Etienne Dombre
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Etienne Dombre has a total of 47 co-authors. Here are the top co-authors by number of shared publications:
- Philippe Poignet
LIRMM, University of Montpellier, CNRS , 161 rue Ada, 34090 Montpellier , France
6 shared publications Philippe Poignet
LIRMM, UMR 5506, CNRS-Université Montpellier 2, Montpellier Cedex 05, France
3 shared publications- Arianna Menciassi
Scuola Superiore Sant’Anna, Pisa, Italy
2 shared publications - Benoît Herman
Institute of Mechanics, Materials and Civil Engineering, Université Catholique de Louvain (UCLouvain), 1348 Louvain-la-Neuve, Belgium
2 shared publications - Chao Liu
State Key Laboratory of Advanced Glass Materials, Wuhan University of Technology, Wuhan 430070, China
2 shared publications - Claude Durand
B+ Development, 1 traverse de la Penne, 13821 La Penne sur Huveaune FRANCE
2 shared publications
Latest Publications
- 9 April 2013
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 8 (6) , 977-987
Innovative endoscopic sino-nasal and anterior skull base robotics
Purpose Design a compact, ergonomic, and safe endoscope positioner dedicated to the sino-nasal tract, and the anterior and middle-stage skull base. Methods A motion and force analysis of the surgeon’s movement was performed on cadaver heads to gather objective data for specification purposes. An experimental comparative study was then performed with three different kinematics, again on cadaver heads, in order to define the best architecture satisfying the motion and force requirements. Results We quantified the maximal forces applied on the endoscope when traversing the sino-nasal tract in order to evaluate the forces that the robot should be able to overcome. We also quantified the minimal forces that should not be exceeded in order to avoid damaging vital structures. We showed that the entrance point of the endoscope into the nostril could not be considered, as in laparoscopic surgery, as a fixed point but rather as a fixed region whose location and dimensions depend on the targeted sinus. Conclusion From the safety and ergonomic points of view, the best solution would be a co-manipulated standard 6-degree of freedom robot to which is attached a gimbal-like passive remote manipulator holding the endoscope.
- 9 April 2013
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 8 (6) , 977-987
Innovative endoscopic sino-nasal and anterior skull base robotics
Purpose Design a compact, ergonomic, and safe endoscope positioner dedicated to the sino-nasal tract, and the anterior and middle-stage skull base. Methods A motion and force analysis of the surgeon’s movement was performed on cadaver heads to gather objective data for specification purposes. An experimental comparative study was then performed with three different kinematics, again on cadaver heads, in order to define the best architecture satisfying the motion and force requirements. Results We quantified the maximal forces applied on the endoscope when traversing the sino-nasal tract in order to evaluate the forces that the robot should be able to overcome. We also quantified the minimal forces that should not be exceeded in order to avoid damaging vital structures. We showed that the entrance point of the endoscope into the nostril could not be considered, as in laparoscopic surgery, as a fixed point but rather as a fixed region whose location and dimensions depend on the targeted sinus. Conclusion From the safety and ergonomic points of view, the best solution would be a co-manipulated standard 6-degree of freedom robot to which is attached a gimbal-like passive remote manipulator holding the endoscope.
- 1 January 2013
- Published by Springer Nature
- p. 121-130
A Case Study of Safety in the Design of Surgical Robots: The ARAKNES Platform
- 1 January 2013
- Published by Springer Nature
- p. 121-130
A Case Study of Safety in the Design of Surgical Robots: The ARAKNES Platform
- 1 January 2013
- Published by Springer Nature
- p. 323-332
A Case Study of Safety in the Design of Surgical Robots: The ARAKNES Platform
- 1 January 2013
- Published by Springer Nature
- p. 323-332
A Case Study of Safety in the Design of Surgical Robots: The ARAKNES Platform
- Open Access
- 15 December 2011
- Published by EDP Sciences in BIO Web of Conferences
- Vol. 1, 00090
Primary step for endoscopic sinonasal tract and anterior skull base robotics
- 15 December 2011
- Published by EDP Sciences in BIO Web of Conferences
- Vol. 1, 00090
Open AccessPrimary step for endoscopic sinonasal tract and anterior skull base robotics
- 30 June 2009
- Published by Elsevier in Journal of Minimally Invasive Gynecology
- Vol. 16 (3) , 344-349
Development and First In Vivo Trial of EvoLap, an Active Laparoscope Positioner
- 30 June 2009
- Published by Elsevier in Journal of Minimally Invasive Gynecology
- Vol. 16 (3) , 344-349
Development and First In Vivo Trial of EvoLap, an Active Laparoscope Positioner
- 1 January 2008
- Published by SAGE Publications in The International Journal of Robotics Research
- Vol. 27 (1) , 25-40
Ultrasound Image-Based Visual Servoing of a Surgical Instrument Through Nonlinear Model Predictive Control
Ultrasound image-guided interventions are widespread in surgery because of the non-invasive character of the procedures. However, hand/eye synchronization is relatively difficult for a surgeon. Ultrasound image-based visual servoing is one way to perform this kind of surgery. In this work, the control of instrument motion based on ultrasound images through nonlinear model predictive control is investigated. This new scheme ensures the convergence of the instrument to the desired position and also offers the possibility of satisfying constraints such as joint limits, actuator saturation and visibility preserving. This paper describes the proposed controller. The efficiency and the robustness of the proposed solution to control a six degree-of-freedom mechanical system is first illustrated by simulation. Experiments on a Mitsubishi PA10 robot highlight the efficiency of the vision control scheme to handle constraints of ultrasound image-based visual servoing.
