Andreas H. Hielscher
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Andreas H. Hielscher has a total of 85 co-authors. Here are the top co-authors by number of shared publications:
Hyun K. Kim
From the Departments of Biomedical Engineering (J.E.G., M.F., M.A., A.H.H.) and Electrical Engineering (A.H.H.), Columbia University, 500 W 120th St, Mudd Bldg, ET351, MC 8904, New York, NY 10027; Department of Medicine, Division of Hematology/Oncology (E.A.L., J.A.C., K.D.C., K.K., D.L.H.), Department of Radiology (H.K.K., A.H.H.), Department of Pathology and Cell Biology (H.H.), and Department of Epidemiology (K.D.C., D.L.H.), Columbia University Medical Center, New York, NY
4 shared publicationsHyun Keol Kim
Columbia University, New York, Department of Biomedical Engineering, New York, New York 10027
4 shared publications- Kui Ren
Department of Applied Physics and Applied Mathematics, Columbia University, New York, NY 10027 USA
4 shared publications Uwe J. Netz
Laser- und Medizin-Technologie GmbH Berlin, Berlin, Dahlem 14195, Germany
4 shared publications- Hyun Keol Kim
Department of Radiology, Columbia University, 660 W 168th St, New York, NY 10032, USA
3 shared publications Jingfei Jia
Department of Electrical Engineering, Columbia University, New York, NY 10027, USA
3 shared publications
Latest Publications
- 19 October 2018
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 9 (11) , 5597-5614
Non-contact dynamic diffuse optical tomography imaging system for evaluating lower extremity vasculature
A novel multi-view non-contact dynamic diffuse optical tomographic imaging system for the clinical evaluation of vasculature in the lower extremities is presented. The system design and implementation are described in detail, including methods for simultaneously obtaining and reconstructing diffusely reflected and transmitted light using a system of mirrors and a single CCD camera. The system and its performance using numeric simulations and optical phantoms. Measurements of a healthy foot in vivo demonstrates the potential of the system in assessing perfusion within the foot.
- 19 October 2018
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 9 (11) , 5597-5614
Non-contact dynamic diffuse optical tomography imaging system for evaluating lower extremity vasculature
A novel multi-view non-contact dynamic diffuse optical tomographic imaging system for the clinical evaluation of vasculature in the lower extremities is presented. The system design and implementation are described in detail, including methods for simultaneously obtaining and reconstructing diffusely reflected and transmitted light using a system of mirrors and a single CCD camera. The system and its performance using numeric simulations and optical phantoms. Measurements of a healthy foot in vivo demonstrates the potential of the system in assessing perfusion within the foot.
- 1 June 2018
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 287 (3) , 778-786
Dynamic Diffuse Optical Tomography for Monitoring Neoadjuvant Chemotherapy in Patients with Breast Cancer
Dynamic diffuse optical tomographic imaging of intrinsic hemodynamic features in tumor-bearing breasts can be used to identify parameters that associate with the degree of pathologic response during 5-month neoadjuvant chemotherapy, as early as 2 weeks after treatment initiation. Purpose To identify dynamic optical imaging features that associate with the degree of pathologic response in patients with breast cancer during neoadjuvant chemotherapy (NAC). Materials and Methods Of 40 patients with breast cancer who participated in a longitudinal study between June 2011 and March 2016, 34 completed the study. There were 13 patients who obtained a pathologic complete response (pCR) and 21 patients who did not obtain a pCR. Imaging data from six subjects were excluded from the study because either the patients dropped out of the study before it was finished or there was an instrumentation malfunction. Two weeks into the treatment regimen, three-dimensional images of both breasts during a breath hold were acquired by using dynamic diffuse optical tomography. Features from the breath-hold traces were used to distinguish between response groups. Receiver operating characteristic (ROC) curves and sensitivity analysis were used to determine the degree of association with 5-month treatment ou...
