageal dose (MED), dose received by 66% of the heart (D66heart), and dose received by 33% of the heart (D33heart), were 158 ± 280, 117 ± 121, 37 ± 77, and 99 ± 120 cGy, respectively. Average incremental reductions in MLD for the midadapt, weekly adapt, and full‐adapt treatments were 38, 18, and 8 cGy, respectively. Incremental reductions in MED for the same treatments were 57, 37, and 23 cGy. Reductions in MLD and MED for the full‐adapt treatment were correlated with the absolute decrease in the planning target volume (r = 0.34 and r = 0.26).Conclusions: Adaptive radiation therapy for lung cancer yields clinically relevant reductions in normal tissue doses for frequencies of adaptation ranging from a single replan up to daily replanning. Increased frequencies of adaptation result in additional benefit while magnitude of benefit decreases.
- Open Access
- 14 June 2015
- Published by Springer Nature in Radiation Oncology
- Vol. 10 (1) , 133
Respiratory motion variability of primary tumors and lymph nodes during radiotherapy of locally advanced non-small-cell lung cancers
The need for target adjustment due to respiratory motion variation and the value of carina as a motion surrogate is evaluated for locally advanced non-small-cell lung cancer. Using weekly 4D CTs (with audio-visual biofeedback) of 12 patients, respiratory motion variation of primary tumors (PT), lymph nodes (LN) and carina (C) were determined. Mean (SD) 3D respiratory motion ranges of PT, LN and C were 4 (3), 5 (3) and 5 (3) mm. PT and LN (p = 0.003), and LN and C motion range were correlated (p = 0.03). Only 20 %/5 % of all scans had variations >3 mm/5 mm. Large respiratory motion range on the initial scan was associated with larger during-treatment variations for PT (p = 0.03) and LN (p = 0.001). Mean (SD) 3D relative displacements of PT-C, LN-C and PT-LN were each 6 (2) mm. Variations of displacements >3 mm/5 mm were observed in 28 %/6 % of scans for PT-LN, 20 %/9 % for PT-C, and 20 %/8 % for LN-C. Motion reassessment is recommended in patients with large initial motion range. Relative motion-related displacements between PT and LN were larger than PT and LN motion alone. Both PT and C appear to be comparable surrogates for LN respiratory motion.
- 14 June 2015
- Published by Springer Nature in Radiation Oncology
- Vol. 10 (1) , 133
Open AccessRespiratory motion variability of primary tumors and lymph nodes during radiotherapy of locally advanced non-small-cell lung cancers
The need for target adjustment due to respiratory motion variation and the value of carina as a motion surrogate is evaluated for locally advanced non-small-cell lung cancer. Using weekly 4D CTs (with audio-visual biofeedback) of 12 patients, respiratory motion variation of primary tumors (PT), lymph nodes (LN) and carina (C) were determined. Mean (SD) 3D respiratory motion ranges of PT, LN and C were 4 (3), 5 (3) and 5 (3) mm. PT and LN (p = 0.003), and LN and C motion range were correlated (p = 0.03). Only 20 %/5 % of all scans had variations >3 mm/5 mm. Large respiratory motion range on the initial scan was associated with larger during-treatment variations for PT (p = 0.03) and LN (p = 0.001). Mean (SD) 3D relative displacements of PT-C, LN-C and PT-LN were each 6 (2) mm. Variations of displacements >3 mm/5 mm were observed in 28 %/6 % of scans for PT-LN, 20 %/9 % for PT-C, and 20 %/8 % for LN-C. Motion reassessment is recommended in patients with large initial motion range. Relative motion-related displacements between PT and LN were larger than PT and LN motion alone. Both PT and C appear to be comparable surrogates for LN respiratory motion.
