DADavid J. Apple

David J. Apple

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


David J. Apple has a total of 46 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • The Role of the Soemmerring's Ring in the Pathogenesis of Post-Capsule Opacification and other Post-Surgical Opacifications

    by Dj Apple, Af Borkenstein, G Kleinmann, B Zuagg, G Auffarth

    Purpose: In this study we test the hypothesis that the Soemmerring's Ring (SR)is the structure of origin of multiple conditions ranging from simple PCO to capsular phimosis, with many in between. Methods: We examined the anterior segment structures of eyes that have had previous cataract surgery with special reference to a tracing of cells from the region of the peripheral lens to the point within the eye where they settle. Results: Examination of the capsular bags of 500 eyes revealed 3 levels of intracapsular LEC activity after ECCE. Conclusions: -The degree of cell proliferation in the capsular bags was higher than expected. (LECs and SR).-To date there are no surgical means to remove 100% of LECs! -A Soemmerring's Ring, the precursor of PCO and all other forms of post-surgical fibrosis of phakic and specialized IOLs occurs in 100% of cases after 5 to 7 years. -All IOL models are susceptible to a breakout of cells from the Soemmerring's Ring after ca. 5–7 years. -Up to 50% of cases have this breakout.

  • Pathology of Cataract Surgery and Intraocular Lenses

    by Liliana Werner, David J. Apple, Nick Mamalis


    • 1 June 2004
      • Vol. 52  (2) , 99-112

    Posterior capsule opacification: a review of the aetiopathogenesis, experimental and clinical studies and factors for prevention.

    by Suresh K Pandey, David J Apple, Liliana Werner, Anthony J Maloof, E John Milverton

    Posterior capsule opacification (PCO, secondary cataract, after cataract) is a nagging postsurgical complication following extracapsular cataract surgery (ECCE) and intraocular lens (IOL) implantation. PCO should be eliminated since it has deleterious sequelae and Neodynium: Yttrium Aluminium Garnet (Nd: YAG) laser treatment often is an unnecessary financial burden on the health care system. PCO following cataract surgery could be a major problem, since patient follow-up is difficult and the Nd:YAG laser is not always available. Advances in surgical techniques, IOL designs/biomaterials have been instrumental in bringing about a gradual and unnoticed decrease in the incidence of PCO. We strongly believe that the overall incidence of PCO and hence the incidence of Nd:YAG laser posterior capsulotomy is now rapidly decreasing - from 50% in the 1980s and early 1990s to less than 10% currently. Superior tools, surgical procedures, skills and appropriate IOL designs have all helped to significantly reduce this complication. In this article, we review the aetio pathogenesis, experimental and clinical studies and propose surgical and implant-related factors for PCO prevention. Careful application and utilisation of these factors by surgeons could lead to a significant reduction is secondary cataract, the second most common cause of visual loss worldwide.


  • Deposits in artificial corneas: risk factors and prevention

    by Celia R Hicks, Traian V Chirila, Liliana Werner, Geoffrey J Crawford, David J Apple, Ian J Constable

    Purpose: To identify risk factors for calcium deposition and pigmented staining within AlphaCor artificial corneas. Methods: Retrospective analysis of data from 72 AlphaCor implantations was conducted. Histological analysis of explants was performed. Results: Eight cases of either intraoptic calcium or pigment deposition occurred in AlphaCor patients between 2.5 and 21 months after implantation. Four cases had diffuse white deposits, confirmed to be calcium and associated with prior coadministration of topical steroids and beta-blockers. The other four cases had brown deposits, associated with cigarette smoking and topical levobunolol. Conclusion: These findings led to changes in patient management protocols, surgeon training and patient information so as to minimize the risk of further occurrences. No further cases of white deposition have occurred after warning surgeons of the risk associated with certain topical therapy combinations. The risk of brown staining may be difficult to remove completely as it appears that environmental exposure to chemicals may cause deposition in addition to personal smoking habits and topical medications.


    • 1 September 2003
      • Vol. 51  (3) , 211-6

    Sir Nicholas Harold Ridley. He changed the world, so that we might better see it.

    by Rupal H Trivedi, David J Apple, Suresh K Pandey, Liliana Werner, Andrea M Izak, Abhay R Vasavada, Jagat Ram

    Cataract surgery with intraocular lens (IOL) implantation has become the most common and most successful of all operations in medicine. Sir Harold Ridley's first cataract extraction with implantation of an IOL marked the beginning of a major change in the practice of ophthalmology. Millions of patients worldwide have benefited from Sir Ridley's invention, and are likely to continue to derive benefit from this device. However, the development of the IOL was not without its share of ups and downs. Sir Harold Ridley, the inventor of IOL, died at the age of 94, on 25 May 2001, and ophthalmology lost one of its greatest and most influential practitioners. We are happy that he lived to enjoy the fruits of his labour--to see the amazing improvements and the expansive growth that evolved in the cataract-IOL technique, from early and unsatisfactory operations in previous decades, to the superb results attainable today. The invention of the IOL has not been just the addition of one new form of treatment, but rather, Sir Harold's tiny disc-shaped sliver of plastic has changed the world so that our patients may better see it. This article presents a brief biographical sketch of Sir Harold and lists his major inventions and contributions to ophthalmology.