- 1 June 2018
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 287 (3) , 778-786
Dynamic Diffuse Optical Tomography for Monitoring Neoadjuvant Chemotherapy in Patients with Breast Cancer
Dynamic diffuse optical tomographic imaging of intrinsic hemodynamic features in tumor-bearing breasts can be used to identify parameters that associate with the degree of pathologic response during 5-month neoadjuvant chemotherapy, as early as 2 weeks after treatment initiation. Purpose To identify dynamic optical imaging features that associate with the degree of pathologic response in patients with breast cancer during neoadjuvant chemotherapy (NAC). Materials and Methods Of 40 patients with breast cancer who participated in a longitudinal study between June 2011 and March 2016, 34 completed the study. There were 13 patients who obtained a pathologic complete response (pCR) and 21 patients who did not obtain a pCR. Imaging data from six subjects were excluded from the study because either the patients dropped out of the study before it was finished or there was an instrumentation malfunction. Two weeks into the treatment regimen, three-dimensional images of both breasts during a breath hold were acquired by using dynamic diffuse optical tomography. Features from the breath-hold traces were used to distinguish between response groups. Receiver operating characteristic (ROC) curves and sensitivity analysis were used to determine the degree of association with 5-month treatment ou...
- Open Access
- 1 January 2016
- Published by Optica Publishing Group
- p. OTh2C.1
Translation of Optical Tomographic Imaging Methods into Clinical Practice
Clinical studies that evaluate the use of optical tomographic imaging to manage arthritis, peripheral artery disease and neoadjuvent therapy in cancer patients are showing great promise for commercially viable translation into clinical practice.
- 1 January 2016
- Published by Optica Publishing Group
- p. OTh2C.1
Open AccessTranslation of Optical Tomographic Imaging Methods into Clinical Practice
Clinical studies that evaluate the use of optical tomographic imaging to manage arthritis, peripheral artery disease and neoadjuvent therapy in cancer patients are showing great promise for commercially viable translation into clinical practice.
- 1 August 2015
- Published by Elsevier in Journal of Quantitative Spectroscopy and Radiative Transfer
- Vol. 167, 10-22
Fast linear solver for radiative transport equation with multiple right hand sides in diffuse optical tomography
- 1 August 2015
- Published by Elsevier in Journal of Quantitative Spectroscopy and Radiative Transfer
- Vol. 167, 10-22
Fast linear solver for radiative transport equation with multiple right hand sides in diffuse optical tomography
- 1 January 2015
- Published by Elsevier in European Journal of Vascular and Endovascular Surgery
- Vol. 49 (1) , 83-89
Detection of Peripheral Arterial Disease Within the Foot Using Vascular Optical Tomographic Imaging: A Clinical Pilot Study
- 1 January 2015
- Published by Elsevier in European Journal of Vascular and Endovascular Surgery
- Vol. 49 (1) , 83-89
Detection of Peripheral Arterial Disease Within the Foot Using Vascular Optical Tomographic Imaging: A Clinical Pilot Study
- Open Access
- 1 July 2013
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 18 (7) , 076002
Computer-aided diagnosis of rheumatoid arthritis with optical tomography, Part 2: image classification
This is the second part of a two-part paper on the application of computer-aided diagnosis to diffuse optical tomography (DOT) for diagnosing rheumatoid arthritis (RA). A comprehensive analysis of techniques for the classification of DOT images of proximal interphalangeal joints of subjects with and without RA is presented. A method for extracting heuristic features from DOT images was presented in Part 1. The ability of five classification algorithms to accurately label each DOT image as belonging to a subject with or without RA is analyzed here. The algorithms of interest are the -nearest-neighbors, linear and quadratic discriminant analysis, self-organizing maps, and support vector machines (SVM). With a polynomial SVM classifier, we achieve 100.0% sensitivity and 97.8% specificity. Lower bounds for these results (at 95.0% confidence level) are 96.4% and 93.8%, respectively. Image features most predictive of RA are from the spatial variation of optical properties and the absolute range in feature values. The optimal classifiers are low-dimensional combinations ( features). These results underscore the high potential for DOT to become a clinically useful diagnostic tool and warrant larger prospective clinical trials to conclusively demonstrate the ultimate clinical utility of this approach.- 1 July 2013
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 18 (7) , 076002