- 13 March 2014
- Published by Wiley in Medical Physics
- Vol. 41 (4) , 041704
A block matching‐based registration algorithm for localization of locally advanced lung tumors
Purpose:: To implement and evaluate a block matching‐based registration (BMR) algorithm for locally advanced lung tumor localization during image‐guided radiotherapy.Methods:: Small (1 cm3), nonoverlapping image subvolumes (“blocks”) were automatically identified on the planning image to cover the tumor surface using a measure of the local intensity gradient. Blocks were independently and automatically registered to the on‐treatment image using a rigid transform. To improve speed and robustness, registrations were performed iteratively from coarse to fine image resolution. At each resolution, all block displacements having a near‐maximum similarity score were stored. From this list, a single displacement vector for each block was iteratively selected which maximized the consistency of displacement vectors across immediately neighboring blocks. These selected displacements were regularized using a median filter before proceeding to registrations at finer image resolutions. After evaluating all image resolutions, the global rigid transform of the on‐treatment image was computed using a Procrustes analysis, providing the couch shift for patient setup correction. This algorithm was evaluated for 18 locally advanced lung cancer patients, each with 4–7 weekly on‐treatment computed tomography scans having physician‐delineated gross tumor volumes. Volume overlap (VO) and border displacement errors (BDE) were calculated relative to the nominal physician‐identified targets to establish residual error after registration.Results:: Implementation of multiresolution registration improved block matching accuracy by 39% compared to registration using only the full resolution images. By also considering multiple potential displacements per block, initial errors were reduced by 65%. Using the final implementation of the BMR algorithm, VO was significantly improved from 77% ± 21% (range: 0%–100%) in the initial bony alignment to 91% ± 8% (range: 56%–100%;p < 0.001). Left‐right, anterior‐posterior, and superior‐inferior systematic BDE were 3.2, 2.4, and 4.4 mm, respectively, with random BDE of 2.4, 2.1, and 2.7 mm. Margins required to include both localization and delineation uncertainties ranged from 5.0 to 11.7 mm, an average of 40% less than required for bony alignment.Conclusions:: BMR is a promising approach for automatic lung tumor localization. Further evaluation is warranted to assess the accuracy and robustness of BMR against other potential localization strategies.
- 13 March 2014
- Published by Wiley in Medical Physics
- Vol. 41 (4) , 041704
A block matching‐based registration algorithm for localization of locally advanced lung tumors
Purpose:: To implement and evaluate a block matching‐based registration (BMR) algorithm for locally advanced lung tumor localization during image‐guided radiotherapy.Methods:: Small (1 cm3), nonoverlapping image subvolumes (“blocks”) were automatically identified on the planning image to cover the tumor surface using a measure of the local intensity gradient. Blocks were independently and automatically registered to the on‐treatment image using a rigid transform. To improve speed and robustness, registrations were performed iteratively from coarse to fine image resolution. At each resolution, all block displacements having a near‐maximum similarity score were stored. From this list, a single displacement vector for each block was iteratively selected which maximized the consistency of displacement vectors across immediately neighboring blocks. These selected displacements were regularized using a median filter before proceeding to registrations at finer image resolutions. After evaluating all image resolutions, the global rigid transform of the on‐treatment image was computed using a Procrustes analysis, providing the couch shift for patient setup correction. This algorithm was evaluated for 18 locally advanced lung cancer patients, each with 4–7 weekly on‐treatment computed tomography scans having physician‐delineated gross tumor volumes. Volume overlap (VO) and border displacement errors (BDE) were calculated relative to the nominal physician‐identified targets to establish residual error after registration.Results:: Implementation of multiresolution registration improved block matching accuracy by 39% compared to registration using only the full resolution images. By also considering multiple potential displacements per block, initial errors were reduced by 65%. Using the final implementation of the BMR algorithm, VO was significantly improved from 77% ± 21% (range: 0%–100%) in the initial bony alignment to 91% ± 8% (range: 56%–100%;p < 0.001). Left‐right, anterior‐posterior, and superior‐inferior systematic BDE were 3.2, 2.4, and 4.4 mm, respectively, with random BDE of 2.4, 2.1, and 2.7 mm. Margins required to include both localization and delineation uncertainties ranged from 5.0 to 11.7 mm, an average of 40% less than required for bony alignment.Conclusions:: BMR is a promising approach for automatic lung tumor localization. Further evaluation is warranted to assess the accuracy and robustness of BMR against other potential localization strategies.
