Kwan Hyoung Kang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Kwan Hyoung Kang has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
Sung Hee Ko
Department of Mechanical Engineering, Pohang University of Science and Technology, San 31, Hyojadong, Pohang, Gyeongbuk 790-784, Korea
5 shared publications- Jun Kwon Park
Department of Mechanical Engineering, Pohang University of Science and Technology, San 31, Hyoja-dong, Pohang 790-784, South Korea
4 shared publications Horim Lee
Department of Mechanical Engineering, Pohang University of Science and Technology (POSTECH), San 31, Hyoja-dong, Nam-Gu, Pohang, Gyeongbuk, 790-784, the Republic of Korea
3 shared publicationsBonchull C. Koo
Department of Mechanical Engineering, Pohang University of Science and Technology (POSTECH), San 31, Hyoja-dong, Pohang 790-784, South Korea
2 shared publications- Jongyoon Han
Department of Biological Engineering, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA
2 shared publications Sanghyun Lee
Department of Mechanical Engineering, Pohang University of Science and Technology (POSTECH), San 31, Hyoja-dong, Pohang 790-784, South Korea
2 shared publications
Latest Publications
- Open Access
- 19 December 2013
- Published by Springer Nature in Scientific Reports
- Vol. 3 (1) , 3483
Ion concentration polarization-based continuous separation device using electrical repulsion in the depletion region
We proposed a novel separation method, which is the first report using ion concentration polarization (ICP) to separate particles continuously. We analyzed the electrical forces that cause the repulsion of particles in the depletion region formed by ICP. Using the electrical repulsion, micro- and nano-sized particles were separated based on their electrophoretic mobilities. Because the separation of particles was performed using a strong electric field in the depletion region without the use of internal electrodes, it offers the advantages of simple, low-cost device fabrication and bubble-free operation compared with conventional continuous electrophoretic separation methods, such as miniaturizing free-flow electrophoresis (μ-FFE). This separation device is expected to be a useful tool for separating various biochemical samples, including cells, proteins, DNAs and even ions.
- 19 December 2013
- Published by Springer Nature in Scientific Reports
- Vol. 3 (1) , 3483
Open AccessIon concentration polarization-based continuous separation device using electrical repulsion in the depletion region
We proposed a novel separation method, which is the first report using ion concentration polarization (ICP) to separate particles continuously. We analyzed the electrical forces that cause the repulsion of particles in the depletion region formed by ICP. Using the electrical repulsion, micro- and nano-sized particles were separated based on their electrophoretic mobilities. Because the separation of particles was performed using a strong electric field in the depletion region without the use of internal electrodes, it offers the advantages of simple, low-cost device fabrication and bubble-free operation compared with conventional continuous electrophoretic separation methods, such as miniaturizing free-flow electrophoresis (μ-FFE). This separation device is expected to be a useful tool for separating various biochemical samples, including cells, proteins, DNAs and even ions.
- Open Access
- 20 June 2013
- Published by Springer Nature in Scientific Reports
- Vol. 3 (1) , srep02037
Spontaneous electrical charging of droplets by conventional pipetting
We report that a droplet dispensed from a micropipette almost always has a considerable electrical charge of a magnitude dependent on the constituents of the droplet, on atmospheric humidity and on the coating material of pipette tip. We show that this natural electrification of a droplet originates from the charge separation between a droplet and pipette tip surface by contact with water due to the ionization of surface chemical groups. Charge on a droplet can make it difficult to detach the droplet from the pipette tip, can decrease its surface tension, can affect the chemical characteristics of solutions due to interactions with charged molecules, and can influence the combination and localization of charged bio-molecules; in all cases, the charge may affect results of experiments in which any of these factors is important. Thus, these findings reveal experimental parameters that should be controlled in experiments that use micropipettes.
