Paul D. Siney
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Paul D. Siney has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
B. M. Wroblewski
The John Charnley Research Institute, Wrightington Hospital, Hall Lane, Appley Bridge, Wigan WN6 9EP, UK
3 shared publicationsP. A. Fleming
The John Charnley Research Institute, Wrightington Hospital, Hall Lane, Appley Bridge, Wigan WN6 9EP, UK
3 shared publicationsB Michael Wroblewski
The John Charnley Research Institute, Wrightington Hospital, Hall Lane, Appley Bridge, N Wigan, UK
1 shared publicationB. Purbach
The John Charnley Institute Wrightington Hospital, Hall Lane, Appley Bridge, Wigan WN6 9EP, UK
1 shared publicationB.M. Wroblewski
Department of Orthopaedic Biomechanics, The John Charnley Research Institute, Wrightington Hospital, Nr. Wigan, United Kingdom
1 shared publicationPatricia A Fleming
The John Charnley Research Institute, Wrightington Hospital, Hall Lane, Appley Bridge, N Wigan, UK
1 shared publication
Latest Publications
- Open Access
- 1 March 2012
- Published by British Editorial Society of Bone & Joint Surgery in Bone & Joint Research
- Vol. 1 (3) , 25-30
Microseparation, fluid pressure and flow in failures of metal-on-metal hip resurfacing arthroplasties
Objectives: Metal-on-metal (MoM) hip resurfacing was introduced into clinical practice because it was perceived to be a better alternative to conventional total hip replacement for young and active patients. However, an increasing number of reports of complications have arisen focusing on design and orientation of the components, the generation of metallic wear particles and serum levels of metallic ions. The procedure introduced a combination of two elements: large-dimension components and hard abrasive particles of metal wear. The objective of our study was to investigate the theory that microseparation of the articular surfaces draws in a high volume of bursal fluid and its contents into the articulation, and at relocation under load would generate high pressures of fluid ejection, resulting in an abrasive water jet. Methods: This theoretical concept using MoM resurfacing components (head diameter 55 mm) was modelled mathematically and confirmed experimentally using a material-testing machine that pushed the head into the cup at a rate of 1000 mm/min until fully engaged. Results: The mathematical model showed the pattern but not the force of fluid ejection, the highest pressures were expected when the separation of the components was only a fraction of one millimetre. The experimental work confirmed the results; with the mean peak ejection pressure of 43 763 N/m2 equivalent to 306 mmHg or 5 psi. Conclusions: The mechanical effect of the high-pressure abrasive water jet is the likely cause of the spectrum of complications reported with metal-on-metal resurfacing. Investigating serum levels of metallic elements may not be the best method for assessing the local mechanical effects of the abrasive water jet.
- 1 March 2012
- Published by British Editorial Society of Bone & Joint Surgery in Bone & Joint Research
- Vol. 1 (3) , 25-30
Open AccessMicroseparation, fluid pressure and flow in failures of metal-on-metal hip resurfacing arthroplasties
Objectives: Metal-on-metal (MoM) hip resurfacing was introduced into clinical practice because it was perceived to be a better alternative to conventional total hip replacement for young and active patients. However, an increasing number of reports of complications have arisen focusing on design and orientation of the components, the generation of metallic wear particles and serum levels of metallic ions. The procedure introduced a combination of two elements: large-dimension components and hard abrasive particles of metal wear. The objective of our study was to investigate the theory that microseparation of the articular surfaces draws in a high volume of bursal fluid and its contents into the articulation, and at relocation under load would generate high pressures of fluid ejection, resulting in an abrasive water jet. Methods: This theoretical concept using MoM resurfacing components (head diameter 55 mm) was modelled mathematically and confirmed experimentally using a material-testing machine that pushed the head into the cup at a rate of 1000 mm/min until fully engaged. Results: The mathematical model showed the pattern but not the force of fluid ejection, the highest pressures were expected when the separation of the components was only a fraction of one millimetre. The experimental work confirmed the results; with the mean peak ejection pressure of 43 763 N/m2 equivalent to 306 mmHg or 5 psi. Conclusions: The mechanical effect of the high-pressure abrasive water jet is the likely cause of the spectrum of complications reported with metal-on-metal resurfacing. Investigating serum levels of metallic elements may not be the best method for assessing the local mechanical effects of the abrasive water jet.
