Michael Dingfelder
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Michael Dingfelder has a total of 56 co-authors. Here are the top co-authors by number of shared publications:
A. Travia
Department of Physics, East Carolina University, Mailstop 563, Greenville, NC 27858, USA
2 shared publicationsG. Lapicki
2 shared publicationsH. G. Paretzke
GSF – National Research Center for Environment and Health, Institute of Radiation Protection, D-857
2 shared publications- Habib Zaidi
Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, Switzerland
2 shared publications - J. L. Shinpaugh
Department of Physics, East Carolina University Greenville, NC 27858, USA
2 shared publications - Alexis Papadopoulos
Medical Physics Laboratory, Department of Medicine, University of Ioannina, Ioannina, Greece
1 shared publication
Latest Publications
- Open Access
- 25 March 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (8)
Intercomparison of low-energy electron transport calculations by different Monte Carlo track-structure simulation codes
Objective. To evaluate the uncertainty of physical features of low-energy electron transport in liquid water due to the use of different Monte Carlo track-structure (MCTS) codes. Approach. Five MCTS codes developed specifically for liquid water, namely, Geant4-DNA, PHITS-TS, RITRACKS, NASIC, and PARTRAC are compared and used to calculate the electronic stopping power, pathlength and absorption range, dose-point-kernel, and the frequency-mean (y ̅_F) and dose-mean (y ̅_D) lineal energy for primary electron energies from 20 eV to 100 keV. The uncertainty of each calculated quantity is evaluated by the relative standard deviation (RSD) and the maximum relative difference (MRD) among the codes. The medium-to-high-energy (1‒100 keV) performance of the codes is benchmarked against the stopping power and range data for liquid water reported in ICRU Report 90. Main Results. For energies above ~1 keV the RSD is moderate and mostly between 5–15%, but increases rapidly at lower energies, reaching 20–100% at sub-100 eV energies. It is noteworthy that the MRD may well exceed 100% below 100 eV, while remaining sizeable (>20%) even at relatively high energies (10–100 keV). Fairly good agreement between the MCTS codes and the ICRU data for the stopping power (1‒100 keV) and range (10‒100 keV) in liquid water is found with average deviations between 1‒16%, depending on the code. Significance: The present work reveals significant differences for low-energy electron transport among liquid water MCTS codes, especially below 100 eV. These differences potentially compromise the accuracy of nanoscale simulations where such electrons play a key role. The observed dispersion of results is a consequence of the limitations of the theoretical models used to calculate electron interaction cross sections and the lack of relevant experimental data for their validation and benchmarking. This highlights the need for further development of the physics models used in MCTS codes to reduce the uncertainties associated with low-energy electron transport calculations in liquid water.
- 25 March 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (8)
Open AccessIntercomparison of low-energy electron transport calculations by different Monte Carlo track-structure simulation codes
Objective. To evaluate the uncertainty of physical features of low-energy electron transport in liquid water due to the use of different Monte Carlo track-structure (MCTS) codes. Approach. Five MCTS codes developed specifically for liquid water, namely, Geant4-DNA, PHITS-TS, RITRACKS, NASIC, and PARTRAC are compared and used to calculate the electronic stopping power, pathlength and absorption range, dose-point-kernel, and the frequency-mean (y ̅_F) and dose-mean (y ̅_D) lineal energy for primary electron energies from 20 eV to 100 keV. The uncertainty of each calculated quantity is evaluated by the relative standard deviation (RSD) and the maximum relative difference (MRD) among the codes. The medium-to-high-energy (1‒100 keV) performance of the codes is benchmarked against the stopping power and range data for liquid water reported in ICRU Report 90. Main Results. For energies above ~1 keV the RSD is moderate and mostly between 5–15%, but increases rapidly at lower energies, reaching 20–100% at sub-100 eV energies. It is noteworthy that the MRD may well exceed 100% below 100 eV, while remaining sizeable (>20%) even at relatively high energies (10–100 keV). Fairly good agreement between the MCTS codes and the ICRU data for the stopping power (1‒100 keV) and range (10‒100 keV) in liquid water is found with average deviations between 1‒16%, depending on the code. Significance: The present work reveals significant differences for low-energy electron transport among liquid water MCTS codes, especially below 100 eV. These differences potentially compromise the accuracy of nanoscale simulations where such electrons play a key role. The observed dispersion of results is a consequence of the limitations of the theoretical models used to calculate electron interaction cross sections and the lack of relevant experimental data for their validation and benchmarking. This highlights the need for further development of the physics models used in MCTS codes to reduce the uncertainties associated with low-energy electron transport calculations in liquid water.