- 1 January 2008
- Published by SAGE Publications in The International Journal of Robotics Research
- Vol. 27 (1) , 25-40
Ultrasound Image-Based Visual Servoing of a Surgical Instrument Through Nonlinear Model Predictive Control
Ultrasound image-guided interventions are widespread in surgery because of the non-invasive character of the procedures. However, hand/eye synchronization is relatively difficult for a surgeon. Ultrasound image-based visual servoing is one way to perform this kind of surgery. In this work, the control of instrument motion based on ultrasound images through nonlinear model predictive control is investigated. This new scheme ensures the convergence of the instrument to the desired position and also offers the possibility of satisfying constraints such as joint limits, actuator saturation and visibility preserving. This paper describes the proposed controller. The efficiency and the robustness of the proposed solution to control a six degree-of-freedom mechanical system is first illustrated by simulation. Experiments on a Mitsubishi PA10 robot highlight the efficiency of the vision control scheme to handle constraints of ultrasound image-based visual servoing.
- 1 April 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Proceedings 2001 ICRA. IEEE International Conference on Robotics and Automation (cat. No.01ch37164)
- No. 10504729,p. 927-933
Mechanical design of a new pneumatically driven underactuated hand
This paper presents a new pneumatically driven underactuated hand with two fingers and 3 phalanxes per finger. Two evidences have led the design of this hand. Firstly, the use of pneumatic energy facilitates the underactuation of the hand, indeed a single T-connector suffices to share out one input among two outputs. Secondly, non-backdrivable mechanisms have to be used in the transmission of phalanx's motion so that the hand is capable of producing form-closed grasps. This latter design principle is justified using a newly developed method that permits to study the form-closure property of a grasp exerted by an underactuated hand. Moreover, the intriguing ejection phenomenon is avoided thanks to non-backdrivable mechanisms that prohibit any backward motion of phalanxes when correctly positioned. An original mechanism called the "pneumatic parallelogram" is described, it enables the hand to perform fine pinch grasps. Finally, the optimal design of both fingers is addressed with respect to the force-isotropy of the finger and the positiveness of phalanx forces
- 1 April 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Proceedings 2001 ICRA. IEEE International Conference on Robotics and Automation (cat. No.01ch37164)
- No. 10504729,p. 927-933
Mechanical design of a new pneumatically driven underactuated hand
This paper presents a new pneumatically driven underactuated hand with two fingers and 3 phalanxes per finger. Two evidences have led the design of this hand. Firstly, the use of pneumatic energy facilitates the underactuation of the hand, indeed a single T-connector suffices to share out one input among two outputs. Secondly, non-backdrivable mechanisms have to be used in the transmission of phalanx's motion so that the hand is capable of producing form-closed grasps. This latter design principle is justified using a newly developed method that permits to study the form-closure property of a grasp exerted by an underactuated hand. Moreover, the intriguing ejection phenomenon is avoided thanks to non-backdrivable mechanisms that prohibit any backward motion of phalanxes when correctly positioned. An original mechanism called the "pneumatic parallelogram" is described, it enables the hand to perform fine pinch grasps. Finally, the optimal design of both fingers is addressed with respect to the force-isotropy of the finger and the positiveness of phalanx forces
- 1 October 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 454-459
Haptic Control Design for Robotic-Assisted Minimally Invasive Surgery
This paper discusses the design of a control system for robotic-assisted surgery with haptic feedback. The operational space control has a position-position teleopearation architecture with the phantom in the loop, enabling telepresence in free-space and contact. The null space control guarantees that surgical kinematic constraints are fulfilled. Both task and posture control run active observers (AOBs) in Cartesian domain, taking into account force, velocity and position signals. Experiments with a D2M2 (direct drive medical manipulator) robot are presented
- 1 October 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 454-459
Haptic Control Design for Robotic-Assisted Minimally Invasive Surgery
This paper discusses the design of a control system for robotic-assisted surgery with haptic feedback. The operational space control has a position-position teleopearation architecture with the phantom in the loop, enabling telepresence in free-space and contact. The null space control guarantees that surgical kinematic constraints are fulfilled. Both task and posture control run active observers (AOBs) in Cartesian domain, taking into account force, velocity and position signals. Experiments with a D2M2 (direct drive medical manipulator) robot are presented
- 9 March 2006
- Published by Springer Nature
- p. 217-226
Experimental Study of Dynamic Task / Posture Decoupling in Minimally Invasive Surgery Motions
- 9 March 2006
- Published by Springer Nature
- p. 217-226
Experimental Study of Dynamic Task / Posture Decoupling in Minimally Invasive Surgery Motions