Michael W. Kissick
Research Subjects
Michael W. Kissick has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
Albert van der Kogel
C Human Oncology, University of Wisconsin-Madison, Madison, Wisconsin; and
2 shared publicationsDavid Campos
A Laboratory for Optical and Computational Instrumentation, Vice Chancellor Office for Graduate Research and Education and Departments of
2 shared publications- Randall J. Kimple
University of Wisconsin Carbone Cancer Center, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin
2 shared publications T. Rockwell Mackie
Department of Medical Physics, Wisconsin Institutes for Medical Research, University of Wisconsin–Madison, 1111 Highland Avenue, Madison, Wisconsin 53705 and TomoTherapy, Inc., 1240 Deming Way, Madison, Wisconsin 53717
2 shared publicationsXiaohu Mo
Department of Medical Physics; Wisconsin Institutes for Medical Research; University of Wisconsin - Madison; Madison WI
2 shared publicationsBrian Burkel
A Laboratory for Optical and Computational Instrumentation, Vice Chancellor Office for Graduate Research and Education and Departments of
1 shared publication
Latest Publications
- 29 April 2016
- Published by Radiation Research Society in Radiation Research
- Vol. 185 (5) , 496-504
Radiation Promptly Alters Cancer Live Cell Metabolic Fluxes: An In Vitro Demonstration
Quantitative data is presented that shows significant changes in cellular metabolism in a head and neck cancer cell line 30 min after irradiation. A head and neck cancer cell line (UM-SCC-22B) and a comparable normal cell line, normal oral keratinocyte (NOK) were each separately exposed to 10 Gy and treated with a control drug for disrupting metabolism (potassium cyanide; KCN). The metabolic changes were measured live by fluorescence lifetime imaging of the intrinsically fluorescent intermediate metabolite nicotinamide adenosine dinucleotide (NADH) fluorescence; this method is sensitive to the ratio of bound to free NADH. The results indicated a prompt shift in metabolic signature in the cancer cell line, but not in the normal cell line. Control KCN treatment demonstrated expected metabolic fluxes due to mitochondrial disruption. The detected radiation shift in the cancer cells was blunted in the presence of both a radical scavenger and a HIF-1α inhibitor. The HIF-1α abundance as detected by immunohistochemical staining also increased substantially for these cancer cells, but not for the normal cells. This type of live-cell metabolic monitoring could be helpful for future real-time studies and in designing adaptive radiotherapy approaches.
- 29 April 2016
- Published by Radiation Research Society in Radiation Research
- Vol. 185 (5) , 496-504
Radiation Promptly Alters Cancer Live Cell Metabolic Fluxes: An In Vitro Demonstration
Quantitative data is presented that shows significant changes in cellular metabolism in a head and neck cancer cell line 30 min after irradiation. A head and neck cancer cell line (UM-SCC-22B) and a comparable normal cell line, normal oral keratinocyte (NOK) were each separately exposed to 10 Gy and treated with a control drug for disrupting metabolism (potassium cyanide; KCN). The metabolic changes were measured live by fluorescence lifetime imaging of the intrinsically fluorescent intermediate metabolite nicotinamide adenosine dinucleotide (NADH) fluorescence; this method is sensitive to the ratio of bound to free NADH. The results indicated a prompt shift in metabolic signature in the cancer cell line, but not in the normal cell line. Control KCN treatment demonstrated expected metabolic fluxes due to mitochondrial disruption. The detected radiation shift in the cancer cells was blunted in the presence of both a radical scavenger and a HIF-1α inhibitor. The HIF-1α abundance as detected by immunohistochemical staining also increased substantially for these cancer cells, but not for the normal cells. This type of live-cell metabolic monitoring could be helpful for future real-time studies and in designing adaptive radiotherapy approaches.
- 26 November 2013
- Published by Springer Nature
- p. 53-75
Motion Phantoms for Radiotherapy
- 24 September 2013
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 58 (20) , N279-N285
On the importance of prompt oxygen changes for hypofractionated radiation treatments
This discussion is motivated by observations of prompt oxygen changes occurring prior to a significant number of cancer cells dying (permanently stopping their metabolic activity) from therapeutic agents like large doses of ionizing radiation. Such changes must be from changes in the vasculature that supplies the tissue or from the metabolic changes in the tissue itself. An adapted linear-quadratic treatment is used to estimate the cell survival variation magnitudes from repair and reoxygenation from a two-fraction treatment in which the second fraction would happen prior to significant cell death from the first fraction, in the large fraction limit. It is clear the effects of oxygen changes are likely to be the most significant factor for hypofractionation because of large radiation doses. It is a larger effect than repair. Optimal dose timing should be determined by the peak oxygen timing. A call is made to prioritize near real time measurements of oxygen dynamics in tumors undergoing hypofractionated treatments in order to make these treatments adaptable and patient-specific.
