Oleg Makarov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Oleg Makarov has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Mark Hilgart
GM/CA CAT at the APS, Biosciences Division, Argonne National Laboratory, Argonne, IL 60439, USA
2 shared publications C. Cork
Physical Biosciences Division, Lawrence Berkeley National Laboratory, Berkeley, CA 94720, USA
1 shared publicationC. Ogata
GM/CA-CAT, Biosciences Division, Argonne National Laboratory, Argonne, IL 60439, USA
1 shared publication- David J. Kissick
Advanced Photon Source, Argonne National Laboratory, 9700 South Cass Avenue, Bldg. 436D, Argonne, IL 60439, USA
1 shared publication - Janet L. Smith
Life Sciences Institute, University of Michigan, Ann Arbor, USA
1 shared publication - Michael Becker
Advanced Photon Source, Argonne National Laboratory, 9700 South Cass Avenue, Bldg. 436D, Argonne, IL 60439, USA
1 shared publication
Latest Publications
- Open Access
- 15 February 2022
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 29 (2) , 393-399
Fast automated energy changes at synchrotron radiation beamlines equipped with transfocator or focusing mirrors
Algorithms and procedures to fully automate retuning of synchrotron radiation beamlines over wide energy ranges are discussed. The discussion is based on the implementation at the National Institute of General Medical Sciences and the National Cancer Institute Structural Biology Facility at the Advanced Photon Source. When a user selects a new beamline energy, software synchronously controls the beamline monochromator and undulator to maintain the X-ray beam flux after the monochromator, preserves beam attenuation by determining a new set of attenuator foils, changes, as needed, mirror reflecting stripes and the undulator harmonic, preserves beam focal distance of compound refractive lens focusing by changing the In/Out combination of lenses in the transfocator, and, finally, restores beam position at the sample by on-the-fly scanning of either the Kirkpatrick–Baez mirror angles or the transfocator up/down and inboard/outboard positions. The sample is protected from radiation damage by automatically moving it out of the beam during the energy change and optimization.
- 15 February 2022
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 29 (2) , 393-399
Open AccessFast automated energy changes at synchrotron radiation beamlines equipped with transfocator or focusing mirrors
Algorithms and procedures to fully automate retuning of synchrotron radiation beamlines over wide energy ranges are discussed. The discussion is based on the implementation at the National Institute of General Medical Sciences and the National Cancer Institute Structural Biology Facility at the Advanced Photon Source. When a user selects a new beamline energy, software synchronously controls the beamline monochromator and undulator to maintain the X-ray beam flux after the monochromator, preserves beam attenuation by determining a new set of attenuator foils, changes, as needed, mirror reflecting stripes and the undulator harmonic, preserves beam focal distance of compound refractive lens focusing by changing the In/Out combination of lenses in the transfocator, and, finally, restores beam position at the sample by on-the-fly scanning of either the Kirkpatrick–Baez mirror angles or the transfocator up/down and inboard/outboard positions. The sample is protected from radiation damage by automatically moving it out of the beam during the energy change and optimization.
- 5 January 2011
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 649 (1) , 87-90
Control system for the 2nd generation Berkeley automounters (BAM2) at GM/CA-CAT macromolecular crystallography beamlines
- 5 January 2011
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 649 (1) , 87-90