Ernest J. Feleppa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ernest J. Feleppa has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Jonathan Mamou
Riverside Res. Inst., New York, NY
8 shared publications - Junji Machi
University of Hawaii and Kuakini Medical Center
5 shared publications - Emi Saegusa-Beecroft
Dept. of General Surgery, Univ. of Hawaii and Kuakini Medical Ctr., Honolulu, HI
4 shared publications Eugene Yanagihara
Kuakini Medical Ctr., Dept. of Pathol., Honolulu, HI
4 shared publications- Michael L. Oelze
Department of Electrical and Computer Engineering, University of Illinois Urbana-Champaign, Champaign, IL 61801, USA
3 shared publications - Tadashi Yamaguchi
Ctr. for Frontier Medical Eng., Chiba Univ., Chiba, Japan
3 shared publications
Latest Publications
- 11 March 2015
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9323, 93231T
Quantitative photoacoustic assessment of ex-vivo lymph nodes of colorectal cancer patients
Staging of cancers and selection of appropriate treatment requires histological examination of multiple dissected lymph nodes (LNs) per patient, so that a staggering number of nodes require histopathological examination, and the finite resources of pathology facilities create a severe processing bottleneck. Histologically examining the entire 3D volume of every dissected node is not feasible, and therefore, only the central region of each node is examined histologically, which results in severe sampling limitations. In this work, we assess the feasibility of using quantitative photoacoustics (QPA) to overcome the limitations imposed by current procedures and eliminate the resulting under sampling in node assessments. QPA is emerging as a new hybrid modality that assesses tissue properties and classifies tissue type based on multiple estimates derived from spectrum analysis of photoacoustic (PA) radiofrequency (RF) data and from statistical analysis of envelope-signal data derived from the RF signals. Our study seeks to use QPA to distinguish cancerous from non-cancerous regions of dissected LNs and hence serve as a reliable means of imaging and detecting small but clinically significant cancerous foci that would be missed by current methods. Dissected lymph nodes were placed in a water bath and PA signals were generated using a wavelength-tunable (680-950 nm) laser. A 26-MHz, f-2 transducer was used to sense the PA signals. We present an overview of our experimental setup; provide a statistical analysis of multi-wavelength classification parameters (mid-band fit, slope, intercept) obtained from the PA signal spectrum generated in the LNs; and compare QPA performance with our established quantitative ultrasound (QUS) techniques in distinguishing metastatic from non-cancerous tissue in dissected LNs. QPA-QUS methods offer a novel general means of tissue typing and evaluation in a broad range of disease-assessment applications, e.g., cardiac, intravascular, musculoskeletal, endocrine-gland, etc.
- 11 March 2015
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9323, 93231T
Quantitative photoacoustic assessment of ex-vivo lymph nodes of colorectal cancer patients
Staging of cancers and selection of appropriate treatment requires histological examination of multiple dissected lymph nodes (LNs) per patient, so that a staggering number of nodes require histopathological examination, and the finite resources of pathology facilities create a severe processing bottleneck. Histologically examining the entire 3D volume of every dissected node is not feasible, and therefore, only the central region of each node is examined histologically, which results in severe sampling limitations. In this work, we assess the feasibility of using quantitative photoacoustics (QPA) to overcome the limitations imposed by current procedures and eliminate the resulting under sampling in node assessments. QPA is emerging as a new hybrid modality that assesses tissue properties and classifies tissue type based on multiple estimates derived from spectrum analysis of photoacoustic (PA) radiofrequency (RF) data and from statistical analysis of envelope-signal data derived from the RF signals. Our study seeks to use QPA to distinguish cancerous from non-cancerous regions of dissected LNs and hence serve as a reliable means of imaging and detecting small but clinically significant cancerous foci that would be missed by current methods. Dissected lymph nodes were placed in a water bath and PA signals were generated using a wavelength-tunable (680-950 nm) laser. A 26-MHz, f-2 transducer was used to sense the PA signals. We present an overview of our experimental setup; provide a statistical analysis of multi-wavelength classification parameters (mid-band fit, slope, intercept) obtained from the PA signal spectrum generated in the LNs; and compare QPA performance with our established quantitative ultrasound (QUS) techniques in distinguishing metastatic from non-cancerous tissue in dissected LNs. QPA-QUS methods offer a novel general means of tissue typing and evaluation in a broad range of disease-assessment applications, e.g., cardiac, intravascular, musculoskeletal, endocrine-gland, etc.
