Background and Purpose—Dynamic susceptibility–weighted contrast–enhanced (DSC) magnetic resonance imaging (MRI) is used to identify the tissue-at-risk in acute stroke, but the choice of optimal DSC postprocessing in the clinical setting remains a matter of debate. Using 15O-water positron emission tomography (PET), we validated the performance of 2 common deconvolution methods for DSC-MRI. Methods—In (sub)acute stroke patients with consecutive MRI and PET imaging, DSC maps were calculated applying 2 deconvolution methods, standard and block-circulant single value decomposition. We used 2 standardized analysis methods, a region of interest–based and a voxel-based analysis, where PET cerebral blood flow masks of Results—In 18 data sets (median time after stroke onset: 18 hours; median time PET to MRI: 101 minutes), block-circulant single value decomposition showed significantly better performance to detect PET penumbral flow only for mean transit time maps. Time-to-maximum (Tmax) had the highest performance independent of the deconvolution method. Conclusions—Block-circulant single value decomposition seems only significantly beneficial for mean transit time maps in (sub)acute stroke. Tmax is likely the most stable deconvolved parameter for the detection of tissue-at-risk using DSC-MRI.