Junji Machi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Junji Machi has a total of 51 co-authors. Here are the top co-authors by number of shared publications:
- Jonathan Mamou
Riverside Res. Inst., New York, NY
6 shared publications - Emi Saegusa-Beecroft
Dept. of General Surgery, Univ. of Hawaii and Kuakini Medical Ctr., Honolulu, HI
5 shared publications - Ernest J. Feleppa
Riverside Research Institute (United States)
5 shared publications Eugene Yanagihara
Kuakini Medical Ctr., Dept. of Pathol., Honolulu, HI
5 shared publications- Masaki Hata
University of Hawaii and Kuakini Medical Center, Honolulu, USA
4 shared publications - Michael L. Oelze
Department of Electrical and Computer Engineering, University of Illinois Urbana-Champaign, Champaign, IL 61801, USA
3 shared publications
Latest Publications
- Open Access
- 16 March 2017
- Published by Springer Nature in BMC Medical Education
- Vol. 17 (1) , 57
Reliability and acceptability of six station multiple mini-interviews: past-behavioural versus situational questions in postgraduate medical admission
The multiple mini-interview (MMI) is increasingly used for postgraduate medical admissions and in undergraduate settings. MMIs use mostly Situational Questions (SQs) rather than Past-Behavioural Questions (PBQs). A previous study of MMIs in this setting, where PBQs and SQs were asked in the same order, reported that the reliability of PBQs was non-inferior to SQs and that SQs were more acceptable to candidates. The order in which the questions are asked may affect reliability and acceptability of an MMI. This study investigated the reliability of an MMI using both PBQs and SQs, minimising question order bias. Acceptability of PBQs and SQs was also assessed. Forty candidates applying for a postgraduate medical admission for 2016–2017 were included; 24 examiners were used. The MMI consisted of six stations with one examiner per station; a PBQ and a SQ were asked at every station, and the order of questions was alternated between stations. Reliability was analysed for scores obtained for PBQs or SQs separately, and for both questions. A post-MMI survey was used to assess the acceptability of PBQs and SQs. The generalisability (G) coefficients for PBQs only, SQs only, and both questions were 0.87, 0.96, and 0.80, respectively. Decision studies suggested that a four-station MMI would also be sufficiently reliable (G-coefficients 0.82 and 0.94 for PBQs and SQs, respectively). In total, 83% of participants were satisfied with the MMI. In terms of face validity, PBQs were more acceptable than SQs for candidates (p = 0.01), but equally acceptable for examiners (88% vs. 83% positive responses for PBQs vs. SQs; p = 0.377). Candidates preferred PBQs to SQs when asked to choose one, though this difference was not significant (p = 0.081); examiners showed a clear preference for PBQs (p = 0.007). Reliability and acceptability of six-station MMI were good among 40 postgraduate candidates; modelling suggested that four stations would also be reliable. SQs were more reliable than PBQs. Candidates found PBQs more acceptable than SQs and examiners preferred PBQs when they had to choose between the two. Our findings suggest that it is better to ask both PBQs and SQs during an MMI to maximise acceptability.
- 16 March 2017
- Published by Springer Nature in BMC Medical Education
- Vol. 17 (1) , 57
Open AccessReliability and acceptability of six station multiple mini-interviews: past-behavioural versus situational questions in postgraduate medical admission
The multiple mini-interview (MMI) is increasingly used for postgraduate medical admissions and in undergraduate settings. MMIs use mostly Situational Questions (SQs) rather than Past-Behavioural Questions (PBQs). A previous study of MMIs in this setting, where PBQs and SQs were asked in the same order, reported that the reliability of PBQs was non-inferior to SQs and that SQs were more acceptable to candidates. The order in which the questions are asked may affect reliability and acceptability of an MMI. This study investigated the reliability of an MMI using both PBQs and SQs, minimising question order bias. Acceptability of PBQs and SQs was also assessed. Forty candidates applying for a postgraduate medical admission for 2016–2017 were included; 24 examiners were used. The MMI consisted of six stations with one examiner per station; a PBQ and a SQ were asked at every station, and the order of questions was alternated between stations. Reliability was analysed for scores obtained for PBQs or SQs separately, and for both questions. A post-MMI survey was used to assess the acceptability of PBQs and SQs. The generalisability (G) coefficients for PBQs only, SQs only, and both questions were 0.87, 0.96, and 0.80, respectively. Decision studies suggested that a four-station MMI would also be sufficiently reliable (G-coefficients 0.82 and 0.94 for PBQs and SQs, respectively). In total, 83% of participants were satisfied with the MMI. In terms of face validity, PBQs were more acceptable than SQs for candidates (p = 0.01), but equally acceptable for examiners (88% vs. 83% positive responses for PBQs vs. SQs; p = 0.377). Candidates preferred PBQs to SQs when asked to choose one, though this difference was not significant (p = 0.081); examiners showed a clear preference for PBQs (p = 0.007). Reliability and acceptability of six-station MMI were good among 40 postgraduate candidates; modelling suggested that four stations would also be reliable. SQs were more reliable than PBQs. Candidates found PBQs more acceptable than SQs and examiners preferred PBQs when they had to choose between the two. Our findings suggest that it is better to ask both PBQs and SQs during an MMI to maximise acceptability.