- 1 October 2014
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 136 (4_Suppleme) , 2157
250-MHz quantitative acoustic microscopy for assessing human lymph-node microstructure
- 1 October 2014
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 136 (4_Suppleme) , 2157
250-MHz quantitative acoustic microscopy for assessing human lymph-node microstructure
- 1 October 2014
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 136 (4_Suppleme) , 2123
Quantitative-ultrasound detection of cancer in human lymph nodes based on support vector machines
- 1 October 2014
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 136 (4_Suppleme) , 2123
Quantitative-ultrasound detection of cancer in human lymph nodes based on support vector machines
- 3 March 2014
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8943, 89432J
Spectrum analysis of photoacoustic signals for tissue classification
Quantitative ultrasound (QUS) estimates derived from power spectra of pulse-echo signals are sensitive to mi- crostructure and potentially can differentiate among tissues. However, QUS estimates do not provide molecular specificity. We investigated the feasibility of obtaining quantitative photoacoustic (QPA) estimates for sensi- tivity to microstructure and chromophores for tissue classification. QPA methods were tested using gel-based phantoms containing uniformly dispersed, black polyethylene spheres (1E5 particles/ml) with nominal mean diameters of 23.5, 29.5, 42.0, and 58.0 μm. A pulsed, 532-nm laser excited the photoacoustic (PA) response. A single-element, 34-MHz transducer with a 12-mm focal length was raster scanned over the phantom to acquire 3D PA data. Normalized power spectra were generated from the PA signals within 2079, moving (50% overlap), 1-mm-cube regions-of-interest (ROIs) to provide three QPA estimates: spectral slope (SS), spectral intercept (SI), and effective absorber size (EAS). SS and SI were computed using a linear-regression approximation to the normalized spectrum in the -6-dB band. EAS was computed by fitting the normalized spectrum in the -20-dB band to the multi-sphere analytical solution. All estimates were correlated with the size of particles dispersed in the phantoms. SS decreased while SI increased with an increase in particle size. EAS was correlated with nominal particle diameter, but particles aggregation and the finite bandwidth of the PAI system resulted in outliers. SS, SI, and EAS for the 23.5-μm-phantom were -0.14±-0.04 dB/MHz, 4.8±1.3 dB, and 25.4±6.3 μm, respectively; the corresponding values for the 58.0-μm phantom were -0.47±-0.03 dB/MHz, 15.6±0.9 dB, and 82.7±0.9 μm.
