BCBenjamin M. Clasie

Benjamin M. Clasie

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Benjamin M. Clasie has a total of 30 co-authors. Here are the top co-authors by number of shared publications:

  • Hanne M Kooy

    Radiation Oncology, Massachusetts General Hospital, Fruit Street, Boston, Massachusetts, 02114, UNITED STATES

    5 shared publications
  • Jacob B Flanz

    Formerly Massachusetts General Hospital & Harvard Medical School, 30 Fruit St, Boston, 02114, UNITED STATES

    5 shared publications
  • Carles Gomà

    Department of Radiation Oncology, Hospital Clínic de Barcelona, Barcelona, Spain; Translational Genomics and Targeted Therapies in Solid Tumors, Institute for Biomedical Research August Pi i Sunyer (IDIBAPS), Barcelona, Spain

    2 shared publications
  • Hamid Reza Panahandeh

    Formerly Massachusetts General Hospital & Harvard Medical School, 30 Fruit St, Boston, 02114, UNITED STATES

    2 shared publications
  • Hanne Kooy

    Department of Radiation Oncology Massachusetts General Hospital and Harvard Medical School Boston Massachusetts USA

    2 shared publications
  • Jacob Flanz

    Massachusetts General Hospital and Harvard Medical School

    2 shared publications

Latest Publications

  • Corrigendum: Golden beam data for proton pencil-beam scanning (2012 Phys. Med. Biol. 57 1147)

    by Benjamin Clasie, Nicolas Depauw, Maurice Fransen, Carles Gomà, Hamid Reza Panahandeh, Joao Seco, Jacob B Flanz, Hanne M Kooy

  • Open Access

    Beam Position Projection Algorithms in Proton Pencil Beam Scanning

    by Konrad P. Nesteruk, Stephen G. Bradley, Hanne M. Kooy, Benjamin M. Clasie

    Beam position uncertainties along the beam trajectory arise from the accelerator, beamline, and scanning magnets (SMs). They can be monitored in real time, e.g., through strip ionization chambers (ICs), and treatments can be paused if needed. Delivery is more reliable and accurate if the beam position is projected from monitored nozzle parameters to the isocenter, allowing for accurate online corrections to be performed. Beam position projection algorithms are also used in post-delivery log file analyses. In this paper, we investigate the four potential algorithms that can be applied to all pencil beam scanning (PBS) nozzles. For some combinations of nozzle configurations and algorithms, however, the projection uses beam properties determined offline (e.g., through beam tuning or technical commissioning). The best algorithm minimizes either the total uncertainty (i.e., offline and online) or the total offline uncertainty in the projection. Four beam position algorithms are analyzed (A1–A4). Two nozzle lengths are used as examples: a large nozzle (1.5 m length) and a small nozzle (0.4 m length). Three nozzle configurations are considered: IC after SM, IC before SM, and ICs on both sides. Default uncertainties are selected for ion chamber measurements, nozzle entrance beam position and angle, and scanning magnet angle. The results for other uncertainties can be determined by scaling these results or repeating the error propagation. We show the propagation of errors from two locations and the SM angle to the isocenter for all the algorithms. The best choice of algorithm depends on the nozzle length and is A1 and A3 for the large and small nozzles, respectively. If the total offline uncertainty is to be minimized (a better choice if the offline uncertainty is not stable), the best choice of algorithm changes to A1 for the small nozzle for some hardware configurations. Reducing the nozzle length can help to reduce the gantry size and make proton therapy more accessible. This work is important for designing smaller nozzles and, consequently, smaller gantries. This work is also important for log file analyses.


  • Proton Therapy Equipment Installation, Upgrades, and Building Design

    by Benjamin M. Clasie, Daniel Letourneau, Marco Schwarz, Jan Seuntjens, Richard L. Maughan