- Open Access
- 30 September 2022
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 8 (6) , 065015
Hybrid computational pregnant female phantom construction for radiation dosimetry applications
The number of patients undergoing diagnostic radiology and radiation therapy procedures has increased drastically owing to improvements in cancer diagnosis and treatment, and consequently, patient survival. However, the risk of secondary malignancies owing to radiation exposure remains a matter of concern. We previously published three hybrid computational fetal phantoms, which contained 27 fetal organs, as a starting point for developing the whole hybrid computational pregnant phantom set, which is the final objective of this study. An International Commission on Radiological Protection (ICRP) reference female voxel model was converted to a non-uniform rational B-spline (NURBS) surface model to construct a hybrid computational female phantom as a pregnant mother for each fetal model. Both fetal and maternal organs were matched with the ICRP- 89 reference data. To create a complete standard pregnant computational phantom set at 20, 30, and 35 weeks of pregnancy, the model mother’s reproductive organs were removed, and fetal phantoms with appropriate placental and uterine models were added to the female pelvis using a 3D-modeling software. With the aid of radiological image sets that had originally been used to construct the fetal models, each fetal position and rotation inside the uterus were carefully adjusted to represent the real fetal locations inside the uterus. The major abdominal soft tissue organs below the diaphragm, namely the small intestine, large intestine, liver, gall bladder, stomach, pancreas, uterus, and urinary bladder, were removed from non-pregnant females. The resulting fetal phantom was positioned in the appropriate location, matching the original radiological image sets. An obstetrician-gynecologist reviewed the complete internal anatomy of all fetus phantoms and the pregnant women for accuracy, and suggested changes were implemented as needed. The remaining female anatomical tissues were reshaped and modified to accommodate the location of the fetus inside the uterus. This new series of hybrid computational pregnant phantom models provides realistic anatomical details that can be useful in evaluating fetal radiation doses in pregnant patients undergoing diagnostic imaging or radiotherapy procedures where realistic fetal computational human phantoms are required.
- 30 September 2022
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 8 (6) , 065015
Open AccessHybrid computational pregnant female phantom construction for radiation dosimetry applications
The number of patients undergoing diagnostic radiology and radiation therapy procedures has increased drastically owing to improvements in cancer diagnosis and treatment, and consequently, patient survival. However, the risk of secondary malignancies owing to radiation exposure remains a matter of concern. We previously published three hybrid computational fetal phantoms, which contained 27 fetal organs, as a starting point for developing the whole hybrid computational pregnant phantom set, which is the final objective of this study. An International Commission on Radiological Protection (ICRP) reference female voxel model was converted to a non-uniform rational B-spline (NURBS) surface model to construct a hybrid computational female phantom as a pregnant mother for each fetal model. Both fetal and maternal organs were matched with the ICRP- 89 reference data. To create a complete standard pregnant computational phantom set at 20, 30, and 35 weeks of pregnancy, the model mother’s reproductive organs were removed, and fetal phantoms with appropriate placental and uterine models were added to the female pelvis using a 3D-modeling software. With the aid of radiological image sets that had originally been used to construct the fetal models, each fetal position and rotation inside the uterus were carefully adjusted to represent the real fetal locations inside the uterus. The major abdominal soft tissue organs below the diaphragm, namely the small intestine, large intestine, liver, gall bladder, stomach, pancreas, uterus, and urinary bladder, were removed from non-pregnant females. The resulting fetal phantom was positioned in the appropriate location, matching the original radiological image sets. An obstetrician-gynecologist reviewed the complete internal anatomy of all fetus phantoms and the pregnant women for accuracy, and suggested changes were implemented as needed. The remaining female anatomical tissues were reshaped and modified to accommodate the location of the fetus inside the uterus. This new series of hybrid computational pregnant phantom models provides realistic anatomical details that can be useful in evaluating fetal radiation doses in pregnant patients undergoing diagnostic imaging or radiotherapy procedures where realistic fetal computational human phantoms are required.
- Top Cited Papers
- 15 June 2021
- Published by Royal Society of Chemistry (RSC) in Chemical Society Reviews
- Vol. 50 (15) , 8355-8360
Hydroxyl radical is a significant player in oxidative DNA damage in vivo
Recent publications have suggested that oxidative DNA damage mediated by hydroxyl radical (˙OH) is unimportant in vivo, and that carbonate anion radical (CO3˙−) plays the key role. We examine these claims and summarize the evidence that ˙OH does play a key role as an important member of the reactive oxygen species (ROS) in vivo.