Open AccessComputer-aided diagnosis of rheumatoid arthritis with optical tomography, Part 2: image classification
This is the second part of a two-part paper on the application of computer-aided diagnosis to diffuse optical tomography (DOT) for diagnosing rheumatoid arthritis (RA). A comprehensive analysis of techniques for the classification of DOT images of proximal interphalangeal joints of subjects with and without RA is presented. A method for extracting heuristic features from DOT images was presented in Part 1. The ability of five classification algorithms to accurately label each DOT image as belonging to a subject with or without RA is analyzed here. The algorithms of interest are the -nearest-neighbors, linear and quadratic discriminant analysis, self-organizing maps, and support vector machines (SVM). With a polynomial SVM classifier, we achieve 100.0% sensitivity and 97.8% specificity. Lower bounds for these results (at 95.0% confidence level) are 96.4% and 93.8%, respectively. Image features most predictive of RA are from the spatial variation of optical properties and the absolute range in feature values. The optimal classifiers are low-dimensional combinations ( features). These results underscore the high potential for DOT to become a clinically useful diagnostic tool and warrant larger prospective clinical trials to conclusively demonstrate the ultimate clinical utility of this approach. - Open Access
- 1 July 2013
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 18 (7) , 076001
Computer-aided diagnosis of rheumatoid arthritis with optical tomography, Part 1: feature extraction
This is the first part of a two-part paper on the application of computer-aided diagnosis to diffuse optical tomography (DOT). An approach for extracting heuristic features from DOT images and a method for using these features to diagnose rheumatoid arthritis (RA) are presented. Feature extraction is the focus of Part 1, while the utility of five classification algorithms is evaluated in Part 2. The framework is validated on a set of 219 DOT images of proximal interphalangeal (PIP) joints. Overall, 594 features are extracted from the absorption and scattering images of each joint. Three major findings are deduced. First, DOT images of subjects with RA are statistically different () from images of subjects without RA for over 90% of the features investigated. Second, DOT images of subjects with RA that do not have detectable effusion, erosion, or synovitis (as determined by MRI and ultrasound) are statistically indistinguishable from DOT images of subjects with RA that do exhibit effusion, erosion, or synovitis. Thus, this subset of subjects may be diagnosed with RA from DOT images while they would go undetected by reviews of MRI or ultrasound images. Third, scattering coefficient images yield better one-dimensional classifiers. A total of three features yield a Youden index greater than 0.8. These findings suggest that DOT may be capable of distinguishing between PIP joints that are healthy and those affected by RA with or without effusion, erosion, or synovitis.- 1 July 2013
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 18 (7) , 076001
Open AccessComputer-aided diagnosis of rheumatoid arthritis with optical tomography, Part 1: feature extraction
This is the first part of a two-part paper on the application of computer-aided diagnosis to diffuse optical tomography (DOT). An approach for extracting heuristic features from DOT images and a method for using these features to diagnose rheumatoid arthritis (RA) are presented. Feature extraction is the focus of Part 1, while the utility of five classification algorithms is evaluated in Part 2. The framework is validated on a set of 219 DOT images of proximal interphalangeal (PIP) joints. Overall, 594 features are extracted from the absorption and scattering images of each joint. Three major findings are deduced. First, DOT images of subjects with RA are statistically different () from images of subjects without RA for over 90% of the features investigated. Second, DOT images of subjects with RA that do not have detectable effusion, erosion, or synovitis (as determined by MRI and ultrasound) are statistically indistinguishable from DOT images of subjects with RA that do exhibit effusion, erosion, or synovitis. Thus, this subset of subjects may be diagnosed with RA from DOT images while they would go undetected by reviews of MRI or ultrasound images. Third, scattering coefficient images yield better one-dimensional classifiers. A total of three features yield a Youden index greater than 0.8. These findings suggest that DOT may be capable of distinguishing between PIP joints that are healthy and those affected by RA with or without effusion, erosion, or synovitis. - 1 January 2012