- 3 March 2014
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8943, 89432J
Spectrum analysis of photoacoustic signals for tissue classification
Quantitative ultrasound (QUS) estimates derived from power spectra of pulse-echo signals are sensitive to mi- crostructure and potentially can differentiate among tissues. However, QUS estimates do not provide molecular specificity. We investigated the feasibility of obtaining quantitative photoacoustic (QPA) estimates for sensi- tivity to microstructure and chromophores for tissue classification. QPA methods were tested using gel-based phantoms containing uniformly dispersed, black polyethylene spheres (1E5 particles/ml) with nominal mean diameters of 23.5, 29.5, 42.0, and 58.0 μm. A pulsed, 532-nm laser excited the photoacoustic (PA) response. A single-element, 34-MHz transducer with a 12-mm focal length was raster scanned over the phantom to acquire 3D PA data. Normalized power spectra were generated from the PA signals within 2079, moving (50% overlap), 1-mm-cube regions-of-interest (ROIs) to provide three QPA estimates: spectral slope (SS), spectral intercept (SI), and effective absorber size (EAS). SS and SI were computed using a linear-regression approximation to the normalized spectrum in the -6-dB band. EAS was computed by fitting the normalized spectrum in the -20-dB band to the multi-sphere analytical solution. All estimates were correlated with the size of particles dispersed in the phantoms. SS decreased while SI increased with an increase in particle size. EAS was correlated with nominal particle diameter, but particles aggregation and the finite bandwidth of the PAI system resulted in outliers. SS, SI, and EAS for the 23.5-μm-phantom were -0.14±-0.04 dB/MHz, 4.8±1.3 dB, and 25.4±6.3 μm, respectively; the corresponding values for the 58.0-μm phantom were -0.47±-0.03 dB/MHz, 15.6±0.9 dB, and 82.7±0.9 μm.
- 5 September 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 37-40
Three-dimensional quantitative high-frequency characterization of freshly-excised human lymph nodes
High-frequency quantitative ultrasound (QUS) permits characterization of tissue microstructure using system-independent estimates. In this study, freshly-excised lymph nodes from cancer patients were evaluated using specifically designed three-dimensional (3D) QUS methods. The long-term objective was to develop 3D QUS methods for detecting metastases. Detection of metastases is critically important for cancer staging and treatment planning. A custom laboratory scanning system was used to acquire radio-frequency (RF) data in 3D from excised lymph nodes using a 26-MHz center-frequency transducer. Overlapping 1-mm cylindrical regions-of-interest (ROIs) of the RF data were processed to yield 13 QUS estimates associated with tissue microstructure. QUS estimates were obtained from more than 250 nodes from more than 150 colorectal-, gastric-, and breast-cancer patients. Cancer-detection performance was assessed for individual estimates and linear combinations of estimates. ROC results demonstrated excellent classification. For colorectal- and gastric-cancer nodes, the areas under the ROC curves (AUCs) were above 0.94. Slightly poorer results (AUC 0.87) were obtained for breast nodes. Images based on QUS parameters also permitted localization of cancer foci in some micrometastatic cases. Therefore, these advanced 3D QUS methods potentially can be valuable for detecting small metastatic foci in dissected lymph nodes.
- 5 September 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 37-40
Three-dimensional quantitative high-frequency characterization of freshly-excised human lymph nodes
High-frequency quantitative ultrasound (QUS) permits characterization of tissue microstructure using system-independent estimates. In this study, freshly-excised lymph nodes from cancer patients were evaluated using specifically designed three-dimensional (3D) QUS methods. The long-term objective was to develop 3D QUS methods for detecting metastases. Detection of metastases is critically important for cancer staging and treatment planning. A custom laboratory scanning system was used to acquire radio-frequency (RF) data in 3D from excised lymph nodes using a 26-MHz center-frequency transducer. Overlapping 1-mm cylindrical regions-of-interest (ROIs) of the RF data were processed to yield 13 QUS estimates associated with tissue microstructure. QUS estimates were obtained from more than 250 nodes from more than 150 colorectal-, gastric-, and breast-cancer patients. Cancer-detection performance was assessed for individual estimates and linear combinations of estimates. ROC results demonstrated excellent classification. For colorectal- and gastric-cancer nodes, the areas under the ROC curves (AUCs) were above 0.94. Slightly poorer results (AUC 0.87) were obtained for breast nodes. Images based on QUS parameters also permitted localization of cancer foci in some micrometastatic cases. Therefore, these advanced 3D QUS methods potentially can be valuable for detecting small metastatic foci in dissected lymph nodes.
- 1 April 2011
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 129 (4_Suppleme) , 2610
Three-dimensional detection of metastases in freshly excised human lymph nodes using quantitative ultrasound backscatter and envelope parameters.