- 18 June 2013
- Published by Wiley in Medical Physics
- Vol. 40 (7) , 071721
Deformable mesh registration for the validation of automatic target localization algorithms
Purpose:: To evaluate deformable mesh registration (DMR) as a tool for validating automatic target registration algorithms used during image‐guided radiation therapy.Methods:: DMR was implemented in a hierarchical model, with rigid, affine, and B‐spline transforms optimized in succession to register a pair of surface meshes. The gross tumor volumes (primary tumor and involved lymph nodes) were contoured by a physician on weekly CT scans in a cohort of lung cancer patients and converted to surface meshes. The meshes from weekly CT images were registered to the mesh from the planning CT, and the resulting registered meshes were compared with the delineated surfaces. Known deformations were also applied to the meshes, followed by mesh registration to recover the known deformation. Mesh registration accuracy was assessed at the mesh surface by computing the symmetric surface distance (SSD) between vertices of each registered mesh pair. Mesh registration quality in regions within 5 mm of the mesh surface was evaluated with respect to a high quality deformable image registration.Results:: For 18 patients presenting with a total of 19 primary lung tumors and 24 lymph node targets, the SSD averaged 1.3 ± 0.5 and 0.8 ± 0.2 mm, respectively. Vertex registration errors (VRE) relative to the applied known deformation were 0.8 ± 0.7 and 0.2 ± 0.3 mm for the primary tumor and lymph nodes, respectively. Inside the mesh surface, corresponding average VRE ranged from 0.6 to 0.9 and 0.2 to 0.9 mm, respectively. Outside the mesh surface, average VRE ranged from 0.7 to 1.8 and 0.2 to 1.4 mm. The magnitude of errors generally increased with increasing distance away from the mesh.Conclusions:: Provided that delineated surfaces are available, deformable mesh registration is an accurate and reliable method for obtaining a reference registration to validate automatic target registration algorithms for image‐guided radiation therapy, specifically in regions on or near the target surfaces.
- 18 June 2013
- Published by Wiley in Medical Physics
- Vol. 40 (7) , 071721
Deformable mesh registration for the validation of automatic target localization algorithms
Purpose:: To evaluate deformable mesh registration (DMR) as a tool for validating automatic target registration algorithms used during image‐guided radiation therapy.Methods:: DMR was implemented in a hierarchical model, with rigid, affine, and B‐spline transforms optimized in succession to register a pair of surface meshes. The gross tumor volumes (primary tumor and involved lymph nodes) were contoured by a physician on weekly CT scans in a cohort of lung cancer patients and converted to surface meshes. The meshes from weekly CT images were registered to the mesh from the planning CT, and the resulting registered meshes were compared with the delineated surfaces. Known deformations were also applied to the meshes, followed by mesh registration to recover the known deformation. Mesh registration accuracy was assessed at the mesh surface by computing the symmetric surface distance (SSD) between vertices of each registered mesh pair. Mesh registration quality in regions within 5 mm of the mesh surface was evaluated with respect to a high quality deformable image registration.Results:: For 18 patients presenting with a total of 19 primary lung tumors and 24 lymph node targets, the SSD averaged 1.3 ± 0.5 and 0.8 ± 0.2 mm, respectively. Vertex registration errors (VRE) relative to the applied known deformation were 0.8 ± 0.7 and 0.2 ± 0.3 mm for the primary tumor and lymph nodes, respectively. Inside the mesh surface, corresponding average VRE ranged from 0.6 to 0.9 and 0.2 to 0.9 mm, respectively. Outside the mesh surface, average VRE ranged from 0.7 to 1.8 and 0.2 to 1.4 mm. The magnitude of errors generally increased with increasing distance away from the mesh.Conclusions:: Provided that delineated surfaces are available, deformable mesh registration is an accurate and reliable method for obtaining a reference registration to validate automatic target registration algorithms for image‐guided radiation therapy, specifically in regions on or near the target surfaces.