  • Sir Nicholas Harold Ridley, Kt, MD, FRCS, FRS

    by David J. Apple, Rupal H. Trivedi

    Research from JAMA Ophthalmology — Sir Nicholas Harold Ridley, Kt, MD, FRCS, FRS — Contributions in Addition to the Intraocular Lens


  • Peripapillärer Tumor bei Autopsieaugen

    by David J. Apple, J.M. Schmidbauer, A. Golescu, L. G. Vargas, M. Escobar-Gomez

  • Trübung einer PMMA-Intraokularlinse

    by J.M. Schmidbauer, David J. Apple, Q. Peng, S. N. Arthur, L. G. Vargas


    • 1 March 2002
      • Vol. 50  (1) , 49-51

    Bipseudophakia. Clinicopathological findings of a pseudophakic human globe obtained postmortem implanted with an anterior chamber and a posterior chamber intraocular lens.

    by Andrea M Izak, Suresh K Pandey, Liliana Werner, David J Apple, Rupal H Trivedi

    We report the clinicopathological findings of a human pseudophakic globe obtained postmortem, containing both anterior and posterior chamber intraocular lens, a condition we termed "bipseudophakia".

  • Nachstarrate, Zentrierverhalten, Biokompatibilität und Fixation intraokularer Faltlinsen - eine Milleniums-Analyse 1221 pseudophaker Autopsieaugen12

    by Josef M. Schmidbauer, Luis G. Vargas, David J. Apple, Gerd U. Auffarth, Qun Peng, Stella N. Arthur, Marcela Escobar-Gomez

    Hintergrund Die fortlaufende Entwicklung von Faltlinsendesigns macht es erforderlich, die einzelnen Typen im Hinblick auf ihre unterschiedlichen Eigenschaften nach der Implantation zu untersuchen. Die über 16 500 Intraokularlinsen umfassende Datenbank unseres Labors, erlaubte eine klinisch-pathologische Analyse pseudophaker Autopsieaugen aus weltweiten Quellen, insbesondere aus den Lions-Hornhautbanken der USA.Material und Methode Sechs geläufige intraokulare Faltlinsendesigns und als Vergleichsgruppe, der Standard nicht faltbarer Linsentypen, das 1-piece-PMMA-Design, wurden in die Studie aufgenommen. Die Miyake-Apple-posteriore-Fototechnik erlaubte eine sichere Beurteilung des Grades der Nachstarbildung, des Zentrierverhaltens, der Haptikfixation und des Ausmaßes und Intensität der Soemmerring-Ring-Bildung.Ergebnisse Die vier Intraokularlinsen mit den niedrigsten Kapsulotomieraten (zwischen 3,8 % und 21,7 %) und Nachstarraten waren neuere Designs, die meist erst nach 1992 implantiert wurden. Höhere Nachstarraten zeigten die zwei älteren Linsentypen. Die Dezentrierungswerte und Nachstarraten waren am geringsten bei Kapselsackimplantation. Frühere Untersuchungen, wie auch die aktuelle Analyse zeigten, dass die AcrySof™-IOL die günstigsten Biokompatibilitätswerte aufwies.Schlussfolgerung Die Inzidenz der zwei Hauptkomplikationen der Hinterkammerlinsenimplantation, Dezentrierung und Nachstar ist zur Jahrtausendwende deutlich rückläufig. Background The ongoing and fast evolution of foldable IOL designs established the necessity to evaluate the different abilities of each lens style. The large IOL database (over 16,500 specimens) acquired in our laboratory, has permitted us to perform a clinico-pathological analysis on pseudophakic autopsy globes provided from sources worldwide, especially many Lions Eye banks in the United States.Material and methods We analyzed 6 foldable IOL styles commonly implanted in the United States, using one type of rigid IOL design (1-piece design rigid PMMA optics) as a comparison group. Posterior capsule opacification (PCO) score, decentration, fixation, presence or absence of a Nd:YAG laser posterior capsulotomy and area and intensity of Soemmerring's ring formation was discerned by examination under an operating microscope using the Miyake-Apple posterior photographic technique.Results The four lenses with the lowest rates ranging between 3.8 % and 21.7 % are modern designs, mostly implanted after 1992. The two lenses with the higher rates ranging between 23.1 % and 30.4 %, were all older designs, already prevalent prior to 1992. IOL fixation with both haptics in the capsular bag showed the best centration values and PCO scores. Our studies to date have shown in a preliminary fashion that the AcrySof™ IOL displays the the lowest (best) biocompatibility score.Conclusions Entering the new millenium, with evolution of modern surgical techniques and IOL designs, the incidence of the two major complications of cataract surgery, decentration and PCO are now finally diminishing. 1 Manuskript erstmalig eingereicht am 27. 5. 01 und in der vorliegenden Form angenommen. 2 Supported in part by an unrestricted grant from Research to Prevent Blindness, Inc., New York, NY and a Max Kade postdoctoral research grant (Schmidbauer), Max Kade Foundation, New York, NY.