Hyun Keol Kim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hyun Keol Kim has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Andreas H. Hielscher
Department of Biomedical Engineering, Columbia University, New York, NY 10027, USA
3 shared publications A. H. Hielscher
Columbia University 1 Department of Biomedical Engineering New York, New York 10027, USA
1 shared publicationC. J. Fong
Columbia University 1 Department of Biomedical Engineering New York, New York 10027, USA
1 shared publication- Gautam Shrikhande
Department of Surgery, NY Presbyterian Hospital-Columbia University, NY, USA
1 shared publication - I. Kim
Department of Surgery, NY Presbyterian Hospital-Columbia University, NY, USA
1 shared publication - J.W. Hoi
Department of Biomedical Engineering, Columbia University, NY, USA
1 shared publication
Latest Publications
- 1 January 2015
- Published by Elsevier in European Journal of Vascular and Endovascular Surgery
- Vol. 49 (1) , 83-89
Detection of Peripheral Arterial Disease Within the Foot Using Vascular Optical Tomographic Imaging: A Clinical Pilot Study
- 1 January 2015
- Published by Elsevier in European Journal of Vascular and Endovascular Surgery
- Vol. 49 (1) , 83-89
Detection of Peripheral Arterial Disease Within the Foot Using Vascular Optical Tomographic Imaging: A Clinical Pilot Study
- 1 March 2012
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 83 (3) , 033108
A wireless handheld probe with spectrally constrained evolution strategies for diffuse optical imaging of tissue
We present a low-cost, portable, wireless diffuse optical imaging device. The handheld device is fast, portable, and can be applied to a wide range of both static and dynamic imaging applications including breast cancer, functional brain imaging, and peripheral artery disease. The continuous-wave probe has four near-infrared wavelengths and uses digital detection techniques to perform measurements at 2.3 Hz. Using a multispectral evolution algorithm for chromophore reconstruction, we can measure absolute oxygenated and deoxygenated hemoglobin concentration as well as scattering in tissue. Performance of the device is demonstrated using a series of liquid phantoms comprised of Intralipid®, ink, and dye.
- 1 March 2012
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 83 (3) , 033108
A wireless handheld probe with spectrally constrained evolution strategies for diffuse optical imaging of tissue
We present a low-cost, portable, wireless diffuse optical imaging device. The handheld device is fast, portable, and can be applied to a wide range of both static and dynamic imaging applications including breast cancer, functional brain imaging, and peripheral artery disease. The continuous-wave probe has four near-infrared wavelengths and uses digital detection techniques to perform measurements at 2.3 Hz. Using a multispectral evolution algorithm for chromophore reconstruction, we can measure absolute oxygenated and deoxygenated hemoglobin concentration as well as scattering in tissue. Performance of the device is demonstrated using a series of liquid phantoms comprised of Intralipid®, ink, and dye.
- 22 March 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Selected Topics in Quantum Electronics
- Vol. 16 (4) , 793-803
PDE-Constrained Fluorescence Tomography With the Frequency-Domain Equation of Radiative Transfer
We present the first fluorescence tomography algorithm that is based on a partial differential equation (PDE) constrained approach. PDE methods have been increasingly employed in many numerical applications, as they often lead to faster and more robust solutions of many inverse problems. In particular, we use a sequential quadratic programming (SQP) method, which allows solving the two forward problems in fluorescence tomography (one for the excitation and one for the emission radiances) and one inverse problem (for recovering the spatial distribution of the fluorescent sources) simultaneously by updating both forward and inverse variables in simultaneously at each of iteration of the optimization process. We evaluate the performance of this approach with numerical and experimental data using a transport-theory frequency-domain algorithm as forward model for light propagation in tissue. The results show that the PDE-constrained approach is computationally stable and accelerates the image reconstruction process up to a factor of 15 when compared to commonly employed unconstrained methods.
- 22 March 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Selected Topics in Quantum Electronics
- Vol. 16 (4) , 793-803
PDE-Constrained Fluorescence Tomography With the Frequency-Domain Equation of Radiative Transfer
We present the first fluorescence tomography algorithm that is based on a partial differential equation (PDE) constrained approach. PDE methods have been increasingly employed in many numerical applications, as they often lead to faster and more robust solutions of many inverse problems. In particular, we use a sequential quadratic programming (SQP) method, which allows solving the two forward problems in fluorescence tomography (one for the excitation and one for the emission radiances) and one inverse problem (for recovering the spatial distribution of the fluorescent sources) simultaneously by updating both forward and inverse variables in simultaneously at each of iteration of the optimization process. We evaluate the performance of this approach with numerical and experimental data using a transport-theory frequency-domain algorithm as forward model for light propagation in tissue. The results show that the PDE-constrained approach is computationally stable and accelerates the image reconstruction process up to a factor of 15 when compared to commonly employed unconstrained methods.