JBJennifer Kehlet Barton

Jennifer Kehlet Barton

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Jennifer Kehlet Barton has a total of 297 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Gait Analysis Using mmWave Radar: A Skeleton-Based Approach With Point Cloud Transformer

    by Jiahao Tang, Shuting Hu, Siyang Cao, Jennifer Barton, Melvin G. Hector, Mindy J. Fain, Nima Toosizadeh

  • Open Access

    Quantitative analysis of collagen architecture in the human uterotubal junction (UTJ) using optical coherence tomography imaging (OCT)

    by Dilara Long, Robert Klein, Makayla Johnson, Jillian Leaver, Photini Rice, Julia Fisher, Arielle Joasil, Victoria Fewell, John Heusinkveld, Christine Hendon, et al.

    Abnormal uterotubal junction (UTJ) structure is implicated in the pathogenesis of endometriosis and infertility; however, this relationship remains poorly characterized. We quantitatively characterized the orientation of collagen fiber bundles in the UTJ using optical coherence tomography (OCT). UTJ tissue from nine individuals undergoing hysterosalpingectomy were collected and longitudinally opened to expose the lumen. Volumetric OCT images were acquired from proximal (uterine), middle, and distal (isthmic) UTJ segments. Images were preprocessed to enhance contrast and continuity of fiber bundles. Local fiber bundle orientation was extracted from Sobel-filtered intensity gradients. Orientation values were binned corresponding to the expected alignment of collagen fiber bundle groups in UTJ smooth muscle: longitudinal (0°-30°), oblique (30°-60°), and circumferential (60°-90°). Proportions were plotted as a function of depth, and depth-dependent trends in alignment were compared across UTJ segments using mixed-effects models. Measurements revealed a prominent inner longitudinal muscle layer which emerged proximally and thinned distally, and an outer muscle layer composed of oblique uterine fiber bundles proximally and a mixed oblique-circumferential contribution distally. These findings provide the first quantitative, depth-resolved analysis of UTJ collagen architecture and establish an analytical framework which can support future studies investigating how UTJ structure relates to function and disease.

  • Open Access

    Improved endoscope for imaging and cell collection in the fallopian tubes

    by Dominique Gálvez, Andrew Daniel Rocha, Alana G. Gonzales, Dilara J. Long, Photini Faith Rice, Makayla R. Johnson, Ethan Tovar, Bo Lwin, Helen Varghese, Kongit Amaha, et al.

    SignificanceEarly detection of ovarian cancer requires the observation of subtle changes within the fallopian tubes, where serous tubal intraepithelial carcinoma lesions, the putative precursor of high-grade ovarian serous carcinoma, may be present and detectable.AimThe cell-acquiring fallopian endoscope was designed to detect and interrogate potentially pathological sites in the fallopian tubes via alterations in fluorescence signal and the collection of epithelial cells.ApproachWe performed a comprehensive redesign of a first-generation endoscope prototype and demonstrated its performance in whole, human ex vivo fallopian tubes. Through the iterative improvements to the design, the endoscope features improved imaging, cell collection, and general ease of use. Specifically, improvements included a larger core count fiber imaging bundle, a redesigned close-focus lens, more flexible materials, an altered cell collection method, and a lighter-weight handle.ResultsWith benign fallopian tube samples from three patients, we demonstrate cell collection on the order of 104 cells per collection and imaging capabilities that result in average image intensity ratios.ConclusionsThis second-generation endoscope is suitable for the study of intact fallopian tubes.


  • Open Access

    Optical coherence tomography and elastography for ex vivo visualization of early gastric cancer

    by Alana G. Gonzales, Caitlin Ruhland, Graham Spicer, Stephen Mead, Massimiliano Di Pietro, Ashraf Sanduka, Photini F. S. Rice, Ryan H. W. Mitstifer, Sarah E. Bohndiek, Travis W. Sawyer, et al.

