Dominique Galvez
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Dominique Galvez has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
- Jennifer Kehlet Barton
The University of Arizona
6 shared publications - John Heusinkveld
Universidad de Arizona, Tucson, Estados Unidos
5 shared publications - Andrew Daniel Rocha
University of Arizona, Wyant College of Optical Sciences, Tucson, Arizona, United States
4 shared publications - Dilara J. Long
University of Arizona, Department of Biomedical Engineering, Tucson, Arizona, United States
3 shared publications - Photini F. S. Rice
University of Arizona, Department of Biomedical Engineering, Tucson, Arizona, United States
3 shared publications David Vega
Ansys, Tucson, Arizona, United States
2 shared publications
Latest Publications
- Open Access
- 17 March 2026
- Published by SPIE-Intl Soc Optical Eng in Biophotonics Discovery
- Vol. 3 (02) , 1-16
Improved endoscope for imaging and cell collection in the fallopian tubes
SignificanceEarly detection of ovarian cancer requires the observation of subtle changes within the fallopian tubes, where serous tubal intraepithelial carcinoma lesions, the putative precursor of high-grade ovarian serous carcinoma, may be present and detectable.AimThe cell-acquiring fallopian endoscope was designed to detect and interrogate potentially pathological sites in the fallopian tubes via alterations in fluorescence signal and the collection of epithelial cells.ApproachWe performed a comprehensive redesign of a first-generation endoscope prototype and demonstrated its performance in whole, human ex vivo fallopian tubes. Through the iterative improvements to the design, the endoscope features improved imaging, cell collection, and general ease of use. Specifically, improvements included a larger core count fiber imaging bundle, a redesigned close-focus lens, more flexible materials, an altered cell collection method, and a lighter-weight handle.ResultsWith benign fallopian tube samples from three patients, we demonstrate cell collection on the order of 104 cells per collection and imaging capabilities that result in average image intensity ratios.ConclusionsThis second-generation endoscope is suitable for the study of intact fallopian tubes.
- 17 March 2026
- Published by SPIE-Intl Soc Optical Eng in Biophotonics Discovery
- Vol. 3 (02) , 1-16
Open AccessImproved endoscope for imaging and cell collection in the fallopian tubes
SignificanceEarly detection of ovarian cancer requires the observation of subtle changes within the fallopian tubes, where serous tubal intraepithelial carcinoma lesions, the putative precursor of high-grade ovarian serous carcinoma, may be present and detectable.AimThe cell-acquiring fallopian endoscope was designed to detect and interrogate potentially pathological sites in the fallopian tubes via alterations in fluorescence signal and the collection of epithelial cells.ApproachWe performed a comprehensive redesign of a first-generation endoscope prototype and demonstrated its performance in whole, human ex vivo fallopian tubes. Through the iterative improvements to the design, the endoscope features improved imaging, cell collection, and general ease of use. Specifically, improvements included a larger core count fiber imaging bundle, a redesigned close-focus lens, more flexible materials, an altered cell collection method, and a lighter-weight handle.ResultsWith benign fallopian tube samples from three patients, we demonstrate cell collection on the order of 104 cells per collection and imaging capabilities that result in average image intensity ratios.ConclusionsThis second-generation endoscope is suitable for the study of intact fallopian tubes.
- 8 January 2026
- Published by Optica Publishing Group in Applied Optics
- Vol. 65 (2) , 637-645
Resolution cascade: simulated MTF of a coherent fiber bundle-based microendoscopic system
Despite advances in miniaturization of CMOS sensors, current submillimeter diameter microendoscopic systems rely on coherent fiber bundles to transfer the image from its collection point to the detector. Determining the resolution of an endoscopic optical system that employs a fiber bundle is nontrivial, and there is limited published information about how to calculate the theoretical modulation transfer function (MTF) of a system that may include a distal lens, fiber bundle, relay optics, and a camera sensor. While the fiber bundle is frequently considered the resolution-limiting element, greater information may be gained from computing the full system MTF. In this paper, we describe a resolution cascade method that calculates theoretical MTFs for common components, as well as for the entire microendoscopic system. These theoretical calculations compare favorably to experimentally gathered data for four different optical configurations. The software developed for these calculations is freely available to predict the MTF of other coherent fiber bundle-based systems. Brief instructions and necessary assumptions/conditions are described.