  • Pencil beam scanning dose calibration at reduced source‐to‐axis distance

    by Nicolas Depauw, Hanne Kooy, Brian Winey, Benjamin Clasie

    Pencil beam scanning (PBS) monitoring chambers use an ionization control signal, monitor units (MUs), or gigaprotons (Gp) to irradiate a pencil beam and normalize dose calculations. The nozzle deflects the beam from the nozzle axis by an angle subtended at the source-to-axis distance (τ) from the isocenter. If the angle is not correctly considered in calibrations or calculations, it can lead to systematic errors. Aspects to consider for machines of various τs are fourfold. First, for the machine, there is a pathlength change of proton tracks in the monitor chamber. Second, for measurements, a uniform-square irradiation over a plane, with constant Gp per spot, does not deliver uniform dose in a measurement plane. Third, for Monte Carlo (MC) simulations, Gp (and not MU) is proportional to simulating a number of protons. Fourth, for pencil beam algorithms (PBA), MU or Gp may be used for pencil beam weight, but usage needs to be consistent. Another consideration is the beam shape change from circular to oval in the projection onto voxels. Coordinate systems for PBS delivery are described. Users of intermediate-τ machines, corresponding to the onset of 1% pathlength corrections within the scanned field size, must not assume that MUs are proportional to the number of particles in MC simulations, and the PBA may need pathlength corrections. For a field size of 24 × 24 cm2 , intermediate-τ machines correspond to 59 cm ≤ τ < 120 cm. For a field size of 40 × 40 cm2 , intermediate-τ machines correspond to 98 cm ≤ τ < 200 cm. Small-τ machines correspond to τ < 59 and 98 cm at these field sizes, respectively, which require corrections in projecting the beam shape onto voxels. Identifying corrections due to the pencil beam angle and their onset are important for reducing the outer diameter of proton therapy gantries. The use of Gp (or the number of protons) meterset standardizes data interchange and helps to reduce systematic errors due to the angle of the beam.


  • Retrofitting LINAC Vaults for Compact Proton Systems—Experiences Learned

    by Benjamin M. Clasie, Thomas R. Bortfeld, Hanne M. Kooy, Kelly Seybolt, Gregory C. Sharp, Brian Winey

    We describe the installation of the Gordon Browne Proton Therapy Center within the Lunder Building at Massachusetts General Hospital. Advances in compact proton units with modular design brought to life the vision of allocating a space in a tight corner of a fully functioning high-rise building and installing equipment via pathways typical in a hospital setting. While the assembled equipment is larger than a conventional photon therapy linear accelerator, LINAC, the proton therapy equipment was designed to be modular to make installation easier. This allowed the largest components to be lowered down an elevator shaft and transported past areas used for patient care. Issues that complicated the installation process include the sharing of the loading dock with other activities in the hospital, elevator inspections, after-hours deliveries, infection control, laydown space, and shielding requirements. This work is important in the identification of future sites for proton therapy.


  • Impacts of gantry angle dependent scanning beam properties on proton PBS treatment

    by Yuting Lin, Benjamin Clasie, Hsiao-Ming Lu, Jacob Flanz, Tim Shen, Kyung-Wook Jee

    While proton beam models in treatment planning systems are generally assumed invariant with respect to the beam deliveries at different gantry angles. Physical properties of scanning pencil beams can change. The gantry angle dependent properties include the delivered charge to the monitor unit chamber, the spot position and the spot shape. The aim of this study is to investigate the extent of the changes and their dosimetric impacts using historical pencil beam scanning (PBS) treatment data. Online beam delivery records at the time of the patient-specific qualify assurance were retrospectively collected for a total of 34 PBS fields from 28 patients treated at our institution. For each field, proton beam properties at two different gantry angles (the planned and zero gantry angles) were extracted by a newly-developed machine log analysis method and used to reconstruct the delivered dose distributions in the cubic water phantom geometry. The reconstructed doses at the two different angles and a planar dose measurement by a 2D ion-chamber array were compared and the dosimetric impacts of the gantry angle dependency were accessed by a 3D γ -index analysis. In addition, the pencil beam spot size was independently characterized as a function of the gantry angle and the beam energy. The dosimetric effects of the perturbed beam shape were also investigated. Comparisons of spot-by-spot beam positions between both gantry angles show a mean deviation of 0.4 and 0.7 mm and a standard deviation of 0.3 and 0.6 mm for x and y directions, respectively. The delivered giga-protons per spot show a percent mean difference and a standard deviation of 0.01% and 0.3%, respectively, from each planned spot weight. These small deviations lead to an excellent agreement in dose comparisons with an average γ passing rate of 99.1%. When each calculation for both planned and zero gantry angles was compared to the measurement, a high correlation in γ values was also observed, also indicating the dosimetric differences are small when a field is delivered at different gantry angles. Utilizing the online beam delivery records, the gantry angle dependencies of the PBS beam delivery were assessed and quantified. The study confirms the variations of the physical properties to be sufficiently small within the clinical tolerances without taking into account the gantry angle variation.