- Open Access
- 1 December 2012
- Published by Elsevier in Zeitschrift für Medizinische Physik
- Vol. 22 (4) , 258-271
Advances in 4D radiation therapy for managing respiration: Part I – 4D imaging
- 1 December 2012
- Published by Elsevier in Zeitschrift für Medizinische Physik
- Vol. 22 (4) , 258-271
Open AccessAdvances in 4D radiation therapy for managing respiration: Part I – 4D imaging
- 21 December 2011
- Published by Wiley in Medical Physics
- Vol. 39 (1) , 330-341
Localization accuracy from automatic and semi-automatic rigid registration of locally-advanced lung cancer targets during image-guided radiation therapy
Purpose: To evaluate localization accuracy resulting from rigid registration of locally-advanced lungcancer targets using fully automatic and semi-automatic protocols for image-guided radiation therapy. Methods: Seventeen lungcancer patients, fourteen also presenting with involved lymph nodes, received computed tomography(CT) scans once per week throughout treatment under active breathing control. A physician contoured both lung and lymph node targets for all weekly scans. Various automatic and semi-automatic rigid registration techniques were then performed for both individual and simultaneous alignments of the primary gross tumor volume (GTVP) and involved lymph nodes (GTVLN) to simulate the localization process in image-guided radiation therapy. Techniques included “standard” (direct registration of weekly images to a planning CT), “seeded” (manual prealignment of targets to guide standard registration), “transitive-based” (alignment of pretreatment and planning CTs through one or more intermediate images), and “rereferenced” (designation of a new reference image for registration). Localization error (LE) was assessed as the residual centroid and border distances between targets from planning and weekly CTs after registration. Results: Initial bony alignment resulted in centroid LE of 7.3 ± 5.4 mm and 5.4 ± 3.4 mm for the GTVP and GTVLN, respectively. Compared to bony alignment, transitive-based and seeded registrations significantly reduced GTVP centroid LE to 4.7 ± 3.7 mm (p = 0.011) and 4.3 ± 2.5 mm (p < 1 × 10−3), respectively, but the smallest GTVP LE of 2.4 ± 2.1 mm was provided by rereferenced registration (p < 1 × 10−6). Standard registration significantly reduced GTVLN centroid LE to 3.2 ± 2.5 mm (p < 1 × 10−3) compared to bony alignment, with little additional gain offered by the other registration techniques. For simultaneous target alignment, centroid LE as low as 3.9 ± 2.7 mm and 3.8 ± 2.3 mm were achieved for the GTVP and GTVLN, respectively, using rereferenced registration. Conclusions: Target shape, volume, and configuration changes during radiation therapy limited the accuracy of standard rigid registration for image-guided localization in locally-advanced lungcancer. Significant error reductions were possible using other rigid registration techniques, with LE approaching the lower limit imposed by interfraction target variability throughout treatment.
- 21 December 2011
- Published by Wiley in Medical Physics
- Vol. 39 (1) , 330-341
Localization accuracy from automatic and semi-automatic rigid registration of locally-advanced lung cancer targets during image-guided radiation therapy
Purpose: To evaluate localization accuracy resulting from rigid registration of locally-advanced lungcancer targets using fully automatic and semi-automatic protocols for image-guided radiation therapy. Methods: Seventeen lungcancer patients, fourteen also presenting with involved lymph nodes, received computed tomography(CT) scans once per week throughout treatment under active breathing control. A physician contoured both lung and lymph node targets for all weekly scans. Various automatic and semi-automatic rigid registration techniques were then performed for both individual and simultaneous alignments of the primary gross tumor volume (GTVP) and involved lymph nodes (GTVLN) to simulate the localization process in image-guided radiation therapy. Techniques included “standard” (direct registration of weekly images to a planning CT), “seeded” (manual prealignment of targets to guide standard registration), “transitive-based” (alignment of pretreatment and planning CTs through one or more intermediate images), and “rereferenced” (designation of a new reference image for registration). Localization error (LE) was assessed as the residual centroid and border distances between targets from planning and weekly CTs after registration. Results: Initial bony alignment resulted in centroid LE of 7.3 ± 5.4 mm and 5.4 ± 3.4 mm for the GTVP and GTVLN, respectively. Compared to bony alignment, transitive-based and seeded registrations significantly reduced GTVP centroid LE to 4.7 ± 3.7 mm (p = 0.011) and 4.3 ± 2.5 mm (p < 1 × 10−3), respectively, but the smallest GTVP LE of 2.4 ± 2.1 mm was provided by rereferenced registration (p < 1 × 10−6). Standard registration significantly reduced GTVLN centroid LE to 3.2 ± 2.5 mm (p < 1 × 10−3) compared to bony alignment, with little additional gain offered by the other registration techniques. For simultaneous target alignment, centroid LE as low as 3.9 ± 2.7 mm and 3.8 ± 2.3 mm were achieved for the GTVP and GTVLN, respectively, using rereferenced registration. Conclusions: Target shape, volume, and configuration changes during radiation therapy limited the accuracy of standard rigid registration for image-guided localization in locally-advanced lungcancer. Significant error reductions were possible using other rigid registration techniques, with LE approaching the lower limit imposed by interfraction target variability throughout treatment.
