Stephen Kadlecek
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Stephen Kadlecek has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Masaru Ishii
Department of Otolaryngology—Head and Neck Surgery, Johns Hopkins University School of Medicine, Baltimore, MD 21205, USA
3 shared publications - Rahim R. Rizi
Department of Radiology, University of Pennsylvania, Philadelphia, PA 19104, USA
3 shared publications Rahim Rizi
Department of Radiology University of Pennsylvania Philadelphia PA USA
3 shared publications- Kiarash Emami
Department of Radiology, University of Pennsylvania, Philadelphia, PA 19104, USA
2 shared publications - Sarmad Siddiqui
Department of Radiology, University of Pennsylvania, Philadelphia, USA
2 shared publications - Anthony Mancuso
Abramson Cancer Center, University of Pennsylvania, Philadelphia, PA 19104, USA
1 shared publication
Latest Publications
- Open Access
- 26 August 2021
- Published by MDPI AG in Metabolites
- Vol. 11 (9) , 576
Radial Flow Perfusion Enables Real-Time Profiling of Cellular Metabolism at Low Oxygen Levels with Hyperpolarized 13C NMR Spectroscopy
In this study, we describe new methods for studying cancer cell metabolism with hyperpolarized 13C magnetic resonance spectroscopy (HP 13C MRS) that will enable quantitative studies at low oxygen concentrations. Cultured hepatocellular carcinoma cells were grown on the surfaces of non-porous microcarriers inside an NMR spectrometer. They were perfused radially from a central distributer in a modified NMR tube (bioreactor). The oxygen level of the perfusate was continuously monitored and controlled externally. Hyperpolarized substrates were injected continuously into the perfusate stream with a newly designed system that prevented oxygen and temperature perturbations in the bioreactor. Computational and experimental results demonstrated that cell mass oxygen profiles with radial flow were much more uniform than with conventional axial flow. Further, the metabolism of HP [1-13C]pyruvate was markedly different between the two flow configurations, demonstrating the importance of avoiding large oxygen gradients in cell perfusion experiments.
- 26 August 2021
- Published by MDPI AG in Metabolites
- Vol. 11 (9) , 576
Open AccessRadial Flow Perfusion Enables Real-Time Profiling of Cellular Metabolism at Low Oxygen Levels with Hyperpolarized 13C NMR Spectroscopy
In this study, we describe new methods for studying cancer cell metabolism with hyperpolarized 13C magnetic resonance spectroscopy (HP 13C MRS) that will enable quantitative studies at low oxygen concentrations. Cultured hepatocellular carcinoma cells were grown on the surfaces of non-porous microcarriers inside an NMR spectrometer. They were perfused radially from a central distributer in a modified NMR tube (bioreactor). The oxygen level of the perfusate was continuously monitored and controlled externally. Hyperpolarized substrates were injected continuously into the perfusate stream with a newly designed system that prevented oxygen and temperature perturbations in the bioreactor. Computational and experimental results demonstrated that cell mass oxygen profiles with radial flow were much more uniform than with conventional axial flow. Further, the metabolism of HP [1-13C]pyruvate was markedly different between the two flow configurations, demonstrating the importance of avoiding large oxygen gradients in cell perfusion experiments.
- 20 October 2014
- Published by Wiley in NMR in Biomedicine
- Vol. 27 (12) , 1557-1570
The effect of exogenous substrate concentrations on true and apparent metabolism of hyperpolarized pyruvate in the isolated perfused lung
Although relatively metabolically inactive, the lung has an important role in maintaining systemic glycolytic intermediate and cytosolic redox balance. Failure to perform this function appropriately may lead to lung disease progression, including systemic aspects of these disorders. In this study, we experimentally probe the response of the isolated, perfused organ to varying glycolytic intermediate (pyruvate and lactate) concentrations, and the effect on the apparent metabolism of hyperpolarized 1‐13C pyruvate. Twenty‐four separate conditions were studied, from sub‐physiological to super‐physiological concentrations of each metabolite. A three‐compartment model is developed, which accurately matches the full range of experiments and includes a full account of evolution of agent concentration and polarization. The model is then refined using a series of approximations which are shown to be applicable to cases of physiological relevance, and which facilitate an intuitive understanding of the saturation and scaling behavior. Perturbations of the model assumptions are used to determine the sensitivity to input parameter estimates, and finally the model is used to examine the relationship between measurements accessible by NMR and the underlying physiological parameters of interest. Based on the observed scaling of lactate labeling with lactate and pyruvate concentrations, we conclude that the level of hyperpolarized lactate signal in the lung is primarily determined by the rate at which NAD+ is reduced to NADH. Further, although weak dependences on other factors are predicted, the modeled NAD+ reduction rate is largely governed by the intracellular lactate pool size. Conditions affecting the lactate pool can therefore be expected to display the highest contrast in hyperpolarized 13C‐pyruvate imaging. The work is intended to serve as a basis both to interpret the signal dynamics of hyperpolarized measurements in the normal lung and to understand the cause of alterations seen in a variety of disease and exposure models. Copyright © 2014 John Wiley & Sons, Ltd.