    SignificanceStomach (gastric) cancer survival depends significantly on the stage in which it is detected, and surveillance with white light endoscopy exhibits poor contrast between gastric cancer and healthy tissue, especially at early stages. Early gastric cancer can exhibit changes in epithelial microstructure, including loss of regular gastric pit structure and collagen alterations which increase tissue stiffness.AimTo improve contrast between early cancer and normal tissue, we investigate the use of optical coherence tomography (OCT) and elastography (OCE) to visualize changes in tissue structure and stiffness consistent with gastric cancer.ApproachImages of eight samples of ex vivo human stomach tissue from three patients were collected with a benchtop OCT system. OCT was performed for qualitative visualization of tissue structure. OCE was then performed on 17 regions of interest using a simplified optical palpation method to extract relative stiffness measurements. A transparent silicone reference layer was placed on the tissue, and axial compression was applied. The resulting deformation (strain) of the reference layer was measured, and the corresponding stress applied to the sample surface was extracted from the characteristic stress-strain curve of the reference material. Spatially resolved stress measurements were mapped and overlaid on en face OCT images. Tissue classification was confirmed by pathology.ResultsOCT image volumes showed more distinct gastric pit and tissue layer structure, as well as less optical attenuation, in normal tissue compared to gastric metaplasia and focal signet ring cell carcinoma (SRCC). Exemplary OCE-derived stress maps showed a trend of increasing measured stress with progression of precancer (metaplasia and dysplasia) and SRCC, suggesting increased tissue stiffness.ConclusionsThis proof-of-concept study provides evidence that OCT and OCE may be capable of visualizing differences in tissue structure and stiffness between normal, metaplastic, dysplastic, and early cancerous gastric tissue, potentially providing the basis for improved screening tools with higher sensitivity.


  • Open Access

    Lens design strategies for miniature scanning fiber endoscopes

    by Andrew D. Rocha, Dominique Galvez, Alana Gonzales, Eduardo Gonzalez, Matthias Schlich, David Vega, Jennifer K. Barton

    The trend toward miniaturization of endoscopes is driven by demand for early disease detection, improved patient outcomes through minimally invasive technology, and the miniaturization needed for pediatric applications. Advances in imaging technology and materials allow the production of endoscopes enabling access to narrow or delicate anatomical areas with reduced invasiveness of procedures. However, as endoscope diameters decrease, challenges arise in the optical design of their imaging systems. Commercially available camera modules have miniaturized sufficiently to create “chip-on-tip” microendoscopes, which encapsulate the optical lens and imaging sensor in a small package at the distal end of an endoscope, requiring only electrical connections to be routed through the endoscope body. An example of one of these miniaturized camera modules is the OMNIVISION OV6948, which has a 200×200 array of 1.75  μm pixels, for a total of 40,000 pixels, with a diagonal length of 0.919 mm.1 Although these camera modules are well-equipped for some applications, they are not a comprehensive solution. For example, the number of pixels in these miniature camera modules may be insufficient for few-micron resolution imaging at multiple-millimeter field of view (FOV). In addition, the sensitivity of miniature CMOS sensors may be insufficient for imaging modalities with weak signals, such as autofluorescence imaging (AFI), in part because of the small pixel size. In some cases, camera modules are only available with fixed filters, which may reduce signal, and limit the number of pixels per image in sensitive, hyperspectral designs.2


  • Optical Coherence Tomography Enables the Depth‐Resolved Measurement of Cilia Beat Frequency in Ex Vivo Human Fallopian Tubes

    by Dilara J. Long, Tian Xia, Photini F. Rice, Deirdre M. Scully, Makayla Johnson, Ryan Mitstifer, Andrea Aguirre, John M. Heusinkveld, Irina V. Larina, Jennifer K. Barton