- Open Access
- 14 April 2015
- Published by Springer Nature in BMC Medical Education
- Vol. 15 (1) , 1-9
Past-behavioural versus situational questions in a postgraduate admissions multiple mini-interview: a reliability and acceptability comparison
The Multiple Mini-Interview (MMI) mostly uses ‘Situational’ Questions (SQs) as an interview format within a station, rather than ‘Past-Behavioural’ Questions (PBQs), which are most frequently adopted in traditional single-station personal interviews (SSPIs) for non-medical and medical selection. This study investigated reliability and acceptability of the postgraduate admissions MMI with PBQ and SQ interview formats within MMI stations. Twenty-six Japanese medical graduates, first completed the two-year national obligatory initial postgraduate clinical training programme and then applied to three specialty training programmes - internal medicine, general surgery, and emergency medicine - in a Japanese teaching hospital, where they underwent the Accreditation Council for Graduate Medical Education (ACGME)-competency-based MMI. This MMI contained five stations, with two examiners per station. In each station, a PBQ, and then an SQ were asked consecutively. PBQ and SQ interview formats were not separated into two different stations, or the order of questioning of PBQs and SQs in individual stations was not changed due to lack of space and experienced examiners. Reliability was analysed for the scores of these two MMI question types. Candidates and examiners were surveyed on this experience. The PBQ and SQ formats had generalisability coefficients of 0.822 and 0.821, respectively. With one examiner per station, seven stations could produce a reliability of more than 0.80 in both PBQ and SQ formats. More than 60% of both candidates and examiners felt positive about the overall candidates’ ability. All participants liked the fairness of this MMI when compared with the previously experienced SSPI. SQs were perceived more favourable by candidates; in contrast, PBQs were perceived more relevant by examiners. Both PBQs and SQs are equally reliable and acceptable as station interview formats in the postgraduate admissions MMI. However, the use of the two formats within the same station, and with a fixed order, is not the best to maximise its utility as an admission test. Future studies are required to evaluate how best the SQs and PBQs should be combined as station interview formats to enhance reliability, feasibility, acceptability and predictive validity of the MMI.
- 14 April 2015
- Published by Springer Nature in BMC Medical Education
- Vol. 15 (1) , 1-9
Open AccessPast-behavioural versus situational questions in a postgraduate admissions multiple mini-interview: a reliability and acceptability comparison
The Multiple Mini-Interview (MMI) mostly uses ‘Situational’ Questions (SQs) as an interview format within a station, rather than ‘Past-Behavioural’ Questions (PBQs), which are most frequently adopted in traditional single-station personal interviews (SSPIs) for non-medical and medical selection. This study investigated reliability and acceptability of the postgraduate admissions MMI with PBQ and SQ interview formats within MMI stations. Twenty-six Japanese medical graduates, first completed the two-year national obligatory initial postgraduate clinical training programme and then applied to three specialty training programmes - internal medicine, general surgery, and emergency medicine - in a Japanese teaching hospital, where they underwent the Accreditation Council for Graduate Medical Education (ACGME)-competency-based MMI. This MMI contained five stations, with two examiners per station. In each station, a PBQ, and then an SQ were asked consecutively. PBQ and SQ interview formats were not separated into two different stations, or the order of questioning of PBQs and SQs in individual stations was not changed due to lack of space and experienced examiners. Reliability was analysed for the scores of these two MMI question types. Candidates and examiners were surveyed on this experience. The PBQ and SQ formats had generalisability coefficients of 0.822 and 0.821, respectively. With one examiner per station, seven stations could produce a reliability of more than 0.80 in both PBQ and SQ formats. More than 60% of both candidates and examiners felt positive about the overall candidates’ ability. All participants liked the fairness of this MMI when compared with the previously experienced SSPI. SQs were perceived more favourable by candidates; in contrast, PBQs were perceived more relevant by examiners. Both PBQs and SQs are equally reliable and acceptable as station interview formats in the postgraduate admissions MMI. However, the use of the two formats within the same station, and with a fixed order, is not the best to maximise its utility as an admission test. Future studies are required to evaluate how best the SQs and PBQs should be combined as station interview formats to enhance reliability, feasibility, acceptability and predictive validity of the MMI.