- 1 April 2011
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 129 (4_Suppleme) , 2610
Three-dimensional detection of metastases in freshly excised human lymph nodes using quantitative ultrasound backscatter and envelope parameters.
- 1 February 2011
- Published by Elsevier in Seminars in Oncology
- Vol. 38 (1) , 136-150
Quantitative Ultrasound in Cancer Imaging
- 1 February 2011
- Published by Elsevier in Seminars in Oncology
- Vol. 38 (1) , 136-150
Quantitative Ultrasound in Cancer Imaging
- 1 October 2008
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 124 (4_Suppleme) , 2445
Evaluation of a singular-spectrum analysis algorithm for detecting two types of brachytherapy seeds commonly used to treat prostate cancer.
- 1 October 2008
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 124 (4_Suppleme) , 2445
Evaluation of a singular-spectrum analysis algorithm for detecting two types of brachytherapy seeds commonly used to treat prostate cancer.
- 1 November 2007
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 122 (5_Suppleme) , 3008
Detection of brachytherapy seeds at varying angles with a singular-spectrum-analysis algorithm
A singular‐spectrum‐analysis (SSA) algorithm previously was shown to be successful in detecting brachytherapy seeds in B‐mode images when seeds were orthogonal to the ultrasound beam. In this study, the algorithm was extended to detect seeds at angles to the beam. The SSA algorithm derives P‐values from selected eigenvalue pairs of the autocorrelation matrix of seed echo signals. The P‐value indicates the probability of presence of a seed. A seed inserted in a gel pad and another inserted in beef tissue were scanned with a 5‐MHz transducer. The seed angle was varied from orthogonal to the beam to 23 deg from orthogonal, using 1‐degree increments. Simulations of seed echoes based on empirical data were generated and used to test the algorithm. Success in seed detection was expressed by a score computed from P‐values. Scores for simulations decreased from 0.8 to 0.45 as the angle increased from 0 to 12 deg. Scores for experimental data varied from 0.74 at 0 deg to 0.62 at 23 deg; the lowest value was 0.1 at 7 deg. Accordingly, the SSA algorithm was successful in detecting the seed with clinically relevant angles between seed and beam.
- 1 November 2007
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 122 (5_Suppleme) , 3008
Detection of brachytherapy seeds at varying angles with a singular-spectrum-analysis algorithm
A singular‐spectrum‐analysis (SSA) algorithm previously was shown to be successful in detecting brachytherapy seeds in B‐mode images when seeds were orthogonal to the ultrasound beam. In this study, the algorithm was extended to detect seeds at angles to the beam. The SSA algorithm derives P‐values from selected eigenvalue pairs of the autocorrelation matrix of seed echo signals. The P‐value indicates the probability of presence of a seed. A seed inserted in a gel pad and another inserted in beef tissue were scanned with a 5‐MHz transducer. The seed angle was varied from orthogonal to the beam to 23 deg from orthogonal, using 1‐degree increments. Simulations of seed echoes based on empirical data were generated and used to test the algorithm. Success in seed detection was expressed by a score computed from P‐values. Scores for simulations decreased from 0.8 to 0.45 as the angle increased from 0 to 12 deg. Scores for experimental data varied from 0.74 at 0 deg to 0.62 at 23 deg; the lowest value was 0.1 at 7 deg. Accordingly, the SSA algorithm was successful in detecting the seed with clinically relevant angles between seed and beam.
- 1 April 1999
- Published by Wolters Kluwer Health in Journal of Urology
- p. 323
ADVANCED 2-D AND 3-D ULTRASONIC IMAGING IN DIAGNOSIS OF PROSTATE CANCER
- 1 April 1999
- Published by Wolters Kluwer Health in Journal of Urology
- p. 323
ADVANCED 2-D AND 3-D ULTRASONIC IMAGING IN DIAGNOSIS OF PROSTATE CANCER