    Objectives: The movement of cilia in the fallopian tubes (FTs) facilitates important processes involved in fertility, and abnormalities in cilia function are linked with diseases including endometriosis and pelvic inflammatory disease. For the first time, we demonstrate the use of optical coherence tomography (OCT) to create depth‐resolved mapping of motile cilia locations and quantify cilia beat frequency (CBF) in human FT samples ex vivo.Methods: Segments of the FT ampulla were acquired from five patients following salpingectomy under an IRB approved protocol. The samples were longitudinally opened to expose the luminal surface for imaging. A sequence of at least 500 OCT images were acquired at 5–10 locations on each sample. To define the location of the motile cilia in the images, pixel‐wise Fast Fourier Transform (FFT) analysis of intensity fluctuations with a sliding temporal window was performed on each image sequence. The frequencies corresponding to the physiological range of CBF (2–10 Hz) were selected for mapping, while the part of the FFT spectrum at higher frequencies (> 23 Hz) was used to define the noise threshold. The frequency with the highest FFT amplitude for each supra‐threshold pixel was considered the CBF for this pixel and used to create a color‐coded CBF map. The CBF map was overlaid with the OCT intensity image sequences to reveal cilia locations. Frequency histograms from the sliding window were examined to assess temporal consistency of the mapping and evaluate movement artifacts.Results: OCT image sequences clearly showed the structure of FT plicae. The ciliated epithelium was obvious as a “shimmering” (rapidly changing intensity) layer atop plicae. Colored pixels on CBF maps visually aligned to these shimmering regions. Frequency histograms revealed that the image sequence peak CBF could be robustly determined, even in the presence of outliers attributable to table vibrations or bulk sample movement.Conclusions: OCT can provide depth‐resolved maps of CBF in human ex vivo FT tissue. Potentially, this technique can aid in understanding cilia dynamics in the normal human FT over the menstrual cycle and across age, as well as in diseases that affect the FTs. Future work will be directed toward in vivo implementation including miniaturization and robust motion compensation.

  • Open Access

    Scalable fabrication of single- and multi-layer planar lenses on fiber imaging probes

    by Fei He, Rafael Fuentes-Domínguez, Richard Cousins, Christopher J. Mellor, Andrew Daniel Rocha, Zuzana Adams, Jennifer K. Barton, George S. D. Gordon

    We present a novel, scalable method for fabricating single- and multi-layer planar lenses on 125 μm-diameter fiber imaging probes, demonstrating preliminary capabilities for both lateral imaging (e.g., confocal microscopy) and axial imaging, using optical coherence tomography (OCT) as an exemplar. Hair-thin fiber endoscopes hold great promise for biomedical imaging, especially when paired with custom optics. For instance, OCT benefits from fiber facets that generate needle-like Bessel beams with a large depth-of-field (DOF), while wide-field imaging requires shorter DOF and higher lateral resolution. Current devices often rely on direct fabrication on fiber tips, which is incompatible with high-volume planar nano-fabrication necessary for producing low-cost disposable biomedical devices. In this paper, we propose a scalable fabrication approach compatible with semiconductor manufacturing, which also allows for simultaneous transfer of multiple devices onto fibers. We demonstrate this by transferring four planar lenses at once. To prove their imaging abilities, we designed and transferred a Fresnel zone plate, optimized for lateral imaging, and a diffractive axicon, optimized for axial imaging, onto fiber facets. The axicon fiber generates a needle-like Bessel beam with a 350 μm focal depth, retrieving focused images from a standard resolution target over a 150 μm range. We also present a preliminary demonstration of OCT imaging of reflective targets with a commercial system. Finally, we show that this approach supports multi-layer devices, by fabricating a two-layer Fresnel zone plate fiber probe, which exhibits good imaging performance. This method could enable the integration of complex, multi-functional optical structures onto fibers for advanced imaging and sensing applications.


  • mmWave Radar for Sit-to-Stand Analysis: A Comparative Study With Wearables and Kinect

    by Shuting Hu, Peggy Ackun, Xiang Zhang, Siyang Cao, Jennifer Barton, Melvin G. Hector, Mindy J. Fain, Nima Toosizadeh

    This study investigates a novel approach for analyzing Sit-to-Stand (STS) movements using millimeter-wave (mmWave) radar technology, aiming to develop a non-contact, privacy-preserving, and all-day operational solution for healthcare applications. A 60 GHz mmWave radar system was employed to collect radar point cloud data from 45 participants performing STS motions. Using a deep learning-based pose estimation model and Inverse Kinematics (IK), we calculated joint angles, segmented STS motions, and extracted clinically relevant features for fall risk assessment. The extracted features were compared with those obtained from Kinect and wearable sensors. While Kinect provided a reference for motion capture, we acknowledge its limitations compared to the gold-standard VICON system, which is planned for future validation. The results demonstrated that mmWave radar effectively captures general motion patterns and large joint movements (e.g., trunk), though challenges remain for more fine-grained motion analysis. This study highlights the unique advantages and limitations of mmWave radar and other sensors, emphasizing the potential of integrated sensor technologies to enhance the accuracy and reliability of motion analysis in clinical and biomedical research. Future work will expand the scope to more complex movements and incorporate high-precision motion capture systems to further validate the findings.