- 20 June 2013
- Published by Springer Nature in Scientific Reports
- Vol. 3 (1) , srep02037
Open AccessSpontaneous electrical charging of droplets by conventional pipetting
We report that a droplet dispensed from a micropipette almost always has a considerable electrical charge of a magnitude dependent on the constituents of the droplet, on atmospheric humidity and on the coating material of pipette tip. We show that this natural electrification of a droplet originates from the charge separation between a droplet and pipette tip surface by contact with water due to the ionization of surface chemical groups. Charge on a droplet can make it difficult to detach the droplet from the pipette tip, can decrease its surface tension, can affect the chemical characteristics of solutions due to interactions with charged molecules, and can influence the combination and localization of charged bio-molecules; in all cases, the charge may affect results of experiments in which any of these factors is important. Thus, these findings reveal experimental parameters that should be controlled in experiments that use micropipettes.
- 3 October 2012
- Published by Royal Society of Chemistry (RSC) in Soft Matter
- Vol. 8 (47) , 11889-11896
How the change of contact angle occurs for an evaporating droplet: effect of impurity and attached water films
On a hydrophobic surface, the contact angle of an evaporating droplet decreases with time and becomes much smaller than its receding contact angle; the rate of decrease is accelerated with time. When we use impurity-concentrated water produced by partial distillation, the decrease in contact angle is remarkably accelerated with time. In contrast, for purified water, the decrease in contact angle is significantly reduced and the start of stage 3 is delayed. These results indicate that the submicron-sized impurities cause the decrease in contact angle. Also, we found that a number of attached thin films of water are generated around the periphery of impure droplets. We derived the contact angle equation under the Cassie–Baxter model by regarding the water film as a heterogeneous layer. We compared the theoretical model to the experimental data, and these results suggest that the attached film should be considered as one of the direct causes for the large deviation from the Young's angle of evaporating droplets.
- 3 October 2012
- Published by Royal Society of Chemistry (RSC) in Soft Matter
- Vol. 8 (47) , 11889-11896
How the change of contact angle occurs for an evaporating droplet: effect of impurity and attached water films
On a hydrophobic surface, the contact angle of an evaporating droplet decreases with time and becomes much smaller than its receding contact angle; the rate of decrease is accelerated with time. When we use impurity-concentrated water produced by partial distillation, the decrease in contact angle is remarkably accelerated with time. In contrast, for purified water, the decrease in contact angle is significantly reduced and the start of stage 3 is delayed. These results indicate that the submicron-sized impurities cause the decrease in contact angle. Also, we found that a number of attached thin films of water are generated around the periphery of impure droplets. We derived the contact angle equation under the Cassie–Baxter model by regarding the water film as a heterogeneous layer. We compared the theoretical model to the experimental data, and these results suggest that the attached film should be considered as one of the direct causes for the large deviation from the Young's angle of evaporating droplets.
- 24 July 2012
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 12 (21) , 4472-4482
Nanofluidic preconcentration device in a straight microchannel using ion concentration polarization
In this paper, we introduce a simple, straight microchannel design for a nanofluidic protein concentration device. Compared with concentration devices previously developed, the anode channel and cathode channel in this new concentration scheme are both integrated into a straight microchannel, with one inlet and one outlet. Most of the functions of a conventional two-channel concentration device can be achieved by this concentration device, and the efficiency of sample accumulation can be controlled by the dimension of the Nafion membrane. Also, the operating mechanism of this device was tested on various material combinations such as PDMS (polydimethyl-siloxane) channel-glass substrate and silicon channel-PDMS substrate. Using a combined PDMS-silicon device which was sealed reversibly without plasma bonding, surface based immunoassay for concentrator-enhanced detection of clinically relevant samples such as C-reactive protein (CRP) was demonstrated. As a result, it was possible to enhance the detection sensitivity of the immunoassay by more than 500 folds compared to the immunoassay without preconcentration process.
