JSJan Sobesky

Jan Sobesky

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Jan Sobesky has a total of 93 co-authors. Here are the top co-authors by number of shared publications:

  • Vince Istvan Madai

    Berlin Institute of Health at Charité-Universitätsmedizin Berlin, Berlin, Germany

    10 shared publications
  • Michelle Livne

    CLAIM - Charité Lab for AI in Medicine, Charité Universitätsmedizin Berlin, Germany

    4 shared publications
  • Steve Zacharias Martin

    Center for Stroke Research Berlin (CSB), Charité-Universitätsmedizin, Berlin, Germany

    4 shared publications
  • Walter Moeller-Hartmann

    From the Center for Stroke Research Berlin (CSB) (M.L., T.K., V.I.M., J.S.), and Department of Neurosurgery (V.I.M.), Charité-Universitätsmedizin Berlin, Germany; Max-Planck-Institute for Neurological Research, Cologne, Germany (O.Z.-W., W.-D.H.); Department of Radiology, Ludmillenstift Meppen, Germany (W.M.-H.); and Center of Functionally Integrative Neuroscience, Aarhus University, Denmark (K.M.).

    4 shared publications
  • Federico C. von Samson-Himmelstjerna

    From the Max-Planck-Institute for Metabolism Research, Cologne, Germany (O.Z.-W., A.S., W.-D.H.); Center for Stroke Research Berlin (CSB) (M.L., S.Z.M., F.C.v.S.-H., P.B., J.S., V.I.M.) and Department of Neurology (J.S., V.I.M.), Charité-Universitätsmedizin, Berlin, Germany; Fraunhofer MEVIS, Bremen, Germany (F.C.v.S.-H.); Department of Radiology, Ludmillenstift, Meppen, Germany (W.M.-H.); and Max-Planck-Institute for Neurological Research, Cologne, Germany (O.Z.-W., A.S., W.-D.H.).

    3 shared publications
  • Jochen B. Fiebach

    Centre for Stroke Research Berlin, Charité Universitätsmedizin Berlin, Berlin, Germany

    3 shared publications

Latest Publications

  • Open Access

    Early Complications After Mild to Moderate Ischemic Stroke and Impact on 3‐Month Outcome: The Multicenter Prospective Stroke Unit Plus Cohort Study

    by Jan Sobesky, Vince Istvan Madai, Sarah Zweynert, Carolin Malsch, Darius Guenther Nabavi, Heinrich J. Audebert, Christoph Kleinschnitz, Bruno Marcel Mackert, Bettina Schmitz, Frank Arne Wollenweber, et al.

    Background: Early stroke complications (ESCs) impair recovery and provide an important therapeutic target. Our multicenter prospective cohort study examined the prevalence and amount of poor outcomes attributable to ESCs. Methods and Results: In patients with stroke, 16 ESCs were monitored by clinical assessment (“basic definition”) and by inclusion of laboratory values and clinical scales (“extended definition”). The association of complications with poor outcome (death or functional impairment: modified Rankin Scale score >3 or Barthel Index <60) at 3 months was analyzed using multiple logistic regression adjusted for stroke severity, age, and sex. Complications were stratified by their early treatment options, and average sequential population‐attributable fractions were estimated for treatable early complications. Of 1202 patients, outcome data were available for 1105 (91.9%; 43.0% women; mean age 68.3 years; baseline median National Institutes of Health Stroke Scale score on admission 3 points). Poor outcome was recorded for 100 patients (9.0%). By basic definition, recurrent stroke, fever, pneumonia, depression, urinary tract infection, and delirium were significantly associated with poor outcomes. The occurrence of 1 or more of these ESCs was associated with up to 19.6% of poor outcomes. By extended definition, urinary tract infection, depression, and delirium were significantly associated with poor outcomes. The occurrence of 1 or more of these ESCs was associated with up to 15.9% of poor outcomes. Conclusions: In our cohort of patients with mild to moderate stroke, we identified a set of treatable ESCs with clinically relevant impact on outcome that may be targeted in future interventional trials. Registration: URL: https://www.bfarm.de ; Unique identifier: DRKS00004712.


