UFUrsula Elisabeth Adriane Fittschen

Ursula Elisabeth Adriane Fittschen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ursula Elisabeth Adriane Fittschen has a total of 29 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Analysis of trace elements in airborne particulate matters collected in Ankara, Turkey by TXRF

    by Ilknur Durukan, Sema Bektas, Mehmet Dogan, Ursula E A Fittschen

    The main focus point of the presented study was the assessment of atmospheric burden of particulate matter and toxic trace metals in the atmosphere of Ankara, Turkey. For this purpose, outdoor samplings were accomplished in the capital city, Ankara. The types of filters, sample collection and sample preparation methods were investigated and optimized. Analyses were provided by the total reflection X-ray fluorescence (TXRF) spectroscopic technique in Germany. Spatial and temporal variations of air particulate matter (APM) levels in the city were examined. In some stations, APM sampled in according to their size distribution such as PM10 and PM2.5. Elemental characterization of size distributed PM were achieved and evaluated. It was detected that the elements mainly originated from soil in Beytepe station, from soil and solid fuel usage in Kayas station and from traffic and a variety of human activities in Sıhhiye station in air samplings. While the elements of natural origin observed in PM10 fraction, the elements from traffic and human activities were in PM2.5. Eventually, enrichment calculations were performed in order to identify the pollution sources.


  • Determination of phosphorus and other elements in atmospheric aerosols using synchrotron total‐reflection X‐ray fluorescence

    by Ursula E. A. Fittschen, Christina Streli, Florian Meirer, Matthias Alfeld

    In this study, P and other low Z elements were determined in aerosol particulates from ambient air using synchrotron radiation‐induced total‐reflection X‐ray fluorescence analysis. Atmospheric transport of nutrients such as P or Si to the oceans is a key factor to marine plankton growth. Concentration of these elements in marine air masses is generally low (P < 10 ng/m 3 ). Therefore, analytical procedures enabling for low detection limits are of interest. Because particle size is strongly correlated to its origin and sedimentation, the aerosols were collected with the aid of a low‐pressure Berner impactor, which separates the aerosol particulates in nine size fractions with the smallest fraction from 15 to 30 nm. To be able to determine low Z elements, measurements were performed under vacuum conditions at the FLUO beamline at the ANKA synchrotron. An excitation energy of 3.5 keV near the P K‐edge but below the Ca K absorption edge was chosen to avoid interferences of the P K‐line with the detector escape artifact of the Ca‐K α line. The result showed P was present in concentration from 2 to 180 ng/m 3 . Detection limits were found to be generally 0.2–0.3 ng/m 3 for a collecting time of 1 h for the aerosols, which is an improvement to detection limits reported in other studies. Other elements such as S, Cl, and Si were determined as well. Si like P is a nutrient for marine plankton (diatoms). S and Cl play an important role in cloud formation, e.g. polar stratospheric clouds. Copyright © 2013 John Wiley & Sons, Ltd.


  • Indoor Aerosol Determination with Respect to a Soiling Phenomenon in Private Residences

    by Ursula E. A. Fittschen, Manfred Santen, Andreas Rehmers, Ilknur Durukan, Martin Wesselmann

    Indoor aerosol exposure has become of major interest since health hazards arising from fine and ultrafine dust particles have become more evident. The study presented here is dedicated to fine and ultrafine dust characterization and determination in more than 150 private residences with special respect to a phenomenon of enhanced soiling. In the scientific community committed to ecological housing and building it is referred to as "black magic dust" though the staining is often film-like in nature. This phenomenon has been observed for 20 years in residences in Europe and North America and there is strong evidence that it is correlated to emission of semivolatile organic compounds (SVOCs) from refurbishing materials. In this study we show that fine dust particle concentrations are elevated in such homes and that there is characteristic particle morphology for "black magic dust" staining. From the results we suggest that elevated particle concentration and particle size are significant to induce a condensation process which causes the observed blackening. Reduced air exchanges due to new insulation standards may also contribute to its occurrence.