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 17 (1) , 0160141-0160148
Monitoring early tumor response to drug therapy with diffuse optical tomography
Although anti-angiogenic agents have shown promise as cancer therapeutics, their efficacy varies between tumor types and individual patients. Providing patient-specific metrics through rapid noninvasive imaging can help tailor drug treatment by optimizing dosages, timing of drug cycles, and duration of therapy—thereby reducing toxicity and cost and improving patient outcome. Diffuse optical tomography (DOT) is a noninvasive three-dimensional imaging modality that has been shown to capture physiologic changes in tumors through visualization of oxygenated, deoxygenated, and total hemoglobin concentrations, using non-ionizing radiation with near-infrared light. We employed a small animal model to ascertain if tumor response to bevacizumab (BV), an anti-angiogenic agent that targets vascular endothelial growth factor (VEGF), could be detected at early time points using DOT. We detected a significant decrease in total hemoglobin levels as soon as one day after BV treatment in responder xenograft tumors (SK-NEP-1), but not in SK-NEP-1 control tumors or in non-responder control or BV-treated NGP tumors. These results are confirmed by magnetic resonance imaging T2 relaxometry and lectin perfusion studies. Noninvasive DOT imaging may allow for earlier and more effective control of anti-angiogenic therapy.
- 1 January 2012
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 17 (1) , 0160141-0160148
Monitoring early tumor response to drug therapy with diffuse optical tomography
Although anti-angiogenic agents have shown promise as cancer therapeutics, their efficacy varies between tumor types and individual patients. Providing patient-specific metrics through rapid noninvasive imaging can help tailor drug treatment by optimizing dosages, timing of drug cycles, and duration of therapy—thereby reducing toxicity and cost and improving patient outcome. Diffuse optical tomography (DOT) is a noninvasive three-dimensional imaging modality that has been shown to capture physiologic changes in tumors through visualization of oxygenated, deoxygenated, and total hemoglobin concentrations, using non-ionizing radiation with near-infrared light. We employed a small animal model to ascertain if tumor response to bevacizumab (BV), an anti-angiogenic agent that targets vascular endothelial growth factor (VEGF), could be detected at early time points using DOT. We detected a significant decrease in total hemoglobin levels as soon as one day after BV treatment in responder xenograft tumors (SK-NEP-1), but not in SK-NEP-1 control tumors or in non-responder control or BV-treated NGP tumors. These results are confirmed by magnetic resonance imaging T2 relaxometry and lectin perfusion studies. Noninvasive DOT imaging may allow for earlier and more effective control of anti-angiogenic therapy.
- 5 April 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 30 (10) , 1725-1736
Frequency-Domain Optical Tomographic Imaging of Arthritic Finger Joints
We are presenting data from the largest clinical trial on optical tomographic imaging of finger joints to date. Overall we evaluated 99 fingers of patients affected by rheumatoid arthritis (RA) and 120 fingers from healthy volunteers. Using frequency-domain imaging techniques we show that sensitivities and specificities of 0.85 and higher can be achieved in detecting RA. This is accomplished by deriving multiple optical parameters from the optical tomographic images and combining them for the statistical analysis. Parameters derived from the scattering coefficient perform slightly better than absorption derived parameters. Furthermore we found that data obtained at 600 MHz leads to better classification results than data obtained at 0 or 300 MHz.
- 5 April 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 30 (10) , 1725-1736
Frequency-Domain Optical Tomographic Imaging of Arthritic Finger Joints
We are presenting data from the largest clinical trial on optical tomographic imaging of finger joints to date. Overall we evaluated 99 fingers of patients affected by rheumatoid arthritis (RA) and 120 fingers from healthy volunteers. Using frequency-domain imaging techniques we show that sensitivities and specificities of 0.85 and higher can be achieved in detecting RA. This is accomplished by deriving multiple optical parameters from the optical tomographic images and combining them for the statistical analysis. Parameters derived from the scattering coefficient perform slightly better than absorption derived parameters. Furthermore we found that data obtained at 600 MHz leads to better classification results than data obtained at 0 or 300 MHz.