Gafchromic EBT film dosimetry in proton beams
Authors:
- Li ZhaoLZLi Zhao
- Indra J DasIDIndra J Das
- 29 April 2010
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 55 (10) , N291-N301
Abstract
The depth dose verification of active scanning proton beams is extremely time consuming with ion chamber measurements for beam data commissioning and patient specific measurements. With widespread use of Gafchromic EBT films, two-dimensional high-resolution dosimetry is explored in a uniform scanning proton beam. The EBT films were exposed parallel to the beam axis in a solid water phantom in order to obtain the depth-dose curve in a single measurement and compared with the gold standard measurement with a parallel plate ion chamber in water. Our results demonstrate that EBT films perform well in determining the proton beam range, with uncertainty of 0.5 mm. It is also found that EBT film response is a function of energy over the effective energy of 50-160 MeV proton beams with the variations less than 10%. However, an under-dosage of up to 20% was observed at the peak of the Bragg curve. An empirically derived correction factor is proposed to account for the EBT energy dependence. With corrections, EBT films can be a useful tool for the depth dose verification of active scanning proton beams, thus saving valuable proton beam time.Keywords
This publication has 12 references indexed in Scilit:
- Experimental study of the response of radiochromic films to proton radiation of low energyNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 2009
- Clinical characterization of a proton beam continuous uniform scanning system with dose layer stackingMedical Physics, 2008
- Use of a two‐dimensional ionization chamber array for proton therapy beam quality assuranceMedical Physics, 2008
- TG‐69: Radiographic film for megavoltage beam dosimetryMedical Physics, 2007
- Directional dependence in film dosimetry: radiographic and radiochromic filmPhysics in Medicine & Biology, 2001
- Radiochromic film dosimetry of a low energy proton beamMedical Physics, 2000
- An application of GafChromic MD-55 film for 67.5 MeV clinical proton beam dosimetryPhysics in Medicine & Biology, 1999
- Comparison of dose response of radiochromic film measured with He‐Ne laser, broadband, and filtered light densitometersMedical Physics, 1997
- Radiochromic film dosimetry for clinical proton beamsApplied Radiation and Isotopes, 1997
- Investigation of applicability of alanine and radiochromic detectors to dosimetry of proton clinical beamsApplied Radiation and Isotopes, 1995