- Open Access
- 1 April 2010
- Published by British Editorial Society of Bone & Joint Surgery in The Journal of Bone and Joint Surgery. British volume
- Vol. 92-B (4) , 486-488
Charnley low-friction arthroplasty in teenage patients
Increasing follow-up identifies the outcome in younger patients who have undergone total hip replacement (THR) and reveals the true potential for survival of the prosthesis. We identified 28 patients (39 THRs) who had undergone cemented Charnley low friction arthroplasty between 1969 and 2001. Their mean age at operation was 17.9 years (12 to 19) and the maximum follow-up was 34 years. Two patients (4 THRs) were lost to follow-up, 13 (16 THRs) were revised at a mean period of 19.1 years (8 to 34) and 13 (19 THRs) continue to attend regular follow-up at a mean of 12.6 years (2.3 to 29). In this surviving group one acetabular component was radiologically loose and all femoral components were secure. In all the patients the diameter of the femoral head was 22.225 mm with Charnley femoral components used in 29 hips and C-stem femoral components in ten. In young patients who require THR the acetabular bone stock is generally a limiting factor for the size of the component. Excellent long-term results can be obtained with a cemented polyethylene acetabular component and a femoral head of small diameter.
- 1 April 2010
- Published by British Editorial Society of Bone & Joint Surgery in The Journal of Bone and Joint Surgery. British volume
- Vol. 92-B (4) , 486-488
Open AccessCharnley low-friction arthroplasty in teenage patients
Increasing follow-up identifies the outcome in younger patients who have undergone total hip replacement (THR) and reveals the true potential for survival of the prosthesis. We identified 28 patients (39 THRs) who had undergone cemented Charnley low friction arthroplasty between 1969 and 2001. Their mean age at operation was 17.9 years (12 to 19) and the maximum follow-up was 34 years. Two patients (4 THRs) were lost to follow-up, 13 (16 THRs) were revised at a mean period of 19.1 years (8 to 34) and 13 (19 THRs) continue to attend regular follow-up at a mean of 12.6 years (2.3 to 29). In this surviving group one acetabular component was radiologically loose and all femoral components were secure. In all the patients the diameter of the femoral head was 22.225 mm with Charnley femoral components used in 29 hips and C-stem femoral components in ten. In young patients who require THR the acetabular bone stock is generally a limiting factor for the size of the component. Excellent long-term results can be obtained with a cemented polyethylene acetabular component and a femoral head of small diameter.
- Open Access
- 1 July 2009
- Published by British Editorial Society of Bone & Joint Surgery in The Journal of Bone and Joint Surgery. British volume
- Vol. 91-B (7) , 855-858
The principle of low frictional torque in the Charnley total hip replacement
The design of the Charnley total hip replacement follows the principle of low frictional torque. It is based on the largest possible difference between the radius of the femoral head and that of the outer aspect of the acetabular component. The aim is to protect the bone-cement interface by movement taking place at the smaller radius, the articulation. This is achieved in clinical practice by a 22.225 mm diameter head articulating with a 40 mm or 43 mm diameter acetabular component of ultra-high molecular weight polyethylene. We compared the incidence of aseptic loosening of acetabular components with an outer diameter of 40 mm and 43 mm at comparable depths of penetration with a mean follow-up of 17 years (1 to 40). In cases with no measurable wear none of the acetabular components were loose. With increasing acetabular penetration there was an increased incidence of aseptic loosening which reflected the difference in the external radii, with 1.5% at 1 mm, 8.8% at 2 mm, 9.7% at 3 mm and 9.6% at 4 mm of penetration in favour of the larger 43 mm acetabular component. Our findings support the Charnley principle of low frictional torque. The level of the benefit is in keeping with the predicted values.