  • Open Access

    A Precision Medicine Framework for Personalized Simulation of Hemodynamics in Cerebrovascular Disease

    by Dietmar Frey, Michelle Livne, Heiko Leppin, Ela M Akay, Orhun U Aydin, Jonas Behland, Jan Sobesky, Peter Vajkoczy, Vince I Madai

    Introduction: Cerebrovascular disease is a major public health challenge. An important biomarker is cerebral hemodynamics. To measure cerebral hemodynamics, however, only invasive, potentially harmful or time-to-treatment prolonging methods are available. We present a simulation-based alternative which allows calculation of cerebral hemodynamics based on the individual vessel con figuration of a patient derived from structural vessel imaging. Methods: We implemented a framework allowing annotation of extracted brain vessels from structural imaging followed by 0-dimensional lumped modelling of cerebral hemodynamics. For annotation, a 3D-graphical user interface (GUI) was implemented. For 0D-simulation, we used a modified nodal analysis (MNA), which was adapted for easy implementation by code. The code was written in-house in java. The simulation GUI allows inspection of simulation results, identification of vulnerable areas, simulation of changes due to different systemic blood pressures. Moreover, sensitivity analysis was implemented allowing the live simulation of changes of variables such as vessel lumen to simulate procedures and disease courses. In two exemplary patients, simulation results were compared to dynamic-susceptibility-weighted-contrast-enhanced magnetic- resonance(DSC-MR) perfusion imaging. Results: The successful implementation of the framework allowing individualized annotation and simulation of patients is presented. In two exemplary patients, both the simulation as well as DSC- MRI showed the same results pertaining to the identification of areas vulnerable to ischemia. Sensitivity analysis allows the individualized simulation of changes in vessel lumen and the effect on hemodynamics. Discussion: We present the first precision medicine pipeline for cerebrovascular disease which allows annotation of the arterial vasculature derived from structural vessel imaging followed by personalized simulation of brain hemodynamics. This paves the way for further development of precision medicine in stroke using novel biomarkers and might make the application of harmful and complex perfusion methods obsolete for certain use cases in the future.


  • Multiparametric Model for Penumbral Flow Prediction in Acute Stroke

    by Michelle Livne, Tabea Kossen, Vince I. Madai, Olivier Zaro-Weber, Walter Moeller-Hartmann, Kim Mouridsen, Wolf-Dieter Heiss, Jan Sobesky

    Background and Purpose—: Identification of salvageable penumbra tissue by dynamic susceptibility contrast magnetic resonance imaging is a valuable tool for acute stroke patient stratification for treatment. However, prior studies have not attempted to combine the different perfusion maps into a predictive model. In this study, we established a multiparametric perfusion imaging model and cross-validated it using positron emission tomography perfusion for detection of penumbral flow. Methods—: In a retrospective analysis of 17 subacute stroke patients with consecutive magnetic resonance imaging and H2O15 positron emission tomography scans, perfusion maps of cerebral blood flow, cerebral blood volume, mean transit time, time-to-maximum, and time-to-peak were constructed and combined using a generalized linear model (GLM). Both the GLM maps and the single perfusion maps alone were cross-validated with positron emission tomography-cerebral blood flow scans to predict penumbral flow on a voxel-wise level. Performance was tested by receiver-operating characteristics curve analysis, that is, the area under the curve, and the models’ fits were compared using the likelihood ratio test. Results—: The GLM demonstrated significantly improved model fit compared with each of the single perfusion maps ( P <1×e-5) and demonstrated higher performance, with an area under the curve of 0.91. However, the absolute difference between the performance of GLM and the best-performing single perfusion parameter (time-to-maximum) was relatively low (area under the curve difference =0.04). Conclusions—: Our results support a dynamic susceptibility contrast magnetic resonance imaging–based GLM as an improved model for penumbral flow prediction in stroke patients. With given perfusion maps, this model is a straightforward and observer-independent alternative for therapy stratification.