- 24 September 2013
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 58 (20) , N279-N285
On the importance of prompt oxygen changes for hypofractionated radiation treatments
This discussion is motivated by observations of prompt oxygen changes occurring prior to a significant number of cancer cells dying (permanently stopping their metabolic activity) from therapeutic agents like large doses of ionizing radiation. Such changes must be from changes in the vasculature that supplies the tissue or from the metabolic changes in the tissue itself. An adapted linear-quadratic treatment is used to estimate the cell survival variation magnitudes from repair and reoxygenation from a two-fraction treatment in which the second fraction would happen prior to significant cell death from the first fraction, in the large fraction limit. It is clear the effects of oxygen changes are likely to be the most significant factor for hypofractionation because of large radiation doses. It is a larger effect than repair. Optimal dose timing should be determined by the peak oxygen timing. A call is made to prioritize near real time measurements of oxygen dynamics in tumors undergoing hypofractionated treatments in order to make these treatments adaptable and patient-specific.
- Open Access
- 6 September 2012
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 13 (5) , 155-169
Investigation of probabilistic optimization for tomotherapy
This work builds on a suite of studies related to the 'interplay', or lack thereof, for respiratory motion with helical tomotherapy (HT). It helps explain why HT treatments without active motion management had clinical outcomes that matched positive expectations. An analytical calculation is performed to illuminate the frequency range for which interplay-type dose errors could occur. Then, an experiment is performed which completes a suite of tests. The experiment shows the potential for a stable motion probability distribution function (PDF) with HT and respiratory motion. This PDF enables one to use a motion-robust or probabilistic optimization to intrinsically include respiratory motion into the treatment planning. The reason why HT is robust to respiratory motion is related to the beam modulation sampling of the tumor motion. Because active tracking-based motion management is more complicated for a variety of reasons, HT optimization that is robust to motion is a useful alternative for those many patients that cannot benefit from active motion management.
- 6 September 2012
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 13 (5) , 155-169
Open AccessInvestigation of probabilistic optimization for tomotherapy
This work builds on a suite of studies related to the 'interplay', or lack thereof, for respiratory motion with helical tomotherapy (HT). It helps explain why HT treatments without active motion management had clinical outcomes that matched positive expectations. An analytical calculation is performed to illuminate the frequency range for which interplay-type dose errors could occur. Then, an experiment is performed which completes a suite of tests. The experiment shows the potential for a stable motion probability distribution function (PDF) with HT and respiratory motion. This PDF enables one to use a motion-robust or probabilistic optimization to intrinsically include respiratory motion into the treatment planning. The reason why HT is robust to respiratory motion is related to the beam modulation sampling of the tumor motion. Because active tracking-based motion management is more complicated for a variety of reasons, HT optimization that is robust to motion is a useful alternative for those many patients that cannot benefit from active motion management.
- 30 April 2010
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 55 (10) , 2983-2995
A phantom model demonstration of tomotherapy dose painting delivery, including managed respiratory motion without motion management
The aim of the study was to demonstrate a potential alternative scenario for accurate dose-painting (non-homogeneous planned dose) delivery at 1 cm beam width with helical tomotherapy (HT) in the presence of 1 cm, three-dimensional, intra-fraction respiratory motion, but without any active motion management. A model dose-painting experiment was planned and delivered to the average position (proper phase of a 4DCT scan) with three spherical PTV levels to approximate dose painting to compensate for hypothetical hypoxia in a model lung tumor. Realistic but regular motion was produced with the Washington University 4D Motion Phantom. A small spherical Virtual Water (TM) phantom was used to simulate a moving lung tumor inside of the LUNGMAN (TM) anthropomorphic chest phantom to simulate realistic heterogeneity uncertainties. A piece of 4 cm Gafchromic EBT (TM) film was inserted into the 6 cm diameter sphere. TomoTherapy, Inc., DQA (TM) software was used to verify the delivery performed on a TomoTherapy Hi-Art II (TM) device. The dose uncertainty in the purposeful absence of motion management and in the absence of large, low frequency drifts (periods greater than the beam width divided by the couch velocity) or randomness in the breathing displacement yields very favorable results. Instead of interference effects, only small blurring is observed because of the averaging of many breathing cycles and beamlets and the avoidance of interference. Dose painting during respiration with helical tomotherapy is feasible in certain situations without motion management. A simple recommendation is to make respiration as regular as possible without low frequency drifting. The blurring is just small enough to suggest that it may be acceptable to deliver without motion management if the motion is equal to the beam width or smaller (at respiration frequencies) when registered to the average position.