- 20 October 2014
- Published by Wiley in NMR in Biomedicine
- Vol. 27 (12) , 1557-1570
The effect of exogenous substrate concentrations on true and apparent metabolism of hyperpolarized pyruvate in the isolated perfused lung
Although relatively metabolically inactive, the lung has an important role in maintaining systemic glycolytic intermediate and cytosolic redox balance. Failure to perform this function appropriately may lead to lung disease progression, including systemic aspects of these disorders. In this study, we experimentally probe the response of the isolated, perfused organ to varying glycolytic intermediate (pyruvate and lactate) concentrations, and the effect on the apparent metabolism of hyperpolarized 1‐13C pyruvate. Twenty‐four separate conditions were studied, from sub‐physiological to super‐physiological concentrations of each metabolite. A three‐compartment model is developed, which accurately matches the full range of experiments and includes a full account of evolution of agent concentration and polarization. The model is then refined using a series of approximations which are shown to be applicable to cases of physiological relevance, and which facilitate an intuitive understanding of the saturation and scaling behavior. Perturbations of the model assumptions are used to determine the sensitivity to input parameter estimates, and finally the model is used to examine the relationship between measurements accessible by NMR and the underlying physiological parameters of interest. Based on the observed scaling of lactate labeling with lactate and pyruvate concentrations, we conclude that the level of hyperpolarized lactate signal in the lung is primarily determined by the rate at which NAD+ is reduced to NADH. Further, although weak dependences on other factors are predicted, the modeled NAD+ reduction rate is largely governed by the intracellular lactate pool size. Conditions affecting the lactate pool can therefore be expected to display the highest contrast in hyperpolarized 13C‐pyruvate imaging. The work is intended to serve as a basis both to interpret the signal dynamics of hyperpolarized measurements in the normal lung and to understand the cause of alterations seen in a variety of disease and exposure models. Copyright © 2014 John Wiley & Sons, Ltd.
- 31 October 2013
- Published by Elsevier in Academic Radiology
- Vol. 20 (10) , 1224-1233
Regional Alveolar Partial Pressure of Oxygen Measurement with Parallel Accelerated Hyperpolarized Gas MRI
- 31 October 2013
- Published by Elsevier in Academic Radiology
- Vol. 20 (10) , 1224-1233
Regional Alveolar Partial Pressure of Oxygen Measurement with Parallel Accelerated Hyperpolarized Gas MRI
- 7 February 2012
- Published by Wiley in NMR in Biomedicine
- Vol. 25 (10) , 1113-1118
Metabolism of hyperpolarized [1‐13C]pyruvate in the isolated perfused rat lung – an ischemia study
We report studies of the effect of ischemia on the metabolic activity of the intact perfused lung and its restoration after a period of reperfusion. Two groups of rat lungs were studied using hyperpolarized 1‐13C pyruvate to compare the rate of lactate labeling differing only in the temporal ordering of ischemic and normoxic acquisitions. In both cases, a several‐fold increase in lactate labeling was observed immediately after a 25‐min ischemia event as was its reversal back to the baseline after 30–40 min of resumed perfusion (n = 5, p < 0.025 for both comparisons). These results were corroborated by 31P spectroscopy and correspond well to measured changes in lactate pool size determined by 1H spectroscopy of freeze‐clamped specimens. Copyright © 2012 John Wiley & Sons, Ltd.
