Ahmed M. Badawi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ahmed M. Badawi has a total of 71 co-authors. Here are the top co-authors by number of shared publications:
E Weiss
Virginia Commonwealth University, Richmond, VA
4 shared publicationsG Hugo
Virginia Commonwealth University, Richmond, VA
4 shared publicationsA Brown
Virginia Commonwealth University, Richmond, VA
3 shared publicationsA. Sebak
Electrical and Computer Engineering Dept., University of Manitoba, Winnipeg, Canada R3T 5V6
3 shared publicationsElisabeth Weiss
3 shared publications- Geoffrey D. Hugo
Department of Radiation Oncology, Virginia Commonwealth University, Richmond, Virginia
3 shared publications
Latest Publications
- Open Access
- 13 June 2025
- Published by Springer Nature in Neural Computing and Applications
- Vol. 37 (22) , 18275-18301
Gender classification using dorsal NIR hand veins imaging
Gender classification is soft biometric trait that can be used for identification, surveillance, databases-indexing, social/medical services, forensic anthropology, and e-marketing. Gender classification has been addressed with face, iris, fingerprints, hand veins of fingers/palm, and hand geometry. The hand has several biometric modalities such as dorsal and palmar hand veins, fingers veins, hand geometry, and fingerprints. Near-infrared dorsal hand veins were not addressed for gender classification. They are hidden under skin and very hard to fake unlike face and fingerprints. They can be imaged using cheap cameras. In this paper, we acquired novel multimodal dataset for 200 subjects, for the purpose of gender classification. The acquired near-infrared image modalities include dorsal hand veins in fisted and landed with wrist positions and hand geometry. At least 5 images per each hand were acquired over several sessions. We also acquired 7 facial expressions and side-view color images. Image enhancements, region of interest extraction, texture mapping, and data augmentation have been proposed. Sixty-three individual convolutional neural networks models were proposed, trained, validated, and tested, to classify gender from twenty-one hand veins image modalities, and for three split ratios. Highest obtained testing accuracy for all individual models is 96.97% with fivefold cross-validation mean value of 95.33%. Higher accuracies were found for females and for left hands as 98.73% and 97.35%. Individual model's classifier probability scores were fused, and fusion accuracies are over 99% for some fusion rules. Superior performance accuracies highlight the potential of our proposed gender classification system for biometric applications, particularly where gender classification accuracy is crucial.
- 13 June 2025
- Published by Springer Nature in Neural Computing and Applications
- Vol. 37 (22) , 18275-18301
Open AccessGender classification using dorsal NIR hand veins imaging
Gender classification is soft biometric trait that can be used for identification, surveillance, databases-indexing, social/medical services, forensic anthropology, and e-marketing. Gender classification has been addressed with face, iris, fingerprints, hand veins of fingers/palm, and hand geometry. The hand has several biometric modalities such as dorsal and palmar hand veins, fingers veins, hand geometry, and fingerprints. Near-infrared dorsal hand veins were not addressed for gender classification. They are hidden under skin and very hard to fake unlike face and fingerprints. They can be imaged using cheap cameras. In this paper, we acquired novel multimodal dataset for 200 subjects, for the purpose of gender classification. The acquired near-infrared image modalities include dorsal hand veins in fisted and landed with wrist positions and hand geometry. At least 5 images per each hand were acquired over several sessions. We also acquired 7 facial expressions and side-view color images. Image enhancements, region of interest extraction, texture mapping, and data augmentation have been proposed. Sixty-three individual convolutional neural networks models were proposed, trained, validated, and tested, to classify gender from twenty-one hand veins image modalities, and for three split ratios. Highest obtained testing accuracy for all individual models is 96.97% with fivefold cross-validation mean value of 95.33%. Higher accuracies were found for females and for left hands as 98.73% and 97.35%. Individual model's classifier probability scores were fused, and fusion accuracies are over 99% for some fusion rules. Superior performance accuracies highlight the potential of our proposed gender classification system for biometric applications, particularly where gender classification accuracy is crucial.