  • A PET‐Guided Framework Supports a Multiple Arterial Input Functions Approach in DSC‐MRI in Acute Stroke

    by Michelle Livne, Vince I. Madai, Peter Brunecker, Olivier Zaro‐Weber, Walter Moeller‐Hartmann, Wolf‐Dieter Heiss, Kim Mouridsen, Jan Sobesky

    In acute stroke, arterial-input-function (AIF) determination is essential for obtaining perfusion estimates with dynamic susceptibility-weighted contrast-enhanced magnetic resonance imaging (DSC-MRI). Standard DSC-MRI postprocessing applies single AIF selection, ie, global AIF. Physiological considerations, however, suggest that a multiple AIFs selection method would improve perfusion estimates to detect penumbral flow. In this study, we developed a framework based on comparable DSC-MRI and positron emission tomography (PET) images to compare the two AIF selection approaches and assess their performance in penumbral flow detection in acute stroke. In a retrospective analysis of 17 sub(acute) stroke patients with consecutive MRI and PET scans, voxel-wise optimized AIFs were calculated based on the kinetic model as derived from both imaging modalities. Perfusion maps were calculated based on the optimized-AIF using two methodologies: (1) Global AIF and (2) multiple AIFs as identified by cluster analysis. Performance of penumbral-flow detection was tested by receiver–operating characteristics (ROC) curve analysis, ie, the area under the curve (AUC). Large variation of optimized AIFs across brain voxels demonstrated that there is no optimal single AIF. Subsequently, the multiple-AIF method (AUC range over all maps: .82-.90) outperformed the global AIF methodology (AUC .72-.85) significantly. We provide PET imaging-based evidence that a multiple AIF methodology is beneficial for penumbral flow detection in comparison with the standard global AIF methodology in acute stroke.


  • Open Access

    Comparison of the 2 Most Popular Deconvolution Techniques for the Detection of Penumbral Flow in Acute Stroke

    by Olivier Zaro-Weber, Michelle Livne, Steve Z. Martin, Federico C. von Samson-Himmelstjerna, Walter Moeller-Hartmann, Alexander Schuster, Peter Brunecker, Wolf-Dieter Heiss, Jan Sobesky, Vince I. Madai

    Background and Purpose—Dynamic susceptibility–weighted contrast–enhanced (DSC) magnetic resonance imaging (MRI) is used to identify the tissue-at-risk in acute stroke, but the choice of optimal DSC postprocessing in the clinical setting remains a matter of debate. Using 15O-water positron emission tomography (PET), we validated the performance of 2 common deconvolution methods for DSC-MRI. Methods—In (sub)acute stroke patients with consecutive MRI and PET imaging, DSC maps were calculated applying 2 deconvolution methods, standard and block-circulant single value decomposition. We used 2 standardized analysis methods, a region of interest–based and a voxel-based analysis, where PET cerebral blood flow masks of Results—In 18 data sets (median time after stroke onset: 18 hours; median time PET to MRI: 101 minutes), block-circulant single value decomposition showed significantly better performance to detect PET penumbral flow only for mean transit time maps. Time-to-maximum (Tmax) had the highest performance independent of the deconvolution method. Conclusions—Block-circulant single value decomposition seems only significantly beneficial for mean transit time maps in (sub)acute stroke. Tmax is likely the most stable deconvolved parameter for the detection of tissue-at-risk using DSC-MRI.


  • Leaving the Black Box Approach: Individualized Prediction of Recanalization Benefit by Advanced Imaging in Acute Stroke

    by Jan Sobesky

    The enthusiasm about mechanical recanalization in acute stroke has experienced a ‘state of hibernation’ due to inconclusive studies several years ago but has now been ‘reperfused’ by overwhelming evidence from recent randomized trials.1, 2, 3 On the one hand, the short message delivered by these studies is the following: recanalization is beneficial if early and complete. This is not a surprising finding for the stroke community but it is well embedded in a clinical setting.