  • A Greedy reassignment algorithm for the PBS minimum monitor unit constraint

    by Yuting Lin, Hanne Kooy, David Craft, Nicolas Depauw, Jacob Flanz, Benjamin Clasie

    Proton pencil beam scanning (PBS) treatment plans are made of numerous unique spots of different weights. These weights are optimized by the treatment planning systems, and sometimes fall below the deliverable threshold set by the treatment delivery system. The purpose of this work is to investigate a Greedy reassignment algorithm to mitigate the effects of these low weight pencil beams. The algorithm is applied during post-processing to the optimized plan to generate deliverable plans for the treatment delivery system. The Greedy reassignment method developed in this work deletes the smallest weight spot in the entire field and reassigns its weight to its nearest neighbor(s) and repeats until all spots are above the minimum monitor unit (MU) constraint. Its performance was evaluated using plans collected from 190 patients (496 fields) treated at our facility. The Greedy reassignment method was compared against two other post-processing methods. The evaluation criteria was the γ -index pass rate that compares the pre-processed and post-processed dose distributions. A planning metric was developed to predict the impact of post-processing on treatment plans for various treatment planning, machine, and dose tolerance parameters. For fields with a pass rate of 90 ± 1% the planning metric has a standard deviation equal to 18% of the centroid value showing that the planning metric and γ -index pass rate are correlated for the Greedy reassignment algorithm. Using a 3rd order polynomial fit to the data, the Greedy reassignment method has 1.8 times better planning metric at 90% pass rate compared to other post-processing methods. As the planning metric and pass rate are correlated, the planning metric could provide an aid for implementing parameters during treatment planning, or even during facility design, in order to yield acceptable pass rates. More facilities are starting to implement PBS and some have spot sizes (one standard deviation) smaller than 5 mm, hence would require small spot spacing. While this is not the only parameter that affects the optimized plan, the perturbation due to the minimum MU constraint increases with decreasing spot spacing. This work could help to design the minimum MU threshold with the goal to keep the γ -index pass rate above an acceptable value.


  • PBS machine interlocks using EWMA

    by Benjamin M Clasie, Hanne M Kooy, Jacob B Flanz

    Delivery of pencil beam scanning (PBS) requires the on-line measurement of several beam parameters. If the measurement is outside of specified tolerances and a binary threshold algorithm is used, the beam will be paused. Given instrumentation and statistical noise such a system can lead to many pauses which could increase the treatment time. Statistical quality control methods are typically used on manufacturing lines to monitor a process and give early detection of a gradual problem and stop the process if a deviation is statistically significant. These methods can be used to develop a more intuitive algorithm for (PBS) delivery systems that is robust and safe and leads to decreased treatment times. The Exponentially Weighted Moving Average (EWMA) control scheme monitors deviations in beam properties which are averaged over a specified number of measurements with greater weight applied to the more recent ones. Simulation of an EWMA-style algorithm safely detected shifts in random and systematic delivery errors without false alarms. Binary and EWMA methods can be combined for improved reliability without sacrificing patient safety. In the EWMA method, the mean of a beam property can be related to systematic uncertainties and the standard deviation can be related to random uncertainties. This method allows one to have separate interlock levels for each type of uncertainty and to detect systematic trends.


  • Interpolation of tabulated proton Bragg peaks

    by Benjamin M Clasie, Jacob B Flanz, Hanne M Kooy

    Treatment planning databases for pencil beam scanning can be large, difficult to manage and problematic for quality assurance when they contain tabulated Bragg peaks at small range resolution. Smaller range resolution, in the absence of an accurate interpolation method, improves the accuracy in dose calculations. In this work, we derive an approximate scaling function to interpolate between tabulated Bragg peaks, and determine the accuracy of this interpolation technique and the minimum number of tabulated peaks in a treatment planning database. With the new interpolation technique, three tabulated mono-energetic Bragg peaks (N = 3) are a suitable lower limit for N to achieve interpolation accuracy better than +/- 1% of the maximum dose in pristine and spread out Bragg peaks for ranges between 6.8 and 32.1 cm of water.

  • Numerical solutions of the γ-index in two and three dimensions

    by Benjamin M Clasie, Gregory C Sharp, Joao Seco, Jacob B Flanz, Hanne M Kooy

    The γ-index is used routinely to establish correspondence between two dose distributions. The definition of the γ-index can be written with a single equation but solving this equation at millions of points is computationally expensive, especially in three dimensions. Our goal is to extend the vector-equation method in Bakai et al (2003 Phys. Med. Biol.48 3543-53) to higher order for better accuracy and, as important, to determine the magnitude of accuracy in a higher order solution. We construct a numerical framework for calculating the γ-index in two and three dimensions and present an efficient method for calculating the γ-index with zeroth-, first- and second-order methods using tricubic spline interpolation. For an intensity-modulated radiation therapy example with 1.78 × 10⁶ voxels, the zeroth-order, first-order, first-order iterations and semi-second-order methods calculate the three-dimensional γ-index in 1.5, 4.7, 34.7 and 35.6 s with 36.7%, 1.1%, 0.2% and 0.8% accuracy, respectively. The accuracy of linear interpolation with this example is 1.0%. We present efficient numerical methods for calculating the three-dimensional γ-index with tricubic spline interpolation. The first-order method with iterations is the most accurate and fastest choice of the numerical methods if the dose distributions may have large second-order gradients. Furthermore, the difference between iterations can be used to determine the accuracy of the method.