- 19 July 2023
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 90 (5) , 2158-2174
Eddy currents analysis methods for an MRI longitudinal gradient coil
Purpose: The rapid switching of the gradient fields induces eddy currents in neighboring metallic structures, causing undesirable effects. Numerical computations are thus required to understand eddy‐currents effects for designing/implementing mitigation (involving passive shielding) and compensating techniques (using pre‐emphasis). Previously, the network‐analysis (NA) method was introduced to compute z‐gradient eddy currents, although limited to a circularly symmetric and unconnected coil. Multi‐layer integral method (MIM) method was recently introduced, modifying the circuit equation involving stream functions. We tailor MIM (TMIM) for a more general eddy‐currents analysis in thin structures. Z‐gradient eddy currents are analyzed and then compared using three methods (NA, TMIM, and Ansys). The analysis helps to evaluate the efficiency of passive shielding and to compensate eddy currents.Methods: NA and TMIM computational frameworks for harmonic and transient eddy‐currents analysis were implemented and cross‐validated against Ansys Maxwell. A pre‐emphasis pulse was modeled for compensating eddy currents.Results: Eddy‐currents analysis of an unconnected z‐gradient coil in both the passive shield and cryostat were computed, and results were comparable to the least computationally efficient Ansys simulations. Although NA computations are fast, TMIM is implemented with reasonable efficiency and applied to circularly unsymmetric geometries. TMIM computations were further validated against Ansys using a connected z‐gradient. Our computations allowed the effective evaluation of the performance of three various passive‐shielding configurations, non‐capped, capped, and slitted (for the first time), and an effective pre‐emphasis compensation model was computed.Conclusion: Three eddy‐currents analysis methods were studied and compared. Computationally efficient TMIM allows both harmonic and transient eddy‐currents analysis involving different/complex gradient configurations/situations as well as involved shielding structures. Eddy‐currents pre‐emphasis compensation was demonstrated.
- 19 July 2023
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 90 (5) , 2158-2174
Eddy currents analysis methods for an MRI longitudinal gradient coil
Purpose: The rapid switching of the gradient fields induces eddy currents in neighboring metallic structures, causing undesirable effects. Numerical computations are thus required to understand eddy‐currents effects for designing/implementing mitigation (involving passive shielding) and compensating techniques (using pre‐emphasis). Previously, the network‐analysis (NA) method was introduced to compute z‐gradient eddy currents, although limited to a circularly symmetric and unconnected coil. Multi‐layer integral method (MIM) method was recently introduced, modifying the circuit equation involving stream functions. We tailor MIM (TMIM) for a more general eddy‐currents analysis in thin structures. Z‐gradient eddy currents are analyzed and then compared using three methods (NA, TMIM, and Ansys). The analysis helps to evaluate the efficiency of passive shielding and to compensate eddy currents.Methods: NA and TMIM computational frameworks for harmonic and transient eddy‐currents analysis were implemented and cross‐validated against Ansys Maxwell. A pre‐emphasis pulse was modeled for compensating eddy currents.Results: Eddy‐currents analysis of an unconnected z‐gradient coil in both the passive shield and cryostat were computed, and results were comparable to the least computationally efficient Ansys simulations. Although NA computations are fast, TMIM is implemented with reasonable efficiency and applied to circularly unsymmetric geometries. TMIM computations were further validated against Ansys using a connected z‐gradient. Our computations allowed the effective evaluation of the performance of three various passive‐shielding configurations, non‐capped, capped, and slitted (for the first time), and an effective pre‐emphasis compensation model was computed.Conclusion: Three eddy‐currents analysis methods were studied and compared. Computationally efficient TMIM allows both harmonic and transient eddy‐currents analysis involving different/complex gradient configurations/situations as well as involved shielding structures. Eddy‐currents pre‐emphasis compensation was demonstrated.
