PYPablo Yepes

Pablo Yepes

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Pablo Yepes has a total of 40 co-authors. Here are the top co-authors by number of shared publications:

  • Dragan Mirkovic

    Department of Radiation Physics, The University of Texas MD Anderson Cancer, Houston, Texas

    6 shared publications
  • Radhe Mohan

    Department of Radiation Physics Unit 1420 The University of Texas MD Anderson Cancer Center Houston Texas USA

    5 shared publications
  • Uwe Titt

    Department of Radiation Physics Unit 1420 The University of Texas MD Anderson Cancer Center Houston Texas USA

    5 shared publications
  • Phillip J. Taddei

    American University of Beirut Medical Center, Beirut, Lebanon

    4 shared publications
  • Sharmalee Randeniya

    Department of Radiation Physics, Unit 1420, The University of Texas M. D. Anderson Cancer, 1515 Holcombe Blvd., Houston, TX 77030, USA

    4 shared publications
  • Amy Liu

    Department of Radiation Oncology, The University of Texas MD Anderson Cancer, Houston, Texas

    3 shared publications

Latest Publications

  • Open Access

    A Three–Dimensional Ontological Formulation of Bohmian Mechanics

    by Pablo P. Yepes

    We present a three–dimensional field ontology for Bohmian mechanics in which the single-particle wave functions defined in ordinary physical space are taken as ontological elements alongside particle positions. In this view, each particle is associated with a wave function in three–dimensional space conditioned on the actual positions of the remaining particles. The universal wave function on configuration space is retained within the formalism, but its role is interpreted as nomological: it determines the coupled evolution of the three–dimensional fields without itself being treated as a fundamental physical field. The corresponding evolution equations for the conditioned three–dimensional wave functions follow from the standard Bohmian formalism and, together with the guidance equation, yield dynamics fully equivalent to those of the conventional theory. The empirical and predictive content of Bohmian mechanics is thereby preserved, while its ontological structure is expressed in explicitly three–dimensional terms. Within a ψ-ontic perspective, this proposal makes explicit an ontological organization of Bohmian mechanics in which the dynamical fields are defined on physical space. While fully equivalent to the conventional formulation, expressing the theory in these terms may facilitate interpretation, visualization, and pedagogical presentation.

  • Open Access

    A Three-Dimensional Reformulation of Bohmian Mechanics

    by Pablo Yepes

    We propose a reinterpretation of Bohmian mechanics in which the single--particle wave functions defined in ordinary three--dimensional space---usually treated as conditional or derived quantities---are elevated to ontological primitives. In this formulation, particle positions and their associated three--dimensional wave functions jointly constitute the fundamental ontology, while the universal wave function on configuration space is retained as part of the formal structure generating their dynamics. Each particle is associated with a wave function in three--dimensional space, conditioned on the actual positions of the others, yielding an exact reformulation of standard Bohmian dynamics. Within a \( \psi \)--ontic framework supported by the Pusey--Barrett--Rudolph theorem, we argue that the ontological status of the wave function need not be tied to configuration space, but may instead be realized through interacting wave fields defined directly in physical space. This reinterpretation preserves the full empirical and dynamical content of Bohmian mechanics while restoring a spatially grounded ontology. Although no new testable predictions are introduced, the proposed framework secures three conceptual gains: ontological clarity, pedagogical accessibility, and extension potential. The novelty lies in providing an exact, spatially grounded reformulation that clarifies the ontological role of wave functions without committing to configuration space as the fundamental arena of physical reality.

  • Open Access

    Solid-State Detector for FLASH Radiotherapy: Dosimetric Applications and Emerging Concepts

    by Pablo P. Yepes

    The implementation of FLASH Radiotherapy (FLASH-RT), characterized by ultra-high dose rates (UHDRs) frequently exceeding 106 Gy/s in microsecond pulses, imposes stringent requirements on real-time dosimetry. Conventional ionization chambers suffer severe ion recombination and space-charge limitations under these conditions. This review summarizes the state of SSD technologies—including conventional standard silicon diodes, advanced SiC diodes, Low-Gain Avalanche Detectors (LGADs), and pixel detectors—and compares their performance, linearity, and dynamic range in UHDR environments. Particular attention is devoted to operational modes (integrating vs. counting), saturation mechanisms, and readout electronics, which frequently dominate detector behavior at FLASH conditions. We discuss the experimental results from recent UHDR beamlines and highlight emerging concepts that will shape future clinical translation.