- 11 March 2015
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9323, 93231T
Quantitative photoacoustic assessment of ex-vivo lymph nodes of colorectal cancer patients
Staging of cancers and selection of appropriate treatment requires histological examination of multiple dissected lymph nodes (LNs) per patient, so that a staggering number of nodes require histopathological examination, and the finite resources of pathology facilities create a severe processing bottleneck. Histologically examining the entire 3D volume of every dissected node is not feasible, and therefore, only the central region of each node is examined histologically, which results in severe sampling limitations. In this work, we assess the feasibility of using quantitative photoacoustics (QPA) to overcome the limitations imposed by current procedures and eliminate the resulting under sampling in node assessments. QPA is emerging as a new hybrid modality that assesses tissue properties and classifies tissue type based on multiple estimates derived from spectrum analysis of photoacoustic (PA) radiofrequency (RF) data and from statistical analysis of envelope-signal data derived from the RF signals. Our study seeks to use QPA to distinguish cancerous from non-cancerous regions of dissected LNs and hence serve as a reliable means of imaging and detecting small but clinically significant cancerous foci that would be missed by current methods. Dissected lymph nodes were placed in a water bath and PA signals were generated using a wavelength-tunable (680-950 nm) laser. A 26-MHz, f-2 transducer was used to sense the PA signals. We present an overview of our experimental setup; provide a statistical analysis of multi-wavelength classification parameters (mid-band fit, slope, intercept) obtained from the PA signal spectrum generated in the LNs; and compare QPA performance with our established quantitative ultrasound (QUS) techniques in distinguishing metastatic from non-cancerous tissue in dissected LNs. QPA-QUS methods offer a novel general means of tissue typing and evaluation in a broad range of disease-assessment applications, e.g., cardiac, intravascular, musculoskeletal, endocrine-gland, etc.
- 11 March 2015
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9323, 93231T
Quantitative photoacoustic assessment of ex-vivo lymph nodes of colorectal cancer patients
Staging of cancers and selection of appropriate treatment requires histological examination of multiple dissected lymph nodes (LNs) per patient, so that a staggering number of nodes require histopathological examination, and the finite resources of pathology facilities create a severe processing bottleneck. Histologically examining the entire 3D volume of every dissected node is not feasible, and therefore, only the central region of each node is examined histologically, which results in severe sampling limitations. In this work, we assess the feasibility of using quantitative photoacoustics (QPA) to overcome the limitations imposed by current procedures and eliminate the resulting under sampling in node assessments. QPA is emerging as a new hybrid modality that assesses tissue properties and classifies tissue type based on multiple estimates derived from spectrum analysis of photoacoustic (PA) radiofrequency (RF) data and from statistical analysis of envelope-signal data derived from the RF signals. Our study seeks to use QPA to distinguish cancerous from non-cancerous regions of dissected LNs and hence serve as a reliable means of imaging and detecting small but clinically significant cancerous foci that would be missed by current methods. Dissected lymph nodes were placed in a water bath and PA signals were generated using a wavelength-tunable (680-950 nm) laser. A 26-MHz, f-2 transducer was used to sense the PA signals. We present an overview of our experimental setup; provide a statistical analysis of multi-wavelength classification parameters (mid-band fit, slope, intercept) obtained from the PA signal spectrum generated in the LNs; and compare QPA performance with our established quantitative ultrasound (QUS) techniques in distinguishing metastatic from non-cancerous tissue in dissected LNs. QPA-QUS methods offer a novel general means of tissue typing and evaluation in a broad range of disease-assessment applications, e.g., cardiac, intravascular, musculoskeletal, endocrine-gland, etc.
- 1 October 2014
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 136 (4_Suppleme) , 2157
250-MHz quantitative acoustic microscopy for assessing human lymph-node microstructure
- 1 October 2014
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 136 (4_Suppleme) , 2157
250-MHz quantitative acoustic microscopy for assessing human lymph-node microstructure
- 1 October 2014
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 136 (4_Suppleme) , 2123
Quantitative-ultrasound detection of cancer in human lymph nodes based on support vector machines
- 1 October 2014
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 136 (4_Suppleme) , 2123
Quantitative-ultrasound detection of cancer in human lymph nodes based on support vector machines
- 3 April 2014
- Published by Springer Nature
- p. 287-303
Future Perspective in Abdominal Ultrasound
- 3 April 2014
- Published by Springer Nature
- p. 283-285
Coding and Billing for Ultrasound Examinations
- 3 April 2014
- Published by Springer Nature
- p. 269-277
Getting Started
- 5 September 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 37-40
Three-dimensional quantitative high-frequency characterization of freshly-excised human lymph nodes
High-frequency quantitative ultrasound (QUS) permits characterization of tissue microstructure using system-independent estimates. In this study, freshly-excised lymph nodes from cancer patients were evaluated using specifically designed three-dimensional (3D) QUS methods. The long-term objective was to develop 3D QUS methods for detecting metastases. Detection of metastases is critically important for cancer staging and treatment planning. A custom laboratory scanning system was used to acquire radio-frequency (RF) data in 3D from excised lymph nodes using a 26-MHz center-frequency transducer. Overlapping 1-mm cylindrical regions-of-interest (ROIs) of the RF data were processed to yield 13 QUS estimates associated with tissue microstructure. QUS estimates were obtained from more than 250 nodes from more than 150 colorectal-, gastric-, and breast-cancer patients. Cancer-detection performance was assessed for individual estimates and linear combinations of estimates. ROC results demonstrated excellent classification. For colorectal- and gastric-cancer nodes, the areas under the ROC curves (AUCs) were above 0.94. Slightly poorer results (AUC 0.87) were obtained for breast nodes. Images based on QUS parameters also permitted localization of cancer foci in some micrometastatic cases. Therefore, these advanced 3D QUS methods potentially can be valuable for detecting small metastatic foci in dissected lymph nodes.
- 5 September 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 37-40
Three-dimensional quantitative high-frequency characterization of freshly-excised human lymph nodes
High-frequency quantitative ultrasound (QUS) permits characterization of tissue microstructure using system-independent estimates. In this study, freshly-excised lymph nodes from cancer patients were evaluated using specifically designed three-dimensional (3D) QUS methods. The long-term objective was to develop 3D QUS methods for detecting metastases. Detection of metastases is critically important for cancer staging and treatment planning. A custom laboratory scanning system was used to acquire radio-frequency (RF) data in 3D from excised lymph nodes using a 26-MHz center-frequency transducer. Overlapping 1-mm cylindrical regions-of-interest (ROIs) of the RF data were processed to yield 13 QUS estimates associated with tissue microstructure. QUS estimates were obtained from more than 250 nodes from more than 150 colorectal-, gastric-, and breast-cancer patients. Cancer-detection performance was assessed for individual estimates and linear combinations of estimates. ROC results demonstrated excellent classification. For colorectal- and gastric-cancer nodes, the areas under the ROC curves (AUCs) were above 0.94. Slightly poorer results (AUC 0.87) were obtained for breast nodes. Images based on QUS parameters also permitted localization of cancer foci in some micrometastatic cases. Therefore, these advanced 3D QUS methods potentially can be valuable for detecting small metastatic foci in dissected lymph nodes.
- Open Access
- 15 April 2011
- Published by Springer Nature in Pathology and Oncology Research
- Vol. 17 (4) , 835-41
Entire-volume serial histological examination for detection of micrometastases in lymph nodes of colorectal cancers.
- 15 April 2011
- Published by Springer Nature in Pathology and Oncology Research
- Vol. 17 (4) , 835-41
Open AccessEntire-volume serial histological examination for detection of micrometastases in lymph nodes of colorectal cancers.