- Open Access
- 26 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 103840-103851
Multi-Channel, Actively Shielded, Power Efficient MRI Z-Gradient Cylindrical Coil Design Using Target-Field Method
Gradient coils are essential for MRI where fast and large electrical current pulses are typically applied to conventional, single-channel gradient coils, particularly for high-performance gradient applications. However, these pulses result in significant power losses and heating of the coil. We investigate the design of power-efficient multi-channel Z-gradient coils operating in the conventional mode comparing them to conventional single-channel coils designed using similar dimensions and alike DC performance characteristics. The power-efficiencies of thirteen different two-channel configurations having various section lengths for two different dimensions are analyzed. The current density of each section is approximated by Fourier series expansion where a linear equation relating the desired target field and current density is formulated and then solved. A stream function is derived from the obtained current density and then used to extract the final winding patterns of each section using a particular track width and a specific number of turns. The design process involves optimizing the current driving each channel, the distribution of coil windings, and the section size. Similarly, the performance of three-channel coils is also investigated. Results show that a power dissipation reduction of 17-28% and ~23% can be achieved using two- and three-channel coils, respectively. Moreover, we showed that multi-channel coils may have a slightly better shielding efficiency compared to conventional coils. A new methodology for designing two- and three-channel coils is presented where an advantage in terms of power efficiency can be gained depending on design parameters, coil’s dimensions, number of turns, and other metrics.
- 26 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 103840-103851
Open AccessMulti-Channel, Actively Shielded, Power Efficient MRI Z-Gradient Cylindrical Coil Design Using Target-Field Method
Gradient coils are essential for MRI where fast and large electrical current pulses are typically applied to conventional, single-channel gradient coils, particularly for high-performance gradient applications. However, these pulses result in significant power losses and heating of the coil. We investigate the design of power-efficient multi-channel Z-gradient coils operating in the conventional mode comparing them to conventional single-channel coils designed using similar dimensions and alike DC performance characteristics. The power-efficiencies of thirteen different two-channel configurations having various section lengths for two different dimensions are analyzed. The current density of each section is approximated by Fourier series expansion where a linear equation relating the desired target field and current density is formulated and then solved. A stream function is derived from the obtained current density and then used to extract the final winding patterns of each section using a particular track width and a specific number of turns. The design process involves optimizing the current driving each channel, the distribution of coil windings, and the section size. Similarly, the performance of three-channel coils is also investigated. Results show that a power dissipation reduction of 17-28% and ~23% can be achieved using two- and three-channel coils, respectively. Moreover, we showed that multi-channel coils may have a slightly better shielding efficiency compared to conventional coils. A new methodology for designing two- and three-channel coils is presented where an advantage in terms of power efficiency can be gained depending on design parameters, coil’s dimensions, number of turns, and other metrics.
- 1 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 114-117
Improved Anomaly Detection in Low-Resolution and Noisy Whole-Slide Images using Transfer Learning
Whole-slide imaging (WSI) is one of the most recent technologies introduced in medical pathology practices. WSI images are created using a computerized system that scans, stitches and stores pathology specimen glass slides into digital images, which provide a multi-resolution pyramid construction of a huge gigabyte size due to the need for containing a high amount of tissue details. Therefore, digital WSI brings major challenges in data storage, image analysis and transmission (e.g. telepathology and interoperability). In this paper, we propose a computer-aided diagnosis (CAD) system to detect cancer anomalies in breast lymph node WSI images under low-resolution (LR) and noise conditions. In particular, we investigate a transfer-learning approach to find the scale mappings between WSI levels using partial least-square (PLS) regression. The learned scale mappings can be used to detect anomalies in LR images and hence reduce the computational cost of anomaly detection. Then, we explore the effect of different levels of noise on detection performance. We simulated different scenarios where WSI images are contaminated with Gaussian noise and several de-noising algorithms were applied, namely de-noising with PLS, Block Matching $3D (BM3D)$ and the combination of PLS and BM3D. We show that these de-noising algorithms can help reduce the noise severity on anomaly detection. For example, for noisy images with 0.8 noise standard deviation, these three algorithms improved the LR detection accuracy from 63.50% to 93.81%, 92.73%, and 97.51%, respectively. Our results lead to useful conclusions on how to handle whole slide images under scaling and noise conditions.- 1 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 114-117
Improved Anomaly Detection in Low-Resolution and Noisy Whole-Slide Images using Transfer Learning