- 7 February 2012
- Published by Wiley in NMR in Biomedicine
- Vol. 25 (10) , 1113-1118
Metabolism of hyperpolarized [1‐13C]pyruvate in the isolated perfused rat lung – an ischemia study
We report studies of the effect of ischemia on the metabolic activity of the intact perfused lung and its restoration after a period of reperfusion. Two groups of rat lungs were studied using hyperpolarized 1‐13C pyruvate to compare the rate of lactate labeling differing only in the temporal ordering of ischemic and normoxic acquisitions. In both cases, a several‐fold increase in lactate labeling was observed immediately after a 25‐min ischemia event as was its reversal back to the baseline after 30–40 min of resumed perfusion (n = 5, p < 0.025 for both comparisons). These results were corroborated by 31P spectroscopy and correspond well to measured changes in lactate pool size determined by 1H spectroscopy of freeze‐clamped specimens. Copyright © 2012 John Wiley & Sons, Ltd.
- 15 August 2011
- Published by Wiley in NMR in Biomedicine
- Vol. 24 (8) , 933-942
A simple and low‐cost device for generating hyperpolarized contrast agents using parahydrogen
A detailed description of the construction and use of a device for hyperpolarization of select contrast agents is presented. The device is based on molecular incorporation of the spin‐order inherent to parahydrogen, followed by order transfer to a metastable heteronuclear alignment. Design considerations and experimental results relating to catalyst/solvent choice and handling, solvent heating, efficient gas entrainment and spin‐order transfer are described. The resulting degree of hyperpolarization is shown to be substantial, ranging from a few to over 50%, depending on the choice of target molecule. Finally, the use of the hyperpolarized agent is demonstrated in a series of in vivo images. Copyright © 2011 John Wiley & Sons, Ltd.
- 15 August 2011
- Published by Wiley in NMR in Biomedicine
- Vol. 24 (8) , 933-942
A simple and low‐cost device for generating hyperpolarized contrast agents using parahydrogen
A detailed description of the construction and use of a device for hyperpolarization of select contrast agents is presented. The device is based on molecular incorporation of the spin‐order inherent to parahydrogen, followed by order transfer to a metastable heteronuclear alignment. Design considerations and experimental results relating to catalyst/solvent choice and handling, solvent heating, efficient gas entrainment and spin‐order transfer are described. The resulting degree of hyperpolarization is shown to be substantial, ranging from a few to over 50%, depending on the choice of target molecule. Finally, the use of the hyperpolarized agent is demonstrated in a series of in vivo images. Copyright © 2011 John Wiley & Sons, Ltd.
- 8 March 2011
- Published by Wiley in NMR in Biomedicine
- Vol. 24 (10) , 1253-1263
Regional determination of oxygen uptake in rodent lungs using hyperpolarized gas and an analytical treatment of intrapulmonary gas redistribution
A method is presented which allows for the accurate extraction of regional functional metrics in rodent lungs using hyperpolarized gas. The technique is based on the combination of measured T1 decay, an independent measure of specific ventilation and mass balance considerations to extract the regional oxygen levels and uptake. In phantom and animal experiments, it is demonstrated that the redistribution of gas during the measurement is a significant confounding factor, and this effect is addressed analytically. The resulting parameterization of gas flow increases the accuracy of oxygen‐sensitive MRI, and may also be used independently to assess air trapping and airway constriction. Limitations of the technique with respect to spatial resolution and robustness are also discussed. Copyright © 2011 John Wiley & Sons, Ltd.
- 8 March 2011
- Published by Wiley in NMR in Biomedicine
- Vol. 24 (10) , 1253-1263
Regional determination of oxygen uptake in rodent lungs using hyperpolarized gas and an analytical treatment of intrapulmonary gas redistribution
A method is presented which allows for the accurate extraction of regional functional metrics in rodent lungs using hyperpolarized gas. The technique is based on the combination of measured T1 decay, an independent measure of specific ventilation and mass balance considerations to extract the regional oxygen levels and uptake. In phantom and animal experiments, it is demonstrated that the redistribution of gas during the measurement is a significant confounding factor, and this effect is addressed analytically. The resulting parameterization of gas flow increases the accuracy of oxygen‐sensitive MRI, and may also be used independently to assess air trapping and airway constriction. Limitations of the technique with respect to spatial resolution and robustness are also discussed. Copyright © 2011 John Wiley & Sons, Ltd.
- 1 July 2010
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 205 (1) , 9-13
Optimal transfer of spin-order between a singlet nuclear pair and a heteronucleus
- 1 July 2010
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 205 (1) , 9-13
Optimal transfer of spin-order between a singlet nuclear pair and a heteronucleus