- 15 December 2011
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 57 (2) , 395-413
Classifying geometric variability by dominant eigenmodes of deformation in regressing tumours during active breath-hold lung cancer radiotherapy
The purpose of this study is to develop and evaluate a lung tumour interfraction geometric variability classification scheme as a means to guide adaptive radiotherapy and improve measurement of treatment response. Principal component analysis (PCA) was used to generate statistical shape models of the gross tumour volume (GTV) for 12 patients with weekly breath hold CT scans. Each eigenmode of the PCA model was classified as 'trending' or 'non-trending' depending on whether its contribution to the overall GTV variability included a time trend over the treatment course. Trending eigenmodes were used to reconstruct the original semi-automatically delineated GTVs into a reduced model containing only time trends. Reduced models were compared to the original GTVs by analyzing the reconstruction error in the GTV and position. Both retrospective (all weekly images) and prospective (only the first four weekly images) were evaluated. The average volume difference from the original GTV was 4.3% ± 2.4% for the trending model. The positional variability of the GTV over the treatment course, as measured by the standard deviation of the GTV centroid, was 1.9 ± 1.4 mm for the original GTVs, which was reduced to 1.2 ± 0.6 mm for the trending-only model. In 3/13 cases, the dominant eigenmode changed class between the prospective and retrospective models. The trending-only model preserved GTV and shape relative to the original GTVs, while reducing spurious positional variability. The classification scheme appears feasible for separating types of geometric variability by time trend.
- 15 December 2011
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 57 (2) , 395-413
Classifying geometric variability by dominant eigenmodes of deformation in regressing tumours during active breath-hold lung cancer radiotherapy
The purpose of this study is to develop and evaluate a lung tumour interfraction geometric variability classification scheme as a means to guide adaptive radiotherapy and improve measurement of treatment response. Principal component analysis (PCA) was used to generate statistical shape models of the gross tumour volume (GTV) for 12 patients with weekly breath hold CT scans. Each eigenmode of the PCA model was classified as 'trending' or 'non-trending' depending on whether its contribution to the overall GTV variability included a time trend over the treatment course. Trending eigenmodes were used to reconstruct the original semi-automatically delineated GTVs into a reduced model containing only time trends. Reduced models were compared to the original GTVs by analyzing the reconstruction error in the GTV and position. Both retrospective (all weekly images) and prospective (only the first four weekly images) were evaluated. The average volume difference from the original GTV was 4.3% ± 2.4% for the trending model. The positional variability of the GTV over the treatment course, as measured by the standard deviation of the GTV centroid, was 1.9 ± 1.4 mm for the original GTVs, which was reduced to 1.2 ± 0.6 mm for the trending-only model. In 3/13 cases, the dominant eigenmode changed class between the prospective and retrospective models. The trending-only model preserved GTV and shape relative to the original GTVs, while reducing spurious positional variability. The classification scheme appears feasible for separating types of geometric variability by time trend.