Whole-slide imaging (WSI) is one of the most recent technologies introduced in medical pathology practices. WSI images are created using a computerized system that scans, stitches and stores pathology specimen glass slides into digital images, which provide a multi-resolution pyramid construction of a huge gigabyte size due to the need for containing a high amount of tissue details. Therefore, digital WSI brings major challenges in data storage, image analysis and transmission (e.g. telepathology and interoperability). In this paper, we propose a computer-aided diagnosis (CAD) system to detect cancer anomalies in breast lymph node WSI images under low-resolution (LR) and noise conditions. In particular, we investigate a transfer-learning approach to find the scale mappings between WSI levels using partial least-square (PLS) regression. The learned scale mappings can be used to detect anomalies in LR images and hence reduce the computational cost of anomaly detection. Then, we explore the effect of different levels of noise on detection performance. We simulated different scenarios where WSI images are contaminated with Gaussian noise and several de-noising algorithms were applied, namely de-noising with PLS, Block Matching $3D (BM3D)$ and the combination of PLS and BM3D. We show that these de-noising algorithms can help reduce the noise severity on anomaly detection. For example, for noisy images with 0.8 noise standard deviation, these three algorithms improved the LR detection accuracy from 63.50% to 93.81%, 92.73%, and 97.51%, respectively. Our results lead to useful conclusions on how to handle whole slide images under scaling and noise conditions.- 13 February 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 257-260
Radiation susceptibility modeling of passive PCBs using the complex images method
We have presented the usage of a full-wave electromagnetic numerical analysis tool to study radiation susceptibility of passive PCBs. The numerical tool uses a mixed potential integral equation combined with the efficient and accurate CIM. The MoM solution adopted is particularly efficient for analyzing radiation susceptibility, since the impedance matrix associated with the PCB does not have to be recalculated for different orientation or polarization of the incident field. Although the shown results are preliminary, the potential for using the tool towards more elaborate geometries and magnitudes of the incident fields is shown. Further results will be incorporated in the presentation.
- 13 February 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 257-260
Radiation susceptibility modeling of passive PCBs using the complex images method
We have presented the usage of a full-wave electromagnetic numerical analysis tool to study radiation susceptibility of passive PCBs. The numerical tool uses a mixed potential integral equation combined with the efficient and accurate CIM. The MoM solution adopted is particularly efficient for analyzing radiation susceptibility, since the impedance matrix associated with the PCB does not have to be recalculated for different orientation or polarization of the incident field. Although the shown results are preliminary, the potential for using the tool towards more elaborate geometries and magnitudes of the incident fields is shown. Further results will be incorporated in the presentation.
- 26 August 2015
- Published by Springer Nature
- p. 737-748
Adaptive Saliency-Weighted 2D-to-3D Video Conversion
- 26 August 2015
- Published by Springer Nature
- p. 737-748
Adaptive Saliency-Weighted 2D-to-3D Video Conversion
- 29 May 2014
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9075, 907506
Multimodal biometrics system based on face profile and ear
Face recognition from a side profile view, has recently received significant attention in the literature. Even though current face recognition systems have reached a certain level of maturity at angles up to 30 degrees, their success is still limited with side profile angles. This paper presents an efficient technique for the fusion of face profile and ear biometrics. We propose to use a Block-based Local Binary Pattern (LBP) to generate the features for recognition from face profile images and ear images. These feature distributions are then fused at the score level using simple mean rule. Experimental results show that the proposed multimodal system can achieve 97:98% recognition performance, compared to unimodal biometrics of face profile 96.76%, and unimodal biometrics of ear 96.95%, details in the Experimental Results Section. Comparisons with other multimodal systems used in the literature, like Principal Component Analysis (PCA), Full-space Linear Discriminant Analysis (FSLDA) and Kernel Fisher discriminant analysis (KFDA), are presented in the Experimental Results Section.
- 29 May 2014
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9075, 907506
Multimodal biometrics system based on face profile and ear
Face recognition from a side profile view, has recently received significant attention in the literature. Even though current face recognition systems have reached a certain level of maturity at angles up to 30 degrees, their success is still limited with side profile angles. This paper presents an efficient technique for the fusion of face profile and ear biometrics. We propose to use a Block-based Local Binary Pattern (LBP) to generate the features for recognition from face profile images and ear images. These feature distributions are then fused at the score level using simple mean rule. Experimental results show that the proposed multimodal system can achieve 97:98% recognition performance, compared to unimodal biometrics of face profile 96.76%, and unimodal biometrics of ear 96.95%, details in the Experimental Results Section. Comparisons with other multimodal systems used in the literature, like Principal Component Analysis (PCA), Full-space Linear Discriminant Analysis (FSLDA) and Kernel Fisher discriminant analysis (KFDA), are presented in the Experimental Results Section.
