G. Castiglione
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
G. Castiglione has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Grazia Grazzini
Screening Department, Cancer Prevention and Research Institute (ISPO), Florence, Italy
2 shared publications M. Zappa
2 shared publications- Tiziana Rubeca
Cancer Prevention and Research Institute (ISPO), Florence - Italy
2 shared publications A G Bonanomi
Diagnostic Imaging Unit CSPO, Viale A, Volta 171, Florence 50131, Italy
1 shared publication- Carmen Beatriz Visioli
Clinical Epidemiology Unit, ISPRO, Florence, Italy
1 shared publication - Cristina Sani
Regional Laboratory of Cancer Prevention, Institute for Cancer Research, Prevention and Clinical Network (ISPRO), 50139 Florence, Italy
1 shared publication
Latest Publications
- Open Access
- 24 April 2007
- Published by Springer Nature in British Journal of Cancer
- Vol. 96 (11) , 1750-1754
Sensitivity of latex agglutination faecal occult blood test in the Florence District population-based colorectal cancer screening programme
We evaluated the sensitivity for colorectal cancer (CRC) of the latex agglutination test (LAT), an immunochemical test routinely used in the Florence District screening programme since 2000. Sensitivity was calculated by the proportional interval cancer incidence method in a population of 27 503 consecutive subjects screened in 2000–2002, interval cancers being identified by linkage to the Tuscany Cancer Registry files. Sensitivity was calculated overall and by gender, age, time since last negative LAT, CRC site, and rank of screening. Overall 1- and 2-year sensitivity estimates were 80.7 and 71.5%, respectively, suggesting that faecal occult blood testing screening sensitivity may be suboptimal due to testing or programme quality problems. Increasing screening sensitivity might be achieved if the detection rate of advanced adenomas could be increased without unacceptable loss in specificity.
- 24 April 2007
- Published by Springer Nature in British Journal of Cancer
- Vol. 96 (11) , 1750-1754
Open AccessSensitivity of latex agglutination faecal occult blood test in the Florence District population-based colorectal cancer screening programme
We evaluated the sensitivity for colorectal cancer (CRC) of the latex agglutination test (LAT), an immunochemical test routinely used in the Florence District screening programme since 2000. Sensitivity was calculated by the proportional interval cancer incidence method in a population of 27 503 consecutive subjects screened in 2000–2002, interval cancers being identified by linkage to the Tuscany Cancer Registry files. Sensitivity was calculated overall and by gender, age, time since last negative LAT, CRC site, and rank of screening. Overall 1- and 2-year sensitivity estimates were 80.7 and 71.5%, respectively, suggesting that faecal occult blood testing screening sensitivity may be suboptimal due to testing or programme quality problems. Increasing screening sensitivity might be achieved if the detection rate of advanced adenomas could be increased without unacceptable loss in specificity.
- Open Access
- 1 February 2003
- Published by Elsevier in Annals of Oncology
- Vol. 14 (2) , 342-343
Debate on colorectal cancer screening by faecal occult blood
We read with great interest the debate on colorectal cancer (CRC) screening in volume 13 issue 1 of the Annals of Oncology [1]. As opinions in the debate are controversial we would like to contribute to the discussion on the basis of our experience.
- 1 February 2003
- Published by Elsevier in Annals of Oncology
- Vol. 14 (2) , 342-343
Open AccessDebate on colorectal cancer screening by faecal occult blood
We read with great interest the debate on colorectal cancer (CRC) screening in volume 13 issue 1 of the Annals of Oncology [1]. As opinions in the debate are controversial we would like to contribute to the discussion on the basis of our experience.
- Open Access
- 1 September 2002
- Published by SAGE Publications in Journal of Medical Screening
- Vol. 9 (3) , 99-103
Basic variables at different positivity thresholds of a quantitative immunochemical test for faecal occult blood
OBJECTIVES: Screening by faecal occult blood testing (FOBT) is effective in decreasing mortality and incidence of colorectal cancer (CRC). Immunochemical tests have proved to be more cost effective than guaiac FOBTs. The latex agglutination test (LAT) has the advantage of being a fully automated, quantitative test. The aim of this study is to interpret the overall experience with LAT according to different positivity thresholds. SETTING: A population based screening programme is currently running involving subjects aged 50–70, invited every 2 years to have an FOBT. LAT is the standard screening test and has a positivity threshold for further diagnostic tests of 100 ng haemoglobin/ml of sample solution. METHODS: Positivity rates, detection rates for CRC high risk adenomas, and positive predictive values for CRC, high risk adenomas, and low risk adenomas were calculated for several positivity thresholds. RESULTS: 19 132 attendances at screening were recorded (11 774 at first screening, 7358 at subsequent screenings). Progressively increasing the positivity threshold from 100 to 200 ng/ml showed (a) a decrease in positivity rate; (b) a decrease in detection rates for CRC or high risk adenomas; (c) an increase in positive predictive values for cancer; (d) an increase in positive predictive value for high risk adenomas. CONCLUSIONS: Increasing the positivity threshold of the LAT reduces recall rate and improves positive predictive value for cancer or high risk adenomas but substantially decreases the detection rate of CRC and high risk adenomas. For this reason increasing the positivity cut off for LATs is not advisable. On the other hand decreasing the positivity threshold would increase recall rate and sensitivity of screening. Careful evaluation of sensitivity of the quantitative results of the LAT for interval cancers is needed to definitively assess the optimal positivity threshold for LATs in population based screening programmes.
