Li Zhao
Research Subjects
Research Interests
Li Zhao has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
A Thomas
Department of Radiation Oncology, Duke University Medical Center, Durham, NC, USA 27710
1 shared publicationI J Das
Midwest Proton Radiotherapy Institute, Bloomington, IN, USA 47404
1 shared publicationIndra J Das
1 shared publicationJ Adamovics
Heuris Pharma LLC, 412 Sunset Rd., Skillman, NJ, USA 08558
1 shared publicationM Oldman
Department of Radiation Oncology, Duke University Medical Center, Durham, NC, USA 27710
1 shared publication- Qiuqu Zhao
Merck & Co., Inc., Kenilworth
1 shared publication
Latest Publications
- 1 November 2010
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 250 (1) , 012035
Determination of the depth dose distribution of proton beam using PRESAGETMdosimeter
PRESAGETM dosimeter dosimeter has been proved useful for 3D dosimetry in conventional photon therapy and IMRT [1–5]. Our objective is to examine the use of PRESAGETM dosimeter for verification of depth dose distribution in proton beam therapy. Three PRESAGETM samples were irradiated with a 79 MeV un-modulated proton beam. Percent depth dose profile measured from the PRESAGETM dosimeter is compared with data obtained in a water phantom using a parallel plate Advanced Markus chamber. The Bragg-peak position determined from the PRESAGETM is within 2 mm compared to measurements in water. PRESAGETM shows a highly linear response to proton dose. However, PRESAGETM also reveals an underdosage around the Bragg peak position due to LET effects. Depth scaling factor and quenching correction factor need further investigation. Our initial result shows that PRESAGETM has promising dosimetric characteristics that could be suitable for proton beam dosimetry.
- 1 November 2010
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 250 (1) , 012035
Determination of the depth dose distribution of proton beam using PRESAGETMdosimeter
PRESAGETM dosimeter dosimeter has been proved useful for 3D dosimetry in conventional photon therapy and IMRT [1–5]. Our objective is to examine the use of PRESAGETM dosimeter for verification of depth dose distribution in proton beam therapy. Three PRESAGETM samples were irradiated with a 79 MeV un-modulated proton beam. Percent depth dose profile measured from the PRESAGETM dosimeter is compared with data obtained in a water phantom using a parallel plate Advanced Markus chamber. The Bragg-peak position determined from the PRESAGETM is within 2 mm compared to measurements in water. PRESAGETM shows a highly linear response to proton dose. However, PRESAGETM also reveals an underdosage around the Bragg peak position due to LET effects. Depth scaling factor and quenching correction factor need further investigation. Our initial result shows that PRESAGETM has promising dosimetric characteristics that could be suitable for proton beam dosimetry.
- 29 April 2010
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 55 (10) , N291-N301
Gafchromic EBT film dosimetry in proton beams
The depth dose verification of active scanning proton beams is extremely time consuming with ion chamber measurements for beam data commissioning and patient specific measurements. With widespread use of Gafchromic EBT films, two-dimensional high-resolution dosimetry is explored in a uniform scanning proton beam. The EBT films were exposed parallel to the beam axis in a solid water phantom in order to obtain the depth-dose curve in a single measurement and compared with the gold standard measurement with a parallel plate ion chamber in water. Our results demonstrate that EBT films perform well in determining the proton beam range, with uncertainty of 0.5 mm. It is also found that EBT film response is a function of energy over the effective energy of 50-160 MeV proton beams with the variations less than 10%. However, an under-dosage of up to 20% was observed at the peak of the Bragg curve. An empirically derived correction factor is proposed to account for the EBT energy dependence. With corrections, EBT films can be a useful tool for the depth dose verification of active scanning proton beams, thus saving valuable proton beam time.
- 29 April 2010
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 55 (10) , N291-N301
Gafchromic EBT film dosimetry in proton beams
The depth dose verification of active scanning proton beams is extremely time consuming with ion chamber measurements for beam data commissioning and patient specific measurements. With widespread use of Gafchromic EBT films, two-dimensional high-resolution dosimetry is explored in a uniform scanning proton beam. The EBT films were exposed parallel to the beam axis in a solid water phantom in order to obtain the depth-dose curve in a single measurement and compared with the gold standard measurement with a parallel plate ion chamber in water. Our results demonstrate that EBT films perform well in determining the proton beam range, with uncertainty of 0.5 mm. It is also found that EBT film response is a function of energy over the effective energy of 50-160 MeV proton beams with the variations less than 10%. However, an under-dosage of up to 20% was observed at the peak of the Bragg curve. An empirically derived correction factor is proposed to account for the EBT energy dependence. With corrections, EBT films can be a useful tool for the depth dose verification of active scanning proton beams, thus saving valuable proton beam time.