- 15 December 2011
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 57 (2) , 395-413
Classifying geometric variability by dominant eigenmodes of deformation in regressing tumours during active breath-hold lung cancer radiotherapy
The purpose of this study is to develop and evaluate a lung tumour interfraction geometric variability classification scheme as a means to guide adaptive radiotherapy and improve measurement of treatment response. Principal component analysis (PCA) was used to generate statistical shape models of the gross tumour volume (GTV) for 12 patients with weekly breath hold CT scans. Each eigenmode of the PCA model was classified as 'trending' or 'non-trending' depending on whether its contribution to the overall GTV variability included a time trend over the treatment course. Trending eigenmodes were used to reconstruct the original semi-automatically delineated GTVs into a reduced model containing only time trends. Reduced models were compared to the original GTVs by analyzing the reconstruction error in the GTV and position. Both retrospective (all weekly images) and prospective (only the first four weekly images) were evaluated. The average volume difference from the original GTV was 4.3% ± 2.4% for the trending model. The positional variability of the GTV over the treatment course, as measured by the standard deviation of the GTV centroid, was 1.9 ± 1.4 mm for the original GTVs, which was reduced to 1.2 ± 0.6 mm for the trending-only model. In 3/13 cases, the dominant eigenmode changed class between the prospective and retrospective models. The trending-only model preserved GTV and shape relative to the original GTVs, while reducing spurious positional variability. The classification scheme appears feasible for separating types of geometric variability by time trend.
- 15 December 2011
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 57 (2) , 395-413
Classifying geometric variability by dominant eigenmodes of deformation in regressing tumours during active breath-hold lung cancer radiotherapy
The purpose of this study is to develop and evaluate a lung tumour interfraction geometric variability classification scheme as a means to guide adaptive radiotherapy and improve measurement of treatment response. Principal component analysis (PCA) was used to generate statistical shape models of the gross tumour volume (GTV) for 12 patients with weekly breath hold CT scans. Each eigenmode of the PCA model was classified as 'trending' or 'non-trending' depending on whether its contribution to the overall GTV variability included a time trend over the treatment course. Trending eigenmodes were used to reconstruct the original semi-automatically delineated GTVs into a reduced model containing only time trends. Reduced models were compared to the original GTVs by analyzing the reconstruction error in the GTV and position. Both retrospective (all weekly images) and prospective (only the first four weekly images) were evaluated. The average volume difference from the original GTV was 4.3% ± 2.4% for the trending model. The positional variability of the GTV over the treatment course, as measured by the standard deviation of the GTV centroid, was 1.9 ± 1.4 mm for the original GTVs, which was reduced to 1.2 ± 0.6 mm for the trending-only model. In 3/13 cases, the dominant eigenmode changed class between the prospective and retrospective models. The trending-only model preserved GTV and shape relative to the original GTVs, while reducing spurious positional variability. The classification scheme appears feasible for separating types of geometric variability by time trend.
- 1 October 2011
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 81 (2) , 560-567
Localization Accuracy of the Clinical Target Volume During Image-Guided Radiotherapy of Lung Cancer
- 1 October 2011
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 81 (2) , 560-567
Localization Accuracy of the Clinical Target Volume During Image-Guided Radiotherapy of Lung Cancer
- 1 June 2011
- Published by Wiley in Medical Physics
- Vol. 38 (6) , 3845-3846
TH-A-220-02: Improving Localization of Lung Cancer Targets for Radiotherapy Using Semi-Deformable Featurelet Registration
- 1 June 2011
- Published by Wiley in Medical Physics
- Vol. 38 (6) , 3845-3846
TH-A-220-02: Improving Localization of Lung Cancer Targets for Radiotherapy Using Semi-Deformable Featurelet Registration