- 1 September 2002
- Published by SAGE Publications in Journal of Medical Screening
- Vol. 9 (3) , 99-103
Open AccessBasic variables at different positivity thresholds of a quantitative immunochemical test for faecal occult blood
OBJECTIVES: Screening by faecal occult blood testing (FOBT) is effective in decreasing mortality and incidence of colorectal cancer (CRC). Immunochemical tests have proved to be more cost effective than guaiac FOBTs. The latex agglutination test (LAT) has the advantage of being a fully automated, quantitative test. The aim of this study is to interpret the overall experience with LAT according to different positivity thresholds. SETTING: A population based screening programme is currently running involving subjects aged 50–70, invited every 2 years to have an FOBT. LAT is the standard screening test and has a positivity threshold for further diagnostic tests of 100 ng haemoglobin/ml of sample solution. METHODS: Positivity rates, detection rates for CRC high risk adenomas, and positive predictive values for CRC, high risk adenomas, and low risk adenomas were calculated for several positivity thresholds. RESULTS: 19 132 attendances at screening were recorded (11 774 at first screening, 7358 at subsequent screenings). Progressively increasing the positivity threshold from 100 to 200 ng/ml showed (a) a decrease in positivity rate; (b) a decrease in detection rates for CRC or high risk adenomas; (c) an increase in positive predictive values for cancer; (d) an increase in positive predictive value for high risk adenomas. CONCLUSIONS: Increasing the positivity threshold of the LAT reduces recall rate and improves positive predictive value for cancer or high risk adenomas but substantially decreases the detection rate of CRC and high risk adenomas. For this reason increasing the positivity cut off for LATs is not advisable. On the other hand decreasing the positivity threshold would increase recall rate and sensitivity of screening. Careful evaluation of sensitivity of the quantitative results of the LAT for interval cancers is needed to definitively assess the optimal positivity threshold for LATs in population based screening programmes.
- 1 April 2001
- Vol. 92 (1) , 151-4
Measuring interval cancers in population-based screening using different assays of fecal occult blood testing: the District of Florence experience.
The fecal occult blood test (FOBT) has demonstrated its efficacy in reducing mortality from colorectal cancer (CRC). The guaiac-based FOBT has been criticized for its low sensitivity. In this study, two different assays for FOBT (guaiac or an immunochemical test based on reversed passive hemagglutination [RPHA]) were tested for comparison within a population-based screening program for colorectal cancer in the province of Florence (Italy). The proportional incidence method was used to calculate sensitivity for both FOBTs, according to rank of screening (first or repeat), age at entry (two groups of 50 to 59 and 60 to 70 years old) and lesion site (colon or rectum). When comparing FOBTs, the sensitivity multivariate Poisson regression was used to adjust for other variables. The sensitivity after the first 2 years was 50% (95% confidence interval [CI] 34% to 63%) for the guaiac test versus 82% (95% CI 67% to 92%) for RPHA. At multivariate analysis the risk of developing an interval cancer after a guaiac test is almost 3 times that after RPHA (rate ratio = 2.64; 95% CI 1.3 to 5.4). Our study confirms that RPHA is more sensitive than the guaiac test. The assumption that FOBT screening for CRC has to be based on a guaiac test should be reconsidered, and RPHA should be recommended as the standard FOBT for screening purposes.
- 1 April 2001
- Vol. 92 (1) , 151-4
Measuring interval cancers in population-based screening using different assays of fecal occult blood testing: the District of Florence experience.
The fecal occult blood test (FOBT) has demonstrated its efficacy in reducing mortality from colorectal cancer (CRC). The guaiac-based FOBT has been criticized for its low sensitivity. In this study, two different assays for FOBT (guaiac or an immunochemical test based on reversed passive hemagglutination [RPHA]) were tested for comparison within a population-based screening program for colorectal cancer in the province of Florence (Italy). The proportional incidence method was used to calculate sensitivity for both FOBTs, according to rank of screening (first or repeat), age at entry (two groups of 50 to 59 and 60 to 70 years old) and lesion site (colon or rectum). When comparing FOBTs, the sensitivity multivariate Poisson regression was used to adjust for other variables. The sensitivity after the first 2 years was 50% (95% confidence interval [CI] 34% to 63%) for the guaiac test versus 82% (95% CI 67% to 92%) for RPHA. At multivariate analysis the risk of developing an interval cancer after a guaiac test is almost 3 times that after RPHA (rate ratio = 2.64; 95% CI 1.3 to 5.4). Our study confirms that RPHA is more sensitive than the guaiac test. The assumption that FOBT screening for CRC has to be based on a guaiac test should be reconsidered, and RPHA should be recommended as the standard FOBT for screening purposes.