- 30 April 2010
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 55 (10) , 2983-2995
A phantom model demonstration of tomotherapy dose painting delivery, including managed respiratory motion without motion management
The aim of the study was to demonstrate a potential alternative scenario for accurate dose-painting (non-homogeneous planned dose) delivery at 1 cm beam width with helical tomotherapy (HT) in the presence of 1 cm, three-dimensional, intra-fraction respiratory motion, but without any active motion management. A model dose-painting experiment was planned and delivered to the average position (proper phase of a 4DCT scan) with three spherical PTV levels to approximate dose painting to compensate for hypothetical hypoxia in a model lung tumor. Realistic but regular motion was produced with the Washington University 4D Motion Phantom. A small spherical Virtual Water (TM) phantom was used to simulate a moving lung tumor inside of the LUNGMAN (TM) anthropomorphic chest phantom to simulate realistic heterogeneity uncertainties. A piece of 4 cm Gafchromic EBT (TM) film was inserted into the 6 cm diameter sphere. TomoTherapy, Inc., DQA (TM) software was used to verify the delivery performed on a TomoTherapy Hi-Art II (TM) device. The dose uncertainty in the purposeful absence of motion management and in the absence of large, low frequency drifts (periods greater than the beam width divided by the couch velocity) or randomness in the breathing displacement yields very favorable results. Instead of interference effects, only small blurring is observed because of the averaging of many breathing cycles and beamlets and the avoidance of interference. Dose painting during respiration with helical tomotherapy is feasible in certain situations without motion management. A simple recommendation is to make respiration as regular as possible without low frequency drifting. The blurring is just small enough to suggest that it may be acceptable to deliver without motion management if the motion is equal to the beam width or smaller (at respiration frequencies) when registered to the average position.
- 24 November 2009
- Published by Wiley in Medical Physics
- Vol. 36 (12) , 5721-5722
Task Group 76 Report on ‘The management of respiratory motion in radiation oncology' [Med. Phys. 33, 3874–3900 (2006)]
- 24 November 2009
- Published by Wiley in Medical Physics
- Vol. 36 (12) , 5721-5722
Task Group 76 Report on ‘The management of respiratory motion in radiation oncology' [Med. Phys. 33, 3874–3900 (2006)]
- 10 April 2007
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 52 (9) , 2355-2365
A delivery transfer function (DTF) analysis for helical tomotherapy
The previous theoretical work of a delivery transfer function (DTF) in radiotherapy is expanded to include the unique intensity modulation method of helical tomotherapy. In addition to the collimation of each beamlet, and the Gaussian scatter convolution spreading of the dose that other radiotherapy units have, helical tomotherapy uses 51 small arcs of varying lengths to adjust the intensity. The blurring from these arcs is not taken into account during treatment planning. A theoretical DTF is constructed, and a calculation is performed which includes this unique source motion in relation to the other DTF components. Various typical delivery parameters are used to generate resolution maps for a constant intensity projection. Near the isocenter, the transverse (to a given beam direction) blurring is small but at larger radii (>6 cm), the source blurring dominates over leaf size. For most clinical situations, this inherent source motion blurring is expected to be negligible.
- 10 April 2007
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 52 (9) , 2355-2365
A delivery transfer function (DTF) analysis for helical tomotherapy
The previous theoretical work of a delivery transfer function (DTF) in radiotherapy is expanded to include the unique intensity modulation method of helical tomotherapy. In addition to the collimation of each beamlet, and the Gaussian scatter convolution spreading of the dose that other radiotherapy units have, helical tomotherapy uses 51 small arcs of varying lengths to adjust the intensity. The blurring from these arcs is not taken into account during treatment planning. A theoretical DTF is constructed, and a calculation is performed which includes this unique source motion in relation to the other DTF components. Various typical delivery parameters are used to generate resolution maps for a constant intensity projection. Near the isocenter, the transverse (to a given beam direction) blurring is small but at larger radii (>6 cm), the source blurring dominates over leaf size. For most clinical situations, this inherent source motion blurring is expected to be negligible.