- 8 January 2026
- Published by Optica Publishing Group in Applied Optics
- Vol. 65 (2) , 637-645
Resolution cascade: simulated MTF of a coherent fiber bundle-based microendoscopic system
Despite advances in miniaturization of CMOS sensors, current submillimeter diameter microendoscopic systems rely on coherent fiber bundles to transfer the image from its collection point to the detector. Determining the resolution of an endoscopic optical system that employs a fiber bundle is nontrivial, and there is limited published information about how to calculate the theoretical modulation transfer function (MTF) of a system that may include a distal lens, fiber bundle, relay optics, and a camera sensor. While the fiber bundle is frequently considered the resolution-limiting element, greater information may be gained from computing the full system MTF. In this paper, we describe a resolution cascade method that calculates theoretical MTFs for common components, as well as for the entire microendoscopic system. These theoretical calculations compare favorably to experimentally gathered data for four different optical configurations. The software developed for these calculations is freely available to predict the MTF of other coherent fiber bundle-based systems. Brief instructions and necessary assumptions/conditions are described.
- Open Access
- 1 September 2025
- Published by SPIE-Intl Soc Optical Eng in Optical Engineering
- Vol. 64 (09) , 090801-34
Lens design strategies for miniature scanning fiber endoscopes
The trend toward miniaturization of endoscopes is driven by demand for early disease detection, improved patient outcomes through minimally invasive technology, and the miniaturization needed for pediatric applications. Advances in imaging technology and materials allow the production of endoscopes enabling access to narrow or delicate anatomical areas with reduced invasiveness of procedures. However, as endoscope diameters decrease, challenges arise in the optical design of their imaging systems. Commercially available camera modules have miniaturized sufficiently to create “chip-on-tip” microendoscopes, which encapsulate the optical lens and imaging sensor in a small package at the distal end of an endoscope, requiring only electrical connections to be routed through the endoscope body. An example of one of these miniaturized camera modules is the OMNIVISION OV6948, which has a array of pixels, for a total of 40,000 pixels, with a diagonal length of 0.919 mm.1 Although these camera modules are well-equipped for some applications, they are not a comprehensive solution. For example, the number of pixels in these miniature camera modules may be insufficient for few-micron resolution imaging at multiple-millimeter field of view (FOV). In addition, the sensitivity of miniature CMOS sensors may be insufficient for imaging modalities with weak signals, such as autofluorescence imaging (AFI), in part because of the small pixel size. In some cases, camera modules are only available with fixed filters, which may reduce signal, and limit the number of pixels per image in sensitive, hyperspectral designs.2- 1 September 2025
- Published by SPIE-Intl Soc Optical Eng in Optical Engineering
- Vol. 64 (09) , 090801-34
Open AccessLens design strategies for miniature scanning fiber endoscopes
The trend toward miniaturization of endoscopes is driven by demand for early disease detection, improved patient outcomes through minimally invasive technology, and the miniaturization needed for pediatric applications. Advances in imaging technology and materials allow the production of endoscopes enabling access to narrow or delicate anatomical areas with reduced invasiveness of procedures. However, as endoscope diameters decrease, challenges arise in the optical design of their imaging systems. Commercially available camera modules have miniaturized sufficiently to create “chip-on-tip” microendoscopes, which encapsulate the optical lens and imaging sensor in a small package at the distal end of an endoscope, requiring only electrical connections to be routed through the endoscope body. An example of one of these miniaturized camera modules is the OMNIVISION OV6948, which has a array of pixels, for a total of 40,000 pixels, with a diagonal length of 0.919 mm.1 Although these camera modules are well-equipped for some applications, they are not a comprehensive solution. For example, the number of pixels in these miniature camera modules may be insufficient for few-micron resolution imaging at multiple-millimeter field of view (FOV). In addition, the sensitivity of miniature CMOS sensors may be insufficient for imaging modalities with weak signals, such as autofluorescence imaging (AFI), in part because of the small pixel size. In some cases, camera modules are only available with fixed filters, which may reduce signal, and limit the number of pixels per image in sensitive, hyperspectral designs.2 - Open Access