  • Open Access

    Kallikrein-Related Peptidase 6 Contributes to Murine Intestinal Tumorigenesis Driven by a Mutant Adenomatous polyposis coli Gene

    by Teodora G. Georgieva, Dalila Darmoul, Hwudaurw Chen, Haiyan Cui, Photini F. S. Rice, Jennifer K. Barton, David G. Besselsen, Natalia A. Ignatenko

    Background/Objectives: The objective of this study was to assess the role of a secreted serine protease, kallikrein-related peptidase 6 (KLK6), during colorectal tumorigenesis driven by a mutant Adenomatous polyposis coli (APC) tumor suppressor gene. A first analysis of KLK6 expression in the intestinal tract of Apc-mutant multiple intestinal neoplasia (ApcMin/+) mice revealed up to four-fold induction of Klk6 mRNA levels in adenomas relative to its level in the adjacent mucosa. Methods and Results: The presence of KLK6 protein in the adenomatous areas was confirmed by immunohistochemistry and optical coherence tomography/laser-induced fluorescence (OCT/LIF) imaging. To assess the contribution of the KLK6 expression on the Apc-mutant intestinal and colon tumorigenesis, we engineered a mouse with floxed alleles of the Klk6 gene (Klk6lox/lox) and crossed it with a mouse expressing the truncated APC protein under control of the intestinal tract-specific human CDX2P9.5-NLS Cre transgene (CPC;Apcfl/fl;Klk6+/+). We found that CPC;Apcfl/fl mice with disrupted Klk6 gene expression (CPC;Apcfl/fl;Klk6fl/fl) had a significantly smaller average size of the small intestinal and colon crypts (p < 0.001 and p = 0.04, respectively) and developed a significantly fewer adenomas (p = 0.01). Moreover, a decrease in high-grade adenomas (p = 0.03) and adenomas with a diameter above 2 mm (p < 0.0001) was noted in CPC;Apcfl/fl;Klk6fl/fl mice. Further molecular analysis showed that Klk6 gene inactivation in the small intestine and colon tissues of CPC;Apcfl/fl;Klk6fl/fl mice resulted in a significant suppression of transforming growth factor β2 (TGF-β2) protein (p ≤ 0.02) and mitogen-activated protein kinase (MAPK) phosphorylation (p ≤ 0.01). Conclusions: These findings demonstrate the oncogenic role of KLK6 in the mutant Apc-mediated intestinal tumorigenesis and suggest the utility of KLK6 for early diagnosis of colorectal tumors.

  • Open Access

    Feasibility of non-imaging, random-sampling second harmonic generation measurements to distinguish colon cancer

    by Jenna Montague, Lucas Young, Hasina Shir, Travis W. Sawyer, Joshua Routh, Valentine N. Nfonsam, Jennifer Kehlet Barton

    SignificanceIn the United States, colorectal cancer is the third leading cause of cancer death. Colonoscopy with polyp removal may suffer from incomplete resection. Collagen is altered in dysplastic tissue and can be studied with second harmonic generation (SHG) imaging. SHG imaging endoscopes require miniaturized scanning components, which greatly adds to endoscope complexity.AimWe investigate whether non-imaging, randomly sampled SHG line or point intensity measurements are sufficient to distinguish normal tissue from tumor and tumor-adjacent tissue.ApproachUnstained tumor, normal, and tumor-adjacent thin sections from 10 colorectal cancer subjects were imaged using a multiphoton microscope with constant power. SHG signal from collagen was isolated by grayscale thresholding, and the grayscale mean of the image was calculated. Supra-threshold pixels and lines of pixels in the image were randomly selected to simulate point sampling and line scanning.ResultsThe mean SHG signal from normal samples was significantly greater than adjacent samples (p<0.05) and tumor samples (p<0.01). For both sampling types, the p-value becomes reliable after randomly sampling only 1000 times.ConclusionsReliable cancer detection information may be obtained through non-imaging SHG intensity measurements. A simple endoscope with this capability could help identify suspicious masses or optimum surgical margins.