Wenjing Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Wenjing Chen has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
Alexander Gemmel
Siemens Healthcare Sector, Imaging & Therapy Division, Particle Therapy, Hofmannstraße 26, 91052, Erlangen, Germany
1 shared publicationC Kurz
Heidelberg Ion Beam Therapy Center (HIT), Im Neuenheimer Feld 450, Heidelberg 69221, Germany
1 shared publicationEike Rietzel
Siemens Healthcare Sector, Imaging & Therapy Division, Particle Therapy, Hofmannstraße 26, 91052, Erlangen, Germany
1 shared publicationJ Bauer
Heidelberg Ion Beam Therapy Center (HIT), Im Neuenheimer Feld 450, Heidelberg 69221, Germany
1 shared publicationJ Debus
Heidelberg Ion Beam Therapy Center (HIT), Im Neuenheimer Feld 450, Heidelberg 69221, Germany
1 shared publicationJ Handrack
Heidelberg Ion Beam Therapy Center (HIT), Im Neuenheimer Feld 450, Heidelberg 69221, Germany
1 shared publication
Latest Publications
- Open Access
- 1 January 2017
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 777 (1) , 012021
A dedicated software application for treatment verification with off-line PET/CT imaging at the Heidelberg Ion Beam Therapy Center
We present the workflow of the offline-PET based range verification method used at the Heidelberg Ion Beam Therapy Center, detailing the functionalities of an in-house developed software application, SimInterface14, with which range analysis is performed. Moreover, we introduce the design of a decision support system assessing uncertainties and facilitating physicians in decisions making for plan adaptation.
- 1 January 2017
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 777 (1) , 012021
Open AccessA dedicated software application for treatment verification with off-line PET/CT imaging at the Heidelberg Ion Beam Therapy Center
We present the workflow of the offline-PET based range verification method used at the Heidelberg Ion Beam Therapy Center, detailing the functionalities of an in-house developed software application, SimInterface14, with which range analysis is performed. Moreover, we introduce the design of a decision support system assessing uncertainties and facilitating physicians in decisions making for plan adaptation.
- Open Access
- 1 July 2013
- Published by Oxford University Press (OUP) in Journal of Radiation Research
- Vol. 54 (suppl 1) , i82-i90
A patient-specific planning target volume used in 'plan of the day' adaptation for interfractional motion mitigation
We propose a patient-specific planning target volume (PTV) to deal with interfractional variations, and test its feasibility in a retrospective treatment-planning study. Instead of using one planning image only, multiple scans are taken on different days. The target and organs at risk (OARs) are delineated on each images. The proposed PTV is generated from a union of those target contours on the planning images, excluding voxels of the OARs, and is denoted the PTV ‘GP–OAR’ (global prostate–organs at risk). The study is performed using ‘plan of the day’ adaptive workflow, which selects a daily plan from a library of plans based on a similarity comparison between the daily scan and planning images. The daily plans optimized for GP–OAR volumes are compared with those optimized for PTVs generated from a single prostate contour (PTV SP). Four CT serials of prostate cancer patient datasets are included in the test, and in total 28 fractions are simulated. The results show that the daily chosen GP–OAR plans provide excellent target coverage, with V95 values of the prostate mostly > 95%. In addition, dose delivered to the OARs as calculated from applying daily chosen GP–OAR plans is slightly increased but comparable to that calculated from applying daily SP plans. In general, the PTV GP–OARs are able to cover possible target variations while keeping dose delivered to the OARs at a similar level to that of the PTV SPs.
- 1 July 2013
- Published by Oxford University Press (OUP) in Journal of Radiation Research
- Vol. 54 (suppl 1) , i82-i90
Open AccessA patient-specific planning target volume used in 'plan of the day' adaptation for interfractional motion mitigation
We propose a patient-specific planning target volume (PTV) to deal with interfractional variations, and test its feasibility in a retrospective treatment-planning study. Instead of using one planning image only, multiple scans are taken on different days. The target and organs at risk (OARs) are delineated on each images. The proposed PTV is generated from a union of those target contours on the planning images, excluding voxels of the OARs, and is denoted the PTV ‘GP–OAR’ (global prostate–organs at risk). The study is performed using ‘plan of the day’ adaptive workflow, which selects a daily plan from a library of plans based on a similarity comparison between the daily scan and planning images. The daily plans optimized for GP–OAR volumes are compared with those optimized for PTVs generated from a single prostate contour (PTV SP). Four CT serials of prostate cancer patient datasets are included in the test, and in total 28 fractions are simulated. The results show that the daily chosen GP–OAR plans provide excellent target coverage, with V95 values of the prostate mostly > 95%. In addition, dose delivered to the OARs as calculated from applying daily chosen GP–OAR plans is slightly increased but comparable to that calculated from applying daily SP plans. In general, the PTV GP–OARs are able to cover possible target variations while keeping dose delivered to the OARs at a similar level to that of the PTV SPs.