  • Open Access

    Solid-State Detector for FLASH Radiotherapy: Dosimetric Applications and Emerging Concepts

    by Pablo Yepes

    The implementation of FLASH Radiotherapy (FRT), characterized by ultra-high dose rates (UHDRs) frequently exceeding 106 Gy/s in microsecond pulses, imposes stringent requirements on real-time dosimetry. Conventional ionization chambers suffer severe ion recombination and space-charge limitations under these conditions. This review summarizes the state of SSD technologies—including conventional standard silicon diodes, advanced SiC diodes, LGADs, and pixel detectors—and compares their performance, linearity, and dynamic range in UHDR environments. Particular attention is devoted to operational modes (integrating vs. counting), saturation mechanisms, and readout electronics, which frequently dominate detector behavior at FLASH conditions. We discuss experimental results from recent UHDR beamlines and highlight emerging concepts that will shape future clinical translation.

  • Optimization of FLASH proton beams using a track‐repeating algorithm

    by Qianxia Wang, Uwe Titt, Radhe Mohan, Fada Guan, Yao Zhao, Ming Yang, Pablo Yepes

    Background Radiation with high dose rate (FLASH) has shown to reduce toxicities to normal tissues around the target and maintain tumor control with the same amount of dose compared to conventional radiation. This phenomenon has been widely studied in electron therapy, which is often used for shallow tumor treatment. Proton therapy is considered a more suitable treatment modality for deep-seated tumors. The feasibility of FLASH proton therapy has recently been demonstrated by a series of pre- and clinical trials. One of the challenges is to efficiently generate wide enough dose distributions in both lateral and longitudinal directions to cover the entire tumor volume. The goal of this paper is to introduce a set of automatic FLASH proton beam optimization algorithms developed recently. Purpose To develop a fast and efficient optimizer for the design of a passive scattering proton FLASH radiotherapy delivery at The University of Texas MD Anderson Proton Therapy Center, based on the fast dose calculator (FDC). Methods A track-repeating algorithm, FDC, was validated versus Geant4 simulations and applied to calculate dose distributions in various beamline setups. The design of the components was optimized to deliver homogeneous fields with well-defined diameters between 11.0 and 20.5 mm, as well as a spread-out Bragg peak (SOBP) with modulations between 8.5 and 39.0 mm. A ridge filter, a high-Z material scatterer, and a collimator with range compensator were inserted in the beam path, and their shapes and sizes were optimized to spread out the Bragg peak, widen the beam, and reduce the penumbra. The optimizer was developed and tested using two proton energies (87.0 and 159.5 MeV) in a variety of beamline arrangements. Dose rates of the optimized beams were estimated by scaling their doses to those of unmodified beams. Results The optimized 87.0-MeV beams, with a distance from the beam pipe window to the phantom surface (window-to-surface distance [WSD]) of 550 mm, produced an 8.5-mm-wide SOBP (proximal 90% to distal 90% of the maximum dose); 14.5, 12.0, and 11.0-mm lateral widths at the 50%, 80%, and 90% dose location, respectively; and a 2.5-mm penumbra from 80% to 20% in the lateral profile. The 159.5-MeV beam had an SOBP of 39.0 mm and lateral widths of 20.5, 15.0, and 12.5 mm at 50%, 80%, and 90% dose location, respectively, when the WSD was 550 mm. Wider lateral widths were obtained with increased WSD. The SOBP modulations changed when the ridge filters with different characteristics were inserted. Dose rates on the beam central axis for all optimized beams (other than the 87.0-MeV beam with 2000-mm WSD) were above that needed for the FLASH effect threshold (40 Gy/s) except at the very end of the depth dose profile scaling with a dose rate of 1400 Gy/s at the Bragg peak in the unmodified beams. The optimizer was able to instantly design the individual beamline components for each of the beamline setups, without the need of time intensive iterative simulations. Conclusion An efficient system, consisting of an optimizer and an FDC have been developed and validated in a variety of beamline setups, comprising two proton energies, several WSDs, and SOBPs. The set of automatic optimization algorithms produces beam shaping element designs efficiently and with excellent quality.


  • Open Access

    Automatic phase space generation for Monte Carlo calculations of intensity modulated particle therapy

    by Qianxia Wang, Cong Zhu, Xuemin Bai, Yu Deng, Nicki Schlegel, Antony Adair, Zhi Chen, Yongqiang Li, Michael Moyers, Pablo P Yepes

    Monte Carlo (MC) is generally considered as the most accurate dose calculation tool for particle therapy. However, a proper description of the beam particle kinematics is a necessary input for a realistic simulation. Such a description can be stored in phase space (PS) files for different beam energies. A PS file contains kinetic information such as energies, positions and travelling directions for particles traversing a plane perpendicular to the beam direction. The accuracy of PS files plays a critical role in the performance of the MC method for dose calculations. A PS file can be generated with a set of parameters describing analytically the beam kinematics. However, determining such parameters can be tedious and time consuming. Thus, we have developed an algorithm to obtain those parameters automatically and efficiently. In this paper, we presented such an algorithm and compared dose calculations using PS automatically generated for the Shanghai Proton and Heavy Ion Center (SPHIC) with measurements. The gamma-index for comparing calculated depth dose distributions (DDD) with measurements are above 96.0% with criterion 0.6%/0.6 mm. For each single energy, the mean difference percentage between calculated lateral spot sizes at 5 different locations along beam direction and measurements are below 3.5%.