- 23 June 2005
- Published by Wiley in Medical Physics
- Vol. 32 (7Part1) , 2346-2350
Confirmation, refinement, and extension of a study in intrafraction motion interplay with sliding jaw motion
The interplay between a constant scan speed and intrafraction oscillatory motion produces interesting fluence intensity modulations along the axis of motion that are sensitive to the motion function, as originally shown in a classic paper by Yu et al. [Phys. Med. Biol. 43, 91-104 (1998)]. The fluence intensity profiles are explored in this note for an intuitive understanding, then compared with Yu et al., and finally further explored for the effects of low scan speed and random components of both intrafraction and interfraction motion. At slow scan speeds typical of helical tomotherapy, these fluence intensity modulations are only a few percent. With the addition of only a small amount of cycle-to-cycle randomness in frequency and amplitude, the fluence intensity profiles change dramatically. It is further shown that after a typical 30-fraction treatment, the sensitivities displayed in the single fraction fluence intensity profiles greatly diminish.
- 23 June 2005
- Published by Wiley in Medical Physics
- Vol. 32 (7Part1) , 2346-2350
Confirmation, refinement, and extension of a study in intrafraction motion interplay with sliding jaw motion
The interplay between a constant scan speed and intrafraction oscillatory motion produces interesting fluence intensity modulations along the axis of motion that are sensitive to the motion function, as originally shown in a classic paper by Yu et al. [Phys. Med. Biol. 43, 91-104 (1998)]. The fluence intensity profiles are explored in this note for an intuitive understanding, then compared with Yu et al., and finally further explored for the effects of low scan speed and random components of both intrafraction and interfraction motion. At slow scan speeds typical of helical tomotherapy, these fluence intensity modulations are only a few percent. With the addition of only a small amount of cycle-to-cycle randomness in frequency and amplitude, the fluence intensity profiles change dramatically. It is further shown that after a typical 30-fraction treatment, the sensitivities displayed in the single fraction fluence intensity profiles greatly diminish.
- 27 April 2005
- Published by Wiley in Medical Physics
- Vol. 32 (5) , 1414-1423
The helical tomotherapy thread effect
Inherent to helical tomotherapy is a dose variation pattern that manifests as a “ripple” (peak‐to‐trough relative to the average). This ripple is the result of helical beam junctioning, completely unique to helical tomotherapy. Pitch is defined as in helical CT, the couch travel distance for a complete gantry rotation relative to the axial beam width at the axis of rotation. Without scattering or beam divergence, an analytical posing of the problem as a simple integral predicts minima near a pitch of where is an integer. A convolution‐superposition dose calculator (TomoTherapy, Inc.) included all the physics needed to explore the ripple magnitude versus pitch and beam width. The results of the dose calculator and some benchmark measurements demonstrate that the ripple has sharp minima near . The 0.86 factor is empirical and caused by a beam junctioning of the off‐axis dose profiles which differ from the axial profiles as well as a long scatter tail of the profiles at depth. For very strong intensity modulation, the 0.86 factor may vary. The authors propose choosing particular minima pitches or using a second delivery that starts 180 deg off‐phase from the first to reduce these ripples: “Double threading.” For current typical pitches and beam widths, however, this effect is small and not clinically important for most situations. Certain extremely large field or high pitch cases, however, may benefit from mitigation of this effect.
- 27 April 2005
- Published by Wiley in Medical Physics
- Vol. 32 (5) , 1414-1423
The helical tomotherapy thread effect
Inherent to helical tomotherapy is a dose variation pattern that manifests as a “ripple” (peak‐to‐trough relative to the average). This ripple is the result of helical beam junctioning, completely unique to helical tomotherapy. Pitch is defined as in helical CT, the couch travel distance for a complete gantry rotation relative to the axial beam width at the axis of rotation. Without scattering or beam divergence, an analytical posing of the problem as a simple integral predicts minima near a pitch of where is an integer. A convolution‐superposition dose calculator (TomoTherapy, Inc.) included all the physics needed to explore the ripple magnitude versus pitch and beam width. The results of the dose calculator and some benchmark measurements demonstrate that the ripple has sharp minima near . The 0.86 factor is empirical and caused by a beam junctioning of the off‐axis dose profiles which differ from the axial profiles as well as a long scatter tail of the profiles at depth. For very strong intensity modulation, the 0.86 factor may vary. The authors propose choosing particular minima pitches or using a second delivery that starts 180 deg off‐phase from the first to reduce these ripples: “Double threading.” For current typical pitches and beam widths, however, this effect is small and not clinically important for most situations. Certain extremely large field or high pitch cases, however, may benefit from mitigation of this effect.