- 15 June 2021
- Published by Royal Society of Chemistry (RSC) in Chemical Society Reviews
- Vol. 50 (15) , 8355-8360
Top Cited PapersHydroxyl radical is a significant player in oxidative DNA damage in vivo
Recent publications have suggested that oxidative DNA damage mediated by hydroxyl radical (˙OH) is unimportant in vivo, and that carbonate anion radical (CO3˙−) plays the key role. We examine these claims and summarize the evidence that ˙OH does play a key role as an important member of the reactive oxygen species (ROS) in vivo.
- Open Access
- 16 September 2019
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 64 (20) , 205003
Construction of realistic hybrid computational fetal phantoms from radiological images in three gestational ages for radiation dosimetry applications
Radiation exposure and associated radiation risks are major concerns for fetal development for pregnant patients who undergo radiation therapy or diagnostic imaging procedures. In order to accurately estimate the radiation dose to the fetus and assess the uncertainty of fetal position and rotation, three hybrid computational fetus phantoms were constructed using magnetic resonance imaging (MRI) for each fetus model as a starting point to construct a complete anatomically accurate fetus, gravid uterus, and placenta. A total of 27 fetal organs were outlined from radiological images via the Velocity Treatment Planning System. The DICOM-Structure set was imported to Rhinoceros software for further reconstruction of 3D fetus phantom model sets. All fetal organ masses were compared with ICRP-89 reference data. Our fetal model series corresponds to 20, 31, and 35 weeks of pregnancy, thus covering the second and third trimester. Fetal positions and locations were carefully adapted to represent the real fetus locations inside the uterus for each trimester of pregnancy. The new series of hybrid computational fetus models together with pregnant female models can be used in evaluating fetal radiation doses in diagnostic imaging and radiotherapy procedures.
- 16 September 2019
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 64 (20) , 205003
Open AccessConstruction of realistic hybrid computational fetal phantoms from radiological images in three gestational ages for radiation dosimetry applications
Radiation exposure and associated radiation risks are major concerns for fetal development for pregnant patients who undergo radiation therapy or diagnostic imaging procedures. In order to accurately estimate the radiation dose to the fetus and assess the uncertainty of fetal position and rotation, three hybrid computational fetus phantoms were constructed using magnetic resonance imaging (MRI) for each fetus model as a starting point to construct a complete anatomically accurate fetus, gravid uterus, and placenta. A total of 27 fetal organs were outlined from radiological images via the Velocity Treatment Planning System. The DICOM-Structure set was imported to Rhinoceros software for further reconstruction of 3D fetus phantom model sets. All fetal organ masses were compared with ICRP-89 reference data. Our fetal model series corresponds to 20, 31, and 35 weeks of pregnancy, thus covering the second and third trimester. Fetal positions and locations were carefully adapted to represent the real fetus locations inside the uterus for each trimester of pregnancy. The new series of hybrid computational fetus models together with pregnant female models can be used in evaluating fetal radiation doses in diagnostic imaging and radiotherapy procedures.
- 6 May 2015
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 166 (1-4) , 10-14
Cross sections for track structure codes: volume versus surface transport
Cross-section calculations and transport models for Monte Carlo track structure codes are discussed as well as the simulation of secondary electron emission yields from thin metal foils. Inelastic cross sections for volume (bulk) and surface transport of electrons in copper are presented and implemented into PARTRAC. Simulations for the volume and surface excitation model are presented and analysed.
- 6 May 2015
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 166 (1-4) , 10-14
Cross sections for track structure codes: volume versus surface transport
Cross-section calculations and transport models for Monte Carlo track structure codes are discussed as well as the simulation of secondary electron emission yields from thin metal foils. Inelastic cross sections for volume (bulk) and surface transport of electrons in copper are presented and implemented into PARTRAC. Simulations for the volume and surface excitation model are presented and analysed.
- 1 January 2014
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 83 (0 0) , 142-147
Updated model for dielectric response function of liquid water
- 1 January 2014
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 83 (0 0) , 142-147
Updated model for dielectric response function of liquid water
- 1 November 2012
- Published by Wolters Kluwer Health in Health Physics
- Vol. 103 (5) , 590-595
Track-structure Simulations for Charged Particles
Monte Carlo track-structure simulations provide a detailed and accurate picture of radiation transport of charged particles through condensed matter of biological interest. Liquid water serves as a surrogate for soft tissue and is used in most Monte Carlo track-structure codes. Basic theories of radiation transport and track-structure simulations are discussed and differences compared to condensed history codes highlighted. Interaction cross sections for electrons, protons, alpha particles, and light and heavy ions are required input data for track-structure simulations. Different calculation methods, including the plane-wave Born approximation, the dielectric theory, and semi-empirical approaches are presented using liquid water as a target. Low-energy electron transport and light ion transport are discussed as areas of special interest.