- 1 July 2009
- Published by British Editorial Society of Bone & Joint Surgery in The Journal of Bone and Joint Surgery. British volume
- Vol. 91-B (7) , 855-858
Open AccessThe principle of low frictional torque in the Charnley total hip replacement
The design of the Charnley total hip replacement follows the principle of low frictional torque. It is based on the largest possible difference between the radius of the femoral head and that of the outer aspect of the acetabular component. The aim is to protect the bone-cement interface by movement taking place at the smaller radius, the articulation. This is achieved in clinical practice by a 22.225 mm diameter head articulating with a 40 mm or 43 mm diameter acetabular component of ultra-high molecular weight polyethylene. We compared the incidence of aseptic loosening of acetabular components with an outer diameter of 40 mm and 43 mm at comparable depths of penetration with a mean follow-up of 17 years (1 to 40). In cases with no measurable wear none of the acetabular components were loose. With increasing acetabular penetration there was an increased incidence of aseptic loosening which reflected the difference in the external radii, with 1.5% at 1 mm, 8.8% at 2 mm, 9.7% at 3 mm and 9.6% at 4 mm of penetration in favour of the larger 43 mm acetabular component. Our findings support the Charnley principle of low frictional torque. The level of the benefit is in keeping with the predicted values.
- Open Access
- 1 January 2007
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 78 (2) , 206-210
Charnley low-frictional torque arthroplasty in young rheumatoid and juvenile rheumatoid arthritis: 292 hips followed for an average of 15 years
Introduction In the early 1960s, Charnley was cautious with his patient selection for total hip replacement. As follow-up increased and confidence in the operation grew, younger patients were selected. We present our results of the Charnley LFA in young patients with rheumatoid and juvenile rheumatoid arthritis with a followup of up to 36 years. Patients We studied 292 Charnley low-friction arthroplasties in 195 young patients with an established diagnosis of rheumatoid arthritis. Their mean age at operation was 38 (12–50) years; 168 (58%) were receiving steroids and 79 (27%) were on non-steroidal antiinflammatory medication. The mean follow-up for the whole group was 15 (1–36) years. 24 patients could not be traced (33 hips), and 61 patients died (88 hips). Results 25 patients (41 hips) had had a revision. The main indication for revision was cup loosening. In the 85 patients (130 hips) attending follow-up, their mean age at surgery was 36 (17–50) years and the mean follow-up was 20 (10–36) years. 98% were pain-free or had no more than occasional discomfort, 44% claimed to have normal or near-normal function, while 62% had full or almost full range of movement of the replaced hip. Radiographically, 29 cups (22%) were considered to be loose. 1 stem (1%) was definitely loose and 2 stems (2%) were probably loose. With revision for any indication as the endpoint, the survival was 74% at 25 years follow-up. Interpretation The Charnley LFA continues to be an excellent hip replacement, even for very young rheumatoid arthritis patients. Wear and aseptic cup loosening are the main long-term problems.
- 1 January 2007
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 78 (2) , 206-210
Open AccessCharnley low-frictional torque arthroplasty in young rheumatoid and juvenile rheumatoid arthritis: 292 hips followed for an average of 15 years
Introduction In the early 1960s, Charnley was cautious with his patient selection for total hip replacement. As follow-up increased and confidence in the operation grew, younger patients were selected. We present our results of the Charnley LFA in young patients with rheumatoid and juvenile rheumatoid arthritis with a followup of up to 36 years. Patients We studied 292 Charnley low-friction arthroplasties in 195 young patients with an established diagnosis of rheumatoid arthritis. Their mean age at operation was 38 (12–50) years; 168 (58%) were receiving steroids and 79 (27%) were on non-steroidal antiinflammatory medication. The mean follow-up for the whole group was 15 (1–36) years. 24 patients could not be traced (33 hips), and 61 patients died (88 hips). Results 25 patients (41 hips) had had a revision. The main indication for revision was cup loosening. In the 85 patients (130 hips) attending follow-up, their mean age at surgery was 36 (17–50) years and the mean follow-up was 20 (10–36) years. 98% were pain-free or had no more than occasional discomfort, 44% claimed to have normal or near-normal function, while 62% had full or almost full range of movement of the replaced hip. Radiographically, 29 cups (22%) were considered to be loose. 1 stem (1%) was definitely loose and 2 stems (2%) were probably loose. With revision for any indication as the endpoint, the survival was 74% at 25 years follow-up. Interpretation The Charnley LFA continues to be an excellent hip replacement, even for very young rheumatoid arthritis patients. Wear and aseptic cup loosening are the main long-term problems.
- 1 December 2001
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 16 (8) , 37-41
Triple taper polished cemented stem in total hip arthroplasty: Rationale for the design, surgical technique, and 7 years of clinical experience
- 1 December 2001
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 16 (8) , 37-41
Triple taper polished cemented stem in total hip arthroplasty: Rationale for the design, surgical technique, and 7 years of clinical experience