  • Open Access

    Automatic phase space generation for Monte Carlo calculations of Intensity Modulated Particle Therapy

    by Qianxia Wang, Cong Zhu, Xuemin Bai, Yu Deng, Nicki Schlegel, Antony Adair, Zhi Chen, Yongqiang Li, Michael Moyers, Pablo Yepes

    Monte Carlo (MC) is generally considered as the most accurate dose calculation tool for particle therapy. However, a proper description of the beam particles kinematics is a necessary input for a realistic simulation. Such a description can be stored in phase space (PS) files for different beam energies. A PS file contains kinetic information such as energies, positions and travelling directions for particles traversing a plane perpendicular to the beam direction. The accuracy of PS files play a critical role in the performance of the MC method for dose calculations. A PS file can be generated with a set of parameters describing analytically the beam kinematics. However, determining such parameters can be tedious and time consuming. Thus, we have developed an algorithm to obtain those parameters automatically and efficiently. In this paper, we present such an algorithm and compare dose calculations using PS automatically generated for the Shanghai Proton and Heavy Ion Center (SPHIC) with measurements. The gamma-index for comparing calculated depth dose distributions (DDD) with measurements are above 96.0% with criterion 0.6%/0.6 mm. For each single energy, the mean difference percentage between calculated lateral spot sizes at 5 different depths and measurements are below 3.5%.

  • Open Access

    Fixed- versus Variable-RBE Computations for Intensity Modulated Proton Therapy

    by Pablo Yepes, Antony Adair, Steven J. Frank, David R. Grosshans, Zhongxing Liao, Amy Liu, Dragan Mirkovic, Falk Poenisch, Uwe Titt, Qianxia Wang, et al.


  • Comparison of Monte Carlo and analytical dose computations for intensity modulated proton therapy

    by Pablo P Yepes, Antony H Adair, David R Grosshans, Dragan Mirkovic, Falk Poenisch, Uwe Titt, Qianxia Wang, Radhe Mohan

    To evaluate the effect of approximations in clinical analytical calculations performed by a treatment planning system (TPS) on dosimetric indices in intensity modulated proton therapy. TPS calculated dose distributions were compared with dose distributions as estimated by Monte Carlo (MC) simulations, calculated with the fast dose calculator (FDC) a system previously benchmarked to full MC. This study analyzed a total of 525 patients for four treatment sites (brain, head-and-neck, thorax and prostate). Dosimetric indices (D02, D05, D20, D50, D95, D98, EUD and Mean Dose) and a gamma-index analysis were utilized to evaluate the differences. The gamma-index passing rates for a 3%/3 mm criterion for voxels with a dose larger than 10% of the maximum dose had a median larger than 98% for all sites. The median difference for all dosimetric indices for target volumes was less than 2% for all cases. However, differences for target volumes as large as 10% were found for 2% of the thoracic patients. For organs at risk (OARs), the median absolute dose difference was smaller than 2 Gy for all indices and cohorts. However, absolute dose differences as large as 10 Gy were found for some small volume organs in brain and head-and-neck patients. This analysis concludes that for a fraction of the patients studied, TPS may overestimate the dose in the target by as much as 10%, while for some OARs the dose could be underestimated by as much as 10 Gy. Monte Carlo dose calculations may be needed to ensure more accurate dose computations to improve target coverage and sparing of OARs in proton therapy.


  • Validation of a track-repeating algorithm versus measurements in water for proton scanning beams

    by Pablo P Yepes, Fada Guan, Matthew Kerr, Sharmalee Randeniya, Yuting Li, Lawrence Bronk, Amy Liu, Dragan Mirkovic, Narayan Sahoo, Uwe Titt, et al.

    Dose distributions calculated with the fast dose calculator (FDC), a track repeating-algorithm for proton therapy, have been validated versus dose measurements in water for scanning proton beams at the University of Texas MD Anderson Cancer Center Proton Therapy Center in Houston. The dose calculated with FDC, at the position of the measured points for depth and lateral profiles, was compared to the measurements with a gamma-index analysis. It was found that 99.9% and 99.5% of the measured points had a gamma-index value smaller than unity for the 3%/3 mm and 2%/2 mm dose/distance agreement criteria, respectively.