- 24 July 2012
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 12 (21) , 4472-4482
Nanofluidic preconcentration device in a straight microchannel using ion concentration polarization
In this paper, we introduce a simple, straight microchannel design for a nanofluidic protein concentration device. Compared with concentration devices previously developed, the anode channel and cathode channel in this new concentration scheme are both integrated into a straight microchannel, with one inlet and one outlet. Most of the functions of a conventional two-channel concentration device can be achieved by this concentration device, and the efficiency of sample accumulation can be controlled by the dimension of the Nafion membrane. Also, the operating mechanism of this device was tested on various material combinations such as PDMS (polydimethyl-siloxane) channel-glass substrate and silicon channel-PDMS substrate. Using a combined PDMS-silicon device which was sealed reversibly without plasma bonding, surface based immunoassay for concentrator-enhanced detection of clinically relevant samples such as C-reactive protein (CRP) was demonstrated. As a result, it was possible to enhance the detection sensitivity of the immunoassay by more than 500 folds compared to the immunoassay without preconcentration process.
- 2 April 2012
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 28 (15) , 6307-6312
Size-Selective Sliding of Sessile Drops on a Slightly Inclined Plane Using Low-Frequency AC Electrowetting
When placed on an inclined solid plane, drops often stick to the solid surface due to pinning forces caused by contact angle hysteresis. When the drop size or the plane’s incline angle is small, the drop is difficult to slide due to a decrease in gravitational force. Here we demonstrate that small drops (0.4–9 μL) on a slightly inclined plane (∼12°, Teflon and parylene-C surface) can be mobilized through patterned electrodes by applying low-frequency ac electrowetting under 400 Hz (110–180 Vrms), which has a mechanism different from that of the high-frequency ac method that induces sliding by reducing contact angle hysteresis. We attribute the sliding motion of our method to a combination of contact angle hysteresis and interfacial oscillation driven by ac electrowetting instead of the minimization of contact angle hysteresis at a high frequency. We investigated the effects of ac frequency on the sliding motion and terminal sliding of drops; the terminal sliding velocity is greatest at resonance frequency. Varying the electrowetting number (0.21–0.56) at a fixed frequency (40 Hz) for 5 μL drops, we found an empirical relationship between the electrowetting number and the terminal sliding velocity. Using the relationship between the drop size and ac frequency, we can selectively slide drops of a specific size or merge two drops along an inclined plane. This simple method will help with constructing microfluidic platforms with sorting, merging, transporting, and mixing of drops without a programmable control of electrical signals. Also, this method has a potential in heat transfer applications because heat removal capacity can be enhanced significantly through drop oscillation.
- 2 April 2012
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 28 (15) , 6307-6312
Size-Selective Sliding of Sessile Drops on a Slightly Inclined Plane Using Low-Frequency AC Electrowetting
When placed on an inclined solid plane, drops often stick to the solid surface due to pinning forces caused by contact angle hysteresis. When the drop size or the plane’s incline angle is small, the drop is difficult to slide due to a decrease in gravitational force. Here we demonstrate that small drops (0.4–9 μL) on a slightly inclined plane (∼12°, Teflon and parylene-C surface) can be mobilized through patterned electrodes by applying low-frequency ac electrowetting under 400 Hz (110–180 Vrms), which has a mechanism different from that of the high-frequency ac method that induces sliding by reducing contact angle hysteresis. We attribute the sliding motion of our method to a combination of contact angle hysteresis and interfacial oscillation driven by ac electrowetting instead of the minimization of contact angle hysteresis at a high frequency. We investigated the effects of ac frequency on the sliding motion and terminal sliding of drops; the terminal sliding velocity is greatest at resonance frequency. Varying the electrowetting number (0.21–0.56) at a fixed frequency (40 Hz) for 5 μL drops, we found an empirical relationship between the electrowetting number and the terminal sliding velocity. Using the relationship between the drop size and ac frequency, we can selectively slide drops of a specific size or merge two drops along an inclined plane. This simple method will help with constructing microfluidic platforms with sorting, merging, transporting, and mixing of drops without a programmable control of electrical signals. Also, this method has a potential in heat transfer applications because heat removal capacity can be enhanced significantly through drop oscillation.