- 1 November 2012
- Published by Wolters Kluwer Health in Health Physics
- Vol. 103 (5) , 590-595
Track-structure Simulations for Charged Particles
Monte Carlo track-structure simulations provide a detailed and accurate picture of radiation transport of charged particles through condensed matter of biological interest. Liquid water serves as a surrogate for soft tissue and is used in most Monte Carlo track-structure codes. Basic theories of radiation transport and track-structure simulations are discussed and differences compared to condensed history codes highlighted. Interaction cross sections for electrons, protons, alpha particles, and light and heavy ions are required input data for track-structure simulations. Different calculation methods, including the plane-wave Born approximation, the dielectric theory, and semi-empirical approaches are presented using liquid water as a target. Low-energy electron transport and light ion transport are discussed as areas of special interest.
- 6 January 2011
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 143 (2-4) , 139-144
Simulation of secondary electron yields from thin metal foils after fast proton impact
Differential and total inelastic cross sections are derived for the interaction between fast protons and Cu. The calculations are done under the non-relativistic plane-wave first-Born approximation and the dielectric theory. A semi-empirical optical oscillator strength density function and a simple linear-momentum dispersion algorithm are used to construct the energy loss function or Bethe surface of the medium. A transport model using these inelastic cross sections is implemented in the Monte Carlo code PARTRAC to simulate the spectra of secondary electron emissions from this homogeneous and isotropic thin copper foil target. Comparisons with experimental results show general agreement for impact energies >50 eV up to non-relativistic values. The model, however, overestimates the secondary electron yields at lower energies.
- 6 January 2011
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 143 (2-4) , 139-144
Simulation of secondary electron yields from thin metal foils after fast proton impact
Differential and total inelastic cross sections are derived for the interaction between fast protons and Cu. The calculations are done under the non-relativistic plane-wave first-Born approximation and the dielectric theory. A semi-empirical optical oscillator strength density function and a simple linear-momentum dispersion algorithm are used to construct the energy loss function or Bethe surface of the medium. A transport model using these inelastic cross sections is implemented in the Monte Carlo code PARTRAC to simulate the spectra of secondary electron emissions from this homogeneous and isotropic thin copper foil target. Comparisons with experimental results show general agreement for impact energies >50 eV up to non-relativistic values. The model, however, overestimates the secondary electron yields at lower energies.
- 31 December 2008
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 77 (10-12) , 1213-1217
Electron emission from foils and biological materials after proton impact
- 31 December 2008
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 77 (10-12) , 1213-1217
Electron emission from foils and biological materials after proton impact
- 16 June 2008
- Published by American Physical Society (APS) in Physical Review A
- Vol. 77 (6) , 062710
Distorted-wave ionization and x-ray production cross sections of theKshell of Cu and theLshells of Ag, In, and Sn by positron impact
We study the ionization cross sections of the shell of Cu and the shells of Ag, In, and Sn by positron impact using the distorted-wave Born approximation, focusing on the near-threshold energy range (below 40 keV) to compare with recent measurements. The distorted-wave formalism proves to be an appropriate approach, especially to describe the shape of the cross-section curves for positrons accurately. Furthermore, we calculate x-ray production cross sections of the considered shells having recourse to two sets of atomic relaxation parameters involved in the conversion from ionization to x-ray production cross sections. The 5%–10% differences in the theoretical values calculated with these parameter sets are apparently not large enough to explain the discrepancy between the distorted-wave curves and the experimental data, particularly for Ag. Other sources of uncertainty that could be affecting these comparisons are discussed.- 16 June 2008
- Published by American Physical Society (APS) in Physical Review A
- Vol. 77 (6) , 062710
Distorted-wave ionization and x-ray production cross sections of theKshell of Cu and theLshells of Ag, In, and Sn by positron impact
We study the ionization cross sections of the shell of Cu and the shells of Ag, In, and Sn by positron impact using the distorted-wave Born approximation, focusing on the near-threshold energy range (below 40 keV) to compare with recent measurements. The distorted-wave formalism proves to be an appropriate approach, especially to describe the shape of the cross-section curves for positrons accurately. Furthermore, we calculate x-ray production cross sections of the considered shells having recourse to two sets of atomic relaxation parameters involved in the conversion from ionization to x-ray production cross sections. The 5%–10% differences in the theoretical values calculated with these parameter sets are apparently not large enough to explain the discrepancy between the distorted-wave curves and the experimental data, particularly for Ag. Other sources of uncertainty that could be affecting these comparisons are discussed.