  • Open Access

    3D GRASE Pulsed Arterial Spin Labeling at Multiple Inflow Times in Patients with Long Arterial Transit Times: Comparison with Dynamic Susceptibility-Weighted Contrast-Enhanced MRI at 3 Tesla

    by Steve Z Martin, Vince I Madai, Federico C von Samson-Himmelstjerna, Matthias A Mutke, Miriam Bauer, Cornelius X Herzig, Stefan Hetzer, Matthias Günther, Jan Sobesky

    Pulsed arterial spin labeling (PASL) at multiple inflow times (multi-TIs) is advantageous for the measurement of brain perfusion in patients with long arterial transit times (ATTs) as in steno-occlusive disease, because bolus-arrival-time can be measured and blood flow measurements can be corrected accordingly. Owing to its increased signal-to-noise ratio, a combination with a three-dimensional gradient and spin echo (GRASE) readout allows acquiring a sufficient number of multi-TIs within a clinically feasible acquisition time of 5 minutes. We compared this technique with the clinical standard dynamic susceptibility-weighted contrast-enhanced imaging—magnetic resonance imaging in patients with unilateral stenosis >70% of the internal carotid or middle cerebral artery (MCA) at 3 Tesla. We performed qualitative (assessment by three expert raters) and quantitative (region of interest (ROI)/volume of interest (VOI) based) comparisons. In 43 patients, multi-TI PASL-GRASE showed perfusion alterations with moderate accuracy in the qualitative analysis. Quantitatively, moderate correlation coefficients were found for the MCA territory (ROI based: r=0.52, VOI based: r=0.48). In the anterior cerebral artery (ACA) territory, a readout related right-sided susceptibility artifact impaired correlation (ROI based: r=0.29, VOI based: r=0.34). Arterial transit delay artifacts were found only in 12% of patients. In conclusion, multi-TI PASL-GRASE can correct for arterial transit delay in patients with long ATTs. These results are promising for the transfer of ASL to the clinical practice.


  • Open Access

    DWI Intensity Values Predict FLAIR Lesions in Acute Ischemic Stroke

    by Vince I. Madai, Ivana Galinovic, Ulrike Grittner, Olivier Zaro-Weber, Alice Schneider, Steve Z. Martin, Federico C. V. Samson-Himmelstjerna, Katharina L. Stengl, Matthias A. Mutke, Walter Moeller-Hartmann, et al.

    In acute stroke, the DWI-FLAIR mismatch allows for the allocation of patients to the thrombolysis window (<4.5 hours). FLAIR-lesions, however, may be challenging to assess. In comparison, DWI may be a useful bio-marker owing to high lesion contrast. We investigated the performance of a relative DWI signal intensity (rSI) threshold to predict the presence of FLAIR-lesions in acute stroke and analyzed its association with time-from-stroke-onset. In a retrospective, dual-center MR-imaging study we included patients with acute stroke and time-from-stroke-onset ≤12 hours (group A: n = 49, 1.5T; group B: n = 48, 3T). DW- and FLAIR-images were coregistered. The largest lesion extent in DWI defined the slice for further analysis. FLAIR-lesions were identified by 3 raters, delineated as regions-of-interest (ROIs) and copied on the DW-images. Circular ROIs were placed within the DWI-lesion and labeled according to the FLAIR-pattern (FLAIR+ or FLAIR−). ROI-values were normalized to the unaffected hemisphere. Adjusted and nonadjusted receiver-operating-characteristics (ROC) curve analysis on patient level was performed to analyze the ability of a DWI- and ADC-rSI threshold to predict the presence of FLAIR-lesions. Spearman correlation and adjusted linear regression analysis was performed to assess the relationship between DWI-intensity and time-from-stroke-onset. DWI-rSI performed well in predicting lesions in FLAIR-imaging (mean area under the curve (AUC): group A: 0.84; group B: 0.85). An optimal mean DWI-rSI threshold was identified (A: 162%; B: 161%). ADC-maps performed worse (mean AUC: A: 0.58; B: 0.77). Adjusted regression models confirmed the superior performance of DWI-rSI. Correlation coefficents and linear regression showed a good association with time-from-stroke-onset for DWI-rSI, but not for ADC-rSI. An easily assessable DWI-rSI threshold identifies the presence of lesions in FLAIR-imaging with good accuracy and is associated with time-from-stroke-onset in acute stroke. This finding underlines the potential of a DWI-rSI threshold as a marker of lesion age.


