CGCarles Gomà

Carles Gomà

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Carles Gomà has a total of 101 co-authors. Here are the top co-authors by number of shared publications:

  • Sairos Safai

    Paul Scherrer Inst, Ctr Proton Therapy, Villigen, Switzerland

    4 shared publications
  • Benjamin M. Clasie

    Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA

    2 shared publications
  • Francesc Casas

    Department of Radiation Oncology, Hospital Clínic de Barcelona, Barcelona, Spain; Thoracic Oncology Unit, Hospital Clínic de Barcelona, Barcelona, Spain

    2 shared publications
  • Hamid Reza Panahandeh

    Formerly Massachusetts General Hospital & Harvard Medical School, 30 Fruit St, Boston, 02114, UNITED STATES

    2 shared publications
  • Hanne M Kooy

    Radiation Oncology, Massachusetts General Hospital, Fruit Street, Boston, Massachusetts, 02114, UNITED STATES

    2 shared publications
  • Ivan Vollmer

    Department of Radiology, Hospital Clínic de Barcelona, Barcelona, Spain; Thoracic Oncology Unit, Hospital Clínic de Barcelona, Barcelona, Spain; Translational Research in Pulmonary Vascular Diseases: Cell Proliferation and Apoptotic Mechanisms in Pulmonary Arterial Hypertension, Institute for Biomedical Research August Pi i Sunyer (IDIBAPS), Barcelona, Spain

    2 shared publications

Latest Publications

  • Corrigendum: Golden beam data for proton pencil-beam scanning (2012 Phys. Med. Biol. 57 1147)

    by Benjamin Clasie, Nicolas Depauw, Maurice Fransen, Carles Gomà, Hamid Reza Panahandeh, Joao Seco, Jacob B Flanz, Hanne M Kooy

  • Open Access

    ESTRO-EPTN radiation dosimetry guidelines for the acquisition of proton pencil beam modelling data

    by Carles Gomà, Katrin Henkner, Oliver Jäkel, Stefano Lorentini, Giuseppe Magro, Alfredo Mirandola, Lorenzo Placidi, Michele Togno, Marie Vidal, Gloria Vilches-Freixas, et al.


  • Biological equivalent dose is associated with radiological toxicity after lung stereotactic ablative radiation therapy

    by Carla Cases, Mariana Benegas, Marcelo Sánchez, Ivan Vollmer, Francesc Casas, Carles Gomà, Meritxell Mollà


  • Open Access

    Experimental assessment of inter-centre variation in stopping-power and range prediction in particle therapy

    by Nils Peters, Patrick Wohlfahrt, Christina V. Dahlgren, Ludovic de Marzi, Malte Ellerbrock, Francesco Fracchiolla, Jeffrey Free, Carles Gomà, Joanna Góra, Maria F. Jensen, et al.


  • Comment on ‘Lateral response heterogeneity of Bragg peak ionization chambers for narrow-beam photon and proton dosimetry’

    by Carles Gomà

    Kuess et al (2017 Phys. Med. Biol. 62 206–27) irradiated several PTW 34070 ionization chambers with a narrow x-ray beam impinging at different positions of the detector entrance window and they observed that the reading of the ionization chambers decreased as the impact point of the beam approached the edge of the sensitive volume. They concluded that the radial response of the detector decreased with increasing radius and they proposed a correction factor to correct for that effect. This work shows, by means of a simple Monte Carlo simulation, that the conclusions of Kuess and co-workers do not seem to be supported by their experimental findings—quite the opposite, their experimental results seem to be compatible with a rather homogeneous radial response of the PTW 34070. It is shown that the radial decrease in the ionization chamber reading (as the impact point of the beam approaches the edge of the sensitive volume) is not due to a radial decrease of the response, but to the fact that part of the energy transferred to the secondary electrons is carried away and deposited outside the sensitive volume of the ionization chamber. As a consequence, it is believed that the method and correction factors proposed by Kuess and colleagues are not suitable to assess the response uniformity of large-area ionization chambers. Furthermore, the results of the publications that have used them thus far should be thoroughly revised.


  • Open Access

    Calculated beam quality correction factors for ionization chambers in MV photon beams

    by Joonas Samuli Tikkanen, Klemens Zink, Maria Pimpinella, Pedro Teles, Jorge Borbinha, Jarkko Ojala, Teemu Siiskonen, Carles Gomà, Massimo Pinto

    The beam quality correction factor, , which corrects for the difference in the ionization chamber response between the reference and clinical beam quality, is an integral part of radiation therapy dosimetry. The uncertainty of is one of the most significant sources of uncertainty in the dose determination. To improve the accuracy of available data, four partners calculated factors for 10 ionization chamber models in linear accelerator beams with accelerator voltages ranging from 6 MV to 25 MV, including flattening-filter-free (FFF) beams. The software used in the calculations were EGSnrc and PENELOPE, and the ICRU report 90 cross section data for water and graphite were included in the simulations. Volume averaging correction factors were calculated to correct for the dose averaging in the chamber cavities. A comparison calculation between partners showed a good agreement, as did comparison with literature. The values from TRS-398 were higher than our values for each chamber where data was available. The values for the FFF beams did not follow the same , relation as beams with flattening filter (values for 10 MV FFF beams were below fits made to other data on average by 0.3%), although our FFF sources were only for Varian linacs.