  • Confocal MXRF in environmental applications

    by Ursula Elisabeth Adriane Fittschen, Gerald Falkenberg

    In this review we highlight the performance of confocal micro X-ray fluorescence (CMXRF) for application in environmental science, citing contributions from recent studies (2008–2010). In CMXRF the use of focusing and collecting optics enables discrimination of the origin of fluorescence photons in three dimensions. It thereby enables simple and direct three dimensional imaging, and also the removal of unwanted signal contribution either from the depth of the sample or from its surface. By limiting the area of origin of fluorescence signal CMXRF can simplify quantitative approaches.


  • Picoliter Droplet Deposition Using a Prototype Picoliter Pipette: Control Parameters and Application in Micro X-ray Fluorescence

    by Ursula E. A. Fittschen, George J. Havrilla

    In this study, we introduce a Hewlett-Packard prototype picoliter pipette, the “thermal inkjet picofluidic system” (TIPS), for analytical purposes. In contrast to the use of actual inkjet printers, this instrument allows for control of all energy and time settings. We are able to show that in contrast to techniques delivering microliter and nanoliter volumes, evaporation has a major influence on the deposition of picoliter volumes and has to be treated seriously when picoliter depositions are applied in the laboratory for calibration purposes. We developed a strategy to reduce evaporation by varying different parameters, thereby achieving a precision of less than 10% for elemental depositions ranging from 1 to 300 picoliters and 1 to 2000 pg elemental deposits. Additionally, we determined the performance of the micro X-ray fluorescence (MXRF) instruments in terms of limit of detection (LODs), focal spot size, sensitivity, and precision and evaluated the TIPS deposits as reference materials for MXRF using single and multielement solutions. A linear response was observed with correlation coefficients from 0.991 to 0.999 for elemental deposits on AP1 film, and there was a standard deviation from 1 to 40%, depending on the element and the mass deposited. LOD’s for Ni deposits on AP1 films were found to range from low picogram levels to subpicogram levels. The dried deposits were characterized for size and shape using light microscopy and atomic force microscopy (AFM) to estimate matrix effects and the area covered with sample material for the MXRF analysis. Diameters from 14 to 39 μm and thicknesses from 200 nm to 2 μm were measured. The accuracy of the dried spot approach was demonstrated by comparing multielement deposits from the TIPS with the NIST SRMs 1833 and 1832 thin film standards for MXRF analysis. The deviation from the SRMs was found to be better than 10%.


  • Characteristics of Picoliter Droplet Dried Residues as Standards for Direct Analysis Techniques

    by Ursula E. A. Fittschen, Nicolas H. Bings, Stephan Hauschild, Stephan Förster, Arne F. Kiera, Ezer Karavani, Andreas Frömsdorf, Julian Thiele, Gerald Falkenberg

    The characteristics of dried residues of picodroplets of single-, two-, and three-element aqueous solutions, which qualify these as reference materials in the direct analysis of single particles, single cells, and other microscopic objects using, e.g., laser ablation inductively coupled plasma time-of-flight mass spectrometry (LA-ICP-TOF-MS) and micro-X-ray fluorescence (MXRF), were evaluated. Different single-, two-, and three-element solutions (0.01−1 g/L) were prepared in picoliter volume (around 130 pL) with a thermal inkjet printing technique. An achievable dosing precision of 4−15% was calculated by total reflection X-ray fluorescence (TXRF) determination of the transferred elemental mass of an array of 100 droplets. The size of the dried residues was determined by optical microscopy to be 5−20 μm in diameter depending on the concentration and the surface material. The elemental distribution of the dried residues was determined with synchrotron micro-X-ray fluorescence (SR-MXRF) analyses. The MXRF results show high uniformity for element deposition of every single droplet with an RSTD of 4−6% depending on the concentration of spotted solution. The shape and height profile of dried residues from picoliter droplets were studied using atomic force microscopy (AFM). It was found that these dry to give symmetrical spherical segments with maximum heights of 1.7 μm. The potential of this technique for direct LA-ICP-TOF-MS analysis is shown.