  • Open Access

    Clinical Evaluation of an Arterial-Spin-Labeling Product Sequence in Steno-Occlusive Disease of the Brain

    by Matthias A. Mutke, Vince I. Madai, Federico C. von Samson-Himmelstjerna, Olivier Zaro Weber, Gajanan S. Revankar, Steve Z. Martin, Katharina L. Stengl, Miriam Bauer, Stefan Hetzer, Matthias Günther, et al.

    In brain perfusion imaging, arterial spin labeling (ASL) is a noninvasive alternative to dynamic susceptibility contrast-magnetic resonance imaging (DSC-MRI). For clinical imaging, only product sequences can be used. We therefore analyzed the performance of a product sequence (PICORE-PASL) included in an MRI software-package compared with DSC-MRI in patients with steno-occlusion of the MCA or ICA >70%. Images were acquired on a 3T MRI system and qualitatively analyzed by 3 raters. For a quantitative analysis, cortical ROIs were placed in co-registered ASL and DSC images. Pooled data for ASL-cerebral blood flow (CBF) and DSC-CBF were analyzed by Spearman’s correlation and the Bland-Altman (BA)-plot. In 28 patients, 11 ASL studies were uninterpretable due to patient motion. Of the remaining patients, 71% showed signs of delayed tracer arrival. A weak correlation for DSC-relCBF vs ASL-relCBF (r = 0.24) and a large spread of values in the BA-plot owing to unreliable CBF-measurement was found. The PICORE ASL product sequence is sensitive for estimation of delayed tracer arrival, but cannot be recommended to measure CBF in steno-occlusive disease. ASL-sequences that are less sensitive to patient motion and correcting for delayed blood flow should be available in the clinical setting.


  • Acute interventional recanalisation of vertebrobasilar stenoses by angioplasty: complications and 12 months follow up

    by C. M. Kowoll, W. Moeller-Hartmann, G. R. Fink, W. F. Haupt, J. Sobesky

    Introduction In acute symptomatic vertebrobasilar artery stenosis, the use of mechanical recanalisation remains controversial. The complication rate of acute interventional recanalisation (aIR) has to be considered, as evidence from randomised trials is lacking. In a single centre retrospective case series, we here describe complications and outcome after aIR. Methods We retrospectively assessed aIR in a tertiary care centre and included the following parameters: indication for aIR, national institute of health stroke scale (NIHSS) score on admission, recanalisation by thrombolysis in myocardial infarction score (TIMI) grades, post-interventional complications, mortality, NIHSS and modified Rankin scale at follow-up and rate of restenosis. Results We identified 14 aIR (14 percutaneous transluminal angioplasty with or without stent implantation in 12 patients; 6/12 with thrombolysis; n = 6 vertebral artery, n = 8 basilar artery; 4 women, mean age 67 years). Mortality was 25 % (3/12) after 7 days and 42 % (5/12) after 12 months. In 12/14, interventions are complete (TIMI 3, 86 %), in 2/14, a partial recanalisation (TIMI 2, 14 %) was achieved. In one case, a peri-interventional fatal intracerebral haemorrhage occurred (1/12, 8 %). At late follow-up (mean 342 days), one re-occlusion (1/7, 14 %) and one recurrent stroke (1/12, 8 %) were observed. Conclusions In our single centre series of vertebrobasilar aIR recanalisation rate was high. However, procedural safety and clinical outcome varied considerably. The results of aIR need to be assessed in multicentric registers to define the procedural risk and outcome in the clinical setting.