  • Open Access

    Monte Carlo calculation of beam quality correction factors in proton beams using PENH

    by Carles Gomà, Edmond Sterpin

    This work calculates beam quality correction factors ( ) in both modulated and unmodulated proton beams using the Monte Carlo (MC) code . The latest ICRU 90 recommendations on key data for ionizing-radiation dosimetry were adopted to calculate the electronic stopping powers and to select the mean energy to create an ion pair in dry air ( ). For modulated proton beams, factors were calculated in the middle of a spread-out Bragg peak, while for monoenergetic proton beams they were calculated at the entrance region. Fifteen ionization chambers were simulated. The factors calculated in this work were found to agree within 0.8% or better with the experimental data reported in the literature. For some ionization chambers, the simulation of proton nuclear interactions were found to have an effect on the factors of up to 1%; while for some others, perturbation factors were found to differ from unity by more than 1%. In addition, the combined standard uncertainty in the MC calculated factors in proton beams was estimated to be of the order of 1%. Thus, the results of this work seem to indicate that: (i) the simulation of proton nuclear interactions should be included in the MC calculation of factors in proton beams, (ii) perturbation factors in proton beams should not be neglected, and (iii) the detailed MC simulation of ionization chambers allows for an accurate and precise calculation of factors in clinical proton beams.


  • Open Access

    Comparison of penh, fluka, and Geant4/topas for absorbed dose calculations in air cavities representing ionization chambers in high‐energy photon and proton beams

    by Kilian‐Simon Baumann, Felix Horst, Klemens Zink, Carles Gomà

    Purpose: The purpose of this work is to analyze whether the Monte Carlo codes penh, fluka, and geant4/topas are suitable to calculate absorbed doses and ratios in therapeutic high‐energy photon and proton beams.Methods: We used penh, fluka, geant4/topas, and egsnrc to calculate the absorbed dose to water in a reference water cavity and the absorbed dose to air in two air cavities representative of a plane‐parallel and a cylindrical ionization chamber in a 1.25 MeV photon beam and a 150 MeV proton beam — egsnrc was only used for the photon beam calculations. The physics and transport settings in each code were adjusted to simulate the particle transport as detailed as reasonably possible. From these absorbed doses, factors, factors, and ratios (which are the basis of Monte Carlo calculated beam quality correction factors ) were calculated and compared between the codes. Additionally, we calculated the spectra of primary particles and secondary electrons in the reference water cavity, as well as the integrated depth–dose curve of 150 MeV protons in water.Results: The absorbed doses agreed within 1.4% or better between the individual codes for both the photon and proton simulations. The and factors agreed within 0.5% or better for the individual codes for both beam qualities. The resulting ratios for 150 MeV protons agreed within 0.7% or better. For the 1.25 MeV photon beam, the spectra of photons and secondary electrons agreed almost perfectly. For the 150 MeV proton simulation, we observed differences in the spectra of secondary protons whereas the spectra of primary protons and low‐energy delta electrons also agreed almost perfectly. The first 2 mm of the entrance channel of the 150 MeV proton Bragg curve agreed almost perfectly while for greater depths, the differences in the integrated dose were up to 1.5%.Conclusion: penh, fluka, and geant4/topas are capable of calculating beam quality correction factors in proton beams. The differences in the and factors between the codes are 0.5% at maximum. The differences in the ratios are 0.7% at maximum.


  • Impact of machine log-files uncertainties on the quality assurance of proton pencil beam scanning treatment delivery

    by Simona Toscano, Kevin Souris, Carles Gomà, A Barragán-Montero, Sophie Puydupin, Francois Vander Stappen, Guillaume Janssens, Andrija Matic, Xavier Geets, Edmond Sterpin

    Irradiation log-files store useful information about the plan delivery, and together with independent Monte Carlo dose engine calculations can be used to reduce the time needed for patient-specific quality assurance (PSQA). Nonetheless, machine log-files carry an uncertainty associated to the measurement of the spot position and intensity that can influence the correct evaluation of the quality of the treatment delivery. This work addresses the problem of the inclusion of these uncertainties for the final verification of the treatment delivery. Dedicated measurements performed in an IBA Proteus Plus gantry with a pencil beam scanning (PBS) dedicated nozzle have been carried out to build a ‘room-dependent’ model of the spot position uncertainties. The model has been obtained through interpolation of the look-up tables describing the systematic and random uncertainties, and it has been tested for a clinical case of a brain cancer patient irradiated in a dry-run. The delivered dose has been compared with the planned dose with the inclusion of the errors obtained applying the model. Our results suggest that the accuracy of the treatment delivery is higher than the spot position uncertainties obtained from the log-file records. The comparison in terms of DVHs shows that the log-reconstructed dose is compatible with the planned dose within the 95% confidence interval obtained applying our model. The initial mean dose difference between the calculated dose to the patient based on the plan and recorded data is around 1%. The difference is essentially due to the log-file uncertainties and it can be removed with a correct treatment of these errors. In conclusion our new PSQA protocol allows for a fast verification of the dose delivered after every treatment fraction through the use of machine log-files and an independent Monte Carlo dose engine. Moreover, the inclusion of log-file uncertainties in the dose calculation allows for a correct evaluation of the quality of the treatment plan delivery.