- 1 April 2012
- Published by AIP Publishing in Physics of Fluids
- Vol. 24 (4)
Numerical analysis of moving contact line with contact angle hysteresis using feedback deceleration technique
Contact angle (CA) hysteresis is important in many natural and engineering wetting processes, but predicting it numerically is difficult. We developed an algorithm that considers CA hysteresis when analyzing the motion of the contact line (CL). This algorithm employs feedback control of CA which decelerates CL speed to make the CL stationary in the hysteretic range of CA, and one control coefficient should be heuristically determined depending on characteristic time of the simulated system. The algorithm requires embedding only a simple additional routine with little modification of a code which considers the dynamic CA. The method is non-iterative and explicit, and also has less computational load than other algorithms. For a drop hanging on a wire, the proposed algorithm accurately predicts the theoretical equilibrium CA. For the drop impacting on a dry surface, the results of the proposed algorithm agree well with experimental results including the intermittent occurrence of the pinning of CL. The proposed algorithm is as accurate as other algorithms, but faster.
- 1 April 2012
- Published by AIP Publishing in Physics of Fluids
- Vol. 24 (4)
Numerical analysis of moving contact line with contact angle hysteresis using feedback deceleration technique
Contact angle (CA) hysteresis is important in many natural and engineering wetting processes, but predicting it numerically is difficult. We developed an algorithm that considers CA hysteresis when analyzing the motion of the contact line (CL). This algorithm employs feedback control of CA which decelerates CL speed to make the CL stationary in the hysteretic range of CA, and one control coefficient should be heuristically determined depending on characteristic time of the simulated system. The algorithm requires embedding only a simple additional routine with little modification of a code which considers the dynamic CA. The method is non-iterative and explicit, and also has less computational load than other algorithms. For a drop hanging on a wire, the proposed algorithm accurately predicts the theoretical equilibrium CA. For the drop impacting on a dry surface, the results of the proposed algorithm agree well with experimental results including the intermittent occurrence of the pinning of CL. The proposed algorithm is as accurate as other algorithms, but faster.
- Open Access
- 14 February 2011
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 11 (7) , 1351-1358
Massively parallel concentration device for multiplexed immunoassays
A massively parallel nanofluidic concentration device array for multiplexed and high-throughput biomolecule detection is demonstrated. By optimizing the microchannel/nanojunction design and channel conductivity, an array of up to 128 nanofluidic concentration devices were fabricated. Operation of the entire array requires only one inlet and one outlet reservoir, with the application of a single operational voltage bias across them. Concentration efficiencies of the devices were found to be uniform within the array, within 5% error. Alternatively, concentration speed in each channel can be individually tuned by controlling the length of the inlet microchannel and thus controlling the flow rate based on change of the tangential electric field. This allows immuno-binding reactions at different concentration ranges to be performed in parallel. Using multiplexed, successive-concentration enhanced detection in the device, we have shown that the dynamic range and reliability of the immunoassay can be significantly increased.
- 14 February 2011
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 11 (7) , 1351-1358
Open AccessMassively parallel concentration device for multiplexed immunoassays
A massively parallel nanofluidic concentration device array for multiplexed and high-throughput biomolecule detection is demonstrated. By optimizing the microchannel/nanojunction design and channel conductivity, an array of up to 128 nanofluidic concentration devices were fabricated. Operation of the entire array requires only one inlet and one outlet reservoir, with the application of a single operational voltage bias across them. Concentration efficiencies of the devices were found to be uniform within the array, within 5% error. Alternatively, concentration speed in each channel can be individually tuned by controlling the length of the inlet microchannel and thus controlling the flow rate based on change of the tangential electric field. This allows immuno-binding reactions at different concentration ranges to be performed in parallel. Using multiplexed, successive-concentration enhanced detection in the device, we have shown that the dynamic range and reliability of the immunoassay can be significantly increased.