- 1 April 2024
- Published by SPIE-Intl Soc Optical Eng in Biophotonics Discovery
- Vol. 1 (01) , 015001-12
Optical coherence tomography for the detection of electrothermal ureteral injury in an ex-vivo porcine model
SignificanceThe current technology has limited ability to detect lateral thermal spread of injury caused by electrosurgical devices during gynecologic procedures.AimWe aim to assess the feasibility of endoscopic optical coherence tomography (OCT) to detect electrothermal ureteral damage.ApproachElectrothermal energy was externally applied to nine explanted porcine ureters. Three segments of each ureter were treated for 5 s at low (16 W), medium (26 W), and high (36 W) powers (n=27 segments). Volumetric OCT images were acquired using a swept source OCT laser endomicroscopy system. OCT datasets were visually inspected for characterization of normal and electrothermally injured tissue architecture. Ground-truth comparisons were made with histology to validate the presence of lesions and to compare lesion size measurements using Pearson’s correlation coefficient. Three physicians were trained to identify OCT images of normal and injured ureters. Physician lesion detection accuracy was tested with 126 OCT images (63 normal and 63 injured). The effect of treatment power on lesion length as measured with OCT was compared using a one-way analysis of variance.ResultsTransmural electrothermal injury was identified on OCT images for all but one histology-confirmed lesion (22/23, 95.7%). The average sensitivity and specificity for physician lesion detection were 82% and 96%, respectively. The mean lesion size measured on OCT was 3.6±1.9, 4.4±1.3, and 7.0±2.9 mm for low, medium, and high powers, respectively (p=0.024). A comparison of lesion size measured on OCT and histology revealed a moderate positive correlation (r=0.65, p=0.00087).ConclusionsEndoscopic OCT could fulfill the unmet clinical need for the timely detection of electrothermal ureteral injury.
- 1 April 2024
- Published by SPIE-Intl Soc Optical Eng in Biophotonics Discovery
- Vol. 1 (01) , 015001-12
Open AccessOptical coherence tomography for the detection of electrothermal ureteral injury in an ex-vivo porcine model
SignificanceThe current technology has limited ability to detect lateral thermal spread of injury caused by electrosurgical devices during gynecologic procedures.AimWe aim to assess the feasibility of endoscopic optical coherence tomography (OCT) to detect electrothermal ureteral damage.ApproachElectrothermal energy was externally applied to nine explanted porcine ureters. Three segments of each ureter were treated for 5 s at low (16 W), medium (26 W), and high (36 W) powers (n=27 segments). Volumetric OCT images were acquired using a swept source OCT laser endomicroscopy system. OCT datasets were visually inspected for characterization of normal and electrothermally injured tissue architecture. Ground-truth comparisons were made with histology to validate the presence of lesions and to compare lesion size measurements using Pearson’s correlation coefficient. Three physicians were trained to identify OCT images of normal and injured ureters. Physician lesion detection accuracy was tested with 126 OCT images (63 normal and 63 injured). The effect of treatment power on lesion length as measured with OCT was compared using a one-way analysis of variance.ResultsTransmural electrothermal injury was identified on OCT images for all but one histology-confirmed lesion (22/23, 95.7%). The average sensitivity and specificity for physician lesion detection were 82% and 96%, respectively. The mean lesion size measured on OCT was 3.6±1.9, 4.4±1.3, and 7.0±2.9 mm for low, medium, and high powers, respectively (p=0.024). A comparison of lesion size measured on OCT and histology revealed a moderate positive correlation (r=0.65, p=0.00087).ConclusionsEndoscopic OCT could fulfill the unmet clinical need for the timely detection of electrothermal ureteral injury.
- Open Access
- 12 August 2023
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 28 (12) , 121206-15
Iterative prototyping based on lessons learned from the falloposcope in vivo pilot study experience
Ovarian cancer is the most deadly gynecological malignancy and is the fifth leading cause of cancer-related mortality in the United States in females, with incidence and mortality rates expected to be 19,880 and 12,810, respectively, in 2022. The early detection of ovarian cancer could double the 5-year survival rate compared with late-stage diagnosis (93% to 98% versus 31% to 45%, respectively).1,2 Recent evidence suggests that the molecular pathogenesis of high-grade serous ovarian cancer begins in the fallopian tubes (FT), prior to the onset of symptoms.3 – 5 Thus, there is an unmet clinical need for the earlier detection of pathological changes in the FTs. There is currently no generally acceptable screening method for ovarian cancer. Surveillance by annual concurrent transvaginal ultrasound and serum CA125 measurements are alternatives offered to women at very high risk for ovarian cancer who decline prophylactic salpingo-oophorectomy. Studies have revealed that this combination may be helpful but is insufficient, as only 50% to 60% of cases are diagnosed at early stages in these women and this method of screening is not recommended for women at average risk.6 – 10
- 12 August 2023
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 28 (12) , 121206-15
Open AccessIterative prototyping based on lessons learned from the falloposcope in vivo pilot study experience
Ovarian cancer is the most deadly gynecological malignancy and is the fifth leading cause of cancer-related mortality in the United States in females, with incidence and mortality rates expected to be 19,880 and 12,810, respectively, in 2022. The early detection of ovarian cancer could double the 5-year survival rate compared with late-stage diagnosis (93% to 98% versus 31% to 45%, respectively).1,2 Recent evidence suggests that the molecular pathogenesis of high-grade serous ovarian cancer begins in the fallopian tubes (FT), prior to the onset of symptoms.3 – 5 Thus, there is an unmet clinical need for the earlier detection of pathological changes in the FTs. There is currently no generally acceptable screening method for ovarian cancer. Surveillance by annual concurrent transvaginal ultrasound and serum CA125 measurements are alternatives offered to women at very high risk for ovarian cancer who decline prophylactic salpingo-oophorectomy. Studies have revealed that this combination may be helpful but is insufficient, as only 50% to 60% of cases are diagnosed at early stages in these women and this method of screening is not recommended for women at average risk.6 – 10
- Open Access
- 1 January 2023
- Published by SPIE-Intl Soc Optical Eng in Journal of Optical Microsystems
- Vol. 3 (01) , 011003-11
Characterizing close-focus lenses for microendoscopy
Minimally invasive endoscopic imaging offers the opportunity for early detection of cancer and other disease states by bringing powerful optical techniques to the interior of the body. For ex- ample, in one study colonoscopy was associated with a 61% reduction in colon cancer mortality among veterans.1 However, the colon has a large lumen, accommodating endoscopes of around 12 mm in diameter, which typically includes imaging lenses in the 2- to 3-mm-diameter range. The desire to extend minimally invasive clinical imaging to organs with smaller lumens, such as the pancreas,2 fallopian tube,3 bronchioles,4 or guiding needle biopsies of the lungs5 or during neurosurgery,6 has necessitated the development of microendoscopes that are submillimeter in diameter. These endoscopes may contain one or more imaging modalities and possibly other functionalities, such as cell/tissue collection, laser therapy, or drug delivery. In these microendoscopes, optical channel diameters are limited to the 100- to -diameter range. The small lumens themselves define a new set of challenges that drive specialized lens requirements. Typical endoscope optics for large cavities or lumens have moderate to large angular fields of view (AFOV) and are designed for operation in an air or insufflation gas environment and focused at the hyperfocal distance, from a few millimeters to infinity. However, small lumens may be collapsed and filled with mucus, cilia, or plicae. Therefore, it is more likely that microendoscopes will need moderate AFOV, depth of field (DOF) from less than a millimeter to a few millimeters, and ability to operate in an environment where 0.9% saline is used for flushing and irrigation as an immersion objective. We are particularly interested in distal optic systems of 0.5 mm or less in diameter that can operate in these cramped aqueous environments.- 1 January 2023
- Published by SPIE-Intl Soc Optical Eng in Journal of Optical Microsystems
- Vol. 3 (01) , 011003-11
Open AccessCharacterizing close-focus lenses for microendoscopy
Minimally invasive endoscopic imaging offers the opportunity for early detection of cancer and other disease states by bringing powerful optical techniques to the interior of the body. For ex- ample, in one study colonoscopy was associated with a 61% reduction in colon cancer mortality among veterans.1 However, the colon has a large lumen, accommodating endoscopes of around 12 mm in diameter, which typically includes imaging lenses in the 2- to 3-mm-diameter range. The desire to extend minimally invasive clinical imaging to organs with smaller lumens, such as the pancreas,2 fallopian tube,3 bronchioles,4 or guiding needle biopsies of the lungs5 or during neurosurgery,6 has necessitated the development of microendoscopes that are submillimeter in diameter. These endoscopes may contain one or more imaging modalities and possibly other functionalities, such as cell/tissue collection, laser therapy, or drug delivery. In these microendoscopes, optical channel diameters are limited to the 100- to -diameter range. The small lumens themselves define a new set of challenges that drive specialized lens requirements. Typical endoscope optics for large cavities or lumens have moderate to large angular fields of view (AFOV) and are designed for operation in an air or insufflation gas environment and focused at the hyperfocal distance, from a few millimeters to infinity. However, small lumens may be collapsed and filled with mucus, cilia, or plicae. Therefore, it is more likely that microendoscopes will need moderate AFOV, depth of field (DOF) from less than a millimeter to a few millimeters, and ability to operate in an environment where 0.9% saline is used for flushing and irrigation as an immersion objective. We are particularly interested in distal optic systems of 0.5 mm or less in diameter that can operate in these cramped aqueous environments. - Open Access
- 17 December 2021
- Published by SPIE-Intl Soc Optical Eng in Journal of Optical Microsystems
- Vol. 1 (04) , 044502-20
Triple-modality co-registered endoscope featuring wide-field reflectance imaging, and high-resolution multiphoton and optical coherence microscopy
It is estimated that cancer affects about 450 per 100,000 people in the United States alone.1 Cancer detection at early stages is critical to a patient’s outcome since cancer is localized and is most responsive to treatment at the early stages. Unfortunately, detecting localized precancerous lesions is difficult due to the lack of symptoms and the microscopic size of early neoplastic lesions. Making a definitive diagnosis with histology requires a destructive surgical biopsy that can miss the affected tissue area. Therefore, a faster and less invasive detection method that can survey more tissue is desired to make the process efficient and accurate. Optical imaging has been proven to detect several types of early cancer effectively. Furthermore, multimodal optical imaging may provide improved classification accuracy.2 Research teams, including ours, have been developing novel endoscopes that feature dual-modality imaging to reach internal organs.3 – 6 A multimodal endoscope might detect precancerous lesions and reduce unnecessary biopsies.
- 17 December 2021
- Published by SPIE-Intl Soc Optical Eng in Journal of Optical Microsystems
- Vol. 1 (04) , 044502-20
Open AccessTriple-modality co-registered endoscope featuring wide-field reflectance imaging, and high-resolution multiphoton and optical coherence microscopy
It is estimated that cancer affects about 450 per 100,000 people in the United States alone.1 Cancer detection at early stages is critical to a patient’s outcome since cancer is localized and is most responsive to treatment at the early stages. Unfortunately, detecting localized precancerous lesions is difficult due to the lack of symptoms and the microscopic size of early neoplastic lesions. Making a definitive diagnosis with histology requires a destructive surgical biopsy that can miss the affected tissue area. Therefore, a faster and less invasive detection method that can survey more tissue is desired to make the process efficient and accurate. Optical imaging has been proven to detect several types of early cancer effectively. Furthermore, multimodal optical imaging may provide improved classification accuracy.2 Research teams, including ours, have been developing novel endoscopes that feature dual-modality imaging to reach internal organs.3 – 6 A multimodal endoscope might detect precancerous lesions and reduce unnecessary biopsies.