- 31 December 2010
- Published by The Korean Society of Visualization in Journal of the Korean Society of Visualization
- Vol. 8 (4) , 38-42
Visualization of Ion Transport and pH Change in Ion Concentration Polarization
- 31 December 2010
- Published by The Korean Society of Visualization in Journal of the Korean Society of Visualization
- Vol. 8 (4) , 38-42
Visualization of Ion Transport and pH Change in Ion Concentration Polarization
- Open Access
- 14 July 2010
- Published by AIP Publishing in Biomicrofluidics
- Vol. 4 (3) , 034102
Optoelectrofluidic field separation based on light-intensity gradients
Optoelectrofluidic field separation (OEFS) of particles under light -intensity gradient (LIG) is reported, where the LIG illumination on the photoconductive layer converts the short-ranged dielectrophoresis (DEP) force to the long-ranged one. The long-ranged DEP force can compete with the hydrodynamic force by alternating current electro-osmosis (ACEO) over the entire illumination area for realizing effective field separation of particles. In the OEFS system, the codirectional illumination and observation induce the levitation effect, compensating the attenuation of the DEP force under LIG illumination by slightly floating particles from the surface. Results of the field separation and concentration of diverse particle pairs are well demonstrated, and conditions determining the critical radius and effective particle manipulation are discussed. The OEFS with codirectional LIG strategy could be a promising particle manipulation method in many applications where a rapid manipulation of biological cells and particles over the entire working area are of interest.- 14 July 2010
- Published by AIP Publishing in Biomicrofluidics
- Vol. 4 (3) , 034102
Open AccessOptoelectrofluidic field separation based on light-intensity gradients
Optoelectrofluidic field separation (OEFS) of particles under light -intensity gradient (LIG) is reported, where the LIG illumination on the photoconductive layer converts the short-ranged dielectrophoresis (DEP) force to the long-ranged one. The long-ranged DEP force can compete with the hydrodynamic force by alternating current electro-osmosis (ACEO) over the entire illumination area for realizing effective field separation of particles. In the OEFS system, the codirectional illumination and observation induce the levitation effect, compensating the attenuation of the DEP force under LIG illumination by slightly floating particles from the surface. Results of the field separation and concentration of diverse particle pairs are well demonstrated, and conditions determining the critical radius and effective particle manipulation are discussed. The OEFS with codirectional LIG strategy could be a promising particle manipulation method in many applications where a rapid manipulation of biological cells and particles over the entire working area are of interest. - Open Access
- 21 April 2010
- Published by AIP Publishing in Biomicrofluidics
- Vol. 4 (2) , 024102
Fast and reliable droplet transport on single-plate electrowetting on dielectrics using nonfloating switching method
In a droplet transport based on electrowetting on dielectrics, the parallel-plate configuration is more popular than the single-plate one because the droplet transport becomes increasingly difficult without cover plate. In spite of the improved transport performance, the parallel-plate configuration often limits the access to the peripheral components, requesting the removal of the cover plate, the single-plate configuration. We investigated the fundamental features of droplet transport for the single-plate configuration. We compared the performance of several switching methods with respect to maximum speed of successive transport without failure and suggested nonfloating switching method which is inherently free from the charge-residue problem and exerts greater force on a droplet than conventional switching methods. A simple theory is provided to understand the different results for the switching methods.
- 21 April 2010
- Published by AIP Publishing in Biomicrofluidics
- Vol. 4 (2) , 024102
Open AccessFast and reliable droplet transport on single-plate electrowetting on dielectrics using nonfloating switching method
In a droplet transport based on electrowetting on dielectrics, the parallel-plate configuration is more popular than the single-plate one because the droplet transport becomes increasingly difficult without cover plate. In spite of the improved transport performance, the parallel-plate configuration often limits the access to the peripheral components, requesting the removal of the cover plate, the single-plate configuration. We investigated the fundamental features of droplet transport for the single-plate configuration. We compared the performance of several switching methods with respect to maximum speed of successive transport without failure and suggested nonfloating switching method which is inherently free from the charge-residue problem and exerts greater force on a droplet than conventional switching methods. A simple